Test Setup photos_DXX_15.249

FCC ID: 2AN87AQUARISX2

Test Report

Download: PDF
FCCID_4070474

                            Test Report No.: RF180402W006-7


                                                                 FCC TEST REPORT
                                                               (Part 15, Subpart C)
        Applicant:                           Mundo Reader S.L.

                                             Calle Sofía 10, Parque Industrial y Tecnológico Európolis 28232 Las Rozas - Madrid
        Address:
                                             SPAIN


        Manufacturer or
                                             Mundo Reader S.L.
        Supplier
                                             Calle Sofía 10, Parque Industrial y Tecnológico Európolis 28232 Las Rozas - Madrid
        Address
                                             SPAIN

        Product                              Smartphone

        Brand Name                           BQ

        Model Name                           Aquaris X2

        FCC ID                               2AN87AQUARISX2

        Date of tests                        Aug. 10, 2018 ~ Sep. 11, 2018

        The tests have been carried out according to the requirements of the following standard:

               FCC Part 15, Subpart C, Section 15.249
               ANSI C63.10-2013

        CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                                 Prepared by Roger Li                                                                                  Approved by Sam Tung
                             Engineer / Mobile Department                                                                            Manager / Mobile Department




                                       Date: Sep. 12, 2018                                                                                    Date: Sep. 12, 2018
        This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
        http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or replication of this report to or for any other person
        or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results
        set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and
        expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is only provided upon
        request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence or if you require measurement uncertainty;
        provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you
        unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents.




                                                            No.B102, Dazu Chuangxin Mansion, North of Beihuan                                       Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                                            Avenue, North Area, Hi-Tech Industrial Park, Nanshan                                    Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                                                                                  Email: customerservice.dg@cn.bureauveritas.com
                                                            District, Shenzhen, Guangdong, China
                                                                                             Page 1 of 32


                       Test Report No.: RF180402W006-7

                                                  TABLE OF CONTENTS
         RELEASE CONTROL RECORD ............................................................................................................ 4
         1       SUMMARY OF TEST RESULTS .................................................................................................... 5
           1.1    MEASUREMENT UNCERTAINTY ............................................................................................... 5
         2       GENERAL INFORMATION ............................................................................................................ 6
           2.1    GENERAL DESCRIPTION OF EUT ............................................................................................. 6
           2.2    DESCRIPTION OF TEST MODES ............................................................................................... 7
                 2.2.1     CONFIGURATION OF SYSTEM UNDER TEST ............................................................... 8
                 2.2.2     TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL.................................... 8
           2.3    DUTY CYCLE OF TEST SIGNAL ............................................................................................... 10
           2.4    GENERAL DESCRIPTION OF APPLIED STANDARDS .............................................................11
           2.5    DESCRIPTION OF SUPPORT UNITS ........................................................................................11
         3       TEST TYPES AND RESULTS...................................................................................................... 12
           3.1    CONDUCTED EMISSION MEASUREMENT ............................................................................. 12
                 3.1.1     LIMITS OF CONDUCTED EMISSION MEASUREMENT ............................................... 12
                 3.1.2     TEST INSTRUMENTS ..................................................................................................... 12
                 3.1.3     TEST PROCEDURES ..................................................................................................... 13
                 3.1.4     DEVIATION FROM TEST STANDARD ........................................................................... 13
                 3.1.5     TEST SETUP ................................................................................................................... 14
                 3.1.6     EUT OPERATING CONDITIONS .................................................................................... 14
                 3.1.7     TEST RESULTS .............................................................................................................. 15
           3.2    20DB AND 99% BANDWIDTH MEASUREMENT ....................................................................... 17
                 3.2.1     LIMITS ............................................................................................................................. 17
                 3.2.2     TEST INSTRUMENTS ..................................................................................................... 17
                 3.2.3     TEST PROCEDURE ........................................................................................................ 17
                 3.2.4     DEVIATION FROM TEST STANDARD ........................................................................... 18
                 3.2.5     TEST SETUP ................................................................................................................... 18
                 3.2.6     EUT OPERATING CONDITIONS .................................................................................... 18
                 3.2.7     TEST RESULTS .............................................................................................................. 19
           3.3    FIELD STRENGTH OF FUNDAMENTAL EMISSIONS AND RADIATED SPURIOUS EMISSIONS
                  21
                 3.3.1     LIMITS ............................................................................................................................. 21
                 3.3.2     TEST INSTRUMENTS ..................................................................................................... 22
                 3.3.3     TEST PROCEDURES ..................................................................................................... 23
                 3.3.4     DEVIATION FROM TEST STANDARD ........................................................................... 23

                                               No.B102, Dazu Chuangxin Mansion, North of Beihuan                     Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                               Avenue, North Area, Hi-Tech Industrial Park, Nanshan                  Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                                                   Email: customerservice.dg@cn.bureauveritas.com
                                               District, Shenzhen, Guangdong, China
                                                                         Page 2 of 32


                       Test Report No.: RF180402W006-7
                 3.3.5       TEST SETUP ................................................................................................................... 24
                 3.3.6       EUT OPERATING CONDITIONS .................................................................................... 25
                 3.3.7       TEST RESULTS .............................................................................................................. 26
         4       PHOTOGRAPHS OF THE TEST CONFIGURATION .................................................................. 31
         5       APPENDIX A - MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT
         BY THE LAB ......................................................................................................................................... 32




                                                No.B102, Dazu Chuangxin Mansion, North of Beihuan                    Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                                Avenue, North Area, Hi-Tech Industrial Park, Nanshan                 Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                                                   Email: customerservice.dg@cn.bureauveritas.com
                                                District, Shenzhen, Guangdong, China
                                                                          Page 3 of 32


                    Test Report No.: RF180402W006-7



                                       RELEASE CONTROL RECORD

           ISSUE NO.               REASON FOR CHANGE                                                         DATE ISSUED
           RF180402W006-7          Original release                                                          Sep. 12, 2018




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 4 of 32


                    Test Report No.: RF180402W006-7

         1 SUMMARY OF TEST RESULTS
         The EUT has been tested according to the following specifications:
                           APPLIED STANDARD: FCC PART 15, SUBPART C (SECTION 15.247)
             STANDARD
                                       TEST TYPE AND LIMIT                   RESULT                     REMARK
              SECTION
                                                                                          Meet the requirement of limit.
                15.207        AC Power Conducted Emission                     PASS        Minimum passing margin is
                                                                                          -13.18dB at 4.548000MHz.

                2.1049        20dB &99% Occupied Bandwidth                    PASS        Meet the requirement of limit


               15.249(a)      Field Strength of Fundamental                   PASS        Meet the requirement of limit.

             15.249(a)(d)     Radiated Spurious Emissions                     PASS        Meet the requirement of limit.

                15.203        Antenna Requirement                             PASS        No antenna connector is used




         1.1 MEASUREMENT UNCERTAINTY

         Where relevant, the following measurement uncertainty levels have been estimated
         for tests performed on the EUT as specified in ETSI TR 100 028-2001:
                      MEASUREMENT                                FREQUENCY                           UNCERTAINTY
                    Conducted emissions                           9kHz~30MHz                               2.66dB
                                                                9KHz ~ 30MHz                               2.68dB
                                                               30MHz ~ 1GMHz                               3.26dB
                     Radiated emissions
                                                                1GHz ~ 18GHz                               4.48dB
                                                                18GHz ~ 40GHz                              4.12dB
         This uncertainty represents an expanded uncertainty expressed at approximately the
         95% confidence level using a coverage factor of k = 2.




                                        No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                        Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                             Email: customerservice.dg@cn.bureauveritas.com
                                        District, Shenzhen, Guangdong, China
                                                            Page 5 of 32


                    Test Report No.: RF180402W006-7


         2 GENERAL INFORMATION
         2.1 GENERAL DESCRIPTION OF EUT
            PRODUCT                                           Smartphone
            BRAND NAME                                        BQ
            MODEL NAME                                        Aquaris X2
                                                              5.0Vdc (adapter or host equipment)
            NOMINAL VOLTAGE                                   3.85V (Li-ion, battery)
            MODULATION TECHNOLOGY                             GFSK
            TRANSMISSION RATE                                 0.5 Mbps
            OPERATING FREQUENCY                               2402-2480MHz
            MAX. FIELD STRENGTH(PEAK)                         97.51dBuV/m
            MAX. FIELD STRENGTH(AVERAGE) 75.31dBuV/m
            ANTENNA TYPE                                      LDS Antenna with -3.9dBi gain
            HW VERSION                                        LLDM0893-3 VER:B3
            SW VERSION                                        1.3.1_20180904-0601
            I/O PORTS                                         Refer to user’s manual
            CABLE SUPPLIED                                    USB cable: non-shielded, detachable, 1.0m
         NOTE:
         1. For a more detailed features description, please refer to the manufacturer’s specifications or the
            user's manual.
         2. The EUT incorporates a SISO function. Physically, the EUT provides one transmitter and one
            receiver.
                   MODULATION MODE                      TX/RX FUNCTION
                              ANT+                                  1TX /1RX
         3. The EUT matched the following USB Cable:
            USB CABLE
            BRAND:                 bq
            MODEL:                 HY-005015
            SIGNAL LINE:           1.0 METER
         4. For the test results, the EUT had been tested with all conditions. But only the worst case was shown
            in test report.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 6 of 32


                    Test Report No.: RF180402W006-7


         2.2 DESCRIPTION OF TEST MODES
         79 channels are provided to this EUT:
                         FREQ.                        FREQ.                         FREQ.                          FREQ.
          CHANNEL                      CHANNEL                     CHANNEL                     CHANNEL
                         (MHz)                        (MHz)                         (MHz)                          (MHz)
               0          2402            20           2422             40           2442            60             2462
               1          2403            21           2423             41           2443            61             2463
               2          2404            22           2424             42           2444            62             2464
               3          2405            23           2425             43           2445            63             2465
               4          2406            24           2426             44           2446            64             2466
               5          2407            25           2427             45           2447            65             2467
               6          2408            26           2428             46           2448            66             2468
               7          2409            27           2429             47           2449            67             2469
               8          2410            28           2430             48           2450            68             2470
               9          2411            29           2431             49           2451            69             2471
              10          2412            30           2432             50           2452            70             2472
              11          2413            31           2433             51           2453            71             2473
              12          2414            32           2434             52           2454            72             2474
              13          2415            33           2435             53           2455            73             2475
              14          2416            34           2436             54           2456            74             2476
              15          2417            35           2437             55           2457            75             2477
              16          2418            36           2438             56           2458            76             2478
              17          2419            37           2439             57           2459            77             2479
              18          2420            38           2440             58           2460            78             2480
              19          2421            39           2441             59           2461




                                        No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                        Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                             Email: customerservice.dg@cn.bureauveritas.com
                                        District, Shenzhen, Guangdong, China
                                                            Page 7 of 32


                    Test Report No.: RF180402W006-7


         2.2.1 CONFIGURATION OF SYSTEM UNDER TEST

         Please see section 5 photographs of the test configuration for reference.

         2.2.2 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL

         Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
         between available modulations, data rates, XYZ axis and antenna ports.
         The worst case was found when positioned on Y axis for radiated emission. Following test modes were
         selected for the final test, and the final worst case is marked in boldface and recorded in the report:

                  EUT                         APPLICABLE TO
               CONFIGURE                                                                           MODE
                 MODE             RE<1G      RE≥1G         PLC      APCM

                       -            √              √        √         √                                -
               Where            RE<1G: Radiated Emission below 1GHz           RE≥1G: Radiated Emission above 1GHz
                                PLC: Power Line Conducted Emission            APCM: Antenna Port Conducted Measurement
               NOTE: No need to concern of Conducted Emission due to the EUT is powered by battery.




         RADIATED EMISSION TEST (BELOW 1GHz):

               Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
               between available modulations, data rates and antenna ports (if EUT with antenna diversity
               architecture).
               Following channel(s) was (were) selected for the final test as listed below.
                                                                                                       DATA
                                     AVAILABLE          TESTED      MODULATION       MODULATION
                    MODE                                                                               RATE
                                     CHANNEL           CHANNEL      TECHNOLOGY          TYPE
                                                                                                      (Mbps)
                           TX            0 to 78           79             ANT+           GFSK           0.5




           RADIATED EMISSION TEST (ABOVE 1GHz):
               Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
           between available modulations, data rates and antenna ports (if EUT with antenna diversity
           architecture).

              Following channel(s) was (were) selected for the final test as listed below.

                                                                                                     DATA
                                    AVAILABLE           TESTED     MODULATION       MODULATION
                   MODE                                                                              RATE
                                     CHANNEL           CHANNEL     TECHNOLOGY          TYPE
                                                                                                    (Mbps)
                       TX               0 to 78        0,39, 78        ANT+             GFSK           0.5




                                            No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                            Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                                 Email: customerservice.dg@cn.bureauveritas.com
                                            District, Shenzhen, Guangdong, China
                                                                  Page 8 of 32


                    Test Report No.: RF180402W006-7


           FIELD STRENGTH OF FUNDAMENTAL EMISSIONS
               Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
           between available modulations, data rates and antenna ports (if EUT with antenna diversity
           architecture).

              Following channel(s) was (were) selected for the final test as listed below.

                                                                                                     DATA
                                AVAILABLE         TESTED      MODULATION          MODULATION
                   MODE                                                                              RATE
                                 CHANNEL         CHANNEL      TECHNOLOGY             TYPE
                                                                                                    (Mbps)
                     TX           0 to 78        0,39, 78           ANT+              GFSK            0.5



           POWER LINE CONDUCTED EMISSION TEST:

               Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
               between available modulations, data rates and antenna ports (if EUT with antenna diversity
               architecture).
               Following channel(s) was (were) selected for the final test as listed below.
                                                                                                      DATA
                                 AVAILABLE        TESTED          MODULATION       MODULATION
                    MODE                                                                              RATE
                                 CHANNEL         CHANNEL          TECHNOLOGY          TYPE
                                                                                                     (Mbps)
                      TX           0 to 78        0,39, 78           ANT+               GFSK           0.5




           ANTENNA PORT CONDUCTED MEASUREMENT:

               This item includes all test value of each mode, but only includes spectrum plot of worst value of
               each mode.
               Pre-Scan has been conducted to determine the worst-case mode from all possible combinations
               between available modulations, data rates and antenna ports (if EUT with antenna diversity
               architecture).
               Following channel(s) was (were) selected for the final test as listed below.
                                  AVAILABLE           TESTED         MODULATION         MODULATION DATA RATE
                    MODE
                                   CHANNEL           CHANNEL         TECHNOLOGY            TYPE      (Mbps)
                      TX               0 to 78         0,39, 78            ANT+              GFSK               0.5



            TEST CONDITION:

                APPLICABLE
                    TO          ENVIRONMENTAL CONDITIONS                    TEST VOLTAGE                    TESTED BY

                   RE<1G                 22deg. C, 54%RH                   DC 5V from adaptor                 Vincent
                   RE≥1G                 22deg. C, 54%RH                   DC 5V from adaptor                 Vincent
                    FSFE                 22deg. C, 54%RH                   DC 5V from adaptor                 Vincent
                    PLC                  24deg. C, 55%RH                   DC 5V from adaptor                John Wen
                   APCM                  25deg. C, 60%RH                   3.85Vdc from battery             Wenliang Wu




                                        No.B102, Dazu Chuangxin Mansion, North of Beihuan         Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                        Avenue, North Area, Hi-Tech Industrial Park, Nanshan      Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                                Email: customerservice.dg@cn.bureauveritas.com
                                        District, Shenzhen, Guangdong, China
                                                             Page 9 of 32


                    Test Report No.: RF180402W006-7



         2.3 Duty Cycle of Test Signal

           Duty cycle = 0.156 /1.99 = 0.078 < 98%, Duty factor = 10 * log( 1/0.948) = 11.079




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 10 of 32


                     Test Report No.: RF180402W006-7



         2.4 GENERAL DESCRIPTION OF APPLIED STANDARDS
           The EUT is a RF Product. According to the specifications of the manufacturer, it
           must comply with the requirements of the following standards:

           FCC Part 15, Subpart C, Section 15.249
           ANSI C63.10-2013

           Note:
           1. All test items have been performed and recorded as per the above standards.
           2. The EUT is also considered as a kind of computer peripheral, because the
              connection to computer is necessary for typical use. It has been verified to comply
              with the requirements of FCC Part 15, Subpart B, Class B (Certification). The test
              report has been issued separately.




         2.5 DESCRIPTION OF SUPPORT UNITS
           The EUT has been tested as an independent unit together with other necessary
           accessories or support units. The following support units or accessories were used
           to form a representative test configuration during the tests.

              NO.       PRODUCT            BRAND           MODEL NO.              SERIAL NO.                   FCC ID
                1           PC                HP             A6608CN             3CR83825X3                      N/A


               NO.               SIGNAL CABLE DESCRIPTION OF THE ABOVE SUPPORT UNITS
                1    AC Line: Unshielded, Detachable 1.5m




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 11 of 32


                    Test Report No.: RF180402W006-7



         3 TEST TYPES AND RESULTS
         3.1 CONDUCTED EMISSION MEASUREMENT

         3.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT
             FREQUENCY OF EMISSION (MHz)                                   CONDUCTED LIMIT (dBµV)

                                                                     Quasi-peak                           Average
                             0.15 ~ 0.5                                 66 to 56                           56 to 46
                              0.5 ~ 5                                     56                                 46
                               5 ~ 30                                     60                                 50
           NOTE: 1.The lower limit shall apply at the transition frequencies.
                 2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to
                    0.50MHz.
                    3. All emanations from a class A/B digital device or system, including any network of
                       conductors and apparatus connected thereto, shall not exceed the level of field strengths
                       specified above.

         3.1.2 TEST INSTRUMENTS

       Equipment                  Manufacturer           Model No.            Serial No.      Last Cal.         Next Cal.
       EMI Test Receiver          Rohde&Schwarz          ESR3                 101900          Mar. 15,18        Mar. 14,19
       EMC32 test software        Rohde&Schwarz          EMC32                NA              NA                NA
       LISN network               Rohde&Schwarz          ENV216               101922          Sep. 18,17        Sep. 17,18
           NOTE:
               1. The test was performed in CE shielded room.
               2. The calibration interval of the above test instruments is 12 months and the calibrations are
                    traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 12 of 32


                    Test Report No.: RF180402W006-7

         3.1.3 TEST PROCEDURES

            a. The EUT was placed 0.4 meters from the conducting wall of the shielded room
               with EUT being connected to the power mains through a line impedance
               stabilization network (LISN). Other support units were connected to the power
               mains through another LISN. The two LISNs provide 50 ohm/ 50uH of coupling
               impedance for the measuring instrument.

            b. Both lines of the power mains connected to the EUT were checked for maximum
               conducted interference.

            c. The frequency range from 150kHz to 30MHz was searched. Emission levels
               under (Limit - 20dB) was not recorded.

           NOTE: All modes of operation were investigated and the worst-case emissions are reported.


         3.1.4 DEVIATION FROM TEST STANDARD


           No deviation.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 13 of 32


                    Test Report No.: RF180402W006-7

         3.1.5 TEST SETUP

                                          Vertical G round
                                          Reference Plane                                       Test Receiver


                                           EUT
                             40cm




                                                                   80cm
                             LISN



                                                                                 Horizontal G round
                                                                                 Reference Plane

                               N ote: 1.Support units w ere connected to second LISN.
                                       2.B oth of LISN s (AM N) are 80 cm from EUT and at least 80
                                        from other units and other m etal planes




           For the actual test configuration, please refer to the attached file (Test Setup Photo).

         3.1.6 EUT OPERATING CONDITIONS

              a.    Turned on the power and connected of all equipment.
              b.    EUT was operated according to the type used was description in
                    manufacturer’s specifications or the User's Manual.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 14 of 32


                    Test Report No.: RF180402W006-7

         3.1.7 TEST RESULTS
           CONDUCTED WORST-CASE DATA:
                                                                                        Detector Function &                     Quasi-Peak (QP) /
           Frequency Range                      150KHz ~ 30MHz
                                                                                        Resolution Bandwidth                    Average (AV), 9 kHz
                                                                                        Environmental
           Input Power                          120Vac, 60Hz                                                                    24deg. C, 55RH
                                                                                        Conditions
           Tested By                            John Wen                                TEST DATE                               2018/08/20


             Frequency      QuasiPeak                       CAverage             Limit               Margin                                         Corr.
                                                                                                                     Line            Filter
               (MHz)         (dB¦ÌV)                         (dB¦ÌV)            (dB¦ÌV)               (dB)                                          (dB)
             0.182000          ---         29.31        54.39       -25.08    L1        ON                                                           9.7
             0.182000        47.51           ---        64.39       -16.88    L1        ON                                                           9.7
             0.276000          ---         13.70        50.94       -37.24    L1        ON                                                           9.7
             0.276000        35.75           ---        60.94       -25.19    L1        ON                                                           9.7
             1.016000          ---         14.73        46.00       -31.27    L1        ON                                                           9.7
             1.016000        28.10           ---        56.00       -27.90    L1        ON                                                           9.7
             1.920000          ---         20.08        46.00       -25.92    L1        ON                                                           9.7
             1.920000        32.69           ---        56.00       -23.31    L1        ON                                                           9.7
             3.616000          ---         25.83        46.00       -20.17    L1        ON                                                           9.7
             3.616000        39.66           ---        56.00       -16.34    L1        ON                                                           9.7
             4.548000          ---         32.26        46.00       -13.74    L1        ON                                                           9.7
             4.548000        42.82           ---        56.00       -13.18    L1        ON                                                           9.7
           REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
                    2. "-": The Quasi-peak reading value also meets average limit and
                        measurement with the average detector is unnecessary.
                    3. The emission levels of other frequencies were very low against the limit.
                    4. Margin value = Emission level - Limit value
                    5. Correction factor = Insertion loss + Cable loss
                    6. Emission Level = Correction Factor + Reading Value.

                                                                                    Full Spectrum


                                                80


                                                70


                                                                                                                       FCC PART 15B QP
                                                60


                                                                                                                       FCC PART 15B AV
                                                50
                                 Level in dBµ




                                                40


                                                30


                                                20


                                                10


                                                0
                                                150k         300 400 500   800 1M          2M       3M   4M 5M 6   8 10M       20M       30M
                                                                                     Frequency in Hz



                                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan                   Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan                Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                                                         Email: customerservice.dg@cn.bureauveritas.com
                                                       District, Shenzhen, Guangdong, China
                                                                            Page 15 of 32


                    Test Report No.: RF180402W006-7


                                                                                      Detector Function &                     Quasi-Peak (QP) /
           Frequency Range                      150KHz ~ 30MHz
                                                                                      Resolution Bandwidth                    Average (AV), 9 kHz
                                                                                      Environmental
           Input Power                          120Vac, 60Hz                                                                  24deg. C, 55RH
                                                                                      Conditions
           Tested By                            John Wen                              TEST DATE                               2018/08/20


             Frequency      QuasiPeak                      CAverage           Limit                Margin                                          Corr.
                                                                                                                  Line            Filter
               (MHz)         (dB¦ÌV)                        (dB¦ÌV)          (dB¦ÌV)                (dB)                                           (dB)
              0.194000           ---                          34.32               53.86             -19.54          N               ON             10.0
              0.194000          48.31                          ---                63.86             -15.55          N               ON             10.0
              0.244000           ---                          26.49               51.96             -25.47          N               ON              9.9
              0.244000          43.10                          ---                61.96             -18.86          N               ON              9.9
              0.496000           ---                          23.65               46.07             -22.42          N               ON             10.1
              0.496000          38.93                          ---                56.07             -17.14          N               ON             10.1
              1.580000           ---                          23.68               46.00             -22.32          N               ON              9.9
              1.580000          37.26                          ---                56.00             -18.74          N               ON              9.9
              3.636000           ---                          25.22               46.00             -20.78          N               ON              9.8
              3.636000          38.79                          ---                56.00             -17.21          N               ON              9.8
              4.416000           ---                          30.80               46.00             -15.20          N               ON              9.8
              4.416000          40.87                          ---                56.00             -15.13          N               ON              9.8

           REMARKS: 1. Q.P. and AV. are abbreviations of quasi-peak and average individually.
                  2. "-": The Quasi-peak reading value also meets average limit and
                      measurement with the average detector is unnecessary.
                  3. The emission levels of other frequencies were very low against the limit.
                  4. Margin value = Emission level - Limit value
                  5. Correction factor = Insertion loss + Cable loss
                  6. Emission Level = Correction Factor + Reading Value.
                                                                                   Full Spectrum


                                               80


                                               70


                                                                                                                      FCC PART 15B QP
                                               60


                                                                                                                      FCC PART 15B AV
                                               50
                                Level in dBµ




                                               40


                                               30


                                               20


                                               10


                                               0
                                               150k        300 400 500   800 1M           2M       3M   4M 5M 6   8 10M         20M     30M
                                                                                    Frequency in Hz




                                                      No.B102, Dazu Chuangxin Mansion, North of Beihuan                   Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                                      Avenue, North Area, Hi-Tech Industrial Park, Nanshan                Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                                                        Email: customerservice.dg@cn.bureauveritas.com
                                                      District, Shenzhen, Guangdong, China
                                                                          Page 16 of 32


                    Test Report No.: RF180402W006-7


         3.2 20DB AND 99% BANDWIDTH MEASUREMENT

         3.2.1 LIMITS
            Intentional radiators must be designed to ensure that the 20dB bandwidth of the
         emission in the specific band

         3.2.2     TEST INSTRUMENTS

       Equipment                Manufacturer         Model No.           Serial No.       Last Cal.        Next Cal.
       Power Meter              ANRITSU              ML2495A             1506002          Mar. 02,18       Mar. 01,19
       EXA Signal Analyzer      KEYSIGHT             N9010A-526          MY54510322       Mar. 16,18       Mar. 15,19
       EXA Signal Analyzer      KEYSIGHT             N9010A-544          MY54510355       Mar. 16,18       Mar. 15,19
       Power Sensor             ANRITSU              MA2411B             1339352          Mar. 16,18       Mar. 15,19
         NOTE:
            1. The calibration interval of the above test instruments is 12 months and the calibrations are
               traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
              2. The test was performed in RF Oven room.



         3.2.3     TEST PROCEDURE

         1.    The transmitter output port was connected to the spectrum analyzer.
         2.    Measured the spectrum width with highest power setting.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 17 of 32


                    Test Report No.: RF180402W006-7


         3.2.4     DEVIATION FROM TEST STANDARD

           No deviation.



         3.2.5     TEST SETUP


                         EUT                                                    SPECTRUM
                                                                                 ANALYZER
                                                   10dB ATTENUATION
                                                   PAD




         3.2.6     EUT OPERATING CONDITIONS

           The software provided by client to enable the EUT under transmission condition
           continuously at lowest, middle and highest channel frequencies individually.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 18 of 32


                    Test Report No.: RF180402W006-7



         3.2.7     TEST RESULTS

            BT-LE (GFSK)
                                        CHANNEL                 20dB                    99%
                 CHANNEL               FREQUENCY             BANDWIDTH               BANDWIDTH                 PASS / FAIL
                                          (MHz)                (MHz)                   (MHz)
                      0                    2402                    1.04                    1.09                    PASS
                     39                    2441                    1.04                    1.09                    PASS
                     78                    2480                    1.05                    1.09                    PASS




                                       20dB                                                       99%OBW




                                       20dB                                                       99%OBW




                                        No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                        Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                             Email: customerservice.dg@cn.bureauveritas.com
                                        District, Shenzhen, Guangdong, China
                                                            Page 19 of 32


                    Test Report No.: RF180402W006-7


                                       20dB                                                       99%OBW




                                        No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                        Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                             Email: customerservice.dg@cn.bureauveritas.com
                                        District, Shenzhen, Guangdong, China
                                                            Page 20 of 32


                    Test Report No.: RF180402W006-7



         3.3 FIELD STRENGTH OF FUNDAMENTAL EMISSIONS AND RADIATED
             SPURIOUS EMISSIONS

         3.3.1 LIMITS
         The field strength measured at 3 meters shall not exceed the limits in the following
         table.
                    FUNDAMENTAL                              FIELD STRENGTH (microvolts/meter)
                     FREQUENCIES
                        (MHz)                         FUNDAMENTAL                              HARMONICS

                         902~928                                50                                     0.5
                       2400~2483.5                              50                                     0.5
                        5725~5875                               50                                     0.5



              Radiated emissions which fall in the restricted bands, as defined in Section
              15.205(a), must also comply with the radiated emission limits specified in Section
              15.209(a).
                     FREQUENCIES                     FIELD STRENGTH                  MEASUREMENT DISTANCE
                        (MHz)                        (microvolts/meter)                    (meters)
                      0.009 ~ 0.490                      2400/F(kHz)                                   300
                      0.490 ~ 1.705                      24000/F(kHz)                                   30
                       1.705 ~ 30.0                             30                                      30
                          30 ~ 88                              100                                       3
                         88 ~ 216                              150                                       3
                        216 ~ 960                              200                                       3
                        Above 960                              500                                       3


              NOTE:
              1. The lower limit shall apply at the transition frequencies.
              2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
              3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on
                 average detector, however, the peak field strength of any emission shall not exceed the
                 maximum permitted average limits, specified above by more than 20dB under any condition of
                 modulation.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 21 of 32


                    Test Report No.: RF180402W006-7

        3.3.2 TEST INSTRUMENTS

        Equipment               Manufacturer         Model No.           Serial No.           Last Cal.         Next Cal.
        3m Semi-anechoic                                                 Euroshieldpn-
                                ETS-LINDGREN 9m*6m*6m                                         Apr. 21,18        Apr. 20,19
        Chamber                                                          CT0001143-1216
        Bilog Antenna           ETS-LINDGREN 3143B                       00161965             Nov. 26,16 Nov. 25,18
        Horn Antenna            ETS-LINDGREN 3117                        00168728             Nov. 26,16 Nov. 25,18
        Loop antenna            Daze         ZN30900A                    0708                 Nov. 20,17 Nov. 19,18
                                             QWH-SL-18-40-
        Horn Antenna
                                N/A          K-SG/QMS-003                15433                Dec. 16,16 Dec. 15,18
        (18GHz-40GHz)
                                             61
        Test Software           E3           V 9.160323                  N/A                  N/A               N/A
                                             ADT_Radiated_
        Test Software           ADT                                      N/A                  N/A               N/A
                                             V7.6.15.9.2
        10dB Attenuator         JFW/USA      50HF-010-SMA                1505                 Jul. 09,18        Jul. 08,19
        MXE EMI Receiver        KEYSIGHT     N9038A-544                  MY54450026           Mar. 16,18        Mar. 15,19
        Signal Pre-Amplifier    EMSI         EMC 9135                    980249               Jul. 09,18        Jul. 08,19
        Signal Pre-Amplifier    EMSI         EMC 012645B                 980257               Jul. 09,18        Jul. 08,19
        Signal Pre-Amplifier    EMSI         EMC 184045B                 980259               Jul. 09,18        Jul. 08,19
         NOTE:     1. The calibration interval of the above test instruments is 12 months or 24 months and the
                      calibrations are traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
                    2. The test was performed in 3m Chamber.
                    3. The FCC Site Registration No. is 525120.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 22 of 32


                    Test Report No.: RF180402W006-7

              3.3.3 TEST PROCEDURES

           a. The EUT was placed on the top of a rotating table 0.8 meters (for below 1GHz) /
              1.5 meters (for above 1GHz) above the ground at 3 meter chamber room for test.
              The table was rotated 360 degrees to determine the position of the highest
              radiation.
           b. The EUT was set 3 meters away from the interference-receiving antenna, which
              was mounted on the top of a variable-height antenna tower.
           c. The antenna is a broadband antenna, and its height is varied from one meter to
              four meters above the ground to determine the maximum value of the field
              strength. Both horizontal and vertical polarizations of the antenna are set to make
              the measurement.
           d. For each suspected emission, the EUT was arranged to its worst case and then
              the antenna was tuned to heights from 1 meter to 4 meters and the rotatable table
              was turned from 0 degrees to 360 degrees to find the maximum reading.
           e. The test-receiver system was set to Peak Detect Function and Specified
              Bandwidth with Maximum Hold Mode.
           f. During the test, each emission was maximized by: having the EUT continuously
              working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and
              considered typical configuration to obtain worst position, manipulating
              interconnecting cables, For battery operated equipment, the equipment tests shall
              be perform using fresh batteries. The turntable was rotated to maximize the
              emission level.

         Note:
         1.    The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
               Quasi-peak detection (QP) at frequency below 1GHz.
         2.    The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3
               MHz for Peak detection (PK) at frequency above 1GHz.
         3.    The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video bandwidth is
               3MHz for RMS Average (Duty cycle < 98%) for Average detection (AV) at frequency above 1GHz,
               then the measurement results was added to a correction factor (10 log(1/duty cycle)).
         4.    The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and the video bandwidth is
               10Hz (Duty cycle ≥ 98%) for Average detection (AV) at frequency above 1GHz.
         5.    All modes of operation were investigated and the worst-case emissions are reported.


         3.3.4       DEVIATION FROM TEST STANDARD

           No deviation



                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 23 of 32


                    Test Report No.: RF180402W006-7

         3.3.5       TEST SETUP

         < Frequency Range below 30MHz >




           < Frequency Range 30MHz~1GHz >

                                                                           Ant. Tower
                                                                                                      1-4m
                                                                                                      Variable
                     EUT&                                  3m
                                                           10m
                     Support Units

                                                   Turn Table

                         80cm


                                                        Ground Plane

                                                        Test Receiver




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 24 of 32


                    Test Report No.: RF180402W006-7


           <Frequency Range above 1GHz>



                                                                              Ant. Tower
                                                                                                         1-4m
                                                                                                         Variable
                        EUT&                                   3m
                        Support Units
                                                   Turn Table
                                                                    Absorber
                           150cm


                                                           Ground Plane
                                                            Test
                                                            Receiver



         For the actual test configuration, please refer to the attached file (Test Setup Photo).


         3.3.6       EUT OPERATING CONDITIONS

         a. Set the EUT under full load condition and placed them on a testing table.
         b. Set the transmitter part of EUT under transmission condition continuously at
            specific channel frequency.
         c. The necessary accessories enable the EUT in full functions.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 25 of 32


                    Test Report No.: RF180402W006-7


         3.3.7       TEST RESULTS
         BELOW 1GHz WORST-CASE DATA:

         9 KHz – 30 MHz data: the amplitude of spurious emissions attenuated more than 20 dB below the
         permissible value is not required in the report.

         30 MHz – 1GHz data:

          CHANNEL                      TX Channel 78                DETECTOR
                                                                                                   Quasi-Peak (QP)
          FREQUENCY RANGE              30MHz ~ 1GHz                 FUNCTION


                               ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                     EMISSION READ                               ANTENNA CABLE PREAMP ANTENNA TABLE
           FREQ.                       LIMIT  MARGIN
                      LEVEL   LEVEL                               FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
           (MHz)                     (dBuV/m)  (dB)
                     (dBuV/m) (dBuV)                               (dB /m)  (dB)  (dB)  (cm)  (Degree)
          108.56     26.72    54.39     43.5    -16.78       7.7       1.6  36.97     200         0        QP
          211.06     30.89    54.59     43.5    -12.61     10.61       2.23 36.54     200         0        QP
          315.63     31.55    51.63      46     -14.45     13.66       2.79 36.53     200         0        QP
          421.19     38.38    54.48      46      -7.62     17.45       3.22 36.77     200         0        QP
          467.88     34.27    49.78      46     -11.73     18.01       3.36 36.88     200         0        QP
          603.12     34.46     47.3      46     -11.54     20.39       4.02 37.25     200         0        QP
         REMARKS:
              1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
              2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
              3. The other emission levels were very low against the limit.
              4. Margin value = Emission Level – Limit value




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 26 of 32


                    Test Report No.: RF180402W006-7



          CHANNEL                      TX Channel 78                DETECTOR
                                                                                                   Quasi-Peak (QP)
          FREQUENCY RANGE              30MHz ~ 1GHz                 FUNCTION


                                 ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                     EMISSION READ                               ANTENNA CABLE PREAMP ANTENNA TABLE
           FREQ.                       LIMIT  MARGIN
                      LEVEL   LEVEL                               FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
           (MHz)                     (dBuV/m)  (dB)
                     (dBuV/m) (dBuV)                               (dB /m)  (dB)  (dB)  (cm)  (Degree)
          78.96      29.97    59.13      40     -10.03      6.63       1.37 37.16     100         0        QP
          178.98     33.89    58.61     43.5     -9.61      9.92       2.05 36.69     100         0        QP
          245.13     36.14    58.06      46      -9.86     12.18       2.42 36.52     100         0        QP
          345.36     32.14    50.91      46     -13.86     14.91       2.92 36.6      100         0        QP
          414.11      40.5    56.69      46       -5.5     17.37       3.19 36.75     100         0        QP
          565.74     34.33    48.01      46     -11.67     19.65       3.82 37.15     100         0        QP
         REMARKS:
              1. Emission Level(dBuV/m) = Raw Value(dBuV) + Correction Factor(dB/m)
              2. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB) – Pre-Amplifier Factor(dB)
              3. The other emission levels were very low against the limit.
              4. Margin value = Emission Level – Limit value




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 27 of 32


                    Test Report No.: RF180402W006-7



         ABOVE 1GHz TEST DATA:

         Note: For higher frequency, the emission is too low to be detected.

          CHANNEL                      TX Channel 0                      DETECTOR                  Peak (PK)
          FREQUENCY RANGE              1GHz ~ 25GHz                      FUNCTION                  Average (AV)


                               ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                     EMISSION READ                               ANTENNA CABLE PREAMP ANTENNA TABLE
           FREQ.                       LIMIT  MARGIN
                      LEVEL   LEVEL                               FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
           (MHz)                     (dBuV/m)  (dB)
                     (dBuV/m) (dBuV)                               (dB /m)  (dB)  (dB)  (cm)  (Degree)
            2400       48.15      53.02 54     -5.85  32.88   8.17   45.92   110                                       25       Average
            2400       54.59      59.46 74   -19.41   32.88   8.17   45.92   110                                       25        Peak
            2402       73.71      78.58 94   -20.27   32.88   8.17   45.92   110                                       25       Average
            2402       95.91     100.78 114  -18.09   32.88   8.17   45.92   110                                       25        Peak
           2483.5      45.39     49.98  54     -8.61  32.98   8.32   45.89   110                                       25       Average
           2483.5      56.89     61.48  74    -17.11  32.98   8.32   45.89   110                                       25        Peak
                                 ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                     EMISSION READ                               ANTENNA CABLE PREAMP ANTENNA TABLE
           FREQ.                       LIMIT  MARGIN
                      LEVEL   LEVEL                               FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
           (MHz)                     (dBuV/m)  (dB)
                     (dBuV/m) (dBuV)                               (dB /m)  (dB)  (dB)  (cm)  (Degree)
            2400       45.28     50.15      54         -8.72       32.88        8.17     45.92         106             0        Average
            2400       56.98     61.85      74        -17.02       32.88        8.17     45.92         106             0         Peak
            2402       65.48     70.35      94        -28.52       32.88        8.17     45.92         106             0        Average
            2402       86.76     91.63      114       -25.24       32.88        8.17     45.92         106             0         Peak
           2483.5      45.23     49.82      54         -8.77       32.98        8.32     45.89         106             0        Average
           2483.5      57.27     61.86      74        -16.73       32.98        8.32     45.89         106             0         Peak
         REMARKS:
                1. Emission Level = Read Level+ Antenna Factor + Cable Loss- Preamp Factor
                   Margin value = Emission level – Limit value.
                2. 2402MHz: Fundamental frequency.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 28 of 32


                    Test Report No.: RF180402W006-7


          CHANNEL                      TX Channel 39                 DETECTOR                      Peak (PK)
          FREQUENCY RANGE              1GHz ~ 25GHz                  FUNCTION                      Average (AV)


                               ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                     EMISSION READ                               ANTENNA CABLE PREAMP ANTENNA TABLE
           FREQ.                       LIMIT  MARGIN
                      LEVEL   LEVEL                               FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
           (MHz)                     (dBuV/m)  (dB)
                     (dBuV/m) (dBuV)                               (dB /m)  (dB)  (dB)  (cm)  (Degree)
            2400       51.46     56.33  54    -2.54   32.88   8.17   45.92   109                                      116       Average
            2400        55       59.87  74     -19    32.88   8.17   45.92   109                                      116        Peak
            2441       69.09     73.83  94   -24.91   32.93   8.24   45.91   109                                      116       Average
            2441       90.29     95.03  114  -23.71   32.93   8.24   45.91   109                                      116        Peak
           2483.5      45.44     50.03  54    -8.56   32.98   8.32   45.89   109                                      116       Average
           2483.5      56.87     61.46  74   -17.13   32.98   8.32   45.89   109                                      116        Peak
                                 ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                     EMISSION READ                   ANTENNA CABLE PREAMP ANTENNA TABLE
           FREQ.                       LIMIT  MARGIN
                      LEVEL   LEVEL                   FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
           (MHz)                     (dBuV/m)  (dB)
                     (dBuV/m) (dBuV)                   (dB /m)  (dB)  (dB)  (cm)  (Degree)
           2400   47.64     52.51     54       -6.36      32.88  8.17   45.92     111                                 113       Average
           2400   55.37     60.24     74      -18.63      32.88  8.17   45.92     111                                 113        Peak
           2441    70.4     75.14     94       -23.6      32.93  8.24   45.91     111                                 113       Average
           2441   91.66      96.4    114      -22.34      32.93  8.24   45.91     111                                 113        Peak
          2483.5  45.52     50.11     54       -8.48      32.98  8.32   45.89     111                                 113       Average
          2483.5   57.6     62.19     74       -16.4      32.98  8.32   45.89     111                                 113        Peak
         REMARKS:
                 1. Emission Level = Read Level+ Antenna Factor + Cable Loss- Preamp Factor
                    Margin value = Emission level – Limit value.
                      2. 2441MHz: Fundamental frequency.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 29 of 32


                    Test Report No.: RF180402W006-7


          CHANNEL                      TX Channel 78                    DETECTOR                    Peak (PK)
          FREQUENCY RANGE              1GHz ~ 25GHz                     FUNCTION                    Average (AV)


                               ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                     EMISSION READ                               ANTENNA CABLE PREAMP ANTENNA TABLE
           FREQ.                       LIMIT  MARGIN
                      LEVEL   LEVEL                               FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
           (MHz)                     (dBuV/m)  (dB)
                     (dBuV/m) (dBuV)                               (dB /m)  (dB)  (dB)  (cm)  (Degree)
            2400       44.88      49.75 54    -9.12   32.88   8.17   45.92   103                                       46       Average
            2400        54.8      59.67 74    -19.2   32.88   8.17   45.92   103                                       46        Peak
            2480       74.04      78.65 94   -19.96   32.98   8.31   45.9    103                                       46       Average
            2480       97.48     102.09 114  -16.52   32.98   8.31   45.9    103                                       46        Peak
           2483.5      45.25     49.84  54    -8.75   32.98   8.32   45.89   103                                       46       Average
           2483.5      57.05     61.64  74   -16.95   32.98   8.32   45.89   103                                       46        Peak
                                 ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                     EMISSION READ                               ANTENNA CABLE PREAMP ANTENNA TABLE
           FREQ.                       LIMIT  MARGIN
                      LEVEL   LEVEL                               FACTOR   LOSS FACTOR HEIGHT  ANGLE REMARK
           (MHz)                     (dBuV/m)  (dB)
                     (dBuV/m) (dBuV)                               (dB /m)  (dB)  (dB)  (cm)  (Degree)
            2400       46.67      51.54     54         -7.33       32.88        8.17     45.92         108             42       Average
            2400       54.54      59.41     74        -19.46       32.88        8.17     45.92         108             42        Peak
            2480       75.31      79.92     94        -18.69       32.98        8.31     45.9          108             42       Average
            2480       97.51     102.12     114       -16.49       32.98        8.31     45.9          108             42        Peak
           2483.5      44.99     49.58      54         -9.01       32.98        8.32     45.89         108             42       Average
           2483.5      56.24     60.83      74        -17.76       32.98        8.32     45.89         108             42        Peak
         REMARKS:
                     1. Emission Level = Read Level+ Antenna Factor + Cable Loss- Preamp Factor
                        Margin value = Emission level – Limit value.
                     2. 2480MHz: Fundamental frequency.




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 30 of 32


                    Test Report No.: RF180402W006-7



         4 PHOTOGRAPHS OF THE TEST CONFIGURATION

           Please refer to the attached file (Test Setup Photo).




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 31 of 32


                    Test Report No.: RF180402W006-7



         5 APPENDIX A - MODIFICATIONS RECORDERS FOR ENGINEERING
            CHANGES TO THE EUT BY THE LAB

           No any modifications are made to the EUT by the lab during the test.




           ---END---




                                       No.B102, Dazu Chuangxin Mansion, North of Beihuan      Tel: +86 755 8869 6566
BV 7Layers Communications Technology
                                       Avenue, North Area, Hi-Tech Industrial Park, Nanshan   Fax: +86 755 8869 6577
(Shenzhen) Co. Ltd                                                                            Email: customerservice.dg@cn.bureauveritas.com
                                       District, Shenzhen, Guangdong, China
                                                           Page 32 of 32



Document Created: 2019-05-11 22:22:37
Document Modified: 2019-05-11 22:22:37

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC