LCS190415047AEA_WPT_18_Report

FCC ID: 2AN4YCTVK09

Test Report

Download: PDF
FCCID_4258341

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AN4YCTVK09             Report No.: LCS190415047AEA




                                                 FCC TEST REPORT
                                                                For
                         SHENZHEN TORRAS TECHNOLOGY CO., LTD.
                                   WIRELESS CAR CHARGER MOUNT
                                                 Test Model: CTVK09




   Prepared for                              :   SHENZHEN TORRAS TECHNOLOGY CO., LTD.
                                                 17F, BLOCK C, ZHANTAO TECHNOLOGY BUILDING,
   Address                                   :
                                                 MINZHI ROAD, LONGHUA DISTRICT, SHENZHEN, CHINA.

   Prepared by                               :   Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                 1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue,
   Address                                   :
                                                 Bao’an District, Shenzhen, Guangdong, China
   Tel                                       :   (+86)755-82591330
   Fax                                       :   (+86)755-82591332
   Web                                       :   www.LCS-cert.com
   Mail                                      :   webmaster@LCS-cert.com

   Date of receipt of test sample            :   April 16, 2019
   Number of tested samples                  :   1
   Serial number                             :   Prototype
   Date of Test                              :   April 16, 2019 ~ April 19, 2019
   Date of Report                            :   April 25, 2019




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 1 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                          FCC ID: 2AN4YCTVK09          Report No.: LCS190415047AEA


                                                         FCC TEST REPORT
                                                        FCC CFR 47 PART 18

 Report Reference No. ................ : LCS190415047AEA

 Date Of Issue ................................. : April 25, 2019

 Testing Laboratory Name ............ : Shenzhen LCS Compliance Testing Laboratory Ltd.

                                                        1/F., Xingyuan Industrial Park, Tongda Road, Bao’an Avenue,
 Address .......................................... :
                                                        Bao’an District, Shenzhen, Guangdong, China
                                                        Full application of Harmonised standards ■
                                                    :
 Testing Location/ Procedure ..........                 Partial application of Harmonised standards □
                                                        Other standard testing method □

 Applicant’s Name ......................... : SHENZHEN TORRAS TECHNOLOGY CO., LTD.
                                                        17F, BLOCK C, ZHANTAO TECHNOLOGY BUILDING, MINZHI
 Address .......................................... :
                                                        ROAD, LONGHUA DISTRICT, SHENZHEN, CHINA.

 Test Specification

 Standard ......................................... : FCC CFR 47 PART 18

 Test Report Form No. .................... : LCSEMC-1.0

 TRF Originator................................ : Shenzhen LCS Compliance Testing Laboratory Ltd.

 Master TRF .................................... : Dated 2011-03
 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
 This publication may be reproduced in whole or in part for non-commercial purposes as long as the
 Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of
 the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not
 assume liability for damages resulting from the reader's interpretation of the reproduced material due to
 its placement and context.
 Test Item Description................... : WIRELESS CAR CHARGER MOUNT

 Trade Mark ..................................... : TORRAS

 Test Model ...................................... : CTVK09

                                                        Input: 5.0V     2.0A/9V     2.0A /12V          1.5A
 Power Supply ................................. :
                                                        Output: 5W/7.5W/10W
 Result ........................................... : Positive


              Compiled by:                                     Supervised by:                            Approved by:




   Raing Ye/ File administrators                    Calvin Weng / Technique principal               Gavin Liang/ Manager




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 2 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AN4YCTVK09        Report No.: LCS190415047AEA




                                                              FCC TEST REPORT

                                                                                                 April 25, 2019
   Test Report No. :                                LCS190415047AEA
                                                                                                 Date of issue



    Test Model..............................          : CTVK09

    EUT.........................................      : WIRELESS CAR CHARGER MOUNT

    Applicant...............................          : SHENZHEN TORRAS TECHNOLOGY CO., LTD.
                                                        17F, BLOCK C, ZHANTAO TECHNOLOGY BUILDING, MINZHI
    Address..................................         :
                                                        ROAD, LONGHUA DISTRICT, SHENZHEN, CHINA.
    Telephone...............................          : /
    Fax..........................................     : /


    Manufacturer........................              : SHENZHEN TORRAS TECHNOLOGY CO., LTD.
                                                        17F, BLOCK C, ZHANTAO TECHNOLOGY BUILDING, MINZHI
    Address...................................        :
                                                        ROAD, LONGHUA DISTRICT, SHENZHEN, CHINA.
    Telephone...............................          : /
    Fax..........................................     : /


    Factory...................................        :   /
    Address...................................        :   /
    Telephone...............................          :   /
    Fax..........................................     :   /




                                 Test Result                                                     Positive


    The test report merely corresponds to the test sample.
    It is not permitted to copy extracts of these test result without the written permission of the test
    laboratory.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 3 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AN4YCTVK09             Report No.: LCS190415047AEA


                                                    Revision History
          Revision                        Issue Date                          Revisions                        Revised By
            000                          April 25, 2019                      Initial Issue                     Gavin Liang




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 4 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                    FCC ID: 2AN4YCTVK09                      Report No.: LCS190415047AEA


                                                      TABLE OF CONTENTS

    1. GENERAL INFORMATION ......................................................................................................... 6
       1.1 Description of Device (EUT) .............................................................................................................. 6
       1.2 Support equipment List ....................................................................................................................... 6
       1.3 External I/O Cable ............................................................................................................................... 6
       1.4 Description of Test Facility ................................................................................................................. 6
       1.5 Statement of the Measurement Uncertainty .................................................................................... 7
       1.6 Measurement Uncertainty .................................................................................................................. 7
       1.7 Description of Test Modes.................................................................................................................. 7
    2. TEST METHODOLOGY .............................................................................................................. 8
       2.1 EUT Configuration ............................................................................................................................... 8
       2.2 EUT Exercise........................................................................................................................................ 8
       2.3 General Test Procedures ................................................................................................................... 8
       2.3.1 Conducted Emissions ...................................................................................................................... 8
       2.3.2 Radiated Emissions ......................................................................................................................... 8
    3. SYSTEM TEST CONFIGURATION ........................................................................................... 9
       3.1 Justification ........................................................................................................................................... 9
       3.2 EUT Exercise Software ....................................................................................................................... 9
       3.3 Special Accessories ............................................................................................................................ 9
       3.4 Block Diagram/Schematics ................................................................................................................ 9
       3.5 Equipment Modifications .................................................................................................................... 9
       3.6 Test Setup............................................................................................................................................. 9
    4. SUMMARY OF TEST EQUIPMENT ........................................................................................ 10
    5. SUMMARY OF TEST RESULT ................................................................................................ 11
    6. POWER LINE CONDUCTED MEASUREMENT (NOT APPLICABLE) ............................ 12
    7. RADIATED EMISSION MEASUREMENT .............................................................................. 13
       7.1. Block Diagram of Test Setup .......................................................................................................... 13
       7.2. Radiated Emission Limit .................................................................................................................. 14
       7.3. EUT Configuration on Measurement ............................................................................................. 14
       7.4. Operating Condition of EUT ............................................................................................................ 14
       7.5. Measuring Setting ............................................................................................................................. 14
       7.6. Test Procedure ................................................................................................................................. 15
       7.7. Test Results....................................................................................................................................... 16
    8. PHOTOGRAPHS OF TEST SETUP ........................................................................................ 19
    9. EXTERNAL PHOTOGRAPHS OF THE EUT ......................................................................... 19
    10. INTERNAL PHOTOGRAPHS OF THE EUT ........................................................................ 19




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                         Page 5 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AN4YCTVK09             Report No.: LCS190415047AEA


1. GENERAL INFORMATION

   1.1 Description of Device (EUT)

        EUT                                            :     WIRELESS CAR CHARGER MOUNT
        Test Model                                     :     CTVK09
        Hardware Version                               :     V1.0
        Software Version                               :     V1.0
        Operating Frequency                            :     110-205 KHz
        Modulation Type                                :     CW
        Antenna Type                                   :     Coil Antenna

        Input/output                                   :     Input: 5.0V   2.0A/9V              2.0A /12V         1.5A
                                                             Output: 5W/7.5W/10W
        Maximum Rated Power of WPT                     :     10W


   1.2 Support equipment List

          Manufacturer                       Description                      Model             Serial Number Certificate
              Apple                         Mobile Phone                    iPhone X                   --      FCC ID
       Shenzhen Huakexun
                                             Car Charger             CHY-CC-U2CQ3M                      --              SDOC
       Electronics Co., Ltd.

   1.3 External I/O Cable

               I/O Port Description                          Quantity                               Cable
                    USB Port                                   1                               1.0m, unshielded


   1.4 Description of Test Facility
    FCC Registration Number is 254912.
    Industry Canada Registration Number is 9642A-1.
    EMSD Registration Number is ARCB0108.
    UL Registration Number is 100571-492.
    TUV SUD Registration Number is SCN1081.
    TUV RH Registration Number is UA 50296516-001.
    NVLAP Accreditation Code is 600167-0.
    FCC Designation Number is CN5024.
    CAB identifier: CN0071
    The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.4:2014 and CISPR
    16-1-4:2010 SVSWR requirement for radiated emission above 1GHz.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 6 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AN4YCTVK09             Report No.: LCS190415047AEA

   1.5 Statement of the Measurement Uncertainty
    The data and results referenced in this document are true and accurate. The reader is cautioned that
    there may be errors within the calibration limits of the equipment and facilities. The measurement
    uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 – 4
    “Specification for radio disturbance and immunity measuring apparatus and methods – Part 4:
    Uncertainty in EMC Measurements” and is documented in the LCS quality system acc. To DIN EN
    ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may
    result in additional deviation. The manufacturer has the sole responsibility of continued compliance of
    the device.

   1.6 Measurement Uncertainty

                    Test Item                       Frequency Range                      Uncertainty                Note
                                                      9KHz~30MHz                          3.10dB                     (1)
                                                    30MHz~200MHz                          2.96dB                     (1)
            Radiation Uncertainty           :      200MHz~1000MHz                         3.10dB                     (1)
                                                     1GHz~26.5GHz                         3.80dB                     (1)
                                                    26.5GHz~40GHz                         3.90dB                     (1)
           Conduction Uncertainty :                  150kHz~30MHz                         1.63dB                     (1)
             Power disturbance    :                 30MHz~300MHz                          1.60dB                     (1)

    (1). This uncertainty represents an expanded uncertainty expressed at approximately the 95%
    confidence level using a coverage factor of k=2.

   1.7 Description of Test Modes
    Equipment under test was operated during the measurement under the following conditions:
         Charging and communication mode
    Modulation Type: CW (Continuous Wave)

 Test Modes:
 Mode 1 Car Charge (12V/1.5A) + EUT + Mobile Phone iPhone X (Battery Status: <1%)                                        Record
 Mode 2 Car Charge (12V/1.5A) + EUT + Mobile Phone iPhone X (Battery Status: <50%)                                       Pre-tested
 Mode 3 Car Charge (12V/1.5A) + EUT + Mobile Phone iPhone X (Battery Status: 100%)                                       Pre-tested
 Mode 4 Car Charge (5V/2A) + EUT + Mobile Phone iPhone X (Battery Status: <1%)                                           Pre-tested
 Mode 5 Car Charge (5V/2A) + EUT + Mobile Phone iPhone X (Battery Status: <50%)                                          Pre-tested
 Mode 6 Car Charge (5V/2A) + EUT + Mobile Phone iPhone X (Battery Status: 100%)                                          Pre-tested
 Note: All test modes were pre-tested, but we only recorded the worst case in this report.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 7 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AN4YCTVK09             Report No.: LCS190415047AEA


2. TEST METHODOLOGY
    The tests documented in this report were performed in accordance with MP-5, and FCC CFR PART
    18.

   2.1 EUT Configuration
    The EUT configuration for testing is installed on RF field strength measurement to meet the
    Commissions requirement and operating in a manner that intends to maximize its emission
    characteristics in a continuous normal application.

   2.2 EUT Exercise
    The EUT was operated in the charging and compunction mode to fix the TX frequency that was for the
    purpose of the measurements.
    According to its specifications, the EUT must comply with the requirements of the Section 18.305 and
    18.307 under the FCC Rules Part 18.

   2.3 General Test Procedures

   2.3.1 Conducted Emissions
    The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the requirements
    in FCC MP-5 for Conducted emissions from the EUT measured in the frequency range between 0.15
    MHz and 30MHz using Quasi-peak and average detector modes.

   2.3.2 Radiated Emissions
    The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall rotate 360
    degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving
    antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to
    be maximized by changing the polarization of receiving antenna both horizontal and vertical. In order
    to find out the maximum emissions, exploratory radiated emission measurements were made
    according to the requirements in FCC MP-5 for radiated emission.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 8 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AN4YCTVK09             Report No.: LCS190415047AEA


3. SYSTEM TEST CONFIGURATION

   3.1 Justification
    The system was configured for testing in a normal condition.

   3.2 EUT Exercise Software
    N/A.

   3.3 Special Accessories
    N/A.

   3.4 Block Diagram/Schematics
    Please refer to the related document.

   3.5 Equipment Modifications
    Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT.

   3.6 Test Setup
    Please refer to the test setup photo.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 9 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN4YCTVK09             Report No.: LCS190415047AEA


4. SUMMARY OF TEST EQUIPMENT

Item            Equipment                Manufacturer    Model No.      Serial No.    Last Cal.                             Next Cal.
   1       MXA Signal Analyzer              Agilent       N9020A      MY49100040     2018-06-16                            2019-06-15
   2    SPECTRUM ANALYZER                    R&S            FSP          100503      2018-06-16                            2019-06-15
   3 3m Semi Anechoic Chamber SIDT FRANKONIA              SAC-3M       03CH03-HY     2018-06-16                            2019-06-15
   4      Positioning Controller             MF          MF-7082             /       2018-06-16                            2019-06-15
   5        EMI Test Software               AUDIX            E3         ROMOSS       2018-06-16                            2019-06-15
   6        EMI Test Receiver                R&S           ESR 7           N/A          N/A                                   N/A
   7            AMPLIFIER                  QuieTek     QTK-A2525G    CHM10809065     2018-11-16                            2019-11-15
   8       Active Loop Antenna         SCHWARZBECK     FMZB 1519B         00005      2018-06-22                            2019-06-21
   9         By-log Antenna            SCHWARZBECK      VULB9163        9163-470     2018-05-01                            2019-04-30
  10          Horn Antenna             SCHWARZBECK     BBHA 9120 D     9120D-1925    2018-07-02                            2019-07-01
  11         RF Cable-R03m                 Jye Bao        RG142          CB021       2018-06-16                            2019-06-15
  12         RF Cable-HIGH                SUHNER      SUCOFLEX 106     03CH03-HY     2018-06-16                            2019-06-15
  13        TEST RECEIVER                    R&S           ESPI          101142      2018-06-16                            2019-06-15
  14         RF Cable-CON                 UTIFLEX      3102-26886-4      CB049       2018-06-16                            2019-06-15
  15         10dB Attenuator           SCHWARZBECK     MTS-IMP136 261115-001-0032 2018-06-16                               2019-06-15
  16          Artificial Mains               R&S          ENV216         101288      2018-06-16                            2019-06-15
Note: All equipment is calibrated through GUANGZHOU LISAI CALIBRATION AND TEST CO.,LTD.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                              Page 10 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN4YCTVK09             Report No.: LCS190415047AEA


5. SUMMARY OF TEST RESULT

                         FCC Rule         Temperature          Power source
   Test Item                                                                         C        NC          NA         NP        Remark
                           No.             conditions           conditions
   Radiated
                        §18.305 (b)          Nominal              Nominal                                                         -/-
   Emission
 AC conducted
                        §18.307 (a)          Nominal              Nominal                                                         -/-
   emission

Remark: The measurement uncertainty is not included in the test result.
N/A – Not Applicable!!!




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                              Page 11 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AN4YCTVK09             Report No.: LCS190415047AEA


6. POWER LINE CONDUCTED MEASUREMENT (NOT APPLICABLE)

6.1. Block Diagram of Test Setup




6.2. Standard Applicable
   According to §18.307 (b): For all other part 18 consumer devices which is designed to be connected to
   the public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power
   line on any frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250
   microvolts (The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to
   0.50 MHz). The limits at specific frequency range are listed as follows:

          Frequency Range                                                      Limits (dBμV)
                (MHz)                                     Quasi-peak                                      Average
             0.15 to 0.50                                  66 to 56                                       56 to 46
               0.50 to 5                                     56                                             46
                5 to 30                                      60                                             50

        * Decreasing linearly with the logarithm of the frequency


6.3 Test Results

   Not Applicable!!!

   The device powered by Car Charge and used at Car!!!




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 12 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AN4YCTVK09             Report No.: LCS190415047AEA


7. RADIATED EMISSION MEASUREMENT

   7.1. Block Diagram of Test Setup




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 13 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN4YCTVK09             Report No.: LCS190415047AEA

   7.2. Radiated Emission Limit
     Except as provided elsewhere in this Subpart 18.305 (b), the field strength levels of emissions which
     lie outside the bands specified in §18.301, unless otherwise indicated, shall not exceed the following
     table:

                     Frequency                          Distance                     Field Strengths Limit
                         MHz                             Meters                   dBV/m             Remark
                   0.009~30MHz                              3                      103.5           Quasi-peak
                       30~88                                3                      40.0            Quasi-peak
                      88~216                                3                      43.5            Quasi-peak
                       216~960                              3                      46.0            Quasi-peak
                      960~1000                              3                      54.0            Quasi-peak

Remark:
(1) Emission level dBV/m for 0.009~30MHz = 20log (15) + 40log (300/3) dBV/m;
(2) Calculated according FCC 18.305.
(3) The smaller limit shall apply at the cross point between two frequency bands.
(4) Distance is the distance in meters between the measuring instrument, antenna and the closest point of
any part of the device or system.

   7.3. EUT Configuration on Measurement

The following equipment are installed on Radiated Emission Measurement to meet the commission
requirements and operating regulations in a manner which tends to maximize its emission characteristics in
normal application.

   7.4. Operating Condition of EUT

(1) Setup the EUT as shown in Section 4.1.

(2) Let the EUT work in worst test mode (Mode 1) and measure it.

   7.5. Measuring Setting
     The following table is the setting of spectrum analyzer and receiver.

          Receiver Parameter                                     Setting
          Attenuation                                            Auto
          Start ~ Stop Frequency                                 9kHz~150kHz / RB 200Hz for QP/Average
          Start ~ Stop Frequency                                 150kHz~30MHz / RB 9kHz for QP/Average
          Start ~ Stop Frequency                                 30MHz~1000MHz / RB 100kHz for QP




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                              Page 14 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AN4YCTVK09             Report No.: LCS190415047AEA

   7.6. Test Procedure


    1) Sequence of testing 9 kHz to 30 MHz
    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or
    described by manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions.
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.
    Premeasurement:
    --- The turntable rotates from 0°to 315°using 45°steps.
    --- The antenna height is 0.8 meter.
    --- At each turntable position the analyzer sweeps with peak detection to find the maximum of all
    emissions
    Final measurement:
    --- Identified emissions during the premeasurement the software maximizes by rotating the turntable
    position (0°to 360°) and by rotating the elevation axes (0°to 360°).
    --- The final measurement will be done in the position (turntable and elevation) causing the highest
    emissions with QPK detector.
    --- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin
    to the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit
    will be stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 15 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN4YCTVK09             Report No.: LCS190415047AEA




     2) Sequence of testing 30 MHz to 1 GHz
     Setup:
     --- The equipment was set up to simulate a typical usage like described in the user manual or
     described by manufacturer.
     --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground
     plane.
     --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
     --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
     --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
     --- The measurement distance is 3 meter.
     --- The EUT was set into operation.
     Premeasurement:
     --- The turntable rotates from 0°to 315°using 45°steps.
     --- The antenna is polarized vertical and horizontal.
     --- The antenna height changes from 1 to 3 meter.
     --- At each turntable position, antenna polarization and height the analyzer sweeps three times in peak
     to find the maximum of all emissions.
     Final measurement:
     --- The final measurement will be performed with minimum the six highest peaks.
     --- According to the maximum antenna and turntable positions of premeasurement the software
     maximize the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4
     meter.
     --- The final measurement will be done with QP detector with an EMI receiver.
     --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization,
     turntable angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the
     graph of the premeasurement with marked maximum final measurements and the limit will be stored.


   7.7. Test Results

    PASS.

Only report the worst test data (Mode 1) in test report;

The test data please refer to following page:

             Temperature                        24.1℃                       Humidity                         52.7%
             Test Engineer                     Scent Hu                   Configurations                    Transmit




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                              Page 16 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AN4YCTVK09             Report No.: LCS190415047AEA

0.009 MHz – 30 MHz




Remark: Measured at antenna position 0 degree and 90 degree, recorded worst case at 90 degree.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 17 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AN4YCTVK09             Report No.: LCS190415047AEA

30 MHz – 1000 MHz
          Temperature                           24.1℃                       Humidity                         52.7%
          Test Engineer                        Scent Hu                   Configurations                    Transmit

Horizontal




Vertical




     Note:
     1). Pre-scan all modes and recorded the worst case results in this report.
     2). Emission level (dBuV/m) = 20 log Emission level (uV/m).
     3). Corrected Reading: Antenna Factor + Cable Loss + Read Level = Level.


   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                              Page 18 of 19


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AN4YCTVK09             Report No.: LCS190415047AEA


8. PHOTOGRAPHS OF TEST SETUP

    Please refer to separated files for Test Setup Photos of the EUT.


9. EXTERNAL PHOTOGRAPHS OF THE EUT

    Please refer to separated files for External Photos of the EUT.


10. INTERNAL PHOTOGRAPHS OF THE EUT

    Please refer to separated files for Internal Photos of the EUT.




                              -------------THE END OF REPORT-------------




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                             Page 19 of 19



Document Created: 2019-04-28 02:16:00
Document Modified: 2019-04-28 02:16:00

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC