RF Exposure Info

FCC ID: 2AMZYPOWERMAT

RF Exposure Info

Download: PDF
FCCID_4448295

                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch




                                                                   Report No.: SZEM190701617702
                                                                   Page:       1 of 13


1     COVER PAGE

                      Human Exposure Report
Application No.:          SZEM1907016177CR
Applicant:                HandStandsPromo LLC
Address of Applicant:     1420 S. 4800 W. Suite A Salt Lake City Utah 84104 United States
Manufacturer:             HandStandsPromo LLC
Address of Manufacturer:  1420 S. 4800 W. Suite A Salt Lake City Utah 84104 United States
Factory:                  Amitec Industrial Inc.
Address of Factory:       1706, Rongchao Building A, Haixiu Road 2021, Bao'an District, Shenzhen
                          City, Guangdong Province, China
Equipment Under Test (EUT):
EUT Name:                 Power Mat
Model No.:                76022
Trade mark:               Numi
FCC ID:                   2AMZYPOWERMAT
Standards:                47 CFR PART 1, Subpart I, Section 1.1310
Date of Receipt:          2019-07-10
Date of Test:             2019-07-11 to 2019-07-14
Date of Issue:            2019-08-06
Test Result :               Pass*
* In the configuration tested, the EUT complied with the standards specified above




             Keny Xu
      EMC Laboratory Manager


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                           Report No.: SZEM190701617702
                                                           Page:       2 of 13




                                        Revision Record
    Version        Chapter              Date                  Modifier       Remark

     01                              2019-08-06                              Original




Authorized for issue by:




                             Bill Chen /Project Engineer




                             Eric Fu /Reviewer


                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                             Shenzhen Branch
                                                                                                 Report No.: SZEM190701617702
                                                                                                 Page:       3 of 13




2         Contents


1      COVER PAGE ..................................................................................................................................... 1

2      CONTENTS ......................................................................................................................................... 3

3      GENERAL INFORMATION .................................................................................................................. 4
    3.1    DETAILS OF E.U.T. ............................................................................................................................. 4
    3.2    DESCRIPTION OF SUPPORT UNITS ........................................................................................................ 4
    3.3    TEST LOCATION ................................................................................................................................. 5
    3.4    TEST FACILITY.................................................................................................................................... 5
    3.5    DEVIATION FROM STANDARDS .............................................................................................................. 5
    3.6    ABNORMALITIES FROM STANDARD CONDITIONS...................................................................................... 5
4      EQUIPMENTS USED DURING TEST .................................................................................................. 6

5      TEST RESULTS .................................................................................................................................. 7
    5.1 RF EXPOSURE TEST ........................................................................................................................... 7
       5.1.1 E.U.T. Operation ...................................................................................................................... 7
       5.1.2 Measurement Data .................................................................................................................. 8
6      PHOTOGRAPHS ................................................................................................................................13
    6.1 TEST SETUP PHOTOS .........................................................................................................................13


                                  SGS—CSTC Standards Technical Services Co., Ltd.
                                  Shenzhen Branch
                                                                     Report No.: SZEM190701617702
                                                                     Page:         4 of 18



3      General Information
3.1 Details of E.UL.T.
       Power supply:                Input: DC §V20,0V/1.07A
                                    Oulput:: 10W,7.SW/SW
       Cable                        USB cable: 1150m unshielded
       Antenna Type                Leop Antenna
       Antennc Gain                0dBi
       Modulation Type:            Load Modulation
       Operation Frequency          11522448z to 151.4423kHz
       Remark                      This device has been tested the worst status of full load and the device has
                                    been tested with load at SW,7.SW and 10W,the worst case 1OW is reported
                                    only.

3.2|   Description of Support Units

       Description                  Manufacturer            Model No.                 Serial No.
       iPnone 8                         Aople                 Arses                 FaGvasssicsD
       SANSUNG Gelaxy 5              savsung                SM—Gosoo                 RoEJOMOLPB
            Adapter                  savsune                Ep—TaAzco              RerevarWribke




                                                       en   es                          Sedurenns
                                                         Tt   m enttered wveee hn t ameane
                                                         frgpreceelentertebe               o ne
                                                                                     ievrmem
                         i                  Frwateneonon ce \erminn (rruisinn. weurene
                 Zess,       |on am ememom—srm        mm si momaroe 1 msnn nomiien
                                                                   wenterotiteSa8.Goup 30884


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                               Report No.: SZEM190701617702
                                                               Page:       5 of 13




3.3 Test Location
     All tests were performed at:
     SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch E&E Lab,
     No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong,China
     518057.
     Tel: +86 755 2601 2053         Fax: +86 755 2671 0594
     No tests were sub-contracted.

3.4 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
    been registered in accordance with the Regulations for Voluntary Control Measures with Registration
    No.: G-20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    as an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    CAB identifier: CN0006.
    IC#: 4620C.

3.5 Deviation from Standards
    None.

3.6 Abnormalities from Standard Conditions
    None.


                        SGS-CSTC Standards Technical Services Co., Ltd.
                        Shenzhen Branch
                                                    Report No.: SZEM190701617702
                                                    Page:       6 of 13




4       Equipments Used during Test


                                                                               Cal Due
Item        Equipment   Manufacturer   Model No   Inventory No    Cal Date
                                                                                 Date
    1    EMF Tester     Narda          ELT-400    SZE039-4       2019-07-08   2020-07-07


                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch
                                                                       Report No.: SZEM190701617702
                                                                       Page:       7 of 13




5       Test Results
5.1 RF Exposure test
        Test Requirement:               47 CFR PART 1, Subpart I, Section 1.1310
        Measurement Distance:           0/2/4/6/8/10/15cm
        Limit:

    Frequency range Electric field strength Magnetic field strength Power density Averaging time
         (MHz)               (V/m)                  (A/m)             (mW/cm2)      (minutes)
                             (A) Limits for Occupational/Controlled Exposures
           0.3-3.0                614                         1.63            *(100)              6
           3.0-30                1842/f                       4.89/f         *(900/f 2)           6
           30-300                 61.4                        0.163             1.0               6
          300-1500                  /                           /              f/300              6
        1500-100,000                /                           /                  5              6
                          (B) Limits for General Population/Uncontrolled Exposure
          0.3-1.34                614                         1.63            *(100)             30
           1.34-30               824/f                        2.19/f         *(180/f 2)          30
           30-300                 27.5                        0.073             0.2              30
          300-1500                  /                           /             f/1500             30
        1500-100,000                /                           /               1.0              30
    F=frequency in MHz
    *=Plane-wave equivalent power density
    RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC
    rules. The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits
    for 150kHz:614V/m,1.63A/m).
5.1.1     E.U.T. Operation

        Operating Environment:
        Temperature:     24.0 °C            Humidity:       52 % RH      Atmospheric Pressure: 1015 mbar

        EUT Operation:
        This device has been tested with mobile phone at zero charge, intermediate charge, and full
         charge.


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                          Report No.: SZEM190701617702
                                                          Page:       8 of 13




5.1.2   Measurement Data


        Output Voltage=DC 9V; The max output power =10W
        Magnetic Field Emissions
          Operation     Test Distance   Test Position   Probe Measure   50% Limit
          frequency                                      Result (A/m)
                             (cm)                                         (A/m)
                                           Side 1          0.4049         0.815
                                           Side 2          0.3571         0.815
            122 kHz           0            Side 3          0.3856         0.815
                                           Side 4          0.3614         0.815
                                            Top            0.2938         0.815

        Magnetic Field Emissions
          Operation     Test Distance   Test Position   Probe Measure   50% Limit
          frequency                                      Result (A/m)
                             (cm)                                         (A/m)
                                           Side 1          0.3731         0.815
                                           Side 2          0.3256         0.815
            122 kHz           2            Side 3          0.3528         0.815
                                           Side 4          0.3273         0.815
                                            Top            0.2572         0.815

        Magnetic Field Emissions
          Operation     Test Distance   Test Position   Probe Measure   50% Limit
          frequency                                      Result (A/m)
                             (cm)                                         (A/m)
                                           Side 1          0.3419         0.815
                                           Side 2          0.2892         0.815
            122 kHz           4            Side 3          0.3165         0.815
                                           Side 4          0.2936         0.815
                                            Top            0.2211         0.815


                      SGS-CSTC Standards Technical Services Co., Ltd.
                      Shenzhen Branch
                                                    Report No.: SZEM190701617702
                                                    Page:       9 of 13


Magnetic Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (A/m)
                      (cm)                                          (A/m)
                                     Side 1          0.3081         0.815
                                     Side 2          0.2539         0.815
    122 kHz                6         Side 3          0.2826         0.815
                                     Side 4          0.2597         0.815
                                      Top            0.1834         0.815



Magnetic Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (A/m)
                      (cm)                                          (A/m)
                                     Side 1          0.2747         0.815
                                     Side 2          0.2195         0.815
    122 kHz                8         Side 3          0.2441         0.815
                                     Side 4          0.2258         0.815
                                      Top            0.1502         0.815

Magnetic Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (A/m)
                      (cm)                                          (A/m)
                                     Side 1          0.2387         0.815
                                     Side 2          0.1828         0.815
    122 kHz            10            Side 3          0.2123         0.815
                                     Side 4          0.1886         0.815
                                      Top            0.1174         0.815


Magnetic Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (A/m)
                      (cm)                                          (A/m)


                       SGS-CSTC Standards Technical Services Co., Ltd.
                       Shenzhen Branch
                                                         Report No.: SZEM190701617702
                                                         Page:       10 of 13


                                       Side 1              0.1653             0.815
                                       Side 2              0.1207             0.815
    122 kHz             15             Side 3              0.1533             0.815
                                       Side 4              0.1328             0.815
                                        Top                0.0782             0.815




Mobile phone has been charge at zero charge, intermediate charge, and full charge.

Magnetic Field Emissions

 Operation       Test                           Probe Measure Result(A/m)
                              Test                                               50%Limit
 frequency     Distance
                             Position     zero        intermediate   full
                                          charge         charge      charge           (A/m)
                 (cm)
                              Side 1                                                  0.815
                                           0.4144        0.4003      0.3879
                              Side 2                                                  0.815
                                           0.3667        0.3550      0.3407
  122 kHz          0          Side 3                                                  0.815
                                           0.3951        0.3805      0.3671
                              Side 4                                                  0.815
                                           0.3714        0.3586      0.3442
                               Top                                                    0.815
                                           0.3049        0.2888      0.2762

Magnetic Field Emissions

 Operation       Test                           Probe Measure Result(A/m)
                              Test                                               50%Limit
 frequency     Distance
                             Position     zero        intermediate   full
                                          charge         charge      charge           (A/m)
                 (cm)
  122 kHz          2          Side 1                                                  0.815
                                           0.3862        0.3708      0.3584


                      SGS-CSTC Standards Technical Services Co., Ltd.
                      Shenzhen Branch
                                                  Report No.: SZEM190701617702
                                                  Page:       11 of 13


                            Side 2                                      0.815
                                      0.3368      0.3207      0.3062
                            Side 3                                      0.815
                                      0.3645      0.3544      0.3398
                            Side 4                                      0.815
                                      0.3382      0.3277      0.3125
                             Top                                        0.815
                                      0.2683      0.2541      0.2402



Magnetic Field Emissions

 Operation      Test                    Probe Measure Result(A/m)
                            Test                                       50%Limit
 frequency    Distance
                           Position   zero     intermediate   full
                                      charge      charge      charge    (A/m)
                (cm)
                            Side 1                                      0.815
                                      0.3543      0.3431      0.3305
                            Side 2                                      0.815
                                      0.2988      0.2883      0.2748
  122 kHz         4         Side 3                                      0.815
                                      0.3276      0.3139      0.2991
                            Side 4                                      0.815
                                      0.3057      0.2902      0.2774
                             Top                                        0.815
                                      0.2312      0.2175      0.2043




Magnetic Field Emissions

 Operation      Test                    Probe Measure Result(A/m)
                            Test                                       50%Limit
 frequency    Distance
                           Position   zero     intermediate   full
                                      charge      charge      charge    (A/m)
                (cm)
                            Side 1                                      0.815
                                      0.3172      0.3065      0.2915
                            Side 2                                      0.815
                                      0.2664      0.2532      0.2408
  122 kHz         6         Side 3                                      0.815
                                      0.2925      0.2807      0.2660
                            Side 4                                      0.815
                                      0.2687      0.2569      0.2431
                             Top                                        0.815
                                      0.1922      0.1811      0.1676


                       SGS-CSTC Standards Technical Services Co., Ltd.
                       Shenzhen Branch
                                                   Report No.: SZEM190701617702
                                                   Page:       12 of 13


Magnetic Field Emissions

 Operation      Test                     Probe Measure Result(A/m)
                             Test                                       50%Limit
 frequency    Distance
                            Position   zero     intermediate   full
                                       charge      charge      charge    (A/m)
                (cm)
                             Side 1                                      0.815
                                       0.2835      0.2705      0.2570
                             Side 2                                      0.815
                                       0.2307      0.2191      0.2041
  122 kHz         8          Side 3                                      0.815
                                       0.2573      0.2426      0.2300
                             Side 4                                      0.815
                                       0.2390      0.2229      0.2089
                              Top                                        0.815
                                       0.1625      0.1516      0.1376


Magnetic Field Emissions
 Operation      Test                     Probe Measure Result(A/m)
                             Test                                       50%Limit
 frequency    Distance
                            Position   zero     intermediate   full
                                       charge      charge      charge    (A/m)
                (cm)
                             Side 1                                      0.815
                                       0.2484      0.2334      0.2189
                             Side 2                                      0.815
                                       0.1955      0.1815      0.1665
  122 kHz         10         Side 3                                      0.815
                                       0.2245      0.2085      0.1960
                             Side 4                                      0.815
                                       0.1984      0.1871      0.1730
                              Top                                        0.815
                                       0.1269      0.1146      0.1013


Magnetic Field Emissions
 Operation      Test                     Probe Measure Result(A/m)
                             Test                                       50%Limit
 frequency    Distance
                            Position   zero     intermediate   full
                                       charge      charge      charge    (A/m)
                (cm)
                             Side 1                                      0.815
                                       0.1753      0.1597      0.1446
                             Side 2                                      0.815
                                       0.1305      0.1194      0.1055
  122 kHz         15         Side 3                                      0.815
                                       0.1636      0.1498      0.1363
                             Side 4                                      0.815
                                       0.1450      0.1342      0.1209
                              Top                                        0.815
                                       0.0910      0.0780      0.0643


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                                   Report No.: SZEM190701617702
                                                                   Page:       13 of 13



6    Photographs
6.1 Test setup photos
Please refer to RF Exposure Setup Photos




     .




                                           - End of the Report -



Document Created: 2019-09-16 09:10:26
Document Modified: 2019-09-16 09:10:26

© 2024 FCC.report