RF Exposure Info

FCC ID: 2AMZYAIRCORE

RF Exposure Info

Download: PDF
FCCID_4262877

                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch




                                                                    Report No.: SZEM190101070504
                                                                    Page:        1 of 31


                       Human Exposure Report
Application No.:               SZEM1901010705CR
Applicant:                     HandStandsPromo LLC
Address of Applicant:          1420 S. 4800 W. Suite A, Salt Lake City, Utah, 84104 United States
Manufacturer:                  HandStandsPromo LLC
Address of Manufacturer:       1420 S. 4800 W. Suite A, Salt Lake City, Utah, 84104 United States
Factory:                   Amitec Industrial Limited
Address of Factory:        815, Rongchao Building A, Haixiu Road, Bao'An, Shenzhen City, Guangdong
                           Province, China
Equipment Under Test (EUT):
EUT Name:                  Air Core
Model No.:                     K00110
Trade mark:                    Numi
FCC ID:                        2AMZYAIRCORE
Standards:                     47 CFR PART 1, Subpart I, Section 1.1310
Date of Receipt:               2019-01-25
Date of Test:                  2019-01-28 to 2019-02-22
Date of Issue:                 2019-04-28
Test Result :                    Pass*
* In the configuration tested, the EUT complied with the standards specified above
 This report supersedes our previous report SZEM190101070502, issued on 2019-02-26, which is hereby
 deemed null and void.




            Keny Xu
      EMC Laboratory Manager


                                               SGS-CSTC Standards Technical Services Co., Ltd.
                                               Shenzhen Branch
                                                                                                    Report No.: SZEM190101070504
                                                                                                    Page:       2 of 31




1         Contents
                                                                                                                                                           Page
1      CONTENTS ................................................................................................................................................2

2      GENERAL INFORMATION ........................................................................................................................3
    2.1    DETAILS OF E.U.T. ...................................................................................................................................3
    2.2    DESCRIPTION OF SUPPORT UNITS .............................................................................................................3
    2.3    TEST LOCATION ........................................................................................................................................4
    2.4    TEST FACILITY ..........................................................................................................................................4
    2.5    DEVIATION FROM STANDARDS ...................................................................................................................4
    2.6    ABNORMALITIES FROM STANDARD CONDITIONS..........................................................................................4
3      EQUIPMENTS USED DURING TEST ........................................................................................................5

4      TEST RESULTS .........................................................................................................................................6
    4.1 RF EXPOSURE TEST .................................................................................................................................6
       4.1.1 E.U.T. Operation ............................................................................................................................6
       4.1.2 Measurement Data.........................................................................................................................7
5      PHOTOGRAPHS- RF EXPOSURE SETUP PHOTOS.............................................................................31


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                            Report No.: SZEM190101070504
                                                            Page:       3 of 31




2   General Information
2.1 Details of E.U.T.
    Power supply:          Input: DC 5V/2A DC 9V/1.67A
                           Output:
                           Wireless 5W(DC 5V/1A), 7.5W(DC 5V/1.5A), 10W(DC 9V/1.1A)
    Antenna Type:          Loop Antenna
    Modulation Type:       Load Modulation
    Operation Frequency:   112.50kHz to 183.33kHz
    Remark:                Tests were conducted in all three load modes and the worst case(10W) is
                           reported only.



2.2 Description of Support Units

    Description              Manufacturer               Model No.                 Serial No.
    Adapter                   SAMSUNG                    EP-TA200             R37J8YA7W71DK3
    iPhone 8                    Apple                     A1863                F4GVQ656JC6D
    Mobile Phone              SAMSUNG                    SM-G9500               R28J9140LPB


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                                Report No.: SZEM190101070504
                                                                Page:       4 of 31



2.3 Test Location
     All tests were performed at:
     SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch E&E Lab,
     No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong,China
     518057.
     Tel: +86 755 2601 2053         Fax: +86 755 2671 0594
     No tests were sub-contracted.
2.4 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
    been registered in accordance with the Regulations for Voluntary Control Measures with Registration
    No.: G-20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    as an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    CAB identifier: CN0006.
    IC#: 4620C.
2.5 Deviation from Standards
    None.
2.6 Abnormalities from Standard Conditions
    None.


                        SGS-CSTC Standards Technical Services Co., Ltd.
                        Shenzhen Branch
                                                  Report No.: SZEM190101070504
                                                  Page:       5 of 31




3   Equipments Used during Test

                                                        Inventory
    Item   Test Equipment    Manufacturer   Model No.               Cal. Due date
                                                           No.
            Electric and
     1     Magnetic Field       Narda       EHP-50F     EMC092        2020-02-05
             Analyzer


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                     Report No.: SZEM190101070504
                                                                     Page:       6 of 31




4     Test Results
4.1 RF Exposure test
      Test Requirement:                 47 CFR PART 1, Subpart I, Section 1.1310
      Measurement Distance:             0/2/4/8/10/15cm
      Test voltage:                     DC 5V/9V
      Limit:

    Frequency range Electric field strength Magnetic field strength Power density Averaging time
         (MHz)               (V/m)                  (A/m)             (mW/cm2)      (minutes)
                            (A) Limits for Occupational/Controlled Exposures
         0.3-3.0                 614                        1.63               *(100)             6
          3.0-30                1842/f                      4.89/f            *(900/f2)           6
         30-300                  61.4                       0.163                  1.0            6
        300-1500                    /                         /                f/300              6
      1500-100,000                  /                         /                    5              6
                         (B) Limits for General Population/Uncontrolled Exposure
         0.3-1.34                614                        1.63               *(100)             30
         1.34-30                824/f                       2.19/f            *(180/f2)           30
         30-300                  27.5                       0.073                  0.2            30
        300-1500                    /                         /                f/1500             30
      1500-100,000                  /                         /                    1.0            30
    F=frequency in MHz
    *=Plane-wave equivalent power density
    RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC rules.
    The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits for
    150kHz:614V/m,1.63A/m).
4.1.1 E.U.T. Operation
      Operating Environment:
      Temperature:        25.0 °C           Humidity:     52 % RH        Atmospheric Pressure: 1015 mbar
      EUT Operation:
      This device has been tested the worst status of full load and the device has been tested with load at
       zero charge, intermediate charge, and full charge.


                                                  SGS—CSTC Standards Technical Services Co., Ltd.
                                                  Shenzhen Branch

                                                                                                                      Report No.: SZEM190101070504
                                                                                                                      Page:                    7 of 31



4.1.2 Measurement Data


     All three load modes were conducted and the worst case(10W) is reported only.
     Output Voltage=DC 9V; The max output power =10W;Calculation of resistor value=8.10
     Grip Pad Plus
     Electric Field Emissions

        Operation                      Test Distance                    Test Position                         Probe Measure                          50% Limit
        frequency                               (cm)                                                             Result (V/m)                            (V/m)

                                                                                Side 1                                   5.45                                  307
                                                                                Side 2                                   6.49                                  307
          133.5 kHz                                0                            Side 3                                   7.93                                  307
                                                                                Side 4                                   417                                   307
                                                                                   Top                                   7.82                                  307


     Magnetic Field Emissions

        Operation                      Test Distance                    Test Position                         Probe Measure                          50% Limit
        frequency                           (cm)                                                               Result (A/m)                            (A/m)

                                                                                Side 1                                 0.3068                             0.815
                                                                                Side 2                                 0.4893                             0.815

          133.5 kHz                                0                            Side 3                                 0.2075                             0.815

                                                                                Side 4                                 0.5295                             0.815

                                                                                   Top                                 0.5243                             0.815

     Electric Field Emissions

        Operation                      Test Distance                    Test Position                         Probe Measure                          50% Limit
        frequency                               (em)                                                             Result (V/m)                            (V/m)

                                                                                Side 1                                   4.38                                  307
                                                                                Side 2                                   527                                   307
          133.5 kHz                                2                            Side 3                                   6.33                                  307
                                                                                Side 4                                   3.02                                  307

                                                                                   Top                                   6.64                                  307

                                     Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                     overieat, avellable on request or accessible at hitps!wwsgs.comen/Terms—and—condtonsaspx and.fot electronic format documents,
                                     subject to Terms and Gonditions for Electronic Documents at hiip:/wwnw.sgs.comen/Terms—and—Gonditions/Terms—0—Document aspx.
                                     Attention is draun to the limitation of liabiliy, indemnification and juriediction issues defined therein. Any holder of this document is
                                     advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                                     Client‘s instructions, if any. The Company‘s sole responsiblity is to its Client and this document does not exonerate parties to a
                                     transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                                     except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
       tigtiinl 4/80                 appearance of this documentis unlawul and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the
      pecion Tetng Sevics f          results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 deys only.
                         * $         Aftention: To check the authenticity of testing /inspection report & certificate, please contact us at talephone: (86—755) 8307 1443,
                                     or email: CN.Doecheck@sas.com
                               Ltd   No.1 Worishop,M—10, Midde Secton,Scence & Technoogy Part Shenthen, Cina 518057   t (86—755) 20012058 1 (86—755)26710504    wimsgsgroup.com.en
                                      1B +RHARITEM—10%—31B                                         BBMH: 518057       t (66—755)26012053 f (66—755)26710504      sgo.china@sgs.com
                                                                                                                                        Member of the SGS Group (SGS SA)


                                    SGS—CSTC Standards Technical Services Co., Ltd.
                                    Shenzhen Branch

                                                                                                        Report No.: SZEM190101070504
                                                                                                        Page:                    8 of 31




Magnetic Field Emissions

   Operation              Test Distance                      Test Position                        Probe Measure                          50% Limit
   frequency                   (em)                                                                Result (A/m)                            (A/m)

                                                                     Side 1                                0.2596                                0.815
                                                                     Side 2                                0.4033                                0.815
   188.5 kHz                            2                            Side 3                                01735                                 0.815
                                                                     Side 4                                0.4672                                0.815
                                                                       Top                                 0.4538                                0.815
Electric Field Emissions

   Operation              Test Distance                      Test Position                        Probe Measure                          50% Limit
   frequency                   (em)                                                                Result (V/m)                            (V/m)

                                                                     Side 1                                  3.12                                307
                                                                     Side 2                                  4.05                                307
   1838.5 kHz                           4                            Side 3                                  517                                 307
                                                                     Side 4                                   1.96                               307

                                                                       Top                                   4.35                                307

Magnetic Field Emissions

   Operation              Test Distance                      Test Position                        Probe Measure                          50% Limit
   frequency                   (em)                                                                Result (A/m)                            (A/m)

                                                                     Side 1                                0.2044                                0.815

                                                                     Side 2                                0.3587                                0.815
   188.5 kHz                            4                            Side 3                                01162                                 0.815
                                                                     Side 4                                0.4134                                0.815
                                                                       Top                                 0.3982                                0.815




                   Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                   overleat, available on request or accessible at hitp://wwn‘. sgs.comen/Terms—and—Conditions.aspx and, for electronic format documents,
                   Subject io Terms and Gonditions for Electrontclmim     Documents at hi         sgs. comfenTermsang:GondlionsyTerms—6.booument aspx.
                   Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is
                   advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                   Client‘s instructions, if any. The Company‘s sole responsibility is to its Client and this document does not exonerate parties to a
                   fransaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                   except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
                   appearance of this documentis unlawiul and offenders may be prosecuted to the fullest extent of the law. Unless othenwise stated the
                   results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
                   Attention: To check the authenticity of testing !Inspection report & certificate, please contact us at talephone: (B6—755) 8307 1443,
                   or email: CN.Doecheck@sas.com
          p00.0¢       No.1 Worishop,M—10, Midde Secton,Scence & Technoogy Part Shenthen, Cina 518057   t (86—755) 20012058 1 (86—755)26710504    wimsgsgroup.com.en
                       tE —Ril— HRRHEM—10%—S1B                                       A6H: 518057        t (B6—758)26012053 1 (86—758)26710504     sgschina@sgs.com
                   t
                                                                                                                          Member of the SGS Group (SGS SA)


                                 SGS—CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch

                                                                                                     Report No.: SZEM190101070504
                                                                                                     Page:                    9 of 31




Electric Field Emissions

   Operation           Test Distance                      Test Position                        Probe Measure                          50% Limit
   frequency                (em)                                                                Result (V/m)                            (V/m)

                                                                  Side 1                                   1.03                               307
                                                                  Side 2                                  0.96                                307
   133.5 kHz                         8                            Side 3                                  249                                 307

                                                                  Side 4                                  0.76                                307
                                                                    Top                                    1.78                               307


Magnetic Field Emissions

   Operation           Test Distance                      Test Position                        Probe Measure                          50% Limit
   frequency                (em)                                                                Result (A/m)                            (A/m)

                                                                  Side 1                                0.1112                                0.815

                                                                  Side 2                                01824                                 0.815
   188.5 kHz                         8                            Side 3                                0.0637                                0.815
                                                                  Side 4                                0.2567                                0.815
                                                                    Top                                 0.2143                                0.815

Electric Field Emissions

   Operation           Test Distance                      Test Position                        Probe Measure                          50% Limit
   frequency                (em)                                                                Result (V/m)                            (V/m)

                                                                  Side 1                                  0.87                                307
                                                                  Side 2                                  0.74                                307
   183.5 kHz                        10                            Side 3                                  1.09                                307
                                                                  Side 4                                  0.59                                307
                                                                    Top                                    1.13                               307




                   Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                   overleat, available on request or accessible at hitp://wwn‘. sgs.comen/Terms—and—Conditions.aspx and, for electronic format documents,
                   Subject io Terms and Gonditions for Electrontclmim     Documents at hi         sgs. comfenTermsang:GondlionsyTerms—6.booument aspx.
                   Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is
                   advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                   Client‘s instructions, if any. The Company‘s sole responsibility is to its Client and this document does not exonerate parties to a
                   fransaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                   except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
                   appearance of this documentis unlawiul and offenders may be prosecuted to the fullest extent of the law. Unless othenwise stated the
                   results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
                   Attention: To check the authenticity of testing !Inspection report & certificate, please contact us at talephone: (B6—755) 8307 1443,
                   or email: CN.Doecheck@sas.com
          p00.0¢    No.1 Worishop,M—10, Midde Secton,Scence & Technoogy Part Shenthen, Cina 518057   t (86—755) 20012058 1 (86—755)26710504    wimsgsgroup.com.en
                    TB +RHRRREM—10%—S1B                                           A6H: 518057        t (B6—758)26012053 1 (86—758)26710504     sgschina@sgs.com
                                                                                                                       Member of the SGS Group (SGS SA)


                                           SGS—CSTC Standards Technical Services Co., Ltd.
                                           Shenzhen Branch

                                                                                                               Report No.: SZEM190101070504
                                                                                                               Page:                     10 of 31




Magnetic Field Emissions

    Operation                    Test Distance                      Test Position                        Probe Measure                          50% Limit
    frequency                         (em)                                                                Result (A/m)                            (A/m)

                                                                            Side 1                                0.0539                                0.815
                                                                            Side 2                                0.1043                                0.815

     133.5 kHz                                10                            Side 3                                0.0328                                0.815

                                                                            Side 4                                0.1297                                0.815


                                                                              Top                                 0.c976                                0.815
Electric Field Emissions

    Operation                    Test Distance                      Test Position                        Probe Measure                          50% Limit
    frequency                         (em)                                                                Result (V/m)                            (V/m)

                                                                            Side 1                                  0.38                                307

                                                                            Side 2                                  0.29                                307
     133.5 kHz                                15                            Side 3                                  0.58                                307

                                                                            Side 4                                  0.19                                307
                                                                              Top                                   0.67                                307


Magnetic Field Emissions

    Operation                    Test Distance                      Test Position                        Probe Measure                          50% Limit
    frequency                         (em)                                                                Result (A/m)                            (A/m)

                                                                            Side 1                                0.0081                                0.815
                                                                            Side 2                                0.0096                                0.815

     133.5 kHz                                15                            Side 3                                0.0048                                0.815

                                                                            Side 4                                0.0132                                0.815

                                                                              Top                                 o.o101                                0.815




                          Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                          overleat, available on request or accessible at hitp:/wwn. sqs.comen/Terms—and—Conditions.aspx and, for electronic format documents,
                          Subject io Terms and Gonditions for Electrontc Documents at hilmim sgs. comfenTermsang:GondlionsyTerms—6.booument aspx.
                          Attention is draun to the limitation of liabiliy, indemnification and juriediction issues defined therein. Any holder of this document is
                          advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                          Client‘s instructions, if any. The Company‘s sole responsiblity is to its Client and this document does not exonerate parties to a
                          transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                          except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
 Biptonl 4 8              appearance of this documentis unlawul and offenders may be prosecuted to the fullest extent of the law. Unless othenwise stated the
pecion Testng Sevies      results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 deys only.
                          Aftention: To check the authenticity of testing /inspection report & certificate, please contact us at talephone: (86—755) 8307 1443,
                          or email: CN.Doecheck@sas.com
                 p00.0¢       No.1 Worishop,M—10, Midde Secton,Scence & Technoogy Part Shenthen, Cina 518057   t (86—755) 20012058 1 (86—755)26710504    wimsgsgroup.com.en
                Euclul        1B +RHARITEM—10%—31B                                          BBMH: 518057       t (66—755)26012053 f (66—755)26710504     sgo.china@sgs.com
                          t
                                                                                                                                 Member of the SGS Group (SGS SA)


                        SGS-CSTC Standards Technical Services Co., Ltd.
                        Shenzhen Branch
                                                       Report No.: SZEM190101070504
                                                       Page:       11 of 31



Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      7.11         6.87         5.67        307
                               Side 2      7.97         7.38         6.55        307
  133.5 kHz         0          Side 3      9.84         8.98         8.14        307
                               Side 4      6.57         5.73         4.35        307
                                Top        9.53         8.44         7.92        307


Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.5548       0.4734       0.3958       0.815

                               Side 2     0.5796       0.5356       0.4874       0.815
  133.5 kHz         0          Side 3     0.5937       0.5644       0.5187       0.815
                               Side 4     0.3367       0.2729       0.2243       0.815
                                Top       0.5738       0.5387       0.5094       0.815


Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      6.54         5.42         4.38        307

                               Side 2      7.02         6.21         5.39        307
  133.5 kHz         2          Side 3      8.56         7.44         6.73        307
                               Side 4      5.89         5.04         3.97        307
                                Top        8.69         7.64         7.02        307


                        SGS-CSTC Standards Technical Services Co., Ltd.
                        Shenzhen Branch
                                                       Report No.: SZEM190101070504
                                                       Page:       12 of 31




Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.4337       0.4018       0.3672       0.815

                               Side 2     0.4825       0.4474       0.3979       0.815
  133.5 kHz         2          Side 3     0.4479       0.3728       0.3256       0.815
                               Side 4     0.2753       0.2419       0.2015       0.815
                                Top       0.4521       0.3953       0.3467       0.815


Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      5.57         4.75         3.48        307

                               Side 2      6.28         5.39         4.29        307
  133.5 kHz         4          Side 3      7.19         6.38         5.43        307
                               Side 4      4.44         3.96         3.11        307
                                Top        7.39         6.55         5.34        307


Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.3543       0.3528       0.3142       0.815

                               Side 2     0.4129       0.3911       0.3345       0.815
  133.5 kHz         4          Side 3     0.4083       0.3223       0.2798       0.815
                               Side 4     0.2218       0.1736       0.1324       0.815
                                Top       0.3927       0.3452       0.3012       0.815


                         SGS-CSTC Standards Technical Services Co., Ltd.
                         Shenzhen Branch
                                                       Report No.: SZEM190101070504
                                                       Page:       13 of 31




Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      2.47         1.82         1.22        307

                               Side 2      3.32         2.59         1.87        307
  133.5 kHz         8          Side 3      4.56         3.57         2.87        307
                               Side 4      1.57         1.03         0.86        307
                                Top        4.29         3.45         2.37        307

Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.2109       0.1337       0.1156       0.815

                               Side 2     0.1842       0.1429       0.1239       0.815
  133.5 kHz         8          Side 3     0.1578       0.1382       0.1081       0.815
                               Side 4     0.0984       0.0852       0.0741       0.815
                                Top       0.1447       0.1197       0.0978       0.815

Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      1.86         1.23         0.95        307

                               Side 2      2.21         1.46         1.10        307
  133.5 kHz         10         Side 3      2.98         1.88         1.47        307
                               Side 4      1.02         0.78         0.64        307
                                Top        3.41         1.76         1.17        307


                         SGS-CSTC Standards Technical Services Co., Ltd.
                         Shenzhen Branch
                                                       Report No.: SZEM190101070504
                                                       Page:       14 of 31




Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.1573       0.0875       0.0638       0.815
                               Side 2     0.1329       0.0921       0.0727       0.815
  133.5 kHz         10         Side 3     0.0796       0.0794       0.0481       0.815
                               Side 4     0.0438       0.0463       0.0395       0.815
                                Top       0.0882       0.0753       0.0469       0.815


Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      0.79         0.44         0.38        307
                               Side 2      1.02         0.66         0.41        307
  133.5 kHz         15         Side 3      1.17         0.75         0.38        307
                               Side 4      0.57         0.43         0.29        307
                                Top        1.45         0.82         0.65        307


Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.0723       0.0515       0.0272       0.815
                               Side 2     0.0582       0.0438       0.0195       0.815
  133.5 kHz         15         Side 3     0.0344       0.0238       0.0162       0.815
                               Side 4     0.0126       0.0098       0.0067       0.815
                                Top       0.0299       0.0119       0.0093       0.815


                      SGS-CSTC Standards Technical Services Co., Ltd.
                      Shenzhen Branch
                                                    Report No.: SZEM190101070504
                                                    Page:       15 of 31


Smart Dock Plus
Placed Flat
Electric Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (V/m)
                      (cm)                                          (V/m)
                                     Side 1           6.27          307
                                     Side 2           6.85          307
   133.5 kHz               0         Side 3           5.38          307
                                     Side 4           4.89          307
                                      Top             4.93          307


Magnetic Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (A/m)
                      (cm)                                          (A/m)
                                     Side 1          0.3246         0.815
                                     Side 2          0.3589         0.815
   133.5 kHz               0         Side 3          0.5448         0.815
                                     Side 4          0.5792         0.815
                                      Top            0.4532         0.815


Electric Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (V/m)
                      (cm)                                          (V/m)
                                     Side 1           5.23          307
                                     Side 2           5.54          307
   133.5 kHz               2         Side 3           4.27          307
                                     Side 4           3.69          307
                                      Top             3.81          307


                      SGS-CSTC Standards Technical Services Co., Ltd.
                      Shenzhen Branch
                                                    Report No.: SZEM190101070504
                                                    Page:       16 of 31




Magnetic Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (A/m)
                      (cm)                                          (A/m)
                                     Side 1          0.2673         0.815
                                     Side 2          0.2981         0.815
   133.5 kHz               2         Side 3          0.4119         0.815
                                     Side 4          0.4278         0.815
                                      Top            0.3429         0.815


Electric Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (V/m)
                      (cm)                                          (V/m)
                                     Side 1           4.09          307
                                     Side 2           4.22          307
   133.5 kHz               4         Side 3           2.98          307
                                     Side 4           2.51          307
                                      Top             2.77          307


Magnetic Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (A/m)
                      (cm)                                          (A/m)
                                     Side 1          0.2123         0.815
                                     Side 2          0.2257         0.815
   133.5 kHz               4         Side 3          0.3071         0.815
                                     Side 4          0.3319         0.815
                                      Top            0.2387         0.815


                      SGS-CSTC Standards Technical Services Co., Ltd.
                      Shenzhen Branch
                                                    Report No.: SZEM190101070504
                                                    Page:       17 of 31




Electric Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (V/m)
                      (cm)                                          (V/m)
                                     Side 1           1.87          307
                                     Side 2           2.03          307
   133.5 kHz               8         Side 3           0.99          307
                                     Side 4           0.75          307
                                      Top             0.77          307


Magnetic Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (A/m)
                      (cm)                                          (A/m)
                                     Side 1          0.1039         0.815
                                     Side 2          0.1145         0.815
   133.5 kHz               8         Side 3          0.1329         0.815
                                     Side 4          0.1453         0.815
                                      Top            0.0982         0.815


Electric Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (V/m)
                      (cm)                                          (V/m)
                                     Side 1           1.32          307
                                     Side 2           1.43          307
   133.5 kHz           10            Side 3           0.84          307
                                     Side 4           0.59          307
                                      Top             0.62          307


                      SGS-CSTC Standards Technical Services Co., Ltd.
                      Shenzhen Branch
                                                    Report No.: SZEM190101070504
                                                    Page:       18 of 31




Magnetic Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (A/m)
                      (cm)                                          (A/m)
                                     Side 1          0.0579         0.815
                                     Side 2          0.0621         0.815
   133.5 kHz           10            Side 3          0.0597         0.815
                                     Side 4          0.0723         0.815
                                      Top            0.0467         0.815


Electric Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (V/m)
                      (cm)                                          (V/m)
                                     Side 1           0.74          307
                                     Side 2           0.81          307
   133.5 kHz           15            Side 3           0.39          307
                                     Side 4           0.24          307
                                      Top             0.27          307


Magnetic Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (A/m)
                      (cm)                                          (A/m)
                                     Side 1          0.0089         0.815
                                     Side 2          0.0098         0.815
   133.5 kHz           15            Side 3          0.0077         0.815
                                     Side 4          0.0124         0.815
                                      Top            0.0064         0.815


                        SGS-CSTC Standards Technical Services Co., Ltd.
                        Shenzhen Branch
                                                       Report No.: SZEM190101070504
                                                       Page:       19 of 31



Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      7.29         6.92         6.39        307
                               Side 2      7.93         7.51         7.04        307
  133.5 kHz         0          Side 3      6.10         5.81         5.43        307
                               Side 4      5.58         5.25         4.81        307
                                Top        5.74         5.47         4.99        307


Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.4718       0.4139       0.3275       0.815
                               Side 2     0.5133       0.4736       0.3684       0.815
  133.5 kHz         0          Side 3     0.5479       0.5384       0.5247       0.815
                               Side 4     0.6123       0.5942       0.5431       0.815
                                Top       0.5257       0.4829       0.4532       0.815


Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      6.34         5.94         5.37        307
                               Side 2      6.75         6.23         5.98        307
  133.5 kHz         2          Side 3      5.33         4.72         4.43        307
                               Side 4      4.66         4.18         3.87        307
                                Top        4.81         4.29         3.79        307


                        SGS-CSTC Standards Technical Services Co., Ltd.
                        Shenzhen Branch
                                                       Report No.: SZEM190101070504
                                                       Page:       20 of 31




Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.3936       0.3452       0.3119       0.815
                               Side 2     0.4387       0.3871       0.3521       0.815
  133.5 kHz         2          Side 3     0.4512       0.3927       0.3648       0.815
                               Side 4     0.5129       0.4183       0.3819       0.815
                                Top       0.4337       0.3634       0.3204       0.815


Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      5.31         5.03         4.73        307
                               Side 2      5.58         5.18         4.92        307
  133.5 kHz         4          Side 3      4.49         4.32         3.99        307
                               Side 4      3.81         3.45         2.89        307
                                Top        3.77         3.29         2.73        307


Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.3346       0.3139       0.2917       0.815
                               Side 2     0.3678       0.3342       0.3084       0.815
  133.5 kHz         4          Side 3     0.4017       0.3727       0.3429       0.815
                               Side 4     0.4423       0.3878       0.3518       0.815
                                Top       0.3583       0.3204       0.3005       0.815


                         SGS-CSTC Standards Technical Services Co., Ltd.
                         Shenzhen Branch
                                                       Report No.: SZEM190101070504
                                                       Page:       21 of 31




Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      3.29         2.97         2.63        307
                               Side 2      3.66         3.21         2.94        307
  133.5 kHz         8          Side 3      2.62         2.09         1.78        307
                               Side 4      1.93         1.56         1.27        307
                                Top        1.88         1.41         1.09        307

Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.1193       0.0984       0.0756       0.815
                               Side 2     0.1438       0.1127       0.0908       0.815
  133.5 kHz         8          Side 3     0.1956       0.1398       0.1013       0.815
                               Side 4     0.2042       0.1538       0.1234       0.815
                                Top       0.1381       0.1012       0.8329       0.815

Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      2.74         2.31         2.12        307
                               Side 2      2.96         2.48         2.28        307
  133.5 kHz         10         Side 3      2.04         1.67         1.33        307
                               Side 4      1.29         0.97         0.84        307
                                Top        1.31         0.89         0.65        307


                         SGS-CSTC Standards Technical Services Co., Ltd.
                         Shenzhen Branch
                                                       Report No.: SZEM190101070504
                                                       Page:       22 of 31




Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.0687       0.0438       0.0382       0.815
                               Side 2     0.0895       0.0626       0.0513       0.815
  133.5 kHz         10         Side 3     0.1102       0.0849       0.0646       0.815
                               Side 4     0.1338       0.0929       0.0738       0.815
                                Top       0.0856       0.0527       0.0449       0.815


Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      1.11         0.92         0.74        307
                               Side 2      1.38         1.01         0.81        307
  133.5 kHz         15         Side 3      0.96         0.75         0.52        307
                               Side 4      0.45         0.38         0.23        307
                                Top        0.37         0.23         0.14        307


Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.0073       0.0058       0.0043       0.815
                               Side 2     0.0082       0.0074       0.0055       0.815
  133.5 kHz         15         Side 3     0.0096       0.0083       0.0063       0.815
                               Side 4     0.0127       0.0102       0.0081       0.815
                                Top       0.0077       0.0061       0.0049       0.815


                      SGS-CSTC Standards Technical Services Co., Ltd.
                      Shenzhen Branch
                                                    Report No.: SZEM190101070504
                                                    Page:       23 of 31




Smart Dock Plus
Placed in Landscape Viewing Angle
Electric Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (V/m)
                      (cm)                                          (V/m)
                                     Side 1           8.36          307

                                     Side 2           8.27          307
    133.5 kHz              0         Side 3           7.69          307
                                     Side 4           6.54          307
                                      Top             6.68          307


Magnetic Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (A/m)
                      (cm)                                          (A/m)
                                     Side 1          0.4834         0.815
                                     Side 2          0.4759         0.815
    133.5 kHz              0         Side 3          0.5644         0.815
                                     Side 4          0.5388         0.815
                                      Top            0.4912         0.815


Electric Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (V/m)
                      (cm)                                          (V/m)
                                     Side 1           7.23          307

                                     Side 2           7.04          307
    133.5 kHz              2         Side 3           6.51          307
                                     Side 4           5.44          307
                                      Top             5.50          307


                      SGS-CSTC Standards Technical Services Co., Ltd.
                      Shenzhen Branch
                                                    Report No.: SZEM190101070504
                                                    Page:       24 of 31




Magnetic Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (A/m)
                      (cm)                                          (A/m)
                                     Side 1          0.4213         0.815
                                     Side 2          0.4051         0.815
   133.5 kHz               2         Side 3          0.4859         0.815
                                     Side 4          0.4587         0.815
                                      Top            0.4002         0.815


Electric Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (V/m)
                      (cm)                                          (V/m)
                                     Side 1           6.08          307

                                     Side 2           5.84          307
   133.5 kHz               4         Side 3           5.38          307
                                     Side 4           4.21          307
                                      Top             4.39          307


Magnetic Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (A/m)
                      (cm)                                          (A/m)
                                     Side 1          0.3329         0.815
                                     Side 2          0.3467         0.815
   133.5 kHz               4         Side 3          0.3673         0.815
                                     Side 4          0.3824         0.815
                                      Top            0.3119         0.815


                      SGS-CSTC Standards Technical Services Co., Ltd.
                      Shenzhen Branch
                                                    Report No.: SZEM190101070504
                                                    Page:       25 of 31




Electric Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (V/m)
                      (cm)                                          (V/m)
                                     Side 1           3.95          307

                                     Side 2           3.73          307
   133.5 kHz               8         Side 3           3.02          307
                                     Side 4           2.38          307
                                      Top             2.44          307


Magnetic Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (A/m)
                      (cm)                                          (A/m)
                                     Side 1          0.2136         0.815
                                     Side 2          0.2281         0.815
   133.5 kHz               8         Side 3          0.2312         0.815
                                     Side 4          0.2468         0.815
                                      Top            0.2119         0.815


Electric Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (V/m)
                      (cm)                                          (V/m)
                                     Side 1           2.96          307

                                     Side 2           2.81          307
   133.5 kHz           10            Side 3           1.87          307
                                     Side 4           1.22          307
                                      Top             1.35          307


                      SGS-CSTC Standards Technical Services Co., Ltd.
                      Shenzhen Branch
                                                    Report No.: SZEM190101070504
                                                    Page:       26 of 31




Magnetic Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (A/m)
                      (cm)                                          (A/m)
                                     Side 1          0.1003         0.815
                                     Side 2          0.1134         0.815
   133.5 kHz           10            Side 3          0.1189         0.815
                                     Side 4          0.1278         0.815
                                      Top            0.1189         0.815


Electric Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (V/m)
                      (cm)                                          (V/m)
                                     Side 1           1.29          307

                                     Side 2           1.06          307
   133.5 kHz           15            Side 3           0.98          307
                                     Side 4           0.67          307
                                      Top             0.75          307


Magnetic Field Emissions
   Operation      Test Distance   Test Position   Probe Measure   50% Limit
   frequency                                       Result (A/m)
                      (cm)                                          (A/m)
                                     Side 1          0.0113         0.815
                                     Side 2          0.0169         0.815
   133.5 kHz           15            Side 3          0.0188         0.815
                                     Side 4          0.0238         0.815
                                      Top            0.0107         0.815


                        SGS-CSTC Standards Technical Services Co., Ltd.
                        Shenzhen Branch
                                                       Report No.: SZEM190101070504
                                                       Page:       27 of 31



Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      9.81         9.04         8.39        307
                               Side 2      9.76         9.11         8.62        307
  133.5 kHz         0          Side 3      8.82         8.34         7.88        307
                               Side 4      7.39         7.01         6.48        307
                                Top        7.22         6.84         6.57        307


Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.5824       0.5683       0.5472       0.815
                               Side 2     0.5792       0.5571       0.5326       0.815
  133.5 kHz         0          Side 3     0.5884       0.5612       0.5393       0.815
                               Side 4     0.5631       0.5214       0.4948       0.815
                                Top       0.5477       0.5139       0.4714       0.815


Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      8.75         8.34         7.56        307
                               Side 2      8.62         8.12         7.45        307
  133.5 kHz         2          Side 3      7.44         7.03         6.59        307
                               Side 4      6.28         5.74         5.27        307
                                Top        6.09         5.61         5.12        307


                        SGS-CSTC Standards Technical Services Co., Ltd.
                        Shenzhen Branch
                                                       Report No.: SZEM190101070504
                                                       Page:       28 of 31




Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.5219       0.4832       0.4406       0.815
                               Side 2     0.5118       0.4779       0.4351       0.815
  133.5 kHz         2          Side 3     0.5242       0.4821       0.4433       0.815
                               Side 4     0.5109       0.4725       0.4318       0.815
                                Top       0.5003       0.4619       0.4127       0.815


Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      7.42         6.98         6.45        307
                               Side 2      7.33         6.87         6.38        307
  133.5 kHz         4          Side 3      6.15         5.46         5.01        307
                               Side 4      5.02         4.34         3.87        307
                                Top        4.89         4.22         3.76        307


Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.4519       0.4132       0.3824       0.815
                               Side 2     0.4632       0.4235       0.3719       0.815
  133.5 kHz         4          Side 3     0.4782       0.4321       0.3892       0.815
                               Side 4     0.4613       0.4122       0.3657       0.815
                                Top       0.4428       0.4003       0.3552       0.815


                         SGS-CSTC Standards Technical Services Co., Ltd.
                         Shenzhen Branch
                                                       Report No.: SZEM190101070504
                                                       Page:       29 of 31




Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      5.21         4.78         4.29        307
                               Side 2      5.06         4.56         4.02        307
  133.5 kHz         8          Side 3      4.23         3.81         3.27        307
                               Side 4      3.31         2.67         2.11        307
                                Top        2.95         2.23         1.84        307

Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.3327       0.2735       0.2346       0.815
                               Side 2     0.3189       0.2543       0.2217       0.815
  133.5 kHz         8          Side 3     0.3392       0.2721       0.2408       0.815
                               Side 4     0.3101       0.2613       0.2385       0.815
                                Top       0.3006       0.2528       0.2214       0.815

Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      3.45         2.76         2.33        307
                               Side 2      2.88         2.13         1.68        307
  133.5 kHz         10         Side 3      2.13         1.65         1.32        307
                               Side 4      1.97         1.28         0.95        307
                                Top        1.25         0.87         0.63        307


                         SGS-CSTC Standards Technical Services Co., Ltd.
                         Shenzhen Branch
                                                       Report No.: SZEM190101070504
                                                       Page:       30 of 31




Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.2538       0.2213       0.1763       0.815
                               Side 2     0.2618       0.2347       0.1472       0.815
  133.5 kHz         10         Side 3     0.2634       0.2308       0.1395       0.815
                               Side 4     0.2345       0.1949       0.1212       0.815
                                Top       0.2287       0.1887       0.1143       0.815


Mobile phone has been charge at zero charge, intermediate charge, and full charge.
Electric Field Emissions
 Operation        Test         Test         Probe Measure Result(V/m)          50%Limit
 frequency      Distance      Position
                                          zero      intermediate      full      (V/m)
                   (cm)                  charge        charge       charge
                               Side 1      1.48         1.13         0.85        307
                               Side 2      1.16         0.84         0.52        307
  133.5 kHz         15         Side 3      0.75         0.51         0.38        307
                               Side 4      0.58         0.42         0.29        307
                                Top        0.41         0.29         0.18        307


Magnetic Field Emissions
 Operation        Test         Test         Probe Measure Result(A/m)          50%Limit
 frequency      Distance      Position
                                         zero       intermediate   full         (A/m)
                   (cm)                  charge        charge      charge
                               Side 1     0.0482       0.0328       0.0194       0.815
                               Side 2     0.0457       0.0379       0.0183       0.815
  133.5 kHz         15         Side 3     0.0689       0.0413       0.0204       0.815
                               Side 4     0.0421       0.0278       0.0095       0.815
                                Top       0.0335       0.0222       0.0088       0.815


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                               Report No.: SZEM190101070504
                                                               Page:       31 of 31




5   Photographs- RF exposure Setup photos
    Refer to RF setup photos.


                                       - End of the Report -



Document Created: 2019-04-28 06:50:20
Document Modified: 2019-04-28 06:50:20

© 2024 FCC.report