RF Exposure

FCC ID: 2AMZY-R1072

RF Exposure Info

Download: PDF
FCCID_4330735

                          RF EXPOSURE EVALUATION

1. PRODUCT INFORMATION
   Product Description      MyVibe


      Model Name            R1072


         FCC ID             2AMZY-R1072


2. EVALUATION METHOD
According to 447498 D01 General RF Exposure Guidance v05
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation
distances ≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR.
Where f(GHz) is the RF channel transmit frequency in GHz
Power and distance are rounded to the nearest mW and mm before calculation

3. CALCULATION

Pt=-6.550dBm=0.22mW

The value of the Maximum output power Pt is referred to the test report of the CFR47
§15.247.

The result for RF exposure evaluation SAR= (0.22mW /5mm). [√2.402 (GHz)]= 0.07<3.0
for 1-g SAR and ≤ 7.5 for 10-g extremity SAR.


4. CONCLUSION
The SAR evaluation is not required.



Document Created: 2019-05-28 17:00:32
Document Modified: 2019-05-28 17:00:32

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC