Test report_DXX

FCC ID: 2AMY9PLUGHUB

Test Report

Download: PDF
FCCID_4457752

                                                                                               REPORT No.:SZ19050444W02




                                          TEST REPORT

                              APPLICANT                                  : Golden Mark (HK) Limited

                              PRODUCT NAME                               : Plug Hub

                              MODEL NAME                                 : PlugHub Energy, PlugHub

                              BRAND NAME                                 : N/A

                              FCC ID                                     : 2AMY9PLUGHUB

                              STANDARD(S)                                : 47 CFR Part 15 Subpart C

                              RECEIPT DATE                               : 2019-07-05

                              TEST DATE                                  : 2019-07-19 to 2019-08-23

                              ISSUE DATE                                 : 2019-08-23




                                                                        Edited by:
                                                                                               Zeng Xiaoying (Rapporteur)


                                                                        Approved by:
                                                                                               Peng Huarui ( Supervisor )



NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.

                         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
 MORLAB
                                                                                               Tel: 86-755-36698555   Fax: 86-755-36698525
                         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                             Page 1 of 26


                                                                                       REPORT No.:SZ19050444W02


                                                     DIRECTORY
1. Technical Information ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 4
1.1. Applicant and Manufacturer Information ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 4
1.2. Equipment Under Test (EUT) Description ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 4
1.3. Test Standards and Results ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 5
1.4. Environmental Conditions ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 5
2. 47 CFR Part 15C Requirements ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 6
2.1. Antenna requirement ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 6
2.2. Bandwidth ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 7
2.3. Conducted Emission ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 9
2.4. Field strength of fundamentalꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 15
2.5. Radiated Emission and field strength of harmonics ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 17
Annex A Test Uncertainty ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 23
Annex B Testing Laboratory Information ꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏꞏ 24




                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                       Tel: 86-755-36698555   Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page 2 of 26


                                                                                 REPORT No.:SZ19050444W02

                                                     Change History
   Version                                Date                                     Reason for change
     1.0                            2019-08-23                                             First edition




           SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                 Tel: 86-755-36698555   Fax: 86-755-36698525
           FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
           Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                               Page 3 of 26


                                                                                      REPORT No.:SZ19050444W02

1. Technical Information
Note: Provide by applicant.


1.1. Applicant and Manufacturer Information

 Applicant:                              Golden Mark (HK) Limited
 Applicant Address:                      6/F, Kimberley Plaza, 45-47 Kimberley Road, Tsim Sha Tsui,
                                         Kowloon, Hong Kong
 Manufacturer:                           Golden Mark (HK) Limited
 Manufacturer Address:                   6/F, Kimberley Plaza, 45-47 Kimberley Road, Tsim Sha Tsui,
                                         Kowloon, Hong Kong


1.2. Equipment Under Test (EUT) Description

 Product Name:                                  Plug Hub
 Serial No:                                     (N/A, marked #1 by test site)
 Hardware Version:                              1.0
 Software Version:                              1.0
 Equipment type:                                Z-Wave
 Modulation Type                                FSK
 Operating Frequency:                           908.4MHz, 916.0MHz
 Antenna Type:                                  Wire Antenna
 Antenna Gain:                                  2.0 dBi
Note 1: According to the certificate holder, they declared that the models PlugHub Energy and
PlugHub are the very similar products. These two models only differ in Energy Monitor portion in
schematic. PlugHub model removes Energy Monitor IC from hardware. All RF parameters remain
the same as before. The main measuring model is PlugHub Energy, only the results for PlugHub
Energy were recorded in this report.
Note 2: For a more detailed description, please refer to Specification or User’s Manual supplied by
the applicant and/or manufacturer.




                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                      Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 4 of 26


                                                                                            REPORT No.:SZ19050444W02

1.3. Test Standards and Results

The objective of the report is to perform testing according to 47 CFR Part 15 Subpart C for the EUT
FCC ID Certification:
 No    Identity                                                         Document Title

 1     47 CFR Part 15 (10-1-15 Edition)                                 Radio Frequency Devices

Test detailed items/section required by FCC rules and results are as below:
 No.    Section         Description                                                     Test Date           Test Engineer               Result
  1    15.203           Antenna Requirement                                               N/A                       N/A                    PASS
  2    15.215           Bandwidth                                                   Jul 20, 2019             Zhou Chuang                   PASS
                                                                                   Jul 29, 2019
  3    15.207           Conducted Emission                                                                     Lin Jiayong                 PASS
                                                                                   Aug 23, 2019
  4    15.249           Field strength                                              Jul 20, 2019             Peng Xuewei                   PASS
       15.209,          Radiated Emission and field
  5                                                                                 Jul 19, 2019             Peng Xuewei                   PASS
       15.249           strength of harmonics
 Note 1: The tests were performed according to the method of measurements prescribed in
 ANSIC63.10-2013.



1.4. Environmental Conditions

During the measurement, the environmental conditions were within the listed ranges:

 Temperature (°C):                                              15 - 35
 Relative Humidity (%):                                         30 -60
 Atmospheric Pressure (kPa):                                    86-106




                  SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                             Tel: 86-755-36698555   Fax: 86-755-36698525
                  FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                  Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China        Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                           Page 5 of 26


                                                                                     REPORT No.:SZ19050444W02

2. 47 CFR Part 15C Requirements
2.1. Antenna requirement

2.1.1. Applicable Standard

According to FCC 15.203, an intentional radiator shall be designed to ensure that no antenna other
than that furnished by the responsible party shall be used with the device. The use of a
permanently attached antenna or of an antenna that uses a unique coupling to the intentional
radiator shall be considered sufficient to comply with the provisions of this section.


2.1.2. Result: Compliant

The EUT has a permanently and irreplaceable attached antenna. Please refer to the EUT internal
photos.




               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                     Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 6 of 26


                                                                                           REPORT No.:SZ19050444W02

2.2. Bandwidth

2.2.1. Requirement

Refer to FCC 15.215


2.2.2. Test Description

A. Test Set:




The EUT is coupled to the Spectrum Analyzer; the RF load attached to the EUT antenna terminal
is 50Ohm; the path loss as the factor is calibrated to correct the reading.

Make the measurement with the spectrum analyzer's resolution bandwidth (RBW) shall be in the
range of 1% to 3% of the 20dB Bandwidth. In order to make an accurate measurement, set the
span greater than RBW.


2.2.3. Test Result

A.    Test Verdict:

     Channel   Frequency (MHz)                                        20 dB Bandwidth (kHz)                                            Result

       1                908.4                                                          88.02                                            PASS
       2                916.0                                                          126.4                                            PASS




                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                               Tel: 86-755-36698555   Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China           Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                             Page 7 of 26


                                                                                       REPORT No.:SZ19050444W02

B. Test Plots:




                                                     (Channel 1, 908.4MHz)




                                                     (Channel 2, 916.0 MHz)



                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                       Tel: 86-755-36698555   Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page 8 of 26


                                                                                      REPORT No.:SZ19050444W02

2.3. Conducted Emission

2.3.1. Requirement

According to FCC section 15.207, for an intentional radiator that is designed to be connected to the
public utility (AC) power line, the radio frequency voltage that is conducted back onto the AC power
line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following
table, as measured using a 50µH/50Ω line impedance stabilization network (LISN).
 Frequency          range Conducted Limit (dBµV)
 (MHz)                            Quai-peak                                             Average
 0.15 - 0.50                      66 to 56                                              56 to 46
 0.50 - 5                         56                                                    46
 5 - 30                           60                                                    50
NOTE:
(a) The lower limit shall apply at the band edges.
(b) The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.


2.3.2. Test Description

A. Test Setup:




The Table-top EUT was placed upon a non-metallic table 0.8m above the horizontal metal
reference ground plane. EUT was connected to LISN and LISN was connected to reference
Ground Plane. EUT was 80cm from LISN. The set-up and test methods were according to ANSI
C63.10: 2013.



                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                      Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 9 of 26


                                                                                    REPORT No.:SZ19050444W02

2.3.3. Test Result

The maximum conducted interference is searched using Peak (PK), if the emission levels more
than the AV and QP limits, and that have narrow margins from the AV and QP limits will be
re-measured with AV and QP detectors. Tests for both L phase and N phase lines of the power
mains connected to the EUT are performed. Refer to recorded points and plots below.
Note: Both of the test voltage AC 120V/60Hz and AC 230V/50Hz were considered and tested
respectively, only the results of the worst case AC 120V/60Hz were recorded in this report.
A. Test setup:
Test Mode: EUT + TX
Test Voltage: AC 120V/60Hz
The measurement results are obtained as below:
E [dBμV] =UR + LCable loss [dB] + AFactor
UR: Receiver Reading
AFactor: Voltage division factor of LISN




              SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                    Tel: 86-755-36698555   Fax: 86-755-36698525
              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page 10 of 26


                                                                                        REPORT No.:SZ19050444W02

B. Test Plots:
908.4MHz




                                                                 (L Phase)

         Fre.          Emission Level (dBµV)                                     Limit (dBµV)
 NO.                                                                                                           Power-line              Verdict
        (MHz)         Quai-peak                Average                Quai-peak           Average
  1    0.1545             39.32                  32.57                     65.75            55.75                                      PASS
  2    0.2356             34.51                  29.56                     62.25            52.25                                      PASS
  3    0.5732             32.47                  27.30                     56.00            46.00                                      PASS
                                                                                                                   Line
  4    0.9921             31.52                  26.21                     56.00            46.00                                      PASS
  5    1.3549             30.73                  25.45                     56.00            46.00                                      PASS
  6    3.6148             30.84                  21.02                     56.00            46.00                                      PASS




                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                        Tel: 86-755-36698555    Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China    Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                       Page 11 of 26


                                                                                       REPORT No.:SZ19050444W02




                                                                (N Phase)

        Fre.           Emission Level (dBµV)                                     Limit (dBµV)
 NO.                                                                                                           Power-line           Verdict
       (MHz)         Quai-peak                Average                 Quai-peak           Average
  1    0.1503            38.49                   31.75                    65.99             55.99                                      PASS
  2    0.2309            33.77                   28.86                    62.42             52.42                                      PASS
  3    0.3567            31.79                   26.79                    58.81             48.81                                      PASS
                                                                                                                Neutral
  4    0.4877            32.72                   28.36                    56.21             46.21                                      PASS
  5    0.9681            30.67                   25.47                    56.00             46.00                                      PASS
  6    1.4090            29.27                   23.91                    56.00             46.00                                      PASS




                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                        Tel: 86-755-36698555    Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China     Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                       Page 12 of 26


                                                                                         REPORT No.:SZ19050444W02

916MHz




                                                                  (L Phase)

          Fre.          Emission Level (dBµV)                                     Limit (dBµV)
 NO.                                                                                                            Power-line              Verdict
         (MHz)         Quai-peak                Average                Quai-peak           Average
  1      0.1634            47.70                  33.76                     65.29            55.29                                      PASS
  2      0.1905            44.56                  32.14                     64.02            54.02                                      PASS
  3      0.2218            42.72                  31.87                     62.75            52.75                                      PASS
                                                                                                                    Line
  4      0.6267            31.71                  22.70                     56.00            46.00                                      PASS
  5      1.3233            32.00                  22.64                     56.00            46.00                                      PASS
  6      1.8627            45.22                  35.86                     56.00            46.00                                      PASS




                  SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                         Tel: 86-755-36698555    Fax: 86-755-36698525
                  FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                  Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China    Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                        Page 13 of 26


                                                                                       REPORT No.:SZ19050444W02




                                                                (N Phase)

        Fre.           Emission Level (dBµV)                                     Limit (dBµV)
 NO.                                                                                                           Power-line           Verdict
       (MHz)         Quai-peak                Average                 Quai-peak           Average
  1    0.1546            46.12                   31.72                    65.75             55.75                                      PASS
  2    0.1678            49.16                   34.72                    65.07             55.07                                      PASS
  3    0.1995            44.57                   32.78                    63.63             53.63                                      PASS
                                                                                                                Neutral
  4    0.2266            41.95                   31.44                    62.57             52.57                                      PASS
  5    0.3302            35.28                   28.55                    59.45             49.45                                      PASS
  6    1.8276            48.12                   38.91                    56.00             46.00                                      PASS




                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                        Tel: 86-755-36698555    Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China     Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                       Page 14 of 26


                                                                                     REPORT No.:SZ19050444W02

2.4. Field strength of fundamental

2.4.1. Requirement

According to FCC section 15.249(a), except as provided in paragraph (b) of this section, the field
strength of emissions from intentional radiators operated within these frequency bands shall
comply with the following:

   Fundamental               Field strength of fundamental                               Field strength of harmonics
    frequency                       (millivolts/meter)                                        (microvolts/meter)

   902-928 MHz                                        50                                                    500

 2400-2483.5 MHz                                      50                                                    500

  5725-5875 MHz                                       50                                                    500

  24.0-24.25 GHz                                     250                                                    2500


2.4.2. Test Description

A. Test Setup:




The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of
the site as factors are calculated to correct the reading.
For the Test Antenna:
Test Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the
ground to determine the maximum value of the field strength.

               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                     Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 15 of 26


                                                                                       REPORT No.:SZ19050444W02

2.4.3. Test Procedure

Use the following spectrum analyzer settings:
Span = wide enough to fully capture the emission being measured
RBW = 120 kHz
VBW ≥ RBW
Sweep = auto
Detector function = peak
Trace = max hold


2.4.4. Test Result

The measurement results are obtained as below:
E [dBμV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB]
AT: Total correction Factor except Antenna
UR: Receiver Reading
Gpreamp: Preamplifier Gain
AFactor: Antenna Factor at 3m
During the test, the total correction Factor AT and AFactor were built in test software.
Note: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis
test condition was recorded in this test report
A. Test Verdict:
                                     Receiver                                               Max.
                 Detector
  Frequency                          Reading                                 AFactor      Emission   Limit
                                                         AT (dB)                                                                Verdict
    (MHz)                               UR                                 (dB@3m)           E     (dBµV/m)
                      QP
                                      (dBuV)                                              (dBµV/m)
    908.4             QP                94.43             -34.00               22.20         82.54               94              PASS
    916.0             QP                89.13             -34.00               22.20         77.33               94              PASS




                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                       Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China    Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page 16 of 26


                                                                                          REPORT No.:SZ19050444W02

2.5. Radiated Emission and field strength of harmonics

2.5.1. Requirement

According to section 15.249(a), the field strength of emissions from intentional radiators operated
within these frequency bands shall comply with the following:

   Fundamental                 Field strength of fundamental                                    Field strength of harmonics
    frequency                         (millivolts/meter)                                             (microvolts/meter)

   902-928 MHz                                          50                                                        500

 2400-2483.5 MHz                                        50                                                        500

  5725-5875 MHz                                         50                                                        500

  24.0-24.25 GHz                                       250                                                        2500
According to section 15.249(d), Emission Radiated outside of the specified frequency bands,
except for harmonics, shall be attenuated by at least 50dB below the level of the fundamental or to
the general radiated emission limits in Section 15.209:
                                                                              Field Strength Limitation at 3m Measurement
  Frequency        Field Strength               Measurement
                                                                                                Distance
    (MHz)              (µV/m)                   Distance (m)
                                                                                       (uV/m)                         (dBuV/m)
                                                                                    10000*
 0.009 - 0.490      2400/F(kHz)                          300                                                 20log 2400/F(KHz) + 80
                                                                                  2400/F(KHz)
 0.490 - 1.705     24000/F(kHz)                           30                  100* 2400/F(KHz)               20log 2400/F(KHz) + 40
 1.705 - 30.0                30                           30                           100*30                      20log 30 + 40
    30 - 88                 100                            3                            100                           20log 100
   88 - 216                 150                            3                            150                           20log 150
   216 - 960                200                            3                            200                           20log 200
  Above 960                 500                            3                            500                           20log 500
According to section 15.249(e), for frequencies above 1000MHz, the above field strength limits are
based on average limits. The peak field strength of any emission shall not exceed the maximum
permitted average limits specified above by more than 20dB under any condition of modulation.
Note:
1) The tighter limit shall apply at the boundary between two frequency range.
2) Limitation expressed in dBuV/m is calculated by 20log Emission Level(uV/m).
3) If measurement is made at 3m distance, then F.S Limitation at 3m distance is adjusted by using
theformula of Ld1 = Ld2 * (d2/d1)2.
Example: F.S Limit at 30m distance is 30uV/m, then F.S Limitation at 3m distance is adjusted as
Ld1 = L1 = 30uV/m * (10)2 = 100 * 30uV/m


                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                           Tel: 86-755-36698555   Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China       Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                         Page 17 of 26


                                                                                    REPORT No.:SZ19050444W02

2.5.2. Test Description

A. Test Setup:

   1)   For radiated emissions from 9kHz to 30MHz




   2)   For radiated emissions from 30MHz to1GHz




              SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                    Tel: 86-755-36698555   Fax: 86-755-36698525
              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page 18 of 26


                                                                                      REPORT No.:SZ19050444W02

    3)   For radiated emissions above 1GHz




The RF absorbing material used on the reference ground plane and on the turntable have a
maximum height (thickness) of 30 cm (12 in) and have a minimum-rated attenuation of 20 dB at all
frequencies from 1 GHz to 18 GHz. Test site have a minimum area of the ground plane covered
with RF absorbing material as specified in Figure 6 of ANSI C63.4: 2014.

The test site semi-anechoic chamber has met the requirement of NSA tolerance 4dB according to
the standards: ANSI C63.10 (2013). For radiated emissions below or equal to 1GHz, The EUT was
set-up on insulator 80cm above the Ground Plane, For radiated emissions above 1GHz, The EUT
was set-up on insulator 150cm above the Ground Plane. The set-up and test methods were
according to ANSI C63.10

For the radiated emission test above 1GHz:

Place the measurement antenna away from each area of the EUT determined to be a source of
emissions at the specified measurement distance, while keeping the measurement antenna aimed
at the source of emissions at each frequency of significant emissions, with polarization oriented for
maximum response. The measurement antenna may have to be higher or lower than the EUT,
depending on the radiation pattern of the emission and staying aimed at the emission source for
receiving the maximum signal. The final measurement antenna elevation shall be that which
maximizes the emissions. The measurement antenna elevation for maximum emissions shall be
restricted to a range of heights of from 1 m to 4 m above the ground or reference ground plane.
The EUT is located in a 3m Semi-Anechoic Chamber; the antenna factors, cable loss and so on of
the site as factors are calculated to correct the reading

                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                      Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 19 of 26


                                                                                       REPORT No.:SZ19050444W02

For the Test Antenna:

(a) In the frequency range of 9kHz to 30MHz, magnetic field is measured with Loop Test Antenna.
The Test Antenna is positioned with its plane vertical at 1m distance from the EUT. The center of
the Loop Test Antenna is 1m above the ground. During the measurement the Loop Test Antenna
rotates about its vertical axis for maximum response at each azimuth about the EUT.
(b) In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn Test
Antenna (above 1GHz) are used. Place the test antenna at 3m away from area of the EUT, while
keeping the test antenna aimed at the source of emissions at each frequency of significant
emissions, with polarization oriented for maximum response. The test antenna may have to be
higher or lower than the EUT, depending on the radiation pattern of the emission and staying aimed
at the emission source for receiving the maximum signal. The final test antenna elevation shall be
that which maximizes the emissions. The test antenna elevation for maximum emissions shall be
restricted to a range of heights of from 1 m to 4 m above the ground or reference ground plane.
The emission levels at both horizontal and vertical polarizations should be tested.


2.5.3. Test Result

According to ANSI C63.10, because of peak detection will yield amplitudes equal to or greater than
amplitudes measured with the quasi-peak (or average) detector, the measurement data from a
spectrum analyzer peak detector will represent the worst-case results, if the peak measured value
complies with the quasi-peak limit, it is unnecessary to perform an quasi-peak measurement.

The measurement results are obtained as below:
    E [dBμV/m] =UR + AT + AFactor [dB]; AT =LCable loss [dB]-Gpreamp [dB]
    AT: Total correction Factor except Antenna
    UR: Receiver Reading
    Gpreamp: Preamplifier Gain
    AFactor: Antenna Factor at 3m

During the test, the total correction Factor AT and AFactor were built in test software.

Note1: All radiated emission tests were performed in X, Y, Z axis direction. And only the worst axis
test condition was recorded in this test report.

Note2: For the frequency, which started from 9 kHz to 30MHz, was pre-scanned and the result
which was 20dB lower than the limit was not recorded.




                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                       Tel: 86-755-36698555   Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page 20 of 26


                                                                                         REPORT No.:SZ19050444W02




   Fre.        Pk             QP                AV               Limit-PK            Limit-QP       Limit-AV
                                                                                                                   Antenna          Verdict
  (MHz)     (dBμV/m)       (dBμV/m)          (dBμV/m)           (dBμV/m)            (dBμV/m)       (dBμV/m)
 131.977      38.33           N/A               N/A                N/A                 43.50          N/A          Horizontal        PASS
 908.949     74.70              N/A               N/A               N/A              46.00             N/A         Horizontal          N/A
 4541.844    49.76              N/A               N/A              74.00              N/A             54.00        Horizontal        PASS
 5450.191    48.97              N/A               N/A              74.00              N/A             54.00        Horizontal        PASS
 8175.232    47.93              N/A               N/A              74.00              N/A             54.00        Horizontal        PASS
 9083.579    49.63              N/A               N/A              74.00              N/A             54.00        Horizontal        PASS
                            (908.4MHz, Antenna Horizontal, 30MHz to 10GHz)




   Fre.        Pk              QP                AV              Limit-PK            Limit-QP       Limit-AV
                                                                                                                   Antenna        Verdict
  (MHz)     (dBμV/m)        (dBμV/m)          (dBμV/m)          (dBμV/m)            (dBμV/m)       (dBμV/m)
 124.693      38.13            N/A               N/A               N/A                 43.50          N/A          Vertical        PASS
 908.949     74.14              N/A               N/A               N/A               46.00             N/A        Vertical         N/A
 2496.279    47.25              N/A               N/A              74.00              N/A             54.00        Vertical        PASS
 4541.844    50.45              N/A               N/A              74.00              N/A             54.00        Vertical        PASS
 5450.191    47.75              N/A               N/A              74.00              N/A             54.00        Vertical        PASS
 7907.438    47.08              N/A               N/A              74.00              N/A             54.00        Vertical        PASS
                              (908.4MHz, Antenna Vertical, 30MHz to 10GHz)




              SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                            Tel: 86-755-36698555   Fax: 86-755-36698525
              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China           Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                          Page 21 of 26


                                                                                          REPORT No.:SZ19050444W02




   Fre.        Pk             QP                AV              Limit-PK             Limit-QP        Limit-AV
                                                                                                                    Antenna          Verdict
  (MHz)     (dBμV/m)       (dBμV/m)          (dBμV/m)          (dBμV/m)             (dBμV/m)        (dBμV/m)
 129.549      38.89           N/A               N/A               N/A                  43.50           N/A          Horizontal        PASS
 916.233     73.38              N/A               N/A               N/A               46.00             N/A         Horizontal         N/A
 2034.654    47.10              N/A               N/A             74.00                N/A             54.00        Horizontal        PASS
 4579.524    50.11              N/A               N/A             74.00                N/A             54.00        Horizontal        PASS
 5495.945    48.02              N/A               N/A             74.00                N/A             54.00        Horizontal        PASS
 8244.200    51.73              N/A             44.73             74.00                N/A             54.00        Horizontal        PASS
                             (916MHz, Antenna Horizontal, 30MHz to 10GHz)




   Fre.        Pk             QP                AV              Limit-PK             Limit-QP       Limit-AV
                                                                                                                    Antenna       Verdict
  (MHz)     (dBμV/m)       (dBμV/m)          (dBμV/m)          (dBμV/m)             (dBμV/m)       (dBμV/m)
 128.335      38.94           N/A               N/A               N/A                  43.50          N/A           Vertical       PASS
 916.233     72.65             N/A               N/A               N/A               46.00              N/A         Vertical        N/A
 2493.077    47.49             N/A               N/A              74.00               N/A             54.00         Vertical       PASS
 3142.317    46.15             N/A               N/A              74.00               N/A             54.00         Vertical       PASS
 4579.524    49.60             N/A               N/A              74.00               N/A             54.00         Vertical       PASS
 8243.863    48.72             N/A               N/A              74.00               N/A             54.00         Vertical       PASS
                                (916MHz, Antenna Vertical, 30MHz to 10GHz)




              SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                             Tel: 86-755-36698555   Fax: 86-755-36698525
              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China            Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                           Page 22 of 26


                                                                                      REPORT No.:SZ19050444W02

Annex A Test Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for test
performed on the EUT as specified in CISPR 16-1-2:
 Test items                                                                 Uncertainty
 Bandwidth                                                                  ±5%
 Radiated Emission                                                          ±2.95dB
This uncertainty represent an expanded uncertainty expressed at approximately the 95%
confidence level using a coverage factor of k=2




              SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                      Tel: 86-755-36698555   Fax: 86-755-36698525
              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China     Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 23 of 26


                                                                                     REPORT No.:SZ19050444W02

Annex B Testing Laboratory Information
1. Identification of the Responsible Testing Laboratory

 Laboratory Name:                             Shenzhen Morlab Communications Technology Co., Ltd.
                                              Morlab Laboratory
 Laboratory Address:                          FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                              Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                              Province, P. R. China
 Telephone:                                   +86 755 36698555
 Facsimile:                                   +86 755 36698525

2. Identification of the Responsible Testing Location

                                               Shenzhen Morlab Communications Technology Co., Ltd.
 Name:
                                               Morlab Laboratory
                                               FL.3, Building A, FeiYang Science Park, No.8 LongChang
 Address:                                      Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                               Province, P. R. China

3. Facilities and Accreditations

All measurement facilities used to collect the measurement data are located at FL.3, Building A,
FeiYang Science Park, Block 67, BaoAn District, Shenzhen, 518101 P. R. China. The test site is
constructed in conformance with the requirements of ANSI C63.10-2013 and CISPR Publication 22;
the FCC designation number is CN1192, the test firm registration number is 226174.




               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                     Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 24 of 26


                                                                                            REPORT No.:SZ19050444W02

4. Test Equipments Utilized

4.1 Conducted Test Equipments
Equipment Name              Serial No.                   Type                 Manufacturer                   Cal. Date                Cal. Due
  Attenuator 1                 (N/A.)                    10dB                          Resnet                       N/A                      N/A
   EXA Signal
                         MY53470836                   N9010A                           Agilent              2019.04.09              2020.04.08
    Analzyer
   RF cable
                                CB01                     RF01                          Morlab                       N/A                      N/A
(30MHz-26GHz)
  Coaxial cable                 CB02                     RF02                          Morlab                       N/A                      N/A
 SMA connector                  CN01                   RF03               HUBER-SUHNER                              N/A                      N/A
   Computer                     T430i                Think Pad               Lenovo                                 N/A                      N/A


4.2 Conducted Emission Test Equipments
 Equipment Name                 Serial No.                    Type                Manufacturer                Cal. Date              Cal. Due
      Receiver                 MY56400093                    N9038A                KEYSIGHT                  2019.05.08             2020.05.09
                                                               NSLK
       LISN                         812744                                         Schwarzbeck               2019.05.08             2020.05.09
                                                               8127
                                                               VTSD
Pulse Limiter (20dB)                  9391                                         Schwarzbeck               2019.05.08             2020.05.09
                                                              9561-D
Coaxial cable(BNC)
                                     CB01                     EMC01                      Morlab                     N/A                      N/A
 (30MHz-26GHz)

4.3 List of Software Used

                                   Description                                           Manufacturer                 Software Version

                          Test system                                                       Tonscend                             V2.6
                          Power Panel                                                        Agilent                             V3.8
                  MORLAB EMCR V1.2                                                          MORLAB                               V 1.0




                 SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                             Tel: 86-755-36698555     Fax: 86-755-36698525
                 FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                 Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China         Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                             Page 25 of 26


                                                                                            REPORT No.:SZ19050444W02

4.4 Radiated Test Equipments
   Equipment
                              Serial No.                      Type                 Manufacturer               Cal. Date              Cal. Due
     Name
    Receiver               MY54130016                      N9038A                        Agilent             2019.07.26            2020.07.05
  Test Antenna -
                               9163-519                 VULB 9163                   Schwarzbeck              2019.05.08            2020.05.09
      Bi-Log
  Test Antenna -
                               1519-022                  FMZB1519                   Schwarzbeck              2019.02.15            2020.02.14
       Loop
  Test Antenna –
                                 01774                 BBHA 9120D                   Schwarzbeck              2019.07.26            2020.07.05
       Horn
  Test Antenna –             BBHA9170
                                                         BBHA9170                   Schwarzbeck              2019.07.26            2020.07.05
       Horn                    #774
   Coaxial cable
     (N male)                     CB04                      EMC04                        Morlab                     N/A                  N/A
  (9KHz-30MHz)
   Coaxial cable
     (N male)                     CB02                      EMC02                        Morlab                     N/A                  N/A
 (30MHz-26GHz)
   Coaxial cable
     (N male)                     CB03                      EMC03                        Morlab                     N/A                  N/A
 (30MHz-26GHz)
     1-18GHz                                                                             Rohde&
                                  MA02                    TS-PR18                                            2019.05.08            2020.05.09
   pre-Amplifier                                                                         Schwarz
   18-26.5GHz                                                                            Rohde&
                                  MA03                    TS-PR18                                            2019.05.08            2020.05.09
   pre-Amplifier                                                                         Schwarz
                                                       WRCG-2400-
   Notch Filter                     N/A                                                 Wainwright           2018.12.01            2019.11.30
                                                       2483.5-60SS
    Anechoic
                                    N/A                  9m*6m*6m                         CRT                2017.11.19            2020.11.18
    Chamber


                                                           END OF REPORT




                  SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
MORLAB
                                                                                             Tel: 86-755-36698555    Fax: 86-755-36698525
                  FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                  Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China        Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                            Page 26 of 26



Document Created: 2019-09-23 14:36:09
Document Modified: 2019-09-23 14:36:09

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC