RF Test Report

FCC ID: 2AMW3-TL697A

Test Report

Download: PDF
FCCID_4431474

                         Test Report No.:RF190715N011


                                                                   TEST REPORT
       Applicant                       LI XIONG SHENG TOYS FACTORY

                                       BEIWAN INDUSTRIAL AREA, LIANXIA TOWN, CHENGHAI DISTRICT, SHANTOU
       Address
                                       CITY, GUANGDONG PROVINCE, CHINA


       Manufacturer or
                                       LI XIONG SHENG TOYS FACTORY
       Supplier
                                       BEIWAN INDUSTRIAL AREA, LIANXIA TOWN, CHENGHAI DISTRICT, SHANTOU
       Address
                                       CITY, GUANGDONG PROVINCE, CHINA
       Product                         Toy series

       Brand Name                      N/A

       Model                           697A
       Additional Model &
                                       695A, 695A-1, 696A, etc.; see item 3.1
       Model Difference:

       Date of tests                   Jul. 15, 2019 ~ Aug. 05, 2019

       the tests have been carried out according to the requirements of the following standards:

            FCC Part 15, Subpart C, Section 15.227

       CONCLUSION: The submitted sample was found to COMPLY with the test requirement

                            Tested by Lucas Chen                                                          Approved by Breeze Jiang
                     Project Engineer / EMC Department                                            Senior Project Engineer / EMC Department




                                                                                                                   Date: Aug. 29, 2019
       This report is governed by, and incorporates by reference, CPS Conditions of Service as posted at the date of issuance of this report at
       http://www.bureauveritas.com/home/about-us/our-business/cps/about-us/terms-conditions/and is intended for your exclusive use. Any copying or
       replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report
       sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the
       quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our
       report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. Measurement uncertainty is
       only provided upon request for accredited tests. You have 60 days from date of issuance of this report to notify us of any material error or omission caused
       by our negligence or if you require measurement uncertainty; provided, however, that such notice shall be in writing and shall specifically address the
       issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute you unqualified acceptance of the completeness of this
       report, the tests conducted and the correctness of the report contents.


                                                          No. 34, Chenwulu Section, Guantai Rd., Houjie                Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                          Town, Dongguan City,                                         Fax: +86 769 8593 1080
Dongguan Branch                                           Guangdong 523942, China                                      Email: DGservice@cn.bureauveritas.com
                                                                               Page 1 of 20                                                                Report Version 1


                       Test Report No.:RF190715N011



                                                        TABLE OF CONTENTS
          RELEASE CONTROL RECORD ............................................................................................................ 3
          1    SUMMARY OF TEST RESULTS ..................................................................................................... 4
          2    MEASUREMENT UNCERTAINTY................................................................................................... 4
          3    GENERAL INFORMATION .............................................................................................................. 5

              3.1     GENERAL DESCRIPTION OF EUT ........................................................................................... 5
              3.2     DESCRIPTION OF TEST MODES ............................................................................................. 6
              3.3     GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................ 6
              3.4     DESCRIPTION OF SUPPORT UNITS ....................................................................................... 6

          4    TEST TYPES AND RESULTS ......................................................................................................... 7

              4.1     RADIATED EMISSION MEASUREMENT .................................................................................. 7
                 4.1.1      LIMITS OF RADIATED EMISSION MEASUREMENT ...................................................... 7
                 4.1.2      TEST INSTRUMENTS ....................................................................................................... 8
                 4.1.3      TEST PROCEDURES ....................................................................................................... 8
                 4.1.4      DEVIATION FROM TEST STANDARD ............................................................................. 9
                 4.1.5      TEST SETUP ................................................................................................................... 10
                 4.1.6      EUT OPERATING CONDITIONS .....................................................................................11
                 4.1.7      TEST RESULTS ...............................................................................................................11
              4.2     20dB BANDWIDTH MEASUREMENT...................................................................................... 16
                    4.2.1     LIMITS OF 20dB BANDWIDTH MEASUREMENT ......................................................... 16
                    4.2.2     TEST INSTRUMENTS ................................................................................................... 16
                    4.2.3     TEST PROCEDURE ...................................................................................................... 16
                    4.2.4     DEVIATION FROM TEST STANDARD .......................................................................... 17
                    4.2.5     TEST SETUP ................................................................................................................. 17
                    4.2.6     EUT OPERATING CONDITIONS................................................................................... 17
                    4.2.7     TEST RESULTS ............................................................................................................. 18

          5    PHOTOGRAPHS OF THE TEST CONFIGURATION .................................................................... 19
          6    APPENDIX A - MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT
               BY THE LAB .................................................................................................................................. 20




                                                       No. 34, Chenwulu Section, Guantai Rd., Houjie               Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                                       Town, Dongguan City,                                        Fax: +86 769 8593 1080
Dongguan Branch                                        Guangdong 523942, China                                     Email: DGservice@cn.bureauveritas.com
                                                                           Page 2 of 20                                                              Report Version 1


                    Test Report No.:RF190715N011



                                      RELEASE CONTROL RECORD

           ISSUE NO.                REASON FOR CHANGE                                                    DATE ISSUED
           RF190715N011             Original release                                                     Aug. 29, 2019




                                             No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                             Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                              Guangdong 523942, China                         Email: DGservice@cn.bureauveritas.com
                                                             Page 3 of 20                                              Report Version 1


                    Test Report No.:RF190715N011

          1 SUMMARY OF TEST RESULTS
          The EUT has been tested according to the following specifications:
                     APPLIED STANDARD: FCC PART 15, SUBPART C , SECTION 15.227(2015-10)
            STANDARD
                                    TEST TYPE AND LIMIT                  RESULT                    REMARK
             SECTION
           §15.207 (a)          AC Power Conducted Emission                N/A           EUT is powered by battery
            §15.209
                                     Radiated Emission                    PASS                    Compliant
            §15.227
            §15.215(c)              20dB Bandwidth Test                   PASS                    Compliant
                                                                                         No antenna connector is
              §15.203               Antenna Requirement                   PASS
                                                                                                 used



          2 MEASUREMENT UNCERTAINTY
          Where relevant, the following measurement uncertainty levels have been estimated
          for tests performed on the EUT as specified in CISPR 16-4-2:
                      MEASUREMENT                           FREQUENCY                          UNCERTAINTY
                                                           9KHz ~ 30MHz                              2.90dB
                                                           30MHz ~ 1GHz                              3.76dB
                     Radiated emissions
                                                           1GHz ~ 18GHz                              4.84dB
                                                          18GHz ~ 40GHz                              4.96dB

          This uncertainty represents an expanded uncertainty expressed at approximately the
          95% confidence level using a coverage factor of k = 2.




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie    Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                             Fax: +86 769 8593 1080
Dongguan Branch                          Guangdong 523942, China                          Email: DGservice@cn.bureauveritas.com
                                                         Page 4 of 20                                               Report Version 1


                    Test Report No.:RF190715N011

          3 GENERAL INFORMATION
          3.1 GENERAL DESCRIPTION OF EUT

          PRODUCT                           Toy series
          MODEL NO.                         697A
                                            695A, 695A-1, 696A, 696A-2, 698A, 699A, 697A-1, 698A-2,
                                            699A-3, 700A, 701A, 700A-1, 701A-2, 702A, 703A, 702A-1,
                                            703A-2, 704A, 704A-1, 705A, 705A-2, 706A-1, 706A-2,
                                            706A-3, 706A-4, 707A, 708A, 709A, 707A-1, 708A-2, 709A-3,
                                            710, 710A-1, 711, 711A-2, 712, 713, 173, 174, 175, 176, 177,
                                            173A, 174A, 175A, 176A, 177A, 178, 179, 180, 181, 182,
                                            178A, 179A, 180A, 181A, 182A, 686, 687, 688, 689, 690,
                                            686A, 687A, 688A, 689A, 690A, 274A, 275A, 276A, 277A,
                                            278A, 288A, 311, 312, 313, 314, 315, 316, 634, 635, 636,
          ADDITIONAL MODELS                 634A, 635A, 636A, 637A, 638A, 639A, 646A, 647A, 648A,
                                            649A, 650A, 651A, 655A, 656A, 657A, 664A, 665A, 666A,
                                            667A, 668A, 669A, 676A, 677A, 682A, 683A, 274A-1, 275A-2,
                                            276A-3, 277A-1, 278A-2, 288A-3, 634-1, 635-2, 636-3,
                                            634A-1, 635A-2, 636A-3, 173A-1, 174A-2, 175A-3, 176A-4,
                                            177A-5, 178A-1, 179A-2, 180A-3, 181A-4, 182A-5, 686-1,
                                            687-2, 688-3, 689-4, 690-5, 686A-1, 687A-2, 688A-3, 689A-4,
                                            690A-5, 637, 638, 637A-1, 638A-2, 639, 640, 639A-1, 640A-2,
                                            641, 642, 641A-1, 642A-2, 691A, 692A, 691A-1, 692A-2,
                                            693A, 693A-1, 694A, 694A-2
          FCC ID                            2AMW3-TL697A
          NOMINAL VOLTAGE                   DC 3V(1.5V*AA*2) from Battery
          MODULATION TYPE                   ASK
          OPERATING FREQUENCY               27.145MHz
          NUMBER OF CHANNEL                 1
          ANTENNA TYPE                      Spring Antenna, with 0dBi gain
          I/O PORTS                         Refer to user’s manual

          NOTES:

          1. For a more detailed features description, please refer to the manufacturer’s specifications or the
             user's manual.
          2. For the test results, the EUT had been tested with all conditions, but only the worst case was
             shown in test report.
          3. Please refer to the EUT photo document (Reference No.: 190715N011) for detailed product photo
          4. Additional models (see above table) are identical with the test model 697A except the color of
              appearance, shape of appearance, silk-screen and model number for trading purpose.




                                         No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                         Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                          Guangdong 523942, China                         Email: DGservice@cn.bureauveritas.com
                                                         Page 5 of 20                                              Report Version 1


                    Test Report No.:RF190715N011

          3.2 DESCRIPTION OF TEST MODES
          Pre-Scan has been conducted to determine the worst-case mode from all possible
          combinations between available modulations, data rates, XYZ axis and packet type.
          The worst case was found when the EUT was positioned on Y axis for radiated
          emission. The EUT was tested under the following mode.


                                FREQUENCY                        TEST MODES
                                    27.145 MHz                    Transmitting


          3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS

           The EUT is a RF Product. According to the specifications of the manufacturer, it
           must comply with the requirements of the following standards:

           FCC Part 15, Subpart C, 15.227
           ANSI C63.10-2013

           All test items have been performed and recorded as per the above standards.



          3.4 DESCRIPTION OF SUPPORT UNITS

             The EUT has been tested as an independent unit without any other necessary
             accessories or support units.




                                           No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                           Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                            Guangdong 523942, China                         Email: DGservice@cn.bureauveritas.com
                                                           Page 6 of 20                                              Report Version 1


                    Test Report No.:RF190715N011

          4      TEST TYPES AND RESULTS

          4.1 RADIATED EMISSION MEASUREMENT

          4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT

              Emissions radiated outside of the specified bands, shall be according to the
              general radiated limits in 15.209 as following:
                     FREQUENCIES                 FIELD STRENGTH                   MEASUREMENT DISTANCE
                        (MHz)                    (microvolts/meter)                     (meters)
                      0.009 ~ 0.490                   2400/F(kHz)                                 300
                      0.490 ~ 1.705                  24000/F(kHz)                                  30
                       1.705 ~ 30.0                          30                                    30
                          30 ~ 88                           100                                     3
                         88 ~ 216                           150                                     3
                        216 ~ 960                           200                                     3
                        Above 960                           500                                     3


              According to §15.227(a), the field strength of emissions from intentional radiators
              operated within these frequency bands shall comply with the following:
                                                 Field Strength of                        Field Strength of
               Frequency Range of
                                              Fundamental Emission                     Fundamental Emission
                  Fundamental
                                                      [Peak]                                  [Average]
                     [MHz]
                                                       µV/m]
                                                      [µ                                         µV/m]
                                                                                                [µ
                   26.96 – 27.28               100,000 (100 dBµV/m)                      10,000 (80 dBµV/m)
               NOTES:
               1. The lower limit shall apply at the transition frequencies.
               2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
               3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on
                  average detector, however, the peak field strength of any emission shall not exceed the
                  maximum permitted average limits, specified above by more than 20dB under any condition of
                  modulation.




                                            No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                            Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                             Guangdong 523942, China                         Email: DGservice@cn.bureauveritas.com
                                                            Page 7 of 20                                              Report Version 1


                    Test Report No.:RF190715N011

          4.1.2 TEST INSTRUMENTS


           9KHz~30MHz
        Equipment                   Manufacturer       Model No.           Serial No.          Last Cal.       Next Cal.
        EMI Test Receiver   Rohde&Schwarz ESR7                             101564              Mar. 12,19      Mar. 11,20
        Active Loop Antenna SCHWARZBECK FMZB 1519B                         1519B-045           May 04,19       May 03,20
        Amplifier           Burgeon       BPA-530                          100210              Apr. 17,19      Apr. 18,20
                                          ADT_Radiated
        Test Software       ADT                                            N/A                 N/A             N/A
                                          _V8.7.07
             NOTES: 1. The calibration interval of the above test instruments is 12 months and the calibrations
                         are traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
                      2. The test was performed in 10m Chamber
                      3. The FCC Site Registration No. is 749762.


          30MHz~1GHz
          Equipment                  Manufacturer              Model No.         Serial No.          Last Cal. Next Cal.
          EMI Test Receiver          Rohde&Schwarz             ESU40             100449              Mar. 12,19 Mar. 11,20
          Bilog Antenna              Teseq                     CBL 6111D         30643               Aug.11,18    Aug. 10,19
          Amplifier                  Burgeon                   BPA-530           100220              Apr. 17,19 Apr. 18,20
          3m Semi-anechoic
                                     ETS-LINDGREN              9m*6m*6m          NSEMC003            Feb. 10,18 Feb. 09,20
          Chamber
                                                               ADT_Radiated
          Test software              ADT                                    N/A                      N/A          N/A
                                                               _V7.6.15.9.2
          NOTES:
             1. The test was performed in 966 Chamber (a 3m Semi-anechoic chamber).
             2. The calibration interval of the above test instruments are 12 months and the calibrations are
                traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.
             3. The horn antenna is used only for the measurement of emission frequency above1GHz if tested.
             4. The FCC Site Registration No. is 749762.




                                               No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                               Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                                Guangdong 523942, China                         Email: DGservice@cn.bureauveritas.com
                                                               Page 8 of 20                                              Report Version 1


                    Test Report No.:RF190715N011

          4.1.3 TEST PROCEDURES
          The basic test procedure was in accordance with ANSI C63.10 (section 6).
           a. The EUT was placed on the top of a rotating table 0.8 meters above the
              ground at a 3m chamber room. The table was rotated 360 degrees to
              determine the position of the highest radiation. (Below 1000MHz)
           b. The EUT was placed on the top of a rotating table 0.8 meters above the
              ground at a 10m chamber room. The table was rotated 360 degrees to
              determine the position of the highest radiation. (Below 30MHz)
           c. The EUT was set 3 meters away from the interference-receiving antenna,
              which was mounted on the top of a variable-height antenna tower.
           d. The height of antenna is varied from one meter to four meters above the
              ground to determine the maximum value of the field strength. Both horizontal
              and vertical polarizations of the antenna are set to make the measurement.
           e. For each suspected emission, the EUT was arranged to its worst case and
              then the antenna was tuned to heights from 1 meter to 4 meters and the
              rotatable table was turned from 0 degrees to 360 degrees to find the
              maximum reading.
           f. The test-receiver system was set to quasi-peak detect function and specified
              bandwidth with maximum hold mode when the test frequency is below 1 GHz.
           g. During the test, each emission was maximized by: having the EUT
              continuously working, investigated all operating modes, rotated about all 3 axis
              (X, Y & Z) and considered typical configuration to obtain worst position Y,
              manipulating interconnecting cables, For battery operated equipment, the
              equipment tests shall be perform using new battery. The turntable was rotated
              to maximize the emission level.
           h. For below 30MHz, a loop antenna with its vertical plane is place 3m from the
              EUT and rotated about its vertical axis for maximum response at each azimuth
              about the EUT. And the centre of the loop shall be 1m above the ground.
           NOTES:
            1. The resolution bandwidth of test receiver/spectrum analyzer is 120kHz for Quasi-peak detection
               (QP) at frequency below 1GHz.
            2. Emission level(dBuV/m)=Raw Value(dBuV) + Correction Factor(dB/m)
            3. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
            4. Margin value = Emission level – Limit value.
            5. Fundamental AV value =PK Emission +AV Factor.


          4.1.4 DEVIATION FROM TEST STANDARD

           No deviation.




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                         Guangdong 523942, China                         Email: DGservice@cn.bureauveritas.com
                                                        Page 9 of 20                                              Report Version 1


                    Test Report No.:RF190715N011

          4.1.5 TEST SETUP



          Below 30MHz test setup




          Below 1GHz test setup

                                                                          Ant. Tower
                                                                                                    1-4m
                                                         3m
                                    EUT

                                                  Turn Table

                           0.8m


                                                       Ground Plane

                                                       Spectrum




          Note: For the actual test configuration, please refer to the attached file (Test Setup Photo).




                                           No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                           Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                            Guangdong 523942, China                         Email: DGservice@cn.bureauveritas.com
                                                          Page 10 of 20                                              Report Version 1


                      Test Report No.:RF190715N011

          4.1.6 EUT OPERATING CONDITIONS


                a. Turned on the power of equipment.
                b. Hold down the TX of button, then the EUT was operating.
                c. EUT was operated according to the type used was description in
                      manufacturer’s specifications or the User's Manual.

          4.1.7 TEST RESULTS

             FIELD STRENGTH OF FUNDAMENTAL


             ANTENNA POLARITY: 0°
                                       Correction         Raw            Emission
                            Freq.                                                            Limit         Margin
                No.                     Factor            Value            Level
                           (MHz)                                                           (dBuV/m)         (dB)
                                        (dB/m)           (dBuV)          (dBuV/m)
                 *      27.145(PK)        -9.50           78.49            68.99             100            -31.01
                 *      27.145(AV)        -4.44             -              64.55             80             -15.45


             ANTENNA POLARITY: 90°
                                       Correction         Raw            Emission
                            Freq.                                                            Limit         Margin
                No.                     Factor            Value            Level
                           (MHz)                                                           (dBuV/m)         (dB)
                                        (dB/m)           (dBuV)          (dBuV/m)
                 *      27.145(PK)        -9.50           78.42            68.92             100            -31.08
                 *      27.145(AV)        -4.44             -              64.48             80             -15.52

              REMARKS: 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                            2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                            3. Margin value = Emission level – Limit value.
                            4. “ * “: Fundamental frequency.
                            5. The average value of fundamental frequency is: Average value = Peak value +AV
                                factor, where the AV factor is calculated from following formula: AV factor=20 log
                                (Duty cycle) = 20 log (60%) = -4.44dB, Please see page 12~13 for plotted duty.




                                           No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                           Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                            Guangdong 523942, China                         Email: DGservice@cn.bureauveritas.com
                                                          Page 11 of 20                                              Report Version 1


                    Test Report No.:RF190715N011

          Duty Cycle:
               Tp = 17.69ms

                 Ton = Ton1 * Number+ Ton2 * Number =0.4797*10 +1.4477*4= 10.5878ms

                 Duty Cycle = Ton / Tp * 100% = 10.5878/ 17.69= 60%


          Tp=17.69ms




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                       Guangdong 523942, China                         Email: DGservice@cn.bureauveritas.com
                                                     Page 12 of 20                                              Report Version 1


                    Test Report No.:RF190715N011


          Ton1=0.479667ms
          Ton2=1.447667ms




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                       Guangdong 523942, China                         Email: DGservice@cn.bureauveritas.com
                                                     Page 13 of 20                                              Report Version 1


                    Test Report No.:RF190715N011



                                                                  DETECTOR
          FREQUENCY RANGE             9KHz ~ 1GHz                                                Quasi-Peak (QP)
                                                                  FUNCTION


                             ANTENNA POLARITY & TEST DISTANCE: HORIZONTAL AT 3 M
                              EMISSION                               ANTENNA          TABLE           RAW      CORRECTION
                   FREQ.                    LIMIT       MARGIN
          NO.                  LEVEL                                  HEIGHT          ANGLE          VALUE       FACTOR
                   (MHz)                  (dBuV/m)       (dB)
                              (dBuV/m)                                  (m)          (Degree)        (dBuV)       (dB/m)
            1      30.00       20.24 QP    40.00         -19.76        2.00 H             145        30.34         -10.10
            2      53.32       16.36 QP    40.00         -23.64        2.00 H             173        38.40         -22.04
            3      225.87      17.28 QP    46.00         -28.72        2.00 H             180        34.16         -16.88
            4      379.76      23.79 QP    46.00         -22.21        2.00 H             137        33.63         -9.84
            5      407.74      22.97 QP    46.00         -23.03        2.00 H             240        32.22         -9.25
            6      515.00      22.18 QP    46.00         -23.82        2.00 H             175        29.40         -7.22
          REMARKS:
                 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                 2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                 3. The emission levels of other frequencies were less than 20dB margin against the limit.
                 4. Margin value = Emission level – Limit value.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch                           Guangdong 523942, China                           Email: DGservice@cn.bureauveritas.com
                                                         Page 14 of 20                                                Report Version 1


                    Test Report No.:RF190715N011



                                                                  DETECTOR
          FREQUENCY RANGE             9KHz ~ 1GHz                                                Quasi-Peak (QP)
                                                                  FUNCTION


                               ANTENNA POLARITY & TEST DISTANCE: VERTICAL AT 3 M
                              EMISSION                               ANTENNA          TABLE           RAW      CORRECTION
                   FREQ.                    LIMIT       MARGIN
          NO.                  LEVEL                                  HEIGHT          ANGLE          VALUE       FACTOR
                   (MHz)                  (dBuV/m)       (dB)
                              (dBuV/m)                                  (m)          (Degree)        (dBuV)       (dB/m)
            1      30.00       19.97 QP    40.00         -20.03         1.01 V            137        30.07         -10.10
            2      54.29       35.90 QP    40.00          -4.10         1.00 V            57         58.24         -22.34
            3      379.76      26.64 QP    46.00         -19.36         1.01 V            175        36.48         -9.84
            4      407.74      27.83 QP    46.00         -18.17         1.01 V            156        37.08         -9.25
            5      460.59      24.83 QP    46.00         -21.17         1.01 V            195        33.22         -8.39
            6      515.00      24.75 QP    46.00         -21.25         1.01 V            147        31.97         -7.22
          REMARKS:
                 1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m).
                 2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB).
                 3. The emission levels of other frequencies were less than 20dB margin against the limit.
                 4. Margin value = Emission level – Limit value.




                                          No. 34, Chenwulu Section, Guantai Rd., Houjie     Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                          Town, Dongguan City,                              Fax: +86 769 8593 1080
Dongguan Branch                           Guangdong 523942, China                           Email: DGservice@cn.bureauveritas.com
                                                         Page 15 of 20                                                Report Version 1


                    Test Report No.:RF190715N011

          4.2     BANDWIDTH MEASUREMENT
          4.2.1 LIMITS OF BANDWIDTH MEASUREMENT
          The field strength of any emissions appearing between the band edges and out of band shall
          be attenuated at least 20 dB below the level of the unmodulated carrier or to the general limits
          in Section 15.209.


                       FREQUENCY                              Limits
                          (MHz)                                [MHz]
                         27.145                         within 26.96-27.28



          4.2.2 TEST INSTRUMENTS

          Equipment                 Manufacturer          Model No.          Serial No.        Last Cal.      Next Cal.
          Power Sensor              Keysight              U2021XA            MY55060016        Jun. 13,19     Jun. 12,20
          Power Sensor              Keysight              U2021XA            MY55060018        Jun. 13,19     Jun. 12,20
          Power Meter               Anritsu               ML2495A            1139001           Mar. 12,19     Mar. 11,20
          Power Sensor              Anritsu               MA2411B            1531155           Mar. 12,19     Mar. 11,20
          Digital Multimeter        FLUKE                 15B                A1220010DG        Oct. 17, 18    Oct.16, 19
          Humid & Temp
                                    Haida                 HD-2257            110807201         Nov.15,18      Nov. 14,19
          Programmable Tester
          Oscilloscope              Agilent               DSO9254A           MY51260160 Nov. 09,18            Nov. 08,19
          Signal Analyzer           Rohde & Schwarz FSV7                     102331            Aug. 02,19     Aug. 01,20
          Signal Generator          Agilent               N5183A             MY50140980 Dec. 07,18            Dec. 06,19
          Agile Signal
                                    Agilent               8645A              Agilent           Oct.27, 18     Oct.26, 19
          Generator
          Spectrum Analyzer         Keysight              N9020A             MY55400499 Mar. 12,19            Mar. 11,20
          MXG-B RF Vector
                                    Keysight              N5182B             MY56200288 Dec. 07, 18           Dec. 06, 19
          Signal Generator
          BLUETOOTH
                                    Rohde&Schwarz CBT32                      100811            Jul.06, 19     Jul. 05, 20
          TESTER
          Attenuator                MINI                  BW-S10W2+          S130129FGE2 N/A                  N/A
          DC Source                 Keysight              E3642A             MY56146098 N/A                   N/A
          NOTES:
             1. The test was performed in RF Oven room.
             2. The calibration interval of the above test instruments is 12 months and the calibrations are
                traceable to CEPREI/CHINA, GRGT/CHINA and NIM/CHINA.




                                              No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                              Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                               Guangdong 523942, China                         Email: DGservice@cn.bureauveritas.com
                                                             Page 16 of 20                                              Report Version 1


                    Test Report No.:RF190715N011

          4.2.3 TEST PROCEDURE

            a. Check the calibration of the measuring instrument using either an internal
               calibrator or a known signal from an external generator.
            b. Turn on the EUT and connect it to measurement instrument. Then set it to any
               one convenient frequency within its operating range. Set a reference level on the
               measuring instrument equal to the highest peak value.
            c. Measure the frequency difference of two frequencies that were attenuated 20dB
               from the reference level. Record the frequency difference as the emission
               bandwidth.
            d. Repeat above procedures until all frequencies measured were complete.


          4.2.4 DEVIATION FROM TEST STANDARD

           No deviation.



          4.2.5 TEST SETUP



                          EUT                                               SPECTRUM

                                          10dB ATTENUATION PAD              ANALYZER




          4.2.6 EUT OPERATING CONDITIONS
                   Same as item 4.1.6




                                        No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                        Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                         Guangdong 523942, China                         Email: DGservice@cn.bureauveritas.com
                                                       Page 17 of 20                                              Report Version 1


                    Test Report No.:RF190715N011

          4.2.7 TEST RESULTS


                  Lower & Upper Test Frequency Point             Test Frequency
                                                                                                  P/F
                                (MHz)                                 (MHz)
                                Lower                               27.12199                     PASS
                                Upper                               27.16931                     PASS

           Test Data:




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                       Guangdong 523942, China                         Email: DGservice@cn.bureauveritas.com
                                                     Page 18 of 20                                              Report Version 1


                    Test Report No.:RF190715N011


          5     PHOTOGRAPHS OF THE TEST CONFIGURATION

           Please refer to the attached file (Test Setup Photo).




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                       Guangdong 523942, China                         Email: DGservice@cn.bureauveritas.com
                                                     Page 19 of 20                                              Report Version 1


                    Test Report No.:RF190715N011


          6     APPENDIX A - MODIFICATIONS RECORDERS FOR
                ENGINEERING CHANGES TO THE EUT BY THE LAB


           No any modifications are made to the EUT by the lab during the test.




           ---END---




                                      No. 34, Chenwulu Section, Guantai Rd., Houjie   Tel: +86 769 8998 2098
Bureau Veritas Shenzhen Co., Ltd.
                                      Town, Dongguan City,                            Fax: +86 769 8593 1080
Dongguan Branch                       Guangdong 523942, China                         Email: DGservice@cn.bureauveritas.com
                                                     Page 20 of 20                                              Report Version 1



Document Created: 2019-08-29 11:49:10
Document Modified: 2019-08-29 11:49:10

© 2024 FCC.report