Test report

FCC ID: 2AMTQMK3BLTV2

Test Report

Download: PDF
FCCID_4380143

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA




                                                  FCC TEST REPORT

                                                                 For

                                              AtGames Digital Media Inc.

                                              Bandai Namco Arcade Blast

                                                   Model No.: WD3305

                                 Additional Model: Please Refer to Page 6


 Prepared for                             :    AtGames Digital Media Inc.
 Address                                  :    2228 E Maple Ave, El Segundo, CA 90245, USA

 Prepared by                              :    Shenzhen LCS Compliance Testing Laboratory Ltd.
 Address                                  :    1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an
                                               District, Shenzhen, Guangdong, China
 Tel                                      :    (+86)755-82591330
 Fax                                      :    (+86)755-82591332
 Web                                      :    www.LCS-cert.com
 Mail                                     :    webmaster@LCS-cert.com

 Date of receipt of test sample           :    June 27, 2019
 Number of tested samples                 :    1
 Serial number                            :    Prototype
 Date of Test                             :    June 27, 2019 ~ July 10, 2019
 Date of Report                           :    July 11, 2019




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 1 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AMTQMK3BLTV2             Report No.: LCS190625047AEA


                                                  FCC TEST REPORT
                                              FCC CFR 47 PART 15 C(15.249)

 Report Reference No. ................. : LCS190625047AEA

 Date of Issue ................................... : July 11, 2019

 Testing Laboratory Name............. : Shenzhen LCS Compliance Testing Laboratory Ltd.

 Address ........................................... : 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue,
                                                       Bao'an District, Shenzhen, Guangdong, China
 Testing Location/ Procedure ........... : Full application of Harmonised standards ■
                                                       Partial application of Harmonised standards □
                                                       Other standard testing method □
 Applicant’s Name .......................... : AtGames Digital Media Inc.

 Address ........................................... : 2228 E Maple Ave, El Segundo, CA 90245, USA

 Test Specification

 Standard .......................................... : FCC CFR 47 PART 15 C(15.249)

 Test Report Form No. ................... : LCSEMC-1.0

 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd.

 Master TRF ..................................... : Dated 2011-03
 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
 This publication may be reproduced in whole or in part for non-commercial purposes as long as the
 Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the
 material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not
 assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
 placement and context.
 EUT Description. ........................... : Bandai Namco Arcade Blast

 Trade Mark ...................................... : N/A

 Model/ Type reference .................... : WD3305

 Ratings ............................................ : DC 5V by USB Port

 Result ............................................ : Positive

             Compiled by:                                    Supervised by:                               Approved by:




     Ace Chai / Administrators                     Aking Jin / Technique principal                   Gavin Liang/ Manager




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 2 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AMTQMK3BLTV2            Report No.: LCS190625047AEA


                                                          FCC -- TEST REPORT

                                                                                                  July 11, 2019
       Test Report No. :                           LCS190625047AEA
                                                                                                  Date of issue


   Type / Model...........................          : WD3305

   EUT.........................................     : Bandai Namco Arcade Blast


   Applicant...............................         :   AtGames Digital Media Inc.
   Address..................................        :   2228 E Maple Ave, El Segundo, CA 90245, USA
   Telephone...............................         :   /
   Fax..........................................    :   /


   Manufacturer........................             :   AtGames Digital Media Inc.
   Address...................................       :   2228 E Maple Ave, El Segundo, CA 90245, USA
   Telephone...............................         :   /
   Fax..........................................    :   /


   Factory...................................       : /
   Address...................................       : /

   Telephone...............................         : /
   Fax..........................................    : /




                              Test Result                                                        Positive
   The test report merely corresponds to the test sample.
   It is not permitted to copy extracts of these test result without the written permission of the test laboratory.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 3 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA

                                                         Revision History

          Revision                         Issue Date                          Revisions                        Revised By
            000                           July 11, 2019                       Initial Issue                     Gavin Liang




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 4 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                              FCC ID: 2AMTQMK3BLTV2                        Report No.: LCS190625047AEA


                                                                 TABLE OF CONTENTS
1. GENERAL INFORMATION ................................................................................................................................... 6
   1.1. DESCRIPTION OF DEVICE (EUT) ........................................................................................................................ 6
   1.2. HOST SYSTEM CONFIGURATION LIST AND DETAILS .......................................................................................... 6
   1.3. EXTERNAL I/O CABLE ......................................................................................................................................... 6
   1.4. DESCRIPTION OF TEST FACILITY ........................................................................................................................ 7
   1.5. STATEMENT OF THE MEASUREMENT UNCERTAINTY .......................................................................................... 7
   1.6. MEASUREMENT UNCERTAINTY ........................................................................................................................... 7
   1.7. DESCRIPTION OF TEST MODES .......................................................................................................................... 8
2. TEST METHODOLOGY ......................................................................................................................................... 9
   2.1. EUT CONFIGURATION ........................................................................................................................................ 9
   2.2. EUT EXERCISE ................................................................................................................................................... 9
   2.3. GENERAL TEST PROCEDURES ........................................................................................................................... 9
3. SYSTEM TEST CONFIGURATION .................................................................................................................... 10
   3.1. JUSTIFICATION .................................................................................................................................................. 10
   3.2. EUT EXERCISE SOFTWARE .............................................................................................................................. 10
   3.3. SPECIAL ACCESSORIES .................................................................................................................................... 10
   3.4. BLOCK DIAGRAM/SCHEMATICS......................................................................................................................... 10
   3.5. EQUIPMENT MODIFICATIONS ............................................................................................................................ 10
   3.6. TEST SETUP ...................................................................................................................................................... 10
4. SUMMARY OF TEST RESULTS ........................................................................................................................ 11
5. TEST RESULT ....................................................................................................................................................... 12
   5.1. RADIATED EMISSION MEASUREMENT ............................................................................................................... 12
   5.2. 20 DB BANDWIDTH MEASUREMENT ................................................................................................................. 21
   5.3. AC POWER LINE CONDUCTED EMISSIONS ........................................................................................................ 23
   5.4. RESULTS FOR BAND EDGE TESTING ................................................................................................................ 25
   5.5. ANTENNA REQUIREMENTS ................................................................................................................................ 31
6. LIST OF MEASURING EQUIPMENTS .............................................................................................................. 32
7. TEST SETUP PHOTOGRAPHS OF EUT .......................................................................................................... 33
8. EXTERIOR PHOTOGRAPHS OF THE EUT ..................................................................................................... 33
9. INTERIOR PHOTOGRAPHS OF THE EUT ...................................................................................................... 33




      This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                     Page 5 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2               Report No.: LCS190625047AEA


1. GENERAL INFORMATION
  1.1. Description of Device (EUT)
        EUT                             : Bandai Namco Arcade Blast
        Test Model                      : WD3305
                                          WD3305Q,WD3305E,WD3305S,WD3306, WD3306W, WD3306Q,
                                          WD3306E, WD3306S, WD3307, WD3307Q, WD3307E, WD3307S,
                                          WD3308, WD3308Q, WD3308E, WD3308S, WD3309, WD3309Q,
                                          WD3309E, WD3309S, WD3310, WD3310Q, WD3310E, WD3310S,
                                          WD3311, WD3311Q, WD3311E, WD3311S,WD3312,
        Additional Model                : WD3312Q,WD3312E, WD3312S, WD3313, WD3313Q, WD3313E,
                                          WD3313S, WD3314,WD3314Q,WD3314E,WD3314S, WD3315,
                                          WD3315Q, WD3315E, WD3315S, WD3316, WD3316Q, WD3316E,
                                          WD3316S, WD3317,WD3317Q,WD3317E,WD3317S, WD3318,
                                          WD3318Q, WD3318E, WD3318S, WD3319, WD3319Q, WD3319E,
                                          WD3319S, WD3320,WD3320Q,WD3320E,WD3320S.
                                          PCB board, structure and internal of these model(s) are the same,
        Model Declaration               :
                                          So no additional models were tested.
        Power Supply                    : DC 5V by USB Port
        Hardware Version                : WD3305-V2.0
        Software Version                : 153F-V4.0.HEX
        2.4G Function                   :
                                          2407- 2469MHz
                                          (2407 MHz, 2413 MHz, 2420 MHz, 2426 MHz, 2431 MHz, 2436 MHz,
        Frequency Range                 :
                                          2439 MHz ,2442 MHz, 2447 MHz, 2449 MHz, 2452 MHz, 2454 MHz,
                                          2459 MHz, 2462 MHz, 2467 MHz, 2469 MHz)
        Channel Number                  : 16
        Modulation Type                 : GFSK
        Antenna Description             : PCB Antenna, 5.5dBi(Max.)

  1.2. Host System Configuration List and Details

                                                                                               Serial
              Manufacturer                  Description                 Model                                   Certificate
                                                                                              Number
                  Lenovo                    Adapter for
                                                                 ADLX65YCC3A                       --              VOC
                                            Notebook
                  Lenovo                    Notebook                 TP00094A                      --            FCC ID


  1.3. External I/O Cable

                I/O Port Description                          Quantity                               Cable
                  Micro USB Port                                1                               0.3m, unshielded
                     HDMI Port                                  1                                      --




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 6 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA
  1.4. Description of Test Facility
    FCC Registration Number is 254912.
    Industry Canada Registration Number is 9642A-1.
    EMSD Registration Number is ARCB0108.
    UL Registration Number is 100571-492.
    TUV SUD Registration Number is SCN1081.
    TUV RH Registration Number is UA 50296516-001.
    NVLAP Accreditation Code is 600167-0.
    FCC Designation Number is CN5024.
    CAB identifier: CN0071.

    The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.4:2014 and CISPR
    16-1-4:2010 SVSWR requirement for radiated emission above 1GHz.

  1.5. Statement of the Measurement Uncertainty
    The data and results referenced in this document are true and accurate. The reader is cautioned that
    there may be errors within the calibration limits of the equipment and facilities. The measurement
    uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 – 4
    “Specification for radio disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty
    in EMC Measurements” and is documented in the LCS quality system acc. To DIN EN ISO/IEC 17025.
    Furthermore, component and process variability of devices similar to that tested may result in additional
    deviation. The manufacturer has the sole responsibility of continued compliance of the device.

  1.6. Measurement Uncertainty
                    Test Item                       Frequency Range                       Uncertainty                Note
                                                      9KHz~30MHz                           ±3.10dB                    (1)
                                                    30MHz~200MHz                           ±2.96dB                    (1)
            Radiation Uncertainty            :     200MHz~1000MHz                          ±3.10dB                    (1)
                                                     1GHz~26.5GHz                          ±3.80dB                    (1)
                                                    26.5GHz~40GHz                          ±3.90dB                    (1)
           Conduction Uncertainty :                  150kHz~30MHz                          ±1.63dB                    (1)
             Power disturbance    :                 30MHz~300MHz                           ±1.60dB                    (1)

    (1). This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
    level using a coverage factor of k=2.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 7 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA


  1.7. Description of Test Modes
    The EUT has been tested under operating condition.
    This test was performed with EUT in X, Y, Z position and the worst case was found when EUT in X
    position.
    Worst-case mode and channel used for 9 KHz-1000 MHz radiated emissions was the mode and channel
    with the highest output power, that was determined to be 2.4GHz mode(Low Channel).
    All test modes were tested, only the result of the worst case was recorded in the report.

    Channel List & Frequency

                                  Channel                                            Frequency(MHz)
                                     1                                                    2407
                                     8                                                    2442
                                    16                                                    2469

                           Mode of Operations                            Transmitting Frequency
                                                                                 (MHz)
                                                                                  2407
                                    GFSK                                          2442
                                                                                  2469
                                                     For Radiated Emission
                                 Test Mode                                     TX Mode




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 8 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA


2. TEST METHODOLOGY
    All measurements contained in this report were conducted with ANSI C63.10-2013, American National
    Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.
    The radiated testing was performed at an antenna-to-EUT distance of 3 meters. All radiated and
    conducted emissions measurement was performed at Shenzhen LCS Compliance Testing Laboratory Ltd.

  2.1. EUT Configuration
    The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions
    requirement and operating in a manner that intends to maximize its emission characteristics in a
    continuous normal application.

  2.2. EUT Exercise
    The EUT was operated in the engineering mode to fix the TX frequency that was for the purpose of the
    measurements.
    According to its specifications, the EUT must comply with the requirements of the Section 15.203, 15.205,
    15.207, 15.209 and 15.249 under the FCC Rules Part 15 Subpart C.

  2.3. General Test Procedures

   2.3.1 Conducted Emissions

    The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the requirements in
    Section 6.2.1 of ANSI C63.10-2013 Conducted emissions from the EUT measured in the frequency range
    between 0.15 MHz and 30MHz using Quasi-peak and average detector modes.

   2.3.2 Radiated Emissions

    The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall rotate 360
    degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving
    antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to be
    maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to find
    out the maximum emissions, exploratory radiated emission measurements were made according to the
    requirements in Section 6.3 of ANSI C63.10-2013




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 9 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA


3. SYSTEM TEST CONFIGURATION
  3.1. Justification
    The system was configured for testing in a continuous transmits condition.

  3.2. EUT Exercise Software
      N/A

  3.3. Special Accessories
    N/A

  3.4. Block Diagram/Schematics
    Please refer to the related document

  3.5. Equipment Modifications
    Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT.

  3.6. Test Setup
    Please refer to the test setup photo.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 10 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA



4. SUMMARY OF TEST RESULTS

                                       Applied Standard: FCC Part 15 Subpart C
                 FCC Rules                                    Description of Test                                 Result
         §15.205(a), §15.209(a),
                                                    Radiated Emissions Measurement                             Compliant
         §15.249(a), §15.249(c)
                 §15.215(c)                           20 dB Bandwidth Measurement                              Compliant
           §15.205, §15.249(d)                         Emissions at Restricted Band                            Compliant
                 §15.207(a)                           AC Line Conducted Emissions                              Compliant
                   §15.203                                 Antenna Requirements                                Compliant




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 11 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                       FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA



5. TEST RESULT
  5.1. Radiated Emission Measurement
   5.1.1. Standard Applicable

    1. According to §15.249 (d): Emissions radiated outside of the specified frequency bands, except for
       harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the general
       radiated emission limits in §15.209, whichever is the lesser attenuation.

         Frequencies(MHz)             Field Strength(microvolts/meter)            Measurement Distance(meters)
             0.009~0.490                          2400/F(KHz)                                       300
             0.490~1.705                         24000/F(KHz)                                       30
              1.705~30.0                                30                                          30
                 30~88                                 100                                           3
                88~216                                 150                                           3
               216~960                                 200                                           3
              Above 960                                500                                           3

    2. According to §15.249 (a): Except as provided in paragraph (b) of this section, the field strength of
       emissions from intentional radiators operated within these frequency bands shall comply with the
       following:

          Fundamental                Field strength of fundamental                   Field strength of harmonics
            frequency             millivolts/meter            dBuV/m            microvolts/meter             dBuV/m
          902-928 MHz                     50                     94                    500                     54
        2400-2483.5 MHz                   50                     94                    500                     54
         5725-5875 MHz                    50                     94                    500                     54
         24.0-24.25 GHz                  250                    108                    2500                    68

    As shown in §15.35(b), for frequencies above 1000 MHz, the field strength limits in paragraphs (a) and (b)
    of this section are based on average limits. However, the peak field strength of any emission shall not
    exceed the maximum permitted average limits specified above by more than 20 dB under any condition of
    modulation. For point-to-point operation under paragraph (b) of this section, the peak field strength shall
    not exceed 2500 millivolts/meter at 3 meters along the antenna azimuth
   5.1.2. Measuring Instruments and Setting

    Please refer to section 5 of equipments list in this report. The following table is the setting of spectrum
    analyzer and receiver.
       Spectrum Parameter                                       Setting
       Attenuation                                              Auto
       Start Frequency                                          1000 MHz
       Stop Frequency                                           10th carrier harmonic
       RB / VB (Emission in restricted band)                    1MHz / 3MHz for Peak, 1 MHz / 10Hz for Average
       RB / VB (Emission in non-restricted band)                1MHz / 3MHz for Peak, 1 MHz / 10Hz for Average

       Receiver Parameter                                       Setting
       Attenuation                                              Auto
       Start ~ Stop Frequency                                   9kHz~150kHz / RB/VB 200Hz/1KHz for QP/Average
       Start ~ Stop Frequency                                   150kHz~30MHz / RB/VB 9kHz/30KHz for QP/Average
       Start ~ Stop Frequency                                   30MHz~1000MHz / RB/VB 120kHz/1MHz for QP

   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 12 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA


   5.1.3. Test Procedures

    1) Sequence of testing 9 kHz to 30 MHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or described by
    manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions.
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0°to 315°using 45°steps.
    --- The antenna height is 0.8 meter.
    --- At each turntable position the analyzer sweeps with peak detection to find the maximum of all
    emissions

    Final measurement:
    --- Identified emissions during the premeasurement the software maximizes by rotating the turntable
    position (0°to 360°) and by rotating the elevation axes (0°to 360°).
    --- The final measurement will be done in the position (turntable and elevation) causing the highest
    emissions with QPK detector.
    --- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin to
    the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be
    stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 13 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA


    2) Sequence of testing 30 MHz to 1 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or described by
    manufacturer.
    --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground plane.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0°to 315°using 45°steps.
    --- The antenna is polarized vertical and horizontal.
    --- The antenna height changes from 1 to 3 meter.
    --- At each turntable position, antenna polarization and height the analyzer sweeps three times in peak to
    find the maximum of all emissions.

    Final measurement:
    --- The final measurement will be performed with minimum the six highest peaks.
    --- According to the maximum antenna and turntable positions of premeasurement the software maximize
    the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4 meter.
    --- The final measurement will be done with QP detector with an EMI receiver.
    --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization, turntable
    angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the
    premeasurement with marked maximum final measurements and the limit will be stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 14 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA


    3) Sequence of testing 1 GHz to 18 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or described by
    manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0°to 315°using 45°steps.
    --- The antenna is polarized vertical and horizontal.
    --- The antenna height scan range is 1 meter to 2.5 meter.
    --- At each turntable position and antenna polarization the analyzer sweeps with peak detection to find the
    maximum of all emissions.

    Final measurement:
    --- The final measurement will be performed with minimum the six highest peaks.
    --- According to the maximum antenna and turntable positions of premeasurement the software maximize
    the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4 meter. This
    procedure is repeated for both antenna polarizations.
    --- The final measurement will be done in the position (turntable, EUT-table and antenna polarization)
    causing the highest emissions with Peak and Average detector.
    --- The final levels, frequency, measuring time, bandwidth, turntable position, EUT-table position, antenna
    polarization, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of
    the premeasurement with marked maximum final measurements and the limit will be stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 15 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA


    4) Sequence of testing above 18 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or described by
    manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 1 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The antenna is moved spherical over the EUT in different polarizations of the antenna.

    Final measurement:
    --- The final measurement will be performed at the position and antenna orientation for all detected
    emissions that were found during the premeasurements with Peak and Average detector.
    --- The final levels, frequency, measuring time, bandwidth, correction factor, margin to the limit and limit
    will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 16 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA


   5.1.4. Test Setup Layout




    Above 18 GHz shall be extrapolated to the specified distance using an extrapolation factor of 20
    dB/decade form 3m to 1m.
    Distance extrapolation factor = 20 log (specific distanc [3m] / test distance [1.5m]) (dB);
    Limit line = specific limits (dBuV) + distance extrapolation factor [6 dB].




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 17 of 33


SHENZHEN LCS COMPLANCE TESTING LABORATORY LTD                        PCC TD: 2AMTOMK3BLTV2           Report No.;LCS190625047A BA


   5.1.5. EUT Operation during Test

    The EUT was programmed to be in continuously transmitting mode.


   5.1.6. Results of Radiated Emissions (9 KHz~8OMHz)


               Temperature                         28.7°C                  Humidity                         54.1%
             Test Engineer                       David Luo               Configurations                Low Channel

                Freq.                   Level                Over Limit             Over Limit                  n           k
                (MHz)                  (dBuy)                   (d8)                   (d8)                         emarl
                   —                         —                   —                       —                      See Note

    Note:
    The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible
    value has no need to be reported.
    Distance extrapolation factor = 40 log (specific distance / test distance) (dB);
    Limit line = specific limits (dBuV) + distance extrapolation factor.

   5.1.7. Results of Radiated Emissions (3OMHz~1GHz)

               Temperature                        23.7°C                  Humidity                         54.1%
             Test Engineer                       David Luo             Configurations                 Low Channel

    Low Channel
    Horizontal:
            so Level (dBuvimy


        co.0
                                                                                                            rcclcuassn

        s0.0 fi5


        20.0


             ©30              5o                    T00          200                                 500                        1000
                                                        Frequency (iHz)
   Env. /tns:                               as.7°C/sa .18
   por:                                     nortzomman
                       Freq    Reading           Cabtos      Antfac       Messured           Limit     Over           Remark
                       wz           asuw            as       an/m         dBuy/m         aBuy/m            as
                ie2.5e              2e.e7         o.es        5.97         s7.er         aslse         Csl83            ocp
                208.se             27. 69         o.se       10.94         s9.39          as.se        —a.i1            or
                zes.er             20.10          1.00       i2.2s         ar.4as        as.00         —a.57            or
                sor.as             20.51          i03        13.09         ar.es         ae.o0         —3.37            or
                se0.as              2s.ve         nae        rs.a3         ar.g9         as.00         —a.61            or
                                                  1.           —              —
          1. A1l readings are Quasi—peck velues.
    2. Messured= Reading + Antenna Factor + Cable hess
    3. The emission that are 20db below the official limit are not reported


   This report shall not be reproduced except infull, withowthe written approval ofShenzhen LCS Compliance Testing Laboratory Ltd
                                                              Page 18 of33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA
    Vertical:




    Note:
    1). Pre-scan all modes and recorded the worst case results in this report (Low Channel). Emission level
      (dBuV/m) = 20 log Emission level (uV/m).
    2). Corrected Reading: Antenna Factor + Cable Loss + Read Level = Level.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 19 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA


   5.1.8. Results of Radiated Emissions (Above 1GHz)

                                       Field Strength Of Fundamental
Frequency        Pol.      Measure Result    Measure Result    Peak Limit                            AVG Limit             Result
  (MHz)                     (PK, dBuV/m)     (AVG, dBuV/m)      (dBuV/m)                             (dBuV/m)
   2407            H              87.65                     83.14                    114                  94               Pass
   2407            V              87.57                     82.61                    114                  94               Pass

            Reading        Ant.          Pre.        Cab.
 Freq.                                                           Measured          Limit       Margin
             Level        Fac.          Fac.         Loss                                                  Remark            Pol.
 MHz                                                              dBuV/m          dBuV/m        dB
             dBuV         dB/m           dB           dB
4814.26      54.82        33.06         35.04        3.94           56.78          74.00       -17.22       Peak         Horizontal
4814.18      42.25        33.06         35.04        3.94           44.21          54.00        -9.79      Average       Horizontal
4814.18      56.26        33.16         35.06        3.96           58.32          74.00       -15.68       Peak          Vertical
4814.11      39.23        33.16         35.06        3.96           41.29          54.00       -12.71      Average        Vertical

                                          Field Strength Of Fundamental
    Frequency             Pol.      Measure Result     Measure Result                     Peak Limit           AVG Limit        Result
      (MHz)                          (PK, dBuV/m)      (AVG, dBuV/m)                      (dBuV/m)             (dBuV/m)
          2442              H              87.98                      83.84                   114                  94            Pass
          2442              V              87.59                      83.52                   114                  94            Pass

            Reading        Ant.          Pre.        Cab.
 Freq.                                                           Measured          Limit       Margin
             Level        Fac.           Fac.        Loss                                                  Remark            Pol.
 MHz                                                              dBuV/m          dBuV/m        dB
             dBuV         dB/m            dB          dB
4884.27      58.77        33.16         35.15        3.96           60.74          74.00       -13.26       Peak         Horizontal
4884.06      44.67        33.16         35.15        3.96           46.64          54.00        -7.36      Average       Horizontal
4884.07      54.50        33.26         35.17        3.98           56.57          74.00       -17.43       Peak          Vertical
4884.14      40.19        33.26         35.17        3.98           42.26          54.00       -11.74      Average        Vertical

                                       Field Strength Of Fundamental
Frequency        Pol.      Measure Result    Measure Result    Peak Limit                            AVG Limit             Result
  (MHz)                     (PK, dBuV/m)      (AVG, dBuV/m)     (dBuV/m)                             (dBuV/m)
   2469            H              87.61                     82.45                    114                  94               Pass
   2469            V              87.36                     81.71                    114                  94               Pass

           Reading         Ant.          Pre.        Cab.
 Freq.                                                           Measured          Limit       Margin
            Level         Fac.           Fac.        Loss                                                  Remark            Pol.
 MHz                                                              dBuV/m          dBuV/m        dB
            dBuV          dB/m            dB          dB
4938.28     56.21         33.26         35.14        3.98           58.31          74.00       -15.69       Peak         Horizontal
4938.13     43.30         33.26         35.14        3.98           45.40          54.00        -8.60      Average       Horizontal
4938.29     54.29         33.36         35.16        4.00           56.49          74.00       -17.51       Peak          Vertical
4938.26     40.87         33.36         35.16        4.00           43.07          54.00       -10.93      Average        Vertical

    Notes:
    1. Measuring frequencies from 9k~10th harmonic (ex. 26GHz), No emission found between lowest
       internal used/generated frequency to 30MHz.
    2. Radiated emissions measured in frequency range from 9k~10th harmonic (ex. 26GHz) were made with
       an instrument using Peak detector mode.
    3. No emission was be recorded above 18GHz means the reading of emissions are attenuated more than
       20dB below the permissible limits or the field strength is too small to be measured.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 20 of 33


supnzvipn tes couptince resrino tasonaroey tTh        Feoio »MTOMGRINO          Reeaite: Lesioeersonsen
   5.2. 20 dB Bandwidih Measurement
     5211. Standard Appleatle
According to $ 15215(e)Intentionalradiators operating under the atemative provisions to the general
emission imis, must be desiqned to ensure tha the 20 dB bandlwicth ofthe emission, o whatever bandcth
may ohervise be specifed in the speaifrule section under whichthe eauipment operates,If a frequency
stabiltyis not specified in the regulatons, tis recommended that the fundamental emission be kegt within at
Teastthe central 80% of the permited bandin orderto minimize the possibliy of ou—0fband operation:
In some cases, the x dBbandwicth® is required. which is detined as the reuency range between two polnts,
one atthe lowestfrequency below and one a the highest reauency above the carterfrequency, at whichthe
masimum powerlevel fthe transmited emission is attenvated x c3 below the maximum in band powerlevel
of the modiiated signal, where the ho poinare on the outskirs ofthe n—band emission
   5.2.2. Block Diagram of Test Setup
                      M ——s
   5.2.3. Test Procedure
Use thefolowing spectum analyzer settings
Span = 3Mz
RGW 0Kz
vew 100 kz
Sweep = auto
Detector function = peak
Trace =max hold
The EUT should be transmiting atits maximum dat rate. Alow the tmoe to stablize. Use the
marteto—peak functionto setthe marker to the peak ofthe emission. Use the marker—delta function to
measure 20 d down one side ofthe emission, Reset the marker—deltafunction, and move the markerto the
other se ofthe emssion,untit s (as cose as possible to} even with the reference marker evel. The
marier—dehareacing atthis point i the 20 0B bandiicth ofthe emiesion,If ths value varieswith ciferent
mordes of operation (29., data rate, modulaton format, to}, repeatthistest or each variaton. The limiis
specifed in one of the subparagrachs of this Section. Submt this plot(s)
   524. Test Resul
           Temperaure                 zse                   Tumaiy                  same
           Test Engnser              Davatze              Uonqurmmors             eceressm
     TestMode          Channel          Fr?mezr;cv     2008 Bandwth (Mriz)        Lims         Verdet
                         tw               207                  zs
                                                               Tok              Nonspesi |     pass
        arsk            Made              2aae
                         Figh             2ace                 Tsm
    Remarie
    1. Test resulls including cable loss;
    2. please refer tfollowing plots;
    The roonsialinib apreiiet aneynulith wraenagpreral e(Braies Bs Garylover Iave laverven n
                                        Poge2ters2


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA


                                                        20dB Bandwidth




               Low Channel- 2407MHz




             Middle Channel- 2442MHz




               High Channel- 2469MHz




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 22 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA


  5.3. AC Power line conducted emissions
   5.3.1 Standard Applicable

    According to §15.207 (a): For an intentional radiator which is designed to be connected to the public utility
    (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any
    frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts (The limit
    decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz). The limits at
    specific frequency range are listed as follows:

                        Frequency Range                                          Limits (dBμV)
                              (MHz)                                         Quasi-peak                         Average
                           0.15 to 0.50                                      66 to 56                          56 to 46
                             0.50 to 5                                          56                                46
                              5 to 30                                           60                                50

              * Decreasing linearly with the logarithm of the frequency

   5.3.2 Block Diagram of Test Setup


                                                              Vert. reference
                                                                 plane

                                                                                                        EMI receiver

                                                                        EUT
                                                    PC




                           LISN                                              Reference ground plane




   5.3.3 Test Results

    PASS.
    The test data please refer to following page.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 23 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA

AC Conducted Emission of charge from PC mode @ AC 120V/60Hz @ GFSK (worst case)
Line




Neutral




   ***Note: Pre-scan all modes and recorded the worst case results in this report.
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 24 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                      FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA


5.4. Results for Band edge Testing

5.4.1 Standard Applicable
According to FCC §15.249 (d): Emissions radiated outside of the specified frequency bands, except for
harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the general radiated
emission limits in §15.209, whichever is the lesser attenuation.
According to RSS-210 B.10 (b): Emissions radiated outside of the specified frequency bands, except for
harmonic emissions, shall be attenuated by at least 50 dB below the level of the fundamental emissions or to
the general field strength limits listed in RSS-Gen, whichever is less stringent.

5.4.2. Test Setup Layout




5.4.3. Measuring Instruments and Setting

   Please refer to equipment list in this report. The following table is the setting of Spectrum Analyzer.

5.4.4. Test Procedures

    3) Sequence of testing 1 GHz to 18 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or described by
    manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.




    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 25 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA
    Premeasurement:
    --- The turntable rotates from 0°to 315°using 45°steps.
    --- The antenna is polarized vertical and horizontal.
    --- The antenna height scan range is 1 meter to 2.5 meter.
    --- At each turntable position and antenna polarization the analyzer sweeps with peak detection to find the
    maximum of all emissions.

    Final measurement:
    --- The final measurement will be performed with minimum the six highest peaks.
    --- According to the maximum antenna and turntable positions of premeasurement the software maximize
    the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4 meter. This
    procedure is repeated for both antenna polarizations.
    --- The final measurement will be done in the position (turntable, EUT-table and antenna polarization)
    causing the highest emissions with Peak and Average detector.
    --- The final levels, frequency, measuring time, bandwidth, turntable position, EUT-table position, antenna
    polarization, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of
    the premeasurement with marked maximum final measurements and the limit will be stored.

 5.4.5. Measuring Instruments and Setting

              Temperature                       24.6℃                         Humidity                        51.6%
             Test Engineer                    David Luo

PASS

Remark:
1. The other emission levels were very low against the limit.
2. The average measurement was not performed when the peak measured data under the limit of average
   detection.
3. Detector AV is setting spectrum/receiver. RBW=1MHz/VBW=330Hz/Sweep time=Auto/Detector=Peak;
4. Please refer to following test plots;




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 26 of 33


                                                                                         ree pare15.240..910
     ors)
                                                                                                             a

     s5.0!
                                                                                     i          1
     s25)


             z300 2310     2320                     z350                                                              Zizo

  pot:                                  xontzowran
                   Freq       Resding      Cabhos     Antfee          Messured      Limit       Over                 Remerk
                    rase        amuw         as       an/m            asuy/m      dsuw/m            ab
        1.     2300.00          a.e7        a.ee      so.3s             a1.ee      74.00       —32.12                 Feak
        2      2390.00          9. o2       a.08      si.ie             aa.2e     74.00         —30.74                reak
        3      2a00.00         r2.os        a.0s      si.24             as.9s     7a.00         —27.52                reak
        a       rmaov.ge       si.ss        a.0e      a1.27             as.es     110.00        —28.12                reak
  Wote: 1. All readings are Quasi~peak velues.
  2. Measured= Reading + Antenna Factor + Cable Loss
  3. The emission thet are 20db below the efficial limit are not reported


      130
              Level «dBuvim



     or.s                                                                                    ree panr—5210.400—
                                                                                                                 a
     65.0




     325                                                                                 :          :




              2300 2310    2320                     2350                                                                2420
                                                                 ney (hHz)

 por:                                   nontzonmar
                  Freq        Reading      CabLos     Antfac          Measured      Limit           Over             Remark
                   mite         dBuy         ap       ds/m            dBuy/m      dBuy/m                as

     10       ESb0.00          ~Cerer       stes      solse             CSi.es    52100         CeRel                 Average
     2        23 90 .00        —2.05        3.08      31.16             32.19     54.00         ~21.81                Average
     3        2a00.00          —o.0a        s10e      ail2za            33.46      54.00        —20.5%                averege
     a        rmaov.an         a1.90        R.sa      ailse             76.10     94.00         —17.90                averege
 Note: 1. All readings are Quesi—pesk velues.
 2. Messured= Reading + Antenna Factor + Cable Loss
 3. The emission that are 20db below the official limit are not reported



es reprarsamn mun reproumsew eacepinpaay manoom ue         ==—       pnaryy ansnunence vompmunce resung cxrsmawy on


                                                                                ree pAnt 15.240.(019




        2300 2310       2320                    2350
                                                  Frequency (Miiz)
 pot:                                   veaszcan
               Preq       Reading           Cabzes
                   nz           asuy
           2500.12              .77
           2350.00              9. 65
           2400.00             is.07
           eao7. 97—           57.30
 Note: 1. All resdings are Quasi~pesk velues.
 2. Measured= Resding + Antenns Factor + Cable Less
 3. the emission that are 20db below the officiel limit are not ceported
  . .oLevel (dBu


                                                                                 ree pdnt— 1523000
                                                                                            a




        ‘zz00 2310      2320

                                      venzzcas
              Freq       Reading          CabDes                Measured      Limit    Over     Remark
               wice            amuy          am                 amuy/m       dmuy/m     am
          2500.00               4s          5.22         —           si.e7    sa.00   —22.        Average
          2330.00               .87         3.08         .           se.37   sa.00    —21.        Average
          2400.00               l43         3.06         .           sa.79   sa.00    —19.        Average
          2a07.36               ces         2.94         .           so .    aa.00    —13.        Average
Note: 1. All resdings are Quasi—pesk velues.
2. Measured= Resding + Antenna Pactor + Cable Loss
3. The emission that are 20db below the official limit are not reported


      450Level (davim                                                                    bate: 2019.07.03


      onsl l                        1
                                    t

      es
                LA
                                    n\
                                         A\                                                             .
      s2s            m              f                                             |


             2i00      2405                                                                           2500
                                                       Frequency (iitz)
por                                      morzzouraz
                    Preq    Reading           CabLos   Antfac      Measured    Limit    Over      Remark
                     ns          apuy           am     an/m        daBuy/m    dbuy/m     ds
      1       Rass.ze           s0.04          S.ar     silas        sa.64    114.00   —29.38        Peak
      &        mass.so           aisis         3.23     ai.se        a5.90    74.00     —28.10      Reak
      3       2s00.00            ii.is         .36     ar.ss         46.10    74.00     —27.90      Reak
Note: 1. All resdings are Quasi—pesk values.
2. measured Reading + Antenna Factor + Cable Loss
3. The emission that are 208b below the official limit are not reported
                                                                                         Date: 2010.07.03
           aso Level ratuvim)


       or.s}—


       ss.o
                                                                                       ree 15249401

       a2s


             ©zice       2105                                                                        2500
                                                       Frequency (htz)
por:                                nontzowman
                 Freq       Resding Cabtos             Antfec     Messured     Linit    Over Remark
                  rue         apay       as            as/m       asuy/m      dsuy/m     as
      1       Ees.se         40.08      5.42           silas       Tavea      92100    ~19.58  Average
      20      zess.s0         —1.92     3.23           arlse       32.94      54.00    —21.06  Aaverage
      3       2so0.00        —1.54      .36            ar.so       39.41      54.00     —20.59 Aaverage
Note: 1. All resdings are Quasi—pesk velues.
2. Messuree Reading + Antenna Pactor + Cable Loss
3. The emission thet are 200b below the official limit aze not reported


 hireyors is en vereprvinnon excays ones mormno —          pniep ananren racu carmyniaice resung carerrmry can
                                               rugeer uies


         1z0 Leve! (atuvim)


       ansl l

                                                                                        ree 15.240.pr4
       e5.0                            t                —


       sasl—l———                 M                           !                                     —


              zaso      2165                                                                            2500
                                                     Frequency (Hz)
por:                                   veanrcan
                  Preq        Reading      CabLos   Antfec       Measured      Limit    Over      Remark
                     ns         amey         am     an/m         aBuy/m      dmuy/m      am
    10      PeRocan            salsy       509      ~a1—am        Smam      Crikcna    C—rmcRa         vree
   &0       ese3.s0            i1.42       s.ee     or.s3         a6.18      74.00      —27.02         Peak
   3        aso0.00            i1.7a       s.3s      s1.s9        a6.69      74.00     —27.31          Peak
Wote: 1. All resdings are Quasi~pesk velues.
2. measured= mesding + Antenna Factor + Cable toss
3. the emission thet are 20db below the officiel limit are not reported


   130 Level (dBu¥im)


   a7s
                                  4

   s50                                                                                            —
                                                                                       ree is2404a1

   s2s


           2is0        2aes                                                                            2500
                                                    Frequency (MHz)
por:                                   vearzcan
                     Freq     Resding      CabLos   Antfac       Measured      Limit    Over     Remark
                     wine       asuv         as     aB/m         abu¥/m     abev/m       as
   1          Eie9.0s          45.50        5iz      s1.4e        a0.40     $4.00      —13.60      Average
   &           mses.s0         —al47        a.2a    si.so         33.29     54.00       —20.71     Aaverage
   3          2s00.00          —1.s0        3.36     s1.5>        33.45     54.00       —20.55     Aaverage
Note: 1. All readings are Quasi—pesk values.
2. Measured= Reeding + Antenna Factor + Cable Loss
3. the emission that are 20db below the official limit are not reported


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA
  5.5. Antenna Requirements
   5.5.1 Standard Applicable

    According to antenna requirement of §15.203.

    An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
    responsible party shall be used with the device. The use of a permanently attached antenna or of an
    antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply
    with the provisions of this Section. The manufacturer may design the unit so that a broken antenna can be
    re-placed by the user, but the use of a standard antenna jack or electrical connector is prohibited. This
    requirement does not apply to carrier current devices or to devices operated under the provisions of
    Sections 15.211, 15.213, 15.217, 15.219, or 15.221. Further, this requirement does not apply to
    intentional radiators that must be professionally installed, such as perimeter protection systems and some
    field disturbance sensors, or to other intentional radiators which, in accordance with Section 15.31(d),
    must be measured at the installation site. However, the installer shall be responsible for ensuring that the
    proper antenna is employed so that the limits in this Part are not exceeded.

    And according to §15.247(4)(1), system operating in the 2400-2483.5MHz bands that are used
    exclusively for fixed, point-to-point operations may employ transmitting antennas with directional gain
    greater than 6dBi provided the maximum peak output power of the intentional radiator is reduced by 1 dB
    for every 3 dB that the directional gain of the antenna exceeds 6dBi.

   5.5.2 Antenna Connected Construction
   5.5.2.1. Standard Applicable

    According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
    furnished by the responsible party shall be used with the device.

   5.5.2.2. Antenna Connector Construction

    The directional gains of antenna used for transmitting is 5.5dBi, and the antenna is a PCB antenna
    connect to PCB board and no consideration of replacement. Please see EUT photo for details.

   5.5.2.3. Results: Compliance.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 31 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                        FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA



6. LIST OF MEASURING EQUIPMENTS
 Item                Equipment                   Manufacturer          Model No.             Serial No.           Cal Date       Due Date
  1            MXA Signal Analyzer                  Agilent             N9020A             MY49100060           2018-11-15      2019-11-14
  2              DC Power Supply                    Agilent              E3642A                 N/A             2018-11-15      2019-11-14
              Temperature & Humidity            GUANGZHOU
  3                                                                     GDS-100                70932            2018-10-10      2019-10-09
                    Chamber                       GOGNWEN
  4             EMI Test Software                  AUDIX                   E3                     /                 N/A             N/A
                                                     SIDT
  5         3m Semi Anechoic Chamber                                    SAC-3M              03CH03-HY           2019-06-12      2020-06-11
                                                 FRANKONIA
  6             Positioning Controller                MF                MF-7082                   /             2019-06-12      2020-06-11
                                                SCHWARZBEC
  7             Active Loop Antenna                                   FMZB 1519B               00005            2018-07-26      2019-07-25
                                                       K
                                                SCHWARZBEC
  8                By-log Antenna                                      VULB9163               9163-470          2018-07-26      2019-07-25
                                                       K
                                                SCHWARZBEC
  9                 Horn Antenna                                      BBHA 9120D            9120D-1925          2019-07-01      2020-06-30
                                                       K
                                                SCHWARZBEC
 10           Broadband Horn Antenna                                   BBHA 9170                791             2018-09-20      2019-09-19
                                                       K
                                                SCHWARZBEC
 11            Broadband Preamplifier                                  BBV 9719               9719-025          2018-09-20      2019-09-19
                                                       K
 12              EMI Test Receiver                   R&S                  ESR 7                101181           2019-06-12      2020-06-11
 13        RS SPECTRUM ANALYZER                       R&S                FSP40                 100503           2018-11-15      2019-11-14
 14            Broadband Preamplifier                   /             BP-01M18G               P190501           2019-07-01      2020-06-30
 15                RF Cable-R03m                    Jye Bao             RG142                  CB021            2019-06-12      2020-06-11
                                                                      SUCOFLEX
 16               RF Cable-HIGH                    SUHNER                                   03CH03-HY           2019-06-12      2020-06-11
                                                                         106
 17              EMI Test Receiver                    R&S                ESPI                  101840           2019-06-11      2020-06-10
 18                Artificial Mains               R&S         ENV216          101288      2019-06-12 2020-06-11
                                             SCHWARZBEC
  19             10dB Attenuator                            MTS-IMP-136   261115-001-0032 2019-06-11 2020-06-10
                                                   K
 Note: All equipment is calibrated through CHINA CEPREI LABORATORY and GUANGZHOU LISAI CALIBRATION AND TEST
 CO., LTD.




      This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                    Page 32 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                     FCC ID: 2AMTQMK3BLTV2              Report No.: LCS190625047AEA



7. TEST SETUP PHOTOGRAPHS OF EUT
    Please refer to separated files for Test Setup Photos of the EUT.


8. EXTERIOR PHOTOGRAPHS OF THE EUT
    Please refer to separated files for External Photos of the EUT.


9. INTERIOR PHOTOGRAPHS OF THE EUT
    Please refer to separated files for Internal Photos of the EUT.




                            ----------------THE END OF REPORT---------------




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 33 of 33



Document Created: 2019-07-30 08:30:41
Document Modified: 2019-07-30 08:30:41