RF Exposure Info

FCC ID: 2AMRO-HLCRIO161

RF Exposure Info

Download: PDF
FCCID_4390835

                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch




                                                                    Report No.: SZEM190501435002
                                                                    Page:        1 of 8

COVER PAGE

                       Human Exposure Report
Application No.:           SZEM1905014350AT
Applicant:                 iOttie, Inc
Address of Applicant:      20W, 37th Street, 6th FL. New York, NY 10018 United States
Manufacturer:              iOttie, Inc
Address of Manufacturer:   20W, 37th Street, 6th FL. New York, NY 10018 United States
Factory:                   Shenzhen ICHECKEY Technology Co., Ltd
Address of Factory:        B302, Building 4, Tianyanxuan, No.1, Lane 14, Bantian East Village, Bantian
                           Street, Longgang District, Shenzhen 518000 ShenzhenshiGuangdongsheng
Equipment Under Test (EUT):
EUT Name:                  Auto Sense Wireless
Model No.:                 HLCRIO161, HLCRIO162, HLCRIO163 ♣
♣                          Please refer to section 2.1 of this report which indicates which model was
                           actually tested and which were electrically identical.
Trade Mark:                iOttie
FCC ID:                    2AMRO-HLCRIO161
Standards:                 47 CFR PART 1, SUBPART I, SECTION 1.1310
Date of Receipt:               2019-05-24
Date of Test:                  2019-05-24 to 2019-06-20
Date of Issue:                 2019-06-20
Test Result :                    Pass*

* In the configuration tested, the EUT complied with the standards specified above.




            Keny Xu
      EMC Laboratory Manager


                                               SGS-CSTC Standards Technical Services Co., Ltd.
                                               Shenzhen Branch
                                                                                                    Report No.: SZEM190501435002
                                                                                                    Page:       2 of 8


1         Contents
                                                                                                                                                           Page
1      CONTENTS ................................................................................................................................................2

2      GENERAL INFORMATION ........................................................................................................................3
    2.1    DETAILS OF E.U.T. ...................................................................................................................................3
    2.2    DESCRIPTION OF SUPPORT UNITS .............................................................................................................3
    2.3    TEST LOCATION ........................................................................................................................................4
    2.4    TEST FACILITY ..........................................................................................................................................4
    2.5    DEVIATION FROM STANDARDS ...................................................................................................................5
    2.6    ABNORMALITIES FROM STANDARD CONDITIONS..........................................................................................5
3      EQUIPMENTS USED DURING TEST ........................................................................................................6

4      TEST RESULTS .........................................................................................................................................7
    4.1 RF EXPOSURE TEST .................................................................................................................................7
       4.1.1 E.U.T. Operation ............................................................................................................................7
       4.1.2 Measurement Data.........................................................................................................................8
5      PHOTOGRAPHS- TEST PHOTOS ............................................................................................................8


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                                Report No.: SZEM190501435002
                                                                Page:       3 of 8




2   General Information
2.1 Details of E.U.T.
    Power supply:             for Car charger,
                              Input: DC 12V-24V
                              Output: DC 5V/3A, DC 9V/2A, DC 12V/1.5A
                              for wireless charger,
                              Input: DC 5V/2A, DC 9V/1.67A
                              Output: 5W/7.5W/10W
                              USB Type A output: DC 5V, 2.4A
    Cable:                    DC cable: 120cm, unshielded
    Operation frequency:      118.59kHz to 151.12kHz
    Modulation type:          Load Modulation
    Antenna type:             Loop Antenna
    Remark:                   1) Tests were conducted in all three load modes and the worst case (10W)
                                  is reported only.
                              2) All tests were conducted in both supply mode of DC 12V and DC 24V
                                  and the worst case (DC 12V) were reported only.
    Remark:

    Model No.: HLCRIO161, HLCRIO162, HLCRIO163

    Only the model HLCRIO161 was tested, since the electrical circuit design, layout, components used,
    internal wiring and functions were identical for the above models, with only difference on accessories
    parts.



2.2 Description of Support Units
    Description                     Manufacturer             Model No.               Serial No.
    DC power                          ZHAOXIN                RXN-305D             REF. No.SEA2700
    iPhone 8                            Apple                  A1863              F4GVQ656JC6D
    SAMSUNG Galaxy S8                 SAMSUNG                SM-G9500               R28J9140LPB


                                             SGS—CSTC Standards Technical Services Co., Ltd.
                                             Shenzhen Branch

                                                                                                                       Report No.: SZEM190501435002
                                                                                                                       Page:                     4 of 8



2.3   Test Location
      All tests were performed at:
      SGS—CSTC Standards Technical Services Co., Ltd., Shenzhen Branch
      No. 1 Workshop, M—10, Middle Section, Science & Technology Park, Shenzhen, Guangdong, China.
      518057.
      Tel: +86 755 2601 2053       Fax: +86 755 2671 0594
          No tests were sub—contracted.

2.4   Test Facility
      The test facility is recognized, certified, or accredited by the following organizations:
      * CNAS (No. CNAS L2929)
      CNAS has accredited SGS—CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
      Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
      Laboratories (CNAS—CLO1 Accreditation Criteria for the Competence of Testing and Calibration
      Laboratories) for the competence in the field of testing.
      * AZ2LA (Certificate No. 3816.01)
      SGS—CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
      American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
      * VCCI
      The 3m Fully—anechoic chamber for above 1GHz, 10m Semi—anechoic chamber for below 1GHz,
      Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
      Conducted Interference Measurement of SGS—CSTC Standards Technical Services Co., Ltd. have
      been registered in accordance with the Regulations for Voluntary Control Measures with Registration
      No.: G—20026, R—14188, C—12383 and T—11153 respectively.
      * FCC —Designation Number: CN1178
      SGS—CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
      as an accredited testing laboratory.
      Designation Number: CN1178. Test Firm Registration Number: 406779.
      *     Innovation, Science and Economic Development Canada
      SGS—CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
      by ISED as an accredited testing laboratory.
      CAB identifier: CNOOO6.
      IC#: 46200.




                          Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                          overleaf, available on request or accessible at http://www.sgs.com/en/Terms—and—Conditions.aspx and, for electronic format documents,
                          subject to Terms and Conditions for Electronic Documents at http://www.sqs.com/en/Terms—and—Conditions/Terms—e—Document.aspx.
                          Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is
                          advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                          Client‘s instructions, if any. The Company‘s sole responsibility is to its Client and this document does not exonerate parties to a
                          transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                          except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
                          appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the
                          results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
                          Attention: To check the authenticity of testing /inspection report & certificate, please contact us at telephone: (86—755) 8307 1443,
                          or email: CN.Doccheck@sgs.com
                              No.1 Workshop, M—10, Middle Section, Science & Technology Park, Shenzhen, China 518057   t (86—755)26012053 f (86—755) 26710594    www.sgsgroup.com.cn
                              41B +«X— HKRMHEKM—10G—SJB                                                BB&@: 518057    t (86—755) 26012053 f (86—755) 26710594   sgs.china@sgs.com
                          T
                                                                                                                                          Member of the SGS Group (SGS SA)


                      SGS-CSTC Standards Technical Services Co., Ltd.
                      Shenzhen Branch
                                             Report No.: SZEM190501435002
                                             Page:       5 of 8




2.5 Deviation from Standards
    None.

2.6 Abnormalities from Standard Conditions
    None.


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                         Report No.: SZEM190501435002
                                                         Page:       6 of 8




3   Equipments Used during Test

    Item     Test Equipment        Manufacturer   Model No.   Inventory No. Cal. Due date

           Electric and Magnetic
     1                                Narda       EHP-50F       EMC092        2020-02-06
              Field Analyzer


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                   Report No.: SZEM190501435002
                                                                   Page:       7 of 8




4     Test Results
4.1 RF Exposure test
      Test Requirement:               47 CFR PART 1, Subpart I, Section 1.1310
      Measurement Distance:           15cm
      Limit:

    Frequency range Electric field strength Magnetic field strength Power density Averaging time
         (MHz)               (V/m)                  (A/m)             (mW/cm2)      (minutes)
                            (A) Limits for Occupational/Controlled Exposures
         0.3-3.0                614                       1.63               *(100)              6
          3.0-30               1842/f                    4.89/f             *(900/f2)            6
         30-300                 61.4                     0.163                   1.0             6
        300-1500                  /                         /                 f/300              6
      1500-100,000                /                         /                    5               6
                         (B) Limits for General Population/Uncontrolled Exposure
         0.3-1.34               614                       1.63               *(100)             30
         1.34-30                824/f                    2.19/f             *(180/f2)           30
         30-300                 27.5                     0.073                   0.2            30
        300-1500                  /                         /                f/1500             30
      1500-100,000                /                         /                    1.0            30
    F=frequency in MHz
    *=Plane-wave equivalent power density
    RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC rules.
    The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits for
    150kHz:614V/m,1.63A/m).
4.1.1 E.U.T. Operation

      Operating Environment:
      Temperature:     25.0 °C            Humidity:    51 % RH         Atmospheric Pressure: 1015 mbar

       EUT Operation:
      This device has been tested with mobile phone at zero charge, intermediate charge, and full charge.


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                 Report No.: SZEM190501435002
                                                                 Page:       8 of 8




4.1.2   Measurement Data


         Operation      Test                       Probe Measure Result(A/m)
                                      Test                                             50%Limit
         frequency    Distance
                                     Position   zero           intermediate   full
                                                charge            charge      charge    (A/m)
                           (cm)
                                      Side 1    0.0566            0.0472      0.0364    0.815
                                      Side 2    0.0108            0.0031      0.0942    0.815
         132.6 kHz         15         Side 3    0.0552            0.0478      0.0386    0.815
                                      Side 4    0.0891            0.0795      0.0697    0.815
                                       Top      0.0320            0.0214      0.0123    0.815

5       Photographs- Test photos




                                       - End of the Report -



Document Created: 2019-08-07 08:39:17
Document Modified: 2019-08-07 08:39:17

© 2024 FCC.report