User Manual

FCC ID: 2AMP5K60I

Users Manual

Download: PDF

K60i Wireless Communication System
             User Guide

           Release 1.2
           May 23, 2019


                             K60i User Guide




Kwikbit K60i User Guide
Confidential & Proprietary                     -2-


                                                                       K60i User Guide


Kwikbit is a trademark of Kwikbit Inc.

©2016-2019 Kwikbit Inc. All rights reserved.

This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.

You can determine whether your equipment is causing interference by turning it on and off. If the
interference stops, it was probably caused by the equipment. If the equipment causes interference
to radio or television equipment, try to correct the interference by using one or more of the
following measures:

    ▪   Reorient or relocate the receiving antenna.
    ▪   Increase separation between the equipment and receiver.
    ▪   Connect the equipment into an outlet on a circuit different from which the receiver is
        connected.
    ▪   Consult the dealer or an experienced radio/TV technician.

Any modifications to this product which are not authorized by Kwikbit Inc. could void your authority
to operate this equipment.



THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE
SUBJECT   TO   CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND
RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED
WITHOUT WARRANTY OF ANY KIND. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR
APPLICATION OF ANY PRODUCT.

NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE ARE
PROVIDED “AS IS” WITH ALL FAULTS. KWIKBIT DISCLAIMS ALL WARRANTIES, EXPRESSED OR IMPLIED,
INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE
PRACTICE.

IN NO EVENT SHALL KWIKBIT OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL,
CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR
LOSS OF DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF
KWIKBIT HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.




Kwikbit K60i User Guide
Confidential & Proprietary                                                                      -3-


                                                         K60i User Guide




Table of Contents

Preface                                                                     6

    Preface overview                                                        6

    About this guide                                                        6

    Additional documentation                                                6

    Additional help                                                         7

Kwikbit K60i System Overview                                                7

K60i System Description                                                     9

Technical Specifications                                                   11

    System Specifications                                                  11

    Radio Specifications                                                   12

    Mechanical, Power and Environmental Specifications                     13

    System Enclosure                                                       14

System Throughput                                                          14

Element and Network Management                                             15

Ethernet Bridge Support                                                    17

Installation Planning                                                      18

Using the K60i Web User Interface (UI)                                     18

    Requirements                                                           18

    K60i Web UI Page                                                       19

        Logging In                                                         19

System Provisioning                                                        20

    Initial System Setup and IP Configurations                             20



Kwikbit K60i User Guide
Confidential & Proprietary                                                 -4-


                                       K60i User Guide


Appendices                                               22

    Glossary                                             22

    FCC Statement                                        23

    FCC Radiation Exposure Statement                     23




Kwikbit K60i User Guide
Confidential & Proprietary                               -5-


                                                                 K60i User Guide



1 Preface
    1.1 Preface overview
Thank you for choosing the K60i system from Kwikbit. This guide introduces you to system
concepts, system architecture and commonly used terms.

This preface describes:

●   Audience for this guide
●   Additional documentation
●   Where to go for more help

    1.2 About this guide
This guide provides an overview of the K60i system, its components, its network
architecture, and how it is configured and a deployed.

This guide is intended for network and system administrators who must install, configure,
and manage K60i distribution networks. This guide is meant to provide an overview to the
system. This guide does not provide detailed information on installing or operating the
system.

It is assumed readers of this guide are familiar with:

●   Basic networking concepts
●   Layer 2 (link layer) of OSI model
●   Layer 3 (network layer) of OSI model
●   Routing and switching in networks
●   Radio frequency (RF) systems engineering
●   Virtual local area network (VLAN) technology

    1.3 Additional documentation
If you cannot find the information you need in this guide, you may want to refer to the
following documents:

    ●   K60i Physical Installation Guide
    ●   Kwikbit Edge Controller User Manual




Kwikbit K60i User Guide
Confidential & Proprietary                                                             -6-


                                                                      K60i User Guide



   1.4 Additional help
Kwikbit is committed to providing our customers with high quality technical support via the
following methods:

                             Web         www.kwikbit.com/support
                             E-mail      support@kwikbit.com
                             Phone       +1 (952) 657-5628




2 Kwikbit K60i System Overview




                    Figure 1: K60i System in a Point-to-Multipoint (PtMP)
                            Wireless Communication Application

Kwikbit is a leader in gigabit wireless distribution solutions that intelligently adapt to
challenging environments to maximize performance and reliability.

The K60i system operates in the 60 GHz unlicensed frequency band and is designed
primarily for line-of-sight (LoS) operation. Non-line-of-sight (NLoS) operation is possible
within short range and in the presence of reflective surfaces. By utilizing advanced
beamforming techniques, the K60i system automatically adapts in Point to Multi-Point
(PMP) communication configuration and is adaptable to changes in the operating
environment. The beam forming capability also makes system installation simple for



Kwikbit K60i User Guide
Confidential & Proprietary                                                                    -7-


                                                                   K60i User Guide


non-technical staff as precise mechanical alignment, as required by previous generation 60
GHz systems, is not required.

The K60i system is designed for use in multiple applications including IoT backhaul
(sensors, security cameras, etc.), optical fiber extension, and corporate and enterprise data
backhaul services by providing 1 Gbps of symmetric throughput.

The K60i system operates in unlicensed Time Division Multiplexing (TDD) band 57.05 –
64.00 GHz in both Point to Point (PTP) and Point to Multi-Point (PtMP) configurations. Some
of the main product characteristics are shown in Table 1.

                             Table 1: Main K60i Characteristics

             Duplex Mode                   Time Division Multiplexing (TDD)

             Physical Layer / Antenna      64 patch beamforming antenna
             System

             Operation Configuration       PtP and PtMP

             Capacity                      1.86 Gbps goodput aggregate

             Symmetry                      Dynamic downlink (DL) and uplink
                                           (UP) based on offered load

             Frequency of Operation        57.05 – 64.00 GHz

             Channel Bandwidth             2.16 GHz

             Network Interface             3x gigabit Ethernet

             Form Factor                   4.25 x 4.25 x 2” with integrated
                                           antenna



The K60i system consists of the following components:

    ●   Hub Unit​: control communication to one or more Remote Units
    ●   Remote Unit​: scan for available Hub Units and connect to the Hub configured or
        assigned via the Edge Controller
    ●   Edge Controller​: Optional appliance computer that provides WebUI tools for
        deployment planning, commissioning, network configuration, management,


Kwikbit K60i User Guide
Confidential & Proprietary                                                                -8-


                                                                  K60i User Guide


        monitoring and fault isolation. Edge controller is highly recommended for networks
        of medium and large scale.

The K60i Hub and Remote Units are identical from a hardware perspective, only differing in
software configuration. The K60i has a small form factor that can be easily and
unobtrusively deployed in many different indoor environments.

3 K60i System Description
Kwikbit’s K60i wireless indoor backhaul solution is designed to meet the requirements of
network planners where rapid and flexible deployment, high reliability, multi-gigabit
capacity and excellent latency performance are needed. Applications for the system include
IoT gateway aggregation, Wi-Fi access point backhaul, video camera connectivity and other
gigabit IP based applications. The system can function either as a Point-to-Point (PTP) or
Point-to-Multipoint (PMP) wireless Ethernet bridge.

Some of the main characteristics of the system include:

    ●   Time Division Duplex (TDD):​ The K60i solution features TDD access mode with
        variable frame length.

    ●   Adaptive Modulation with Link Adaptation: ​The K60i system supports BPSK,
        QPSK and 16QAM on both the downlink and uplink path to achieve high capacity in
        the channel bandwidth (1.86 Gbps Ethernet layer throughput for combined
        downlink and uplink traffic).

    ●   Beamforming:​ Use of the 60 GHz band allows extremely fast communication, but
        also presents the challenge of limited propagation. Signals in the 60 GHz band are
        also more susceptible to disruption from physical barriers than at lower
        frequencies. The K60i system includes adaptive beamforming, a technique that
        enables robust multi-gigabit communications at greater distances. Kwikbit’s
        beamforming feature uses directional antennas to reduce interference and
        automatically focus a signal between two devices into a concentrated beam. During
        the beamforming process, devices establish communication and then fine-tune
        their antenna settings to improve the quality of directional communication until
        there is enough capacity for the desired data transmission.

        One key benefit of Kwikbit’s beamforming is that if an obstacle blocks the line of
        sight between two devices, for example, if someone walks between them, the
        devices can quickly establish a new communications pathway. Another benefit of
        the K60i beamforming is that non-technical personnel can quickly and easily install
        the system. Precise physical alignment of the radios, as required with previous 60



Kwikbit K60i User Guide
Confidential & Proprietary                                                               -9-


                                                                  K60i User Guide


        GHz products, is not required with the Kwikbit system. The beamforming feature
        also enables the PMP communication capability of the system.

    ●   Power Management:​ The K60i system utilizes the scheduled access mode to
        reduce power consumption. Devices connected with each other via a directional link
        schedule the periods during which they communicate and, in between those
        periods, they can sleep to save power. This capability allows devices to more
        precisely tailor their power management to their actual traffic workload, reduces
        potential co-channel interference and enables efficient spectrum utilization.

    ●   Advanced Security:​ The K60i system utilizes strong security mechanisms, including
        Galois/Counter Mode, a highly-efficient mode of encryption that is designed to
        support higher communication speeds. Encryption is based on the
        government-grade Advanced Encryption Standard (AES) and is implemented in
        hardware for performance and efficiency.

    ●   Integrated Antennas:​ The K60i units integrate a specially-designed, 64 element
        antenna module that enables a peak EIRP of 40 dBm with a 90º azimuthal and 40º
        vertical beam sweep range.

    ●   PMP with Dynamic Bandwidth Allocation:​ The K60i system can operate in PTP or
        PMP configurations with up to eight Remotes. The capacity allocated to each
        Remote is variable according to the requirements of connected devices.

    ●   Compact Form Factor:​ The K60i transceiver units are highly integrated, compact
        (107x107x50mm), and low in weight (388g), so they can be easily mounted on most
        ceiling structures and walls.

    ●   Connectivity:​ K60i backhaul devices include three standard RJ45 Gigabit Ethernet
        ports, two of which supply PoE power to connected Wi-Fi access points, IoT
        gateways, surveillance cameras and other payload communication devices.


The Kwikbit K60i system provides these network management features:

    ●   Each K60i unit incorporates a WebUI. This WebUI enables configuration, fault
        management, and administration of the unit, as well as provides system state and
        performance information.




Kwikbit K60i User Guide
Confidential & Proprietary                                                             - 10 -


                                                                      K60i User Guide




                    Figure 2: K60i Hub and Remote WebUI interface page


    ●   The Kwikbit Edge Controller is a very powerful part of the Kwikbit solution. The Edge
        Controller connects through an Ethernet connection to the root K60i unit and
        enables non-technical personnel to physically install an entire network without K60i
        units being configured on the bench in advance. A local or remote IT resource can
        design, commission and manage the network using the Edge Controller’s WebUI.
        The Edge Controller can be connected to the cloud for remote management of
        multiple locations.

4 Technical Specifications
   4.1 System Specifications

     Aggregate               Up to 1.8 Gbit/sec (Layer 2/ Ethernet)
     capacity

     Ethernet frame          Transparent bridging of all Ethernet types including VLAN
     type                    and VLAN stacking


Kwikbit K60i User Guide
Confidential & Proprietary                                                               - 11 -


                                                                          K60i User Guide


     Latency                  250 microseconds average

     L2 switching             Complete Layer 2 switching with VLAN support

     Security                 AES 128 with automatic secure key distribution

     Network                  Ethernet bridge, 802.1Q, DSCP/ToS/802.1p (IPv4/v6) and
     Attributes               802.1ad/ QinQ tagging

     Network                  3 x GigE RJ-45 (2x with PoE output)
     Interfaces

     Other Interfaces         LEDs indicators for power, link condition, signal strength,
                              and unit location

     Provisioning             Zero-touch deployment and commissioning with Edge
                              Controller web application

     Management               Web GUI and Edge Controller



   4.2 Radio Specifications


     Access                  Single carrier beamforming physical layer
     Technology

     Duplex                  Time Division Multiplexing (TDD)

     Modulation              BPSK, QPSK; 8 levels of adaptive modulation and coding
                             schemes

     Frequencies             57.05 - 64.00 GHz

     Channel                 2.16 GHz
     Bandwidth

     Antenna System          64 patch beamforming antenna with
                             90˚ horizontal and 40˚ vertical scan range




Kwikbit K60i User Guide
Confidential & Proprietary                                                                  - 12 -


                                                                       K60i User Guide


     Output power            40 dBm EIRP
     (maximum)

     Typical Range           100 meters



   4.3 Mechanical, Power and Environmental Specifications

     Configuration            Single-piece indoor unit with integrated antenna

     Dimensions               107 x 107 x 50 mm
     (H x W x D)              4.25 x 4.25 x 2 inches

     Weight                   388g / 13.7 ounces

     Power Input              12-48 VDC

     Power                    K60i only: 8 watts idle, 13 watts maximum
     Consumption              K60i + PoE: 58.4 watts maximum

     Power Output             PoE available on 2 ports for Vin = 48 Vdc:
                              802.3af (15.4 watts) on RJ45 port closest to DC input and
                              802.3at (30 watts) on middle RJ45

     Operating                0˚C to +45˚C
     temperature

     Humidity                 Up to 95% non-condensing

     UL                       62368-1

     ESD                      IEC EN 61000-4-2

     EMC                      IEC EN 61000-4-3




Kwikbit K60i User Guide
Confidential & Proprietary                                                                - 13 -


                                                                  K60i User Guide


   4.4 System Enclosure




                        Figure 3: K60i Backhaul Unit (Hub and Remote)

The K60i enclosure is a rugged casing that can be supplied with multiple mounting bracket
configuration options, including: high bay, exposed ceiling, office ceiling T-bar, and wall
mount. The mounting brackets allow for a range of orientation flexibility to enable
mounting in challenging locations. The ceiling bracket can accommodate up to four units.
The wall bracket can accommodate one or two units. The installed units then can be
interconnected for medium and large network deployments.

The mechanical enclosure for the transceiver Module has a 48 VDC power connector, three
RJ45 connectors for Gigabit Ethernet network connectivity and an opening to the factory
reset switch. Two of the three RJ45 port connectors provide PoE compliant power output to
power devices connected to the network.

5 System Throughput
The K60i system uses time division duplexing (TDD) access mode, employing a single
frequency for both transmit and receive paths. The throughput for the downlink and uplink
depends on a downlink-to-uplink frame bandwidth ratio. The ratio is automatically
adjusted based on the offered load in each direction, taking into account all Remotes
connected to an Hub in PMP. Furthermore, the system’s throughput depends on the

Kwikbit K60i User Guide
Confidential & Proprietary                                                             - 14 -


                                                                         K60i User Guide


Modulation and Coding Rate (MCS) which varies according to link and signal conditions. The
following table details Ethernet uplink and downlink combined throughput for a K60i link.

                    Table 8: Throughput Performance for Cyclic Prefix of 1/8

                                                                                      Data Rate
MCS Index             Modulation       NCBPS       Repetitions      Code Rate
                                                                                       (Mbit/s)

        1              π/2 BPSK           1             2               1/2              310

        2              π/2 BPSK           1             1               1/2              620

        3              π/2 BPSK           1             1               5/8              775

        4              π/2 BPSK           1             1               3/4              930

        5              π/2 BPSK           1             1              13/16            1007

        6              π/2 QPSK           2             1               1/2             1240

        7              π/2 QPSK           2             1               5/8             1550

        8              π/2 QPSK           2             1               3/4             1860




6 Element and Network Management
The K60i system supports the following network management interfaces:

    ●       K60i Web Interface (WebUI). Accessible via HTTP(S), the K60i WebUI provides an
            interactive visual toolset that allows an operator to modify the full configuration of
            the K60i system as well as view state, fault, and performance indicator.
    ●       The Edge Controller WebUI application provides complete access to configuration,
            state, performance and fault information for all K60i units in a network system.

The WebUI network management interface on the K60i system is accessible via HTTP(S).
Connect to the K60i system with your browser utilizing one of the following methods:

    ●       Local Name​: Connect a K60i transceiver unit directly to your computer by plugging
            an Ethernet cable into any of the K60i’s three RJ45 connectors. In the URL field on
            your computer’s browser type ​https://KB-XX-XX-XX.local​ where ​KB-XX-XX-XX​ is
            the Host name of the unit that appears on the sticker on the back of the unit. For


Kwikbit K60i User Guide
Confidential & Proprietary                                                                     - 15 -


                                                                      K60i User Guide


        example, if the unit Host name is ​KB-C5-6B-78​, then the URL address of the unit is
        https://KB-C5-6B-78.local​. Your browser will display a warning stating that the
        connection is not secure. You may ignore the warning and proceed connecting to
        the unit. To avoid the warning, please go to the Kwikbit support website, download
        the Kwikbit security certificate, and install it on your browser.
    ●   Management IP Address:​ An operator assigned, static, Automatic Private IP
        Addressing (APIPA) or Dynamic Host Configuration Protocol (DHCP) IP address can
        be used for remote management of the units. Both Hubs and Remotes need a
        management IP address. For the Hub, the management IP Address is accessible
        from the Ethernet side of the network, while for the Remote the management IP
        Address is accessible from the wireless side (i.e., from behind the Hub). All traffic to
        and from the management IP address can be encapsulated in an
        operator-configurable VLAN.

The optional Kwikbit Edge Controller’s management application automatically discovers all
connected K60i devices on the network and establishes a secure connection to each one
utilizing a security certificate provided by Kwikbit and customized by the customer. For
more information on the Kwikbit Edge Controller device and associated applications, please
refer to the Kwikbit Edge Controller User Manual.

The K60i system provides the following network management functions:

    1. Device configuration information and status is displayed on the WebUI page
       interface as shown above in Figure 2. When the mouse cursor is hovered over an
       Ethernet Port or wireless connections icon, detailed information is displayed. In the
       Wireless section, the list of wirelessly connected devices is displayed. The list of LAN
       connected devices is displayed in the LAN Peers section. The WebUI of a connected
       device is established by clicking on the device’s name.
    2. Configuration Management. The system configuration section covers several
       functional areas:
       ● Device
              o Device location
              o Device description
       ● Wired Network
              o Device IP address assignment
                      ▪ Static address
                      ▪ DHCP – requires DHCP server
                      ▪ Automatic Zero Configuration address assignment
              o Management VLAN
              o Ethernet ports
                      ▪ Enable / Disable
                      ▪ PoE Enable / Disable (port 2 and 3)
       ● Wireless Network


Kwikbit K60i User Guide
Confidential & Proprietary                                                                  - 16 -


                                                                   K60i User Guide


             o Device role
             o SSID
             o Airlink passcode
             o Channel frequency
             o Preferred Hub (if device configured as Remote)
    3. Administration Operations:
       ● Flash LEDs of the device – used to identify location of physically installed device
       ● Change administration password of the device
       ● Upgrade device software
       ● Reboot the device

To reset the device to factory defaults:
    ● cycle the power
    ● during power-up, observe the LEDs: there should be two illuminated.
    ● Keep your eyes peeled on the LEDs, after about a minute, a flashing pattern will
       appear
    ● the flashing pattern signals the start of a brief window of opportunity for you to
       press the reset button (a round toothpick or an unfolded paper clip works good for
       this).
    ● Press the button and hold it until you see a distinctive flashing pattern
    ● Once this distincting flashing pattern appears, release the button
    ● the device is now operating at factory default settings
    ● The login password is “kwikbit_root”




7 Ethernet Bridge Support
Designed to seamlessly integrate into existing Ethernet backhaul or general-purpose
networks, the K60i system is built for Ethernet connectivity services and provides network
functionality as a standard Layer 2 (L2) Transparent Bridge (IEEE 802.1d), whereby the K60i
cluster (a cluster being one Hub with its group of up to eight Remotes) is the bridge, and
the Ethernet ports on the Hub and associated Remotes are the ports of the bridge.

The embedded bridge functionality performs Media Access Control (MAC) address learning
(up to 4096 MAC addresses). This function allows the Hub to perform an optimal allocation
of radio resources by sending traffic to the Remote behind which the destination of that
traffic is located.

The K60i system allows network management traffic to be encapsulated in a dedicated
management VLAN and can transport standard Ethernet frames (up to 1518 bytes).




Kwikbit K60i User Guide
Confidential & Proprietary                                                               - 17 -


                                                                  K60i User Guide


8 Installation Planning
When planning the installation of K60i systems, refer to the Kwikbit K60i Install Guide and
delegate physical install to appropriately trained professionals. When unpacking K60i
backhaul units during install, be sure to do the following for each unit:

    ●   Locate the label on the unit casing that lists the Serial Number (SN) and Host name
        of the unit
    ●   Record the SN on your registration card for future reference
    ●   Record the Host name for future reference when provisioning the system

After installation of the K60i backhaul units, perform the tasks described in Chapter 11
“System Provisioning”.

9 Using the K60i Web User Interface (UI)
   9.1 Requirements
The K60i embedded WebUI allows for direct configuration of both Hub and Remote units. It
is a standard web application that runs directly on the K60i unit and is accessible through
the default port for HTTPS (443) at URL https://<Host name of the unit>. Your browser will
display a warning stating that the connection is not secure. You may ignore the warning
and proceed connecting to the unit. To avoid the warning, go to the Kwikbit support
website, download the Kwikbit security certificate, and install it on your browser.

The recommended browsers for the K60i WebUI are:

    ●   Google Chrome
    ●   Safari

Operating System (OS) support for K60i WebUI:

    ●   Windows
    ●   Mac OS X
    ●   Unix
    ●   Linux

Note: With the exception of IE9, the K60i WebUI supports the most recent web browser and
OS versions.

Required basic K60i unit configuration tasks can be performed using the units WebUI;
however, the Kwikbit Edge Controller can be used to quickly and efficiently plan,



Kwikbit K60i User Guide
Confidential & Proprietary                                                                 - 18 -


                                                                     K60i User Guide


commission, configure and monitor small to large K60i networks. See the K60i Edge
Controller User Guide for details.

   9.2 K60i Web UI Page
The K60i WebUI is a single page that provides device status as well as configuration
options.

9.2.1 Logging In
Use your browser to connect to K60i device’s WebUI as described above. It is not necessary
to login to the system in order to view the WebUI page. You will then be prompted to login
once you click on any one of the configuration tabs if you do not have a security certificate
installed on your computer. The security certificate based authentication option is available
when utilizing an Edge Controller to manage the network.

The default username and password is as follows:

        User Name:      root
        Password:       kwikbit_root

The page remains read-only if you do not login to the system and only gives general system
information.

At the top of the WebUI screen, general node information including node name, node
description, model number and user is displayed. There are two network sections on the
page, Wireless and Wired.

The ​Wireless Network ​section displays the connection SSID, the unit role (Hub or Remote)
and all current wireless connections. If the unit is a Hub, all currently linked Remotes will be
displayed under connections. If the unit is a Remote, only one connection to a Hub can be
listed. Each connection displays the connected unit name as well as graphical
representation of the signal quality of the connection. By clicking on the connected device’s
name, a browser page of that device is opened. By hovering over the signal quality graphic,
detailed signal level information is displayed. You can change SSID and unit Role
configuration by clicking on the tool icon in the section banner, assuming you are an
authorized user.

The ​Wired Network​ section displays the unit’s assigned IP address and the status of the
three Gigabit Ethernet ports. By hovering over the Ethernet port icons, detailed port status
information is displayed. The unit’s IP configuration can be changed by clicking on the tool
icon in the section banner. Clicking on the Ethernet port icons allows a user to enable and
disable ports as well as turn PoE output on or off for ports one and two.


Kwikbit K60i User Guide
Confidential & Proprietary                                                                 - 19 -


                                                                    K60i User Guide


The ​Device​ section displays and provides configuration capability for ​Device Location​ and
Device Description​.

The ​LAN Peers​ section displays the names of all K60i units that are connected to the
current unit over a LAN connection. In most cases, these would be collocated units that
provide additional wireless connectivity from that location.

The ​Administration​ section displays the software and the hardware versions of the device
and includes controls to change user password, upgrade device software, flash device LEDs
for device identification, and to reboot the device.

10 System Provisioning
Network planning, installation procedure and commissioning are most efficiently
performed using the Kwikbit Edge Controller. In addition, the Edge Controller enables
centralized network operation view and management. Please see the Kwikbit Edge
Controller User Guide for detailed information.

If it is desired to provision a K60i network without the use of edge controller, the following
tasks associated with preparing a K60i system must be followed:

    1.   Initial system setup and IP configurations
    2.   Setting units’ roles
    3.   Setting SSID and airlink connectivity passcode
    4.   Setting communication channel frequency

   10.1 Initial System Setup and IP Configurations
All new K60i units shipped from the factory are identical with a default software
configuration loaded. You must connect to the management interface in order to configure
the following system management parameters:

    1. Connect your computer directly to the unit with an Ethernet cable. Once connected,
       open a browser on the computer and enter the following URL:

https://KB-XX-XX-XX.local​ where ​KB-XX-XX-XX​ is the Host name of the unit that appears
       on the sticker on the back of the unit. If the unit Host name is ​KB-C5-6B-78​, for
       example, then the URL address of the unit is ​https://KB-C5-6B-78.local​. Initially, the
       browser will display a warning stating that the connection is not secure. You may
       ignore the warning and proceed connecting to the unit. To avoid receiving the
       browser warning, please visit the Kwikbit support site, download the Kwikbit security
       certificate and install it on your browser.




Kwikbit K60i User Guide
Confidential & Proprietary                                                                 - 20 -


                                                                   K60i User Guide


    2. After successfully opening the WebUI page, the unit’s IP address can be changed by
       clicking on the ​Wired Network​ section tool icon:
       ● When prompted for user name, enter root ​admin​ for the username and
           kwikbit_root​ for password.
       ● Select the desired address assignment protocol. If static address is selected,
           enter the network mask and default gateway.
       ● Click Submit and the unit will reboot with the new address assignment. Your
           browser will automatically reconnect and display the page.

    3. Click on the Wireless section tool icon to configure wireless communication
       parameters:

            ●   Select the role of the unit. When configuring a PTP or PMP communication
                system, only one of the wirelessly connected devices may be configured with
                a Hub role. The units connecting to the Hub wirelessly must be configured as
                Remotes.
            ●   Configure SSID, airlink passcode and channel frequency (not required on
                remote). These parameters must match between the Hub and all wirelessly
                connected Remotes in order to establish wireless communication.
            ●   If a configured Remote can connect to multiple Hubs, you may want to set
                the optimal Hub in the Preferred Hub field.
            ●   There needs to be a Hub node configured with Network Root = enable.
                Alternatively, each remote needs to be configured with “Preferred Hub”.
                Lacking both of these will result in Remote nodes periodically scanning
                attempting to locate the Root node.

            ●   Click ​Submit​ to save changes.

    4. Click on the tool icon in the Device section to configure the ​Location​ at which the
       device will be physically installed and the description of the device. Click ​Submit​.
    5. In the Admin section, click on the second icon to change the management interface
       password.

The unit is now configured and ready to be installed.




Kwikbit K60i User Guide
Confidential & Proprietary                                                                - 21 -


                                                                       K60i User Guide


11 Appendices
   11.1 Glossary


                     DHCP    Dynamic Host Configuration Protocol

                     DL      Downlink

                     DNS     Domain Name System

                     FTP     File Transfer Protocol

                     Gbps    Gigabits per second

                     GHz     Gigahertz

                     HU      Hub Unit

                             Institute of Electrical and Electronics
                     IEEE
                             Engineers

                     L2      Layer 2

                     LAN     Local Area Network

                     LED     Light Emitting Diode

                     LoS     Line-of-Sight

                     MAC     Media Access Control

                     Mbps    Megabits per second

                     MCS     Modulation and Coding Scheme

                     MHz     Megahertz

                     NLoS    Non-Line-of-Sight

                     NMS     Network Management System

                     PC      Personal Computer



Kwikbit K60i User Guide
Confidential & Proprietary                                                               - 22 -


                                                                  K60i User Guide


                     PtMP    Point-to-Multipoint

                     PtP     Point-to-Point

                     QAM     Quadrature Amplitude Modulation

                     RF      Radio Frequency

                     RU      Remote Unit

                     SSID    Service Set Identifier

                     TDD     Time Division Duplexing

                     UL      Uplink

                     VLAN    Virtual Local Area Network

                     VDC     Volts Direct Current



   11.2 FCC Statement
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.

This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired
operation.

   11.3 FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. A minimum of 20 centimeters (11 inches) of separation between the K60i and
all persons shall be maintained.




Kwikbit K60i User Guide
Confidential & Proprietary                                                              - 23 -



Document Created: 2019-06-11 20:19:07
Document Modified: 2019-06-11 20:19:07

© 2019 FCC.report