RF Exposure Info

FCC ID: 2AMLFJC200

RF Exposure Info

Download: PDF
FCCID_4151811

                                                                                               REPORT No.:SZ18120224S01




                                            RF EXPOSURE
                         EVALUATION REPORT

                    APPLICANT                             : Shenzhen Jimi IOT Co.,Ltd

                    PRODUCT NAME                          : Telematics Dashcam

                    MODEL NAME                            : JC200,TD-200,C18

                    BRAND NAME                            : Jimi

                    FCC ID                                : 2AMLFJC200
                                                               47CFR 2.1091
                    STANDARD(S)                           :
                                                               KDB 447498
                    RECEIPT DATE                          : 2018-12-20

                    TEST DATE                             : 2019-01-02 to 2019-01-15

                    ISSUE DATE                            : 2019-01-16




                                                                       Edited by:
                                                                                               LiangYumei(Rapporteur)


                                                                       Approved by:
                                                                                               Peng Huarui( Supervisor )


NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.


 MORLAB
                         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                              Page1of 10


                                                                                            REPORT No.:SZ18120224S01

                                                          DIRECTORY

1. Technical Information ········································································································ 3
1.1    Applicant and Manufacturer Information ····································································· 3
1.2    Equipment under Test (EUT) Description ···································································· 3
1.3    Photographs of the EUT ································································································· 4
1.4    Identification of all used EUT ························································································ 5
1.5    Applied Reference Documents ····················································································· 5
2. Device Category and RF Exposure Limit········································································ 6
3. RF Output Power ················································································································ 7
4. RF Exposure Evaluation ··································································································· 9
Annex A General Information ······························································································· 10




                                                                  Change history
             Version                                   Date                                    Reason of changed
                1.0                              2019-01-16                                              Original




MORLAB
                      SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555    Fax: 86-755-36698525
                      FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                      Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                         Page2of 10


                                                                                        REPORT No.:SZ18120224S01
1. Technical Information
    Note: Provide by applicant.

1.1 Applicant and Manufacturer Information

  Applicant:                               Shenzhen Jimi IOT Co.,Ltd
                                           4/F, Building C, Gaoxinqi Industrial Park, Liuxian 1st Road, No.67 Xin'an
  Applicant Address:
                                           Street, Bao'an District, Shenzhen, China
  Manufacturer:                            Shenzhen Jimi IOT Co.,Ltd
                                           4/F, Building C, Gaoxinqi Industrial Park, Liuxian 1st Road, No.67 Xin'an
  Manufacturer Address:
                                           Street, Bao'an District, Shenzhen, China


1.2 Equipment under Test (EUT) Description

 EUT Type:                                Telematics Dashcam
 Hardware Version:                        KM8216_MAIN_V4.0
 Software Version:                        KM8216_EN_USB_V1.2_20181218
                                          GSM 850: 824.2 MHz ~ 848.8 MHz
                                          GSM 1900: 1850.2 MHz ~ 1909.8 MHz
 Frequency Bands:                         WCDMA Band II: 1852.4 MHz ~ 1907.6 MHz
                                          WCDMA Band V: 826.4 MHz ~ 846.6 MHz
                                          WLAN 2.4GHz: 2412 MHz ~ 2462 MHz
                                          GSM: GMSK
                                          WCDMA: QPSK
 Modulation Mode:
                                          802.11b: DSSS
                                          802.11g/n-HT20: OFDM
                                          WWAN: FPC Antenna
 Antenna Type:
                                          WLAN: Ceramic Antenna
 Antenna Gain:                            0dBi


Note: According to the designer, the model JC200, TD-200 and C18 are accordant in both hardware and
software, these three models only differ in model name.




MORLAB
                  SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                  FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                  Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page3of 10


                                                                                     REPORT No.:SZ18120224S01
1.3 Photographs of the EUT
1.   EUT Front View




2.   EUT Back View




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                 Page4of 10


                                                                                         REPORT No.:SZ18120224S01
1.4 Identification of all used EUT
The EUT identity consists of numerical and letter characters, the letter character indicates the test
sample, and the following two numerical characters indicate the software version of the test sample.

          EUT Identity              Hardware Version                                     Software Version
               1#                KM8216_MAIN_V4.0                            KM8216_EN_USB_V1.2_20181218



1.5 Applied Reference Documents
Leading reference documents for testing:
 No.            Identity                                                              Document Title
  1      47 CFR§2.1091                       Radiofrequency Radiation Exposure Evaluation: mobile devices
  2      KDB 447498 D01v06                   General RF Exposure Guidance




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                      Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China      Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                     Page5of 10


                                                                                        REPORT No.:SZ18120224S01
2. Device Category and RF Exposure Limit
Per user manual, Based on 47CFR 2.1091, this device belongs to mobile device category with
General Population/Uncontrolled exposure.
Mobile Devices:
47CFR 2.1091(b)
For purposes of this section, a mobile device is defined as a transmitting device designed to be
used in other than fixed locations and to generally be used in such a way that a separation distance
of at least 20 centimeters is normally maintained between the transmitter's radiating structure(s)
and the body of the user or nearby persons. In this context, the term “fixed location” means that the
device is physically secured at one location and is not able to be easily moved to another location.
Transmitting devices designed to be used by consumers or workers that can be easily re-located,
such as wireless devices associated with a personal computer, are considered to be mobile devices
if they meet the 20 centimeter separation requirement.
GENERAL POPULATION / UNCONTROLLED EXPOSURE
The general population/uncontrolled exposure limits are applicable to situations in which the
general public may be exposed or in which persons who are exposed as a consequence of their
employment may not be made fully aware of the potential for exposure or cannot exercise control
over their exposure. Members of the general public would come under this category when exposure
is not employment-related; for example, in the case of a wireless transmitter that exposes persons
in its vicinity. Warning labels placed on low-power consumer devices such as cellular telephones
are not considered sufficient to allow the device to be considered under the occupational/controlled
category, and the general population/uncontrolled exposure limits apply to these devices.
                       TABLE 1—LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)

      Frequency                 Electric field                       Magnetic field                Power               Averaging
        range                     strength                             strength                   density                time
        (MHz)                       (V/m)                               (A/m)                    (mW/cm2)              (minutes)

                      (B) Limits for General Population/Uncontrolled Exposure

       0.3-1.34                         614                                   1.63                   *(100)                   30

       1.34-30                         824/f                                 2.19/f                *(180/f2)                  30

        30-300                         27.5                                  0.073                     0.2                    30

       300-1500                            -                                     -                  f/1500                    30

    1500-100,000                           -                                     -                     1.0                    30
    f = frequency in MHz* = Plane-wave equivalent power density




MORLAB
                  SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                  FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                  Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page6of 10


                                                                                           REPORT No.:SZ18120224S01
3. RF Output Power
<GSM>
        GSM850                      Burst Average Power (dBm)                    Tune-up     Frame-Average Power (dBm)                    Tune-up

     TX Channel                   128              190             251             Limit    128             190           251              Limit

   Frequency (MHz)               824.2           836.6            848.8           (dBm)    824.2           836.6         848.8            (dBm)

    GSM 1 Tx slot                33.60           32.96            33.20            34.00   24.60           23.96         24.20             25.00

    GPRS 1 Tx slot               33.67           33.01            33.26            34.00   24.67           24.01         24.26             25.00

   GPRS 2 Tx slots               32.95           32.27            32.55            33.00   26.95           26.27         26.55             27.00

   GPRS 3 Tx slots               31.46           30.76            31.06            31.50   27.20           26.50         26.80             27.24

   GPRS 4 Tx slots               30.57           29.87            30.18            31.00   27.57           26.87         27.18             28.00



      GSM1900                       Burst Average Power (dBm)                    Tune-up     Frame-Average Power (dBm)                    Tune-up

     TX Channel                   512              661             810             Limit    512             661           810              Limit

   Frequency (MHz)               1850.2           1880           1909.8           (dBm)    1850.2           1880        1909.8            (dBm)

    GSM 1 Tx slot                30.30           29.61            29.29            30.50   21.30           20.61         20.29             21.50

    GPRS 1 Tx slot               30.37           29.70            29.36            30.50   21.37           20.70         20.36             21.50

   GPRS 2 Tx slots               29.59           28.89            28.50            30.00   23.59           22.89         22.50             24.00

   GPRS 3 Tx slots               28.18           27.57            27.21            28.50   23.92           23.31         22.95             24.24

   GPRS 4 Tx slots               27.29           26.68            26.42            27.50   24.29           23.68         23.42             24.50



<WCDMA>
         Band                                  WCDMA II                                                 WCDMA V
                                                                                 Tune-up                                                  Tune-up
     TX Channel                   9262            9400            9538                     4132             4182          4233
                                                                                   Limit                                                   Limit
     Rx Channel                   9662            9800            9938                     4357             4407          4458
                                                                                  (dBm)                                                   (dBm)
   Frequency (MHz)               1852.4           1880           1907.6                    826.4           836.4         846.6

    RMC 12.2Kbps                 22.49           22.90            22.51            23.00   23.03           22.61         22.88             23.50

   HSDPA Subtest-1               22.65           22.82            22.32            23.00   22.54           23.14         22.89             23.50

   HSDPA Subtest-2               22.41           22.87            22.64            23.00   23.00           22.79         22.64             23.50

   HSDPA Subtest-3               22.37           22.13            21.78            22.50   22.36           22.54         22.79             23.00

   HSDPA Subtest-4               21.24           21.78            21.53            22.50   22.86           22.41         22.57             23.00

   HSUPA Subtest-1               22.65           22.82            22.32            23.00   22.42           22.38         21.86             23.00

   HSUPA Subtest-2               22.41           22.87            22.64            23.00   22.28           21.91         22.56             23.00

   HSUPA Subtest-3               22.37           22.13            21.78            22.50   21.91           22.38         21.74             22.50

   HSUPA Subtest-4               21.24           21.78            21.53            23.00   22.45           21.87         22.63             23.00

   HSUPA Subtest-5               21.43           21.98            20.65            22.00   22.73           21.99         22.67             23.00




MORLAB
                     SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555    Fax: 86-755-36698525
                     FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                     Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                        Page7of 10


                                                                                        REPORT No.:SZ18120224S01
<WLAN 2.4GHz >

                                                      Frequency              Average          Tune-Up
              Mode                Channel                                                                      Power Setting       Duty Cycle %
                                                         (MHz)            power (dBm)           Limit


                                    CH 1                  2412                 15.43            15.50              20.00
             802.11b
                                    CH 6                  2437                 16.44            16.50              20.00                97.89
              1Mbps
  2.4GHz                           CH 11                  2462                 15.57            16.00              20.00

  WLAN                              CH 1                  2412                 11.57            12.00              20.00
             802.11g
                                    CH 6                  2437                 13.93            14.50              20.00                89.14
              6Mbps
                                   CH 11                  2462                 12.30            12.50              20.00

                                    CH 1                  2412                 11.56            12.00              20.00
           802.11n-HT20
                                    CH 6                  2437                 13.86            14.00              20.00                88.36
              MCS0
                                   CH 11                  2462                 12.26            12.50              20.00




MORLAB
              SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                       Tel: 86-755-36698555    Fax: 86-755-36698525
              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China       Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                     Page8of 10


                                                                                                 REPORT No.:SZ18120224S01

4. RF Exposure Evaluation
Standalone transmission evaluation:
                                                           Maximum                 Antenna                               Power              Limit for
                                Frequency                                                              EIRP
         Bands                                          Tune-up Limit                 Gain                               density                 MPE
                                   (MHz)                                                               (mW)
                                                              (dBm)                   (dBi)                             (mW/cm²)           (mW/cm²)
        GSM850                     824.2                      28.00                        0          829.851            0.165                0.549
        GSM1900                   1850.2                      24.50                        0          370.681            0.074                1.000
     WCDMA Band II                  1880                      23.00                        0          199.526            0.040                1.000
     WCDMA Band V                  836.4                      23.50                        0          223.872            0.045                0.558
      2.4G WLAN                     2437                      16.50                        0          44.668             0.009                1.000


Simultaneous transmission evaluation:
                                                 Power                                     Power
                                                                     Limit 1                               Limit 2            Result
        Transmit Condition                     density 1                                  density 2                                                   Limit
                                                                  (mW/cm²)                               (mW/cm²)          (mW/cm²)
                                              (mW/cm²)                                (mW/cm²)
      GSM850+2.4G WLAN                           0.165               0.549                 0.009           1.000              0.310               1.000
     GSM1900+2.4G WLAN                           0.074               1.000                 0.009           1.000              0.083               1.000
WCDMA Band II+2.4G WLAN                          0.040               1.000                 0.009           1.000              0.049               1.000
WCDMA Band V+2.4G WLAN                           0.045               0.558                 0.009           1.000              0.090               1.000

Note:
1.  According to KDB 447498, SAR test exclusion conditions are based on source-based
    time-averaged maximum conducted output power of the RF channel requiring evaluation,
    adjusted for tune-up tolerance, and the minimum test separation distance required for the
    exposure conditions.
2. MPE calculation method
                          Power Density = EIRP/4πR²
     Where: EIRP = P+G
             P = Output Power (dBm)
             G = Antenna Gain (dBi)
             R = Separation Distance (20cm)
3. The worst condition for WWAN & WLAN will be calculated for transmitting simultaneously.
      Formula: Result=Power density 1/ limit 1 + power density 2/ limit 2




MORLAB
                    SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                          Tel: 86-755-36698555     Fax: 86-755-36698525
                    FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                    Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China          Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                               Page9of 10


                                                                                     REPORT No.:SZ18120224S01
                       Annex A General Information
1. Identification of the Responsible Testing Laboratory
                                                    Shenzhen Morlab Communications Technology Co., Ltd.
  Laboratory Name:
                                                    Morlab Laboratory
                                                    FL.3, Building A, FeiYang Science Park, No.8 LongChang Road,
  Laboratory Address:                               Block 67, BaoAn District, ShenZhen, GuangDong Province, P.
                                                    R. China
  Telephone:                                        +86 755 36698555
  Facsimile:                                        +86 755 36698525


2. Identification of the Responsible Testing Location
                                                    Shenzhen Morlab Communications Technology Co., Ltd.
  Name:
                                                    Morlab Laboratory
                                                    FL.3, Building A, FeiYang Science Park, No.8 LongChang Road,
  Address:                                          Block 67, BaoAn District, ShenZhen, GuangDong Province, P.
                                                    R. China




                                                       END OF REPORT




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                Page10of 10



Document Created: 2019-01-25 11:10:58
Document Modified: 2019-01-25 11:10:58