RF Exposure Report

FCC ID: 2AMKM-STREAM

RF Exposure Info

Download: PDF
FCCID_3582976

BST1709988160001Y-ER-2-E




                                     RF Exposure Report

FCC ID: 2AMKM-STREAM

RF Exposure Measurement

The limit for Maximum Permissible Exposure (MPE) specified in FCC 1.1310 is followed. The gain of the antennas
used in the product is extracted from the Antenna data sheets provided and also the maximum total power input to
the antenna is measured. Through the Friis transmission formula and the maximum gain of the antenna, we can
calculate the distance, away from the product, where the limit of MPE is reached.
Although the Friis Transmission formula is far field assumption, the calculated result of that is an over-prediction
for near field power density. It is taken as worst case to specify the safety range.


RF Exposure Limit

According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the
environmental impact of the human exposure to radio-frequency (RF) radiation as specified in 1.1307 (b)

Limits for Maximum Permissible Exposure (MPE)


F= Frequency in MHz




   Frequency Range             Electric Field            Magnetic Field              Power Density
   (MHz)                       Strength (V/m)            Strength (A/m)              (mW/cm²)
   Limits for Occupational / controlled Exposures
   300 - 1500                  --                        --                          F/300
   1500 – 100000               --                        --                          5.0
   Limits for General population / Uncontrolled Exposure
   300 - 1500                  --                        --                          F/1500
   1500 – 100000               --                        --                          1.0




                                                        one


BST1709988160001Y-ER-2-E




 Friss Formula

 Friss Transmission Formula: Pd = (Pout * G) / (4*pi*r²)

 Where
 Pd = power density in mW/cm²
 Pout = output power to antenna in mW
 G = gain of antenna in linear scale
 Pi = 3.1416
 R = Distance between observation point and the center of radiator in cm

 If we know the maximum gain of the antenna and the total output power to the antenna, through calculation, we
 will know MPE value at distance 20cm.

 EUT Operation condition

 EUT was enabled to transmit and receive at lowest, middle and highest channels.

 Classification

 The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. Warning
 statement to the user for keeping at least 20cm or more separation distance from the antenna should be included
 in the User manual. So, this device is classified as Mobile device.

ANT Gain (G) 1dBi (1.26)
2412-2462MHz:


                            Channel      Output Power        Output Power
                           Frequency                             to Antenna   Power Density     Limit
        Protocol                           to Antenna
                                                                                (mW/cm²)      (mW/cm²)
                             (MHz)            (dBm)                 (mW)
        802.11b               2437             15.75                37.58        0.0094          1.000
      802.11g                 2462             12.63                18.32        0.0046          1.000
    802.11n HT20              2437             12.75                18.84        0.0047          1.000

Then SAR evaluation is not required