Test Report

FCC ID: 2AMH2-BH364A

Test Report

Download: PDF
FCCID_4338726

                                           FCC PART 15.247
                                               TEST REPORT

                                                              For

                MPOW TECHNOLOGY CO., LIMITED
       RM 603, 6/F, HANG PONT COMM BLDG 31 TONKIN ST CHEUNG SHA WAN KL HK China



                                       FCC ID: 2AMH2-BH364A


            Report Type:                                 Product Name:
            Original Report                              KIDS WIRELESS HEADPHONE


                  Report Number:           RDG190523001-00B


                      Report Date:         2019-06-04


                                           Jerry Zhang
                     Reviewed By:          EMC Manager

                                           Bay Area Compliance Laboratories Corp. (Dongguan)
                 Test Laboratory:          No.69 Pulongcun, Puxinhu Industry Area,
                                           Tangxia, Dongguan, Guangdong, China
                                           Tel: +86-769-86858888
                                           Fax: +86-769-86858891
                                           www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be
used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal
Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”.


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                          Report No.: RDG190523001-00B




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................4
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................4
 OBJECTIVE ...................................................................................................................................................................4
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................4
 TEST METHODOLOGY ..................................................................................................................................................4
 MEASUREMENT UNCERTAINTY ....................................................................................................................................5
 TEST FACILITY .............................................................................................................................................................5
SYSTEM TEST CONFIGURATION ..........................................................................................................................6
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................6
  EQUIPMENT MODIFICATIONS .......................................................................................................................................6
  EUT EXERCISE SOFTWARE ..........................................................................................................................................6
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................7
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................7
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................8
SUMMARY OF TEST RESULTS ...............................................................................................................................9
FCC §15.247 (i) & §1.1310 & §2.1093- RF EXPOSURE..........................................................................................10
  APPLICABLE STANDARD ............................................................................................................................................10
FCC §15.203 - ANTENNA REQUIREMENT...........................................................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  ANTENNA INFORMATION AND CONNECTOR CONSTRUCTION.....................................................................................11
FCC §15.207 (a)– AC LINE CONDUCTED EMISSIONS ......................................................................................12
  APPLICABLE STANDARD ............................................................................................................................................12
  EUT SETUP ................................................................................................................................................................12
  EMI TEST RECEIVER SETUP .......................................................................................................................................12
  TEST PROCEDURE ......................................................................................................................................................13
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................13
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................13
  TEST DATA ................................................................................................................................................................14
FCC §15.209, §15.205, §15.247(d) - SPURIOUS EMISSIONS .................................................................................17
  APPLICABLE STANDARD ............................................................................................................................................17
  EUT SETUP ................................................................................................................................................................17
  EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP ..............................................................................................18
  TEST PROCEDURE ......................................................................................................................................................18
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................18
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................19
  TEST DATA ................................................................................................................................................................19
FCC §15.247(a) (2) –6 dB EMISSION BANDWIDTH .............................................................................................25
  APPLICABLE STANDARD ............................................................................................................................................25
  TEST PROCEDURE ......................................................................................................................................................25
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................25
  TEST DATA ................................................................................................................................................................25
FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER ......................................................28
  APPLICABLE STANDARD ............................................................................................................................................28
  TEST PROCEDURE ......................................................................................................................................................28

                                                                                                                                                            Page 2 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                           Report No.: RDG190523001-00B


    TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................28
    TEST DATA ................................................................................................................................................................29
FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE .......................................................30
  APPLICABLE STANDARD ............................................................................................................................................30
  TEST PROCEDURE ......................................................................................................................................................30
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................30
  TEST DATA ................................................................................................................................................................30
FCC §15.247(e) - POWER SPECTRAL DENSITY .................................................................................................32
  APPLICABLE STANDARD ............................................................................................................................................32
  TEST PROCEDURE ......................................................................................................................................................32
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................32
  TEST DATA ................................................................................................................................................................32




                                                                                                                                                             Page 3 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190523001-00B

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

                     EUT Name:         KIDS WIRELESS HEADPHONE
                     EUT Model:        BH364A
                 Multiple Model:       BH364B
            Operation Frequency:       2402-2480 MHz
          Maximum Output Power
                                       2.16 dBm
                    (Conducted):
               Modulation Type:        GFSK
             Rated Input Voltage:      DC3.7V from Battery or DC5V from adapter
             External Dimension:       176.5mm(L)*180mm(W)*74mm(H)
                  Serial Number:       190523001
             EUT Received Date:        2019.05.24

Notes: Model BH364A was selected for fully testing, the detailed information about the difference among BH364B
and model BH364A can be referred to the declaration letter which was stated and guaranteed by the manufacturer.


Objective
This report is prepared on behalf of MPOW TECHNOLOGY CO., LIMITED in accordance with Part 2,
Subpart J, Part 15, Subparts A and C of the Federal Communications Commission’s rules

The tests were performed in order to determine the compliance of the EUT with FCC Rules Part 15-
Subpart C, section 15.203, 15.205, 15.207, 15.209, 15.247 rules.

Related Submittal(s)/Grant(s)
FCC Part 15C DSS submissions with FCC ID: 2AMH2-BH364A.


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices and KDB 558074 D01
DTS Meas Guidance v05r02.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).




                                                                                                     Page 4 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190523001-00B

Measurement Uncertainty
            Parameter                                      Measurement Uncertainty
    Occupied Channel Bandwidth                                     ±5 %
    RF output power, conducted                                    ±0.61dB
  Power Spectral Density, conducted                               ±0.61 dB
                                          30M~200MHz: 4.55 dB,200M~1GHz: 5.92 dB,1G~6GHz: 4.98 dB,
    Unwanted Emissions, radiated
                                            6G~18GHz: 5.89 dB,18G~26.5G:5.47 dB,26.5G~40G:5.63 dB
   Unwanted Emissions, conducted                                    ±1.5 dB
           Temperature                                                ±1℃
             Humidity                                                 ±5%
   DC and low frequency voltages                                     ±0.4%
            Duty Cycle                                                 1%
 AC Power Lines Conducted Emission                        3.12 dB (150 kHz to 30 MHz)


Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the
FCC Public Access Link (PAL) database, FCC Registration No. : 897218, the FCC Designation No. :
CN1220.

The lab has been recognized by Innovation, Science and Economic Development Canada to test to
Canadian radio equipment requirements, the CAB identifier : CN0022.




                                                                                             Page 5 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190523001-00B

SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in engineering mode.
For Bluetooth LE mode, 40 channels are provided for testing:

                                    Frequency                                     Frequency
                Channel                                       Channel
                                      (MHz)                                         (MHz)
                   0                   2402                     20                   2442
                   1                   2404                     …                     …
                   …                    …                       …                     …
                   …                    …                       …                     …
                    ..                 …                        38                   2478
                   19                 2440                      39                   2480

EUT was tested with channel 0, 19 and 39.


Equipment Modifications
No modification was made to the EUT tested.


EUT Exercise Software
The maximum power was configured by system default setting: The test software ' Blue Test 3 ' only for
change modes and channels.

The duty cycle as below:

                            Ton                     Ton+off             Duty Cycle
                           (ms)                     (ms)                   (%)
                           0.451                    0.649                 69.49




                                                                                              Page 6 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                               Report No.: RDG190523001-00B

                                          Delta 2 [T1]               RBW       3 MHz     RF Att      30 dB
                          Ref Lvl                    0.70 dB         VBW       3 MHz
                           20 dBm              649.298597  s        SWT       3 ms      Unit           dBm
                     20
                            0.5 dB Offset                                       1 [T1]           -49.91 dBm
                                                                                                               A
                                                                                            1.370741 ms
                     10
                                                                                2 [T1]             0.70 dB
                                                                                          649.298597  s      SGL

                     0                                                          1 [T1]             0.25 dB
                                                                                          450.901804  s

                 -10
                                                                                                              1MA

                 -20



                 -30



                 -40


                                                           1               1   2
                 -50



                 -60



                 -70



                 -80
                          Center 2.44 GHz                       300  s/

                Date:           28.MAY.2019   16:27:25




Local Support Equipment List and Details

       Manufacturer                  Description                    Model                           Serial Number
         Unknown                         Adapter                      M4                                      /



Support Cable List and Details

         Cable                 Shielding                            Length
                                               Ferrite Core                              From Port                  To
       Description               Type                                (m)
       USB cable                    No              No                0.8                 Adapter                   EUT




                                                                                                                     Page 7 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)              Report No.: RDG190523001-00B

Block Diagram of Test Setup



                                                                                           LISN1



                                                                 10cm
                                                         EUT             Adapter




                                                                                      1.0 Meter
       Non-Conductive Table 80
       cm above Ground Plane

                                             1.5 Meter




                                                                                   Page 8 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190523001-00B

SUMMARY OF TEST RESULTS

               FCC Rules                            Description of Test               Result

       FCC §15.247 (i) & §1.1310 &
                                                       RF Exposure                  Compliance
                §2.1093
                §15.203                         Antenna Requirement                 Compliance

               §15.207 (a)                  AC Line Conducted Emissions             Compliance
            §15.205, §15.209,
                                                    Spurious Emissions              Compliance
               §15.247(d)
             §15.247 (a)(2)                          6 dB Bandwidth                 Compliance

             §15.247(b)(3)                Maximum Conducted Output Power            Compliance

               §15.247(d)             100 kHz Bandwidth of Frequency Band Edge      Compliance

               §15.247(e)                       Power Spectral Density              Compliance




                                                                                               Page 9 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190523001-00B

FCC §15.247 (i) & §1.1310 & §2.1093- RF EXPOSURE
Applicable Standard
According to§15.247(i) and §1.1310, systems operating under the provisions of this section shall be
operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of
the Commission’s guideline.

According to KDB447498 D01 General RF Exposure Guidance v06:

The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50
mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
        • f(GHz) is the RF channel transmit frequency in GHz
        • Power and distance are rounded to the nearest mW and mm before calculation
        • The result is rounded to one decimal place for comparison
        • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below

The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5
mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion.


Measurement Result

The max conducted power including tune-up tolerance is 3.0 dBm (2 mW).
[(max. power of channel, mW)/(min. test separation distance, mm)][√f(GHz)]
=2/5*(√2.480) = 0.6< 3.0

So the stand-alone SAR evaluation is not necessary.




                                                                                               Page 10 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG190523001-00B

FCC §15.203 - ANTENNA REQUIREMENT
Applicable Standard
According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
furnished by the responsible party shall be used with the device. The use of a permanently attached
antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered
sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a
broken antenna can be replaced by the user, but the user of a standard antenna jack or electrical connector
is prohibited. The structure and application of the EUT were analyzed to determine compliance with
section §15.203 of the rules. §15.203 state that the subject device must meet the following criteria:

a. Antenna must be permanently attached to the unit.
b. Antenna must use a unique type of connector to attach to the EUT.
c. Unit must be professionally installed, and installer shall be responsible for verifying that the correct
   antenna is employed with the unit.


Antenna Information And Connector Construction
The EUT has one internal antenna arrangement for BT, and the antenna gain is 0 dBi, fulfill the
requirement of this section. Please refer to the EUT photos.

Result: Compliance.




                                                                                                 Page 11 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190523001-00B

FCC §15.207 (a)– AC LINE CONDUCTED EMISSIONS
Applicable Standard
FCC§15.207(a)


EUT Setup




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.207.

The spacing between the peripherals was 10 cm.

The adapter was connected to the main lisn with a 120 V/60 Hz AC power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                      IF B/W
                              150 kHz – 30 MHz                      9 kHz




                                                                                              Page 12 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RDG190523001-00B

Test Procedure

During the conducted emission test, the adapter was connected to the first LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.


Corrected Amplitude & Margin Calculation
The basic equation is as follows:

VC = VR + AC + VDF
Cf = AC + VDF

Herein,
VC (cord. Reading): corrected voltage amplitude
VR: reading voltage amplitude
Ac: attenuation caused by cable loss
VDF: voltage division factor of AMN
Cf: Correction Factor

The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation
for margin calculation is as follows:

                                    Margin = Limit – Corrected Amplitude


Test Equipment List and Details

                                                                     Serial         Calibration   Calibration
      Manufacturer              Description           Model
                                                                    Number             Date        Due Date
           R&S               EMI Test Receiver        ESCI           101121         2019-03-23     2020-03-23
         Unknown               Coaxial Cable       C-NJNJ-50        C-0200-01       2018-09-05     2019-09-05
           R&S                 Test Software         EMC32        Version8.53.0        N/A            N/A
           R&S              Two-line V-network      ENV 216          101614         2018-12-10     2019-12-10

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                    Page 13 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)          Report No.: RDG190523001-00B

Test Data
    Environmental Conditions

             Temperature:             28.4 oC
        Relative Humidity:             58%
            ATM Pressure:            101.2kPa

     The testing was performed by Lily Xie on 2019-05-27

Test Result: Compliance

Test Mode: Charging




                                                                            Page 14 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                            Report No.: RDG190523001-00B

    AC120 V, 60 Hz, Line:


                         80

                         70
                                                                                                      Quasi-Peak Limit
                         60
                                                                                                         Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                          0
                          150k      300    400 500    800 1M           2M   3M     4M 5M 6   8 10M          20M      30M
                                                                 Frequency in Hz



                     Frequency            QuasiPeak       Bandwidth                  Corr.    Margin         Limit
                                                                            Line
                       (MHz)               (dBμV)           (kHz)                    (dB)      (dB)         (dBμV)
                      0.150000               38.5           9.000           L1       11.2      27.5           66.0
                         0.426418           27.6               9.000        L1        9.9      29.7           57.3
                         0.586300           28.9               9.000        L1        9.8      27.1           56.0
                         0.774673           28.1               9.000        L1        9.8      27.9           56.0
                         1.261437           27.0               9.000        L1        9.8      29.0           56.0
                         2.582287           24.8               9.000        L1        9.8      31.2           56.0

                     Frequency             Average        Bandwidth                  Corr.    Margin         Limit
                                                                            Line
                       (MHz)               (dBμV)           (kHz)                    (dB)      (dB)         (dBμV)
                      0.592163               26.1           9.000           L1        9.8      19.9           46.0
                         0.744445           23.8               9.000        L1        9.8      22.2           46.0
                         1.650223           22.4               9.000        L1        9.7      23.6           46.0
                         2.582287           21.1               9.000        L1        9.8      24.9           46.0
                         3.088796           21.8               9.000        L1        9.8      24.2           46.0
                         4.463546           20.3               9.000        L1        9.8      25.7           46.0




                                                                                                                     Page 15 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                             Report No.: RDG190523001-00B

    AC120 V, 60 Hz, Neutral:


                          80

                          70
                                                                                                       Quasi-Peak Limit
                          60
                                                                                                          Average Limit
                          50
          Level in dBμ




                          40

                          30

                          20

                          10

                          0
                          150k       300    400 500    800 1M           2M   3M     4M 5M 6   8 10M          20M      30M
                                                                  Frequency in Hz



                     Frequency             QuasiPeak       Bandwidth                  Corr.    Margin         Limit
                                                                             Line
                       (MHz)                (dBμV)           (kHz)                    (dB)      (dB)         (dBμV)
                      0.150000                40.5           9.000            N       11.2      25.5           66.0
                         0.580495            29.3               9.000         N        9.8      26.7           56.0
                         0.737074            27.6               9.000         N        9.8      28.4           56.0
                         1.261437            26.2               9.000         N        9.8      29.8           56.0
                         3.621856            22.7               9.000         N        9.8      33.3           56.0
                         11.601974           23.5               9.000         N        9.8      36.5           60.0

                     Frequency              Average        Bandwidth                  Corr.    Margin         Limit
                                                                             Line
                       (MHz)                (dBμV)           (kHz)                    (dB)      (dB)         (dBμV)
                      0.426418                19.8           9.000            N        9.9      27.5           47.3
                         0.592163            23.7               9.000         N        9.8      22.3           46.0
                         0.759409            21.3               9.000         N        9.8      24.7           46.0
                         1.248947            21.0               9.000         N        9.8      25.0           46.0
                         3.621856            16.6               9.000         N        9.8      29.4           46.0
                         11.601974           11.7               9.000         N        9.8      38.3           50.0




                                                                                                                      Page 16 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RDG190523001-00B


FCC §15.209, §15.205, §15.247(d) - SPURIOUS EMISSIONS
Applicable Standard
FCC §15.247 (d); §15.209; §15.205

EUT Setup
Below 1GHz:




Above 1GHz:




The radiated emission tests were performed in the 10 meters chamber test site for the range 30MHz to
1GHz and the 3 meters chamber A test site for above 1GHz, using the setup accordance with the ANSI
C63.10-2013. The specification used was the FCC 15.209, and FCC 15.247 limits.

The spacing between the peripherals was 10 cm.




                                                                                            Page 17 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190523001-00B

EMI Test Receiver & Spectrum Analyzer Setup

The system was investigated from 30 MHz to 25 GHz.

During the radiated emission test, the EMI test receiver & Spectrum Analyzer Setup were set with the
following configurations:

30MHz-1000MHz:

                    Measurement             RBW            Video B/W       IF B/W
                        QP                 120 kHz          300 kHz        120kHz

1GHz- 25GHz:

                       Measurement            Duty cycle       RBW         Video B/W
                           PK                    Any           1MHz          3 MHz
                                                >98%           1MHz          10 Hz
                            AV
                                                <98%           1MHz            1/T

Note: T is minimum transmission duration

If the maximized peak measured value complies with under the QP/Average limit more than 6dB, then it is
unnecessary to perform an QP/Average measurement.


Test Procedure

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

Data was recorded in Quasi-peak detection mode for frequency range of 30 MHz-1 GHz, peak and
Average detection modes for frequencies above 1 GHz.


Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit –Corrected Amplitude




                                                                                             Page 18 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG190523001-00B

Test Equipment List and Details

                                                                        Serial      Calibration    Calibration
    Manufacturer           Description             Model
                                                                       Number          Date         Due Date
        R&S            EMI Test Receiver           ESCI                100224       2018-12-10     2019-12-10
        Farad            Test Software           EZ-EMC                V1.1.4.2        N/A            N/A
    Sunol Sciences          Antenna                 JB3              A060611-3      2017-07-21     2019-07-21
      Unknown            Coaxial Cable          C-NJNJ-50             C-1000-01     2018-09-05     2019-09-05
      Unknown            Coaxial Cable          C-NJNJ-50             C-0400-02     2018-09-05     2019-09-05
      Unknown            Coaxial Cable          C-NJNJ-50             C-0530-01     2018-09-24     2019-09-24
       Sonoma              Amplifier               310N                185914       2018-10-13     2019-10-13
        R&S            Spectrum Analyzer          FSP 38               100478       2018-12-10     2019-12-10
      TDK RF             Horn Antenna           HRN-0118               130 084      2018-10-12     2021-10-12
        Mini             Pre-amplifier         ZVA-183-S+            5969001149     2018-09-05     2019-09-05
                                              UFA147-1-2362-       64639 231029-
    MICRO-COAX            Coaxial Cable                                             2019-02-24     2020-02-24
                                                  100100                 001
       Unknown            Coaxial Cable        C-2.4J2.4J-50          C-0700-02     2018-06-27     2019-06-27
      Ducommun                                                       1007726-01
                          Horn Antenna         ARH-4223-02                          2016-11-18     2019-11-18
     Technolagies                                                       1304
       Quinstar             Amplifier       QLW-18405536-JO         15964001001     2018-06-27     2019-06-27
                                            OBSF-2400-2483.5-
     E-Microwave        Band-stop Filters                          OE01601525       2018-06-16     2019-06-16
                                                   S
     Micro-tronics       High Pass Filter      HPM50111              S/N-G217       2018-06-16     2019-06-16

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data

     Environmental Conditions

              Temperature:             27.5~28.4oC
         Relative Humidity:              55~58%
            ATM Pressure:            100.4~101.2kPa

* The testing was performed by Sunny Cen& Vern Shen from 2019-05-27to2019-05-30

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table and plots.




                                                                                                    Page 19 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190523001-00B

1) 30MHz-1GHz (high Channel was the worst):
Horizontal:




                  Receiver                     Correction     Cord.
   Frequency                                                               Limit        Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                               (dBuV/m)        (dB)
                  (dBuV)                        (dB/m)      (dBuV/m)
    171.6200       44.18           peak          -12.95       31.23        43.50         12.27
    271.5300       44.00           peak          -12.01       31.99        46.00         14.01
    320.0300       48.19           peak          -10.26       37.93        46.00         8.07
    344.2800       49.08            QP            -9.58       39.50        46.00         6.50
    376.2900       47.19           peak           -8.67       38.52        46.00         7.48
    427.7000       44.38           peak           -7.85       36.53        46.00         9.47




                                                                                        Page 20 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190523001-00B

Vertical:




                  Receiver                     Correction      Cord.
   Frequency                                                                Limit        Margin
                  Reading        Detector       Factor         Amp.
     (MHz)                                                                (dBuV/m)        (dB)
                  (dBuV)                        (dB/m)       (dBuV/m)

     59.1000        41.79          peak             -20.11    21.68         40.00         18.32
    171.6200        36.73          peak             -12.95    23.78         43.50         19.72
    344.2800        42.17          peak              -9.58    32.59         46.00         13.41
    367.5600        38.76          peak              -8.88    29.88         46.00         16.12
    396.6600        37.85          peak              -8.24    29.61         46.00         16.39
    427.7000        37.82          peak              -7.85    29.97         46.00         16.03




                                                                                         Page 21 of 34


  Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190523001-00B

 2) 1-25GHz:

                  Receiver             Rx Antenna      Cable Amplifier   Corrected
Frequency                                                                              Limit      Margin
            Reading    Detector       Polar Factor       loss    Gain    Amplitude
  (MHz)                                                                              (dBμV/m)      (dB)
            (dBμV) (PK/QP/AV)         (H/V) (dB/m)      (dB)     (dB)    (dBμV/m)
                                          Low Channel: 2402 MHz
 2390.00      25.95         PK          V     24.80     3.33      0.00     54.08        74.00      19.92
 2390.00      13.60         AV          V     24.80     3.33      0.00     41.73        54.00      12.27
 4804.00      40.83         PK          V     29.71     4.58     27.36     47.76        74.00      26.24
 4804.00      33.40         AV          V     29.71     4.58     27.36     40.33        54.00      13.67
 7206.00      38.84         PK          V     33.93     5.59     27.19     51.17        74.00      22.83
 7206.00      25.06         AV          V     33.93     5.59     27.19     37.39        54.00      16.61
                                         Middle Channel: 2440 MHz
 4880.00      40.24         PK          V     29.86     4.56     27.55     47.11        74.00      26.89
 4880.00      33.24         AV          V     29.86     4.56     27.55     40.11        54.00      13.89
 7320.00      38.45         PK          V     34.11     5.69     27.26     50.99        74.00      23.01
 7320.00      27.00         AV          V     34.11     5.69     27.26     39.54        54.00      14.46
                                          High Channel: 2480 MHz
 2483.50      26.13         PK          V     24.97     3.38      0.00     54.48        74.00      19.52
 2483.50      18.56         AV          V     24.97     3.38      0.00     46.91        54.00       7.09
 4960.00      40.80         PK          V     30.02     4.58     27.37     48.03        74.00      25.97
 4960.00      33.34         AV          V     30.02     4.58     27.37     40.57        54.00      13.43
 7440.00      38.64         PK          V     34.30     5.79     27.22     51.51        74.00      22.49
 7440.00      27.14         AV          V     34.30     5.79     27.22     40.01        54.00      13.99




                                                                                          Page 22 of 34


     Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190523001-00B

    Worst plots (High Channel)
    Horizontal


Fundamental
Test with Band
Rejection Filter




                                                                          Page 23 of 34


     Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190523001-00B
    Vertical



Fundamental
Test with Band
Rejection Filter




                                                                          Page 24 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190523001-00B


FCC §15.247(a) (2) –6 dB EMISSION BANDWIDTH
Applicable Standard
According to FCC §15.247(a) (2)

Systems using digital modulation techniques may operate in the 902–928 MHz, 2400–2483.5 MHz, and
5725–5850 MHz bands. The minimum 6 dB bandwidth shall be at least 500 kHz.


Test Procedure

a) Set RBW = 100 kHz.
b) Set the video bandwidth (VBW) ≥ 3×RBW.
c) Detector = Peak.
d) Trace mode = max hold.
e) Sweep = auto couple.
f) Allow the trace to stabilize.
g) Measure the maximum width of the emission that is constrained by the frequencies associated with the
   two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB relative to the
   maximum level measured in the fundamental emission.


                                 EUT                                 Signal Analyzer


Test Equipment List and Details

                                                                     Serial       Calibration    Calibration
    Manufacturer            Description               Model
                                                                    Number           Date         Due Date

   Rohde & Schwarz        Signal Analyzer             FSIQ26      831929/005      2018-08-03      2019-08-03

       Unknown             Coaxial Cable         C-SJ00-0010       C0010/03        Each time         N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).

Test Data
     Environmental Conditions

              Temperature:                 27.7 C
         Relative Humidity:                 50 %
            ATM Pressure:                 101.1 kPa

    * The testing was performed by Blake Yang on 2019-05-28


    Test Mode: Transmitting

   Test Result: Compliance. Please refer to the following table and plots.


                                                                                                    Page 25 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                            Report No.: RDG190523001-00B

                                                                  6 dB Emission
                                               Frequency                                        Limit
                       Channel                                      Bandwidth
                                                 (MHz)                                         (MHz)
                                                                      (MHz)
                         Low                     2402                  0.729                    ≥0.5
                        Middle                   2440                  0.745                    ≥0.5
                         High                    2480                  0.741                    ≥0.5



                                                           Low Channel
                                         Delta 1 [T1]               RBW   100 kHz     RF Att      30 dB
                       Ref Lvl                          0.01 dB     VBW   300 kHz
                        20 dBm                 729.45891784 kHz     SWT    5 ms       Unit             dBm
                  20
                         0.5 dB Offset                                       1 [T1]            -5.95 dBm
                                                                                                              A
                                                                                       2.40164529 GHz
                  10
                                                                             1 [T1]             0.01 dB
                                                                                      729.45891784 kHz
                   0    D1 -0.01 dBm                                         2 [T1]           -33.49 dBm
                                                   1                         1         2.40100000 GHz
                               D2 -6.01 dBm
                 -10
                        1MAX                                                                                 1MA

                 -20



                 -302



                 -40



                 -50



                 -60



                 -70



                 -80
                       Center 2.402 GHz                      200 kHz/                         Span 2 MHz

                Date:            28.MAY.2019    16:20:30




                                                                                                                   Page 26 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                           Report No.: RDG190523001-00B


                                                      Middle Channel
                                         Delta 1 [T1]              RBW   100 kHz     RF Att      30 dB
                       Ref Lvl                        -0.11 dB     VBW   300 kHz
                        20 dBm                 745.49098196 kHz    SWT    5 ms       Unit           dBm
                  20
                         0.5 dB Offset                                      1 [T1]            -4.15 dBm
                                                                                                           A
                                                                                      2.43962926 GHz
                  10
                                                                            1 [T1]            -0.11 dB
                                                                                     745.49098196 kHz
                        D1 1.92 dBm
                   0
                                                  1                         1
                               D2 -4.08 dBm

                 -10
                        1MAX                                                                              1MA

                 -20



                 -30



                 -40



                 -50



                 -60



                 -70



                 -80
                       Center 2.44 GHz                      200 kHz/                         Span 2 MHz

                Date:            28.MAY.2019   16:22:03

                                                        High Channel
                                         Delta 1 [T1]              RBW   100 kHz     RF Att      30 dB
                       Ref Lvl                        0.01 dB      VBW   300 kHz
                        20 dBm                 741.48296593 kHz    SWT    5 ms       Unit           dBm
                  20
                         0.5 dB Offset                                      1 [T1]            -4.52 dBm
                                                                                                           A
                                                                                      2.47962926 GHz
                  10
                                                                            1 [T1]             0.01 dB
                                                                                     741.48296593 kHz
                        D1 1.51 dBm
                   0
                                                  1                         1
                               D2 -4.49 dBm

                 -10
                        1MAX                                                                              1MA

                 -20



                 -30



                 -40



                 -50



                 -60



                 -70



                 -80
                       Center 2.48 GHz                      200 kHz/                         Span 2 MHz

                Date:            28.MAY.2019   16:23:10




                                                                                                                Page 27 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190523001-00B

FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER
Applicable Standard
According to FCC §15.247(b) (3), for systems using digital modulation in the 902-928 MHz, 2400-2483.5
MHz, and 5725-5850 MHz bands: 1 Watt. As an alternative to a peak power measurement, compliance
with the one Watt limit can be based on a measurement of the maximum conducted output power.
Maximum Conducted Output Power is defined as the total transmit power delivered to all antennas and
antenna elements averaged across all symbols in the signaling alphabet when the transmitter is operating at
its maximum power control level. Power must be summed across all antennas and antenna elements. The
average must not include any time intervals during which the transmitter is off or is transmitting at a
reduced power level. If multiple modes of operation are possible (e.g., alternative modulation methods),
the maximum conducted output power is the highest total transmit power occurring in any mode.


Test Procedure
1. Place the EUT on a bench and set it in transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to test
   equipment.
3. Add a correction factor to the display.
4.

                                                                      USB Wideband
                                                                       Power Sensor
                                EUT



Test Equipment List and Details

                                                                   Serial         Calibration    Calibration
    Manufacturer           Description            Model
                                                                  Number             Date         Due Date

       Unknown            Coaxial Cable        C-SJ00-0010        C0010/03         Each time         N/A
                         USB Wideband
        Agilent                                 U2022XA         MY5417006         2018-12-10      2019-12-10
                          Power Sensor

  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                    Page 28 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190523001-00B


Test Data
     Environmental Conditions

              Temperature:             27.7 C
         Relative Humidity:             50 %
            ATM Pressure:             101.1 kPa

    * The testing was performed by Blake Yang on 2019-05-28

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table.

                                                        Max Peak
                                      Frequency      Conducted Output    Limit
                       Channel
                                        (MHz)             Power         (dBm)
                                                          (dBm)
                         Low             2402              0.15           30
                        Middle           2440              2.16           30
                         High            2480              1.79           30




                                                                                         Page 29 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190523001-00B

FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE
Applicable Standard
According to FCC§15.247(d):In any 100 kHz bandwidth outside the frequency band in which the spread
spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is
produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the
band that contains the highest level of the desired power, based on either an RF conducted or a radiated
measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If
the transmitter complies with the conducted power limits based on the use of RMS averaging over a time
interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph
shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in §15.209(a) is not
required. In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must
also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)).


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect its
   antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured
   frequency within its operating range, and make sure the instrument is operated in its linear range.
3. Set RBW to 100 kHz and VBW of spectrum analyzer to 300 kHz with a convenient frequency span
   including 100 kHz bandwidth from band edge.
4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the
   graph with marking the highest point and edge frequency.
5. Repeat above procedures until all measured frequencies were complete.


Test Equipment List and Details

                                                                   Serial         Calibration    Calibration
    Manufacturer           Description               Model
                                                                  Number             Date         Due Date

   Rohde & Schwarz       Signal Analyzer             FSIQ26      831929/005       2018-08-03      2019-08-03

       Unknown            Coaxial Cable         C-SJ00-0010       C0010/03         Each time         N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

              Temperature:                27.7 C
         Relative Humidity:                50 %
            ATM Pressure:                101.1 kPa

    * The testing was performed by Blake Yang on 2019-05-28
Test mode: Transmitting
Test Result: Compliance. Please refer to following plots.

                                                                                                    Page 30 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                                     Report No.: RDG190523001-00B


                                                    Band Edge, Left Side
                                        Marker 2 [T1]                      RBW   100 kHz       RF Att      30 dB
                       Ref Lvl                        -52.23 dBm           VBW   300 kHz
                        20 dBm                    2.40000000 GHz           SWT    5 ms         Unit           dBm
                  20
                         0.5 dB Offset                                              2 [T1]             -52.23 dBm
                                                                                                                     A
                                                                                                2.40000000 GHz
                  10
                                                                                    1 [T1]              -0.01 dBm
                                                                                                2.40202806 GHz
                                                                                           1
                   0



                 -10
                        1MAX                                                                                        1MA

                 -20 -20.01dBm



                 -30



                 -40



                 -50                                               2



                 -60



                 -70



                 -80
                       Center 2.4 GHz                        800 kHz/                                  Span 8 MHz

                Date:          28.MAY.2019       16:21:32

                                                   Band Edge, Right Side
                                        Marker 2 [T1]                      RBW   100 kHz       RF Att      30 dB
                       Ref Lvl                        -54.11 dBm           VBW   300 kHz
                        20 dBm                    2.48399098 GHz           SWT    5 ms         Unit           dBm
                  20
                         0.5 dB Offset                                              2 [T1]             -54.11 dBm
                                                                                                                     A
                                                                                                2.48399098 GHz
                  10                                        -18.51dBm
                                                                                    1 [T1]               1.49 dBm
                                             1                                                  2.48003507 GHz
                   0



                 -10
                        1MAX                                                                                        1MA

                 -20



                 -30



                 -40



                 -50
                                                                       2


                 -60



                 -70



                 -80
                       Center 2.4835 GHz                     1.4 MHz/                                 Span 14 MHz

                Date:          28.MAY.2019       16:24:18




                                                                                                                          Page 31 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                Report No.: RDG190523001-00B

FCC §15.247(e) - POWER SPECTRAL DENSITY
Applicable Standard
According to FCC§15.247(e):For digitally modulated systems, the power spectral density conducted from
the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time
interval of continuous transmission. This power spectral density shall be determined in accordance with
the provisions of paragraph (b) of this section. The same method of determining the conducted output
power shall be used to determine the power spectral density.


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT was set without connection to measurement instrument. Turn on the EUT and
   connect its antenna terminal to measurement instrument via a low loss cable. Then set it to any one
   measured frequency within its operating range, and make sure the instrument is operated in its linear
   range.
3. Set the RBW = 3 kHz, VBW = 10 kHz, Set the span to 1.5 times the DTS bandwidth.
4. Use the peak marker function to determine the maximum amplitude level.


Test Equipment List and Details

                                                                      Serial       Calibration   Calibration
     Manufacturer            Description               Model
                                                                     Number           Date        Due Date

   Rohde & Schwarz         Signal Analyzer             FSIQ26       831929/005     2018-08-03     2019-08-03

        Unknown             Coaxial Cable         C-SJ00-0010        C0010/03       Each time        N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

               Temperature:                 27.7 C
         Relative Humidity:                  50 %
            ATM Pressure:                  101.1 kPa

     * The testing was performed by Blake Yang on 2019-05-28


Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table and plots




                                                                                                    Page 32 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                        Report No.: RDG190523001-00B

                                                               Power Spectral
                                             Frequency                                 Limit
                         Channel                                  Density
                                               (MHz)                                (dBm/3kHz)
                                                                (dBm/3kHz)
                           Low                  2402               -15.60                  ≤8
                          Middle                2440               -13.55                  ≤8
                          High                  2480               -13.97                  ≤8



                                     Power Spectral Density, Low Channel
                                       Marker 1 [T1]            RBW    3 kHz      RF Att      30 dB
                       Ref Lvl                    -15.60 dBm    VBW   10 kHz
                        20 dBm                2.40198576 GHz    SWT   310 ms      Unit           dBm
                  20
                         0.5 dB Offset                                   1 [T1]           -15.60 dBm
                                                                                                        A
                                                                                   2.40198576 GHz
                  10



                   0



                 -10
                        1MAX                               1                                           1MA

                 -20



                 -30



                 -40



                 -50



                 -60



                 -70



                 -80
                       Center 2.402 GHz                 109.35 kHz/               Span 1.0935 MHz

                Date:          28.MAY.2019   16:21:09




                                                                                                             Page 33 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                           Report No.: RDG190523001-00B


                                    Power Spectral Density, Middle Channel
                                       Marker 1 [T1]               RBW    3 kHz      RF Att      30 dB
                       Ref Lvl                    -13.55 dBm       VBW   10 kHz
                        20 dBm                2.43987571 GHz       SWT   320 ms      Unit           dBm
                  20
                         0.5 dB Offset                                      1 [T1]           -13.55 dBm
                                                                                                           A
                                                                                      2.43987571 GHz
                  10



                   0



                 -10                                1
                        1MAX                                                                              1MA

                 -20



                 -30



                 -40



                 -50



                 -60



                 -70



                 -80
                       Center 2.44 GHz                  111.75 kHz/                  Span 1.1175 MHz

                Date:          28.MAY.2019   16:22:41

                                     Power Spectral Density, High Channel
                                       Marker 1 [T1]               RBW    3 kHz      RF Att      30 dB
                       Ref Lvl                    -13.97 dBm       VBW   10 kHz
                        20 dBm                2.48000334 GHz       SWT   310 ms      Unit           dBm
                  20
                         0.5 dB Offset                                      1 [T1]           -13.97 dBm
                                                                                                           A
                                                                                      2.48000334 GHz
                  10



                   0



                 -10
                                                               1
                        1MAX                                                                              1MA

                 -20



                 -30



                 -40



                 -50



                 -60



                 -70



                 -80
                       Center 2.48 GHz                  111.15 kHz/                  Span 1.1115 MHz

                Date:          28.MAY.2019   16:23:51



                                         ***** END OF REPORT *****

                                                                                                                Page 34 of 34



Document Created: 2019-06-28 19:56:30
Document Modified: 2019-06-28 19:56:30

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC