Test Report

FCC ID: 2AMH2-BH356A

Test Report

Download: PDF
FCCID_4392017

                                           FCC PART 15.247
                                               TEST REPORT

                                                              For

                MPOW TECHNOLOGY CO.,LIMITED
       RM 603, 6/F, HANG PONT COMM BLDG 31 TONKIN ST CHEUNG SHA WAN KL HK China



                                         FCC ID: 2AMH2-BH356A


            Report Type:                                 Product Name:
            Original Report                              Neckband Wire less Earphones


                  Report Number:           RDG190709001-00C


                      Report Date:         2019-07-27


                                           Jerry Zhang
                     Reviewed By:          EMC Manager

                                           Bay Area Compliance Laboratories Corp. (Dongguan)
                 Test Laboratory:          No.69 Pulongcun, Puxinhu Industry Area,
                                           Tangxia, Dongguan, Guangdong, China
                                           Tel: +86-769-86858888
                                           Fax: +86-769-86858891
                                           www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be
used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal
Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”.


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                          Report No.: RDG190709001-00C




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................4
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................4
 OBJECTIVE ...................................................................................................................................................................4
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................4
 TEST METHODOLOGY ..................................................................................................................................................4
 MEASUREMENT UNCERTAINTY ....................................................................................................................................5
 TEST FACILITY .............................................................................................................................................................5
SYSTEM TEST CONFIGURATION ..........................................................................................................................6
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................6
  EQUIPMENT MODIFICATIONS .......................................................................................................................................6
  EUT EXERCISE SOFTWARE ..........................................................................................................................................6
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................7
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................7
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................8
SUMMARY OF TEST RESULTS ...............................................................................................................................9
FCC §15.247 (i) & §1.1310 & §2.1093- RF EXPOSURE..........................................................................................10
  APPLICABLE STANDARD ............................................................................................................................................10
FCC §15.203 - ANTENNA REQUIREMENT...........................................................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  ANTENNA INFORMATION AND CONNECTOR CONSTRUCTION.....................................................................................11
FCC §15.207 (a)– AC LINE CONDUCTED EMISSIONS ......................................................................................12
  APPLICABLE STANDARD ............................................................................................................................................12
  EUT SETUP ................................................................................................................................................................12
  EMI TEST RECEIVER SETUP .......................................................................................................................................12
  TEST PROCEDURE ......................................................................................................................................................12
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................13
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................13
  TEST DATA ................................................................................................................................................................13
FCC §15.209, §15.205, §15.247(d) - SPURIOUS EMISSIONS .................................................................................16
  APPLICABLE STANDARD ............................................................................................................................................16
  EUT SETUP ................................................................................................................................................................16
  EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP ..............................................................................................17
  TEST PROCEDURE ......................................................................................................................................................17
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................17
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................18
  TEST DATA ................................................................................................................................................................18
FCC §15.247(a) (2) –6 dB EMISSION BANDWIDTH .............................................................................................24
  APPLICABLE STANDARD ............................................................................................................................................24
  TEST PROCEDURE ......................................................................................................................................................24
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................24
  TEST DATA ................................................................................................................................................................24
FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER ......................................................27
  APPLICABLE STANDARD ............................................................................................................................................27
  TEST PROCEDURE ......................................................................................................................................................27

                                                                                                                                                            Page 2 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                           Report No.: RDG190709001-00C


    TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................27
    TEST DATA ................................................................................................................................................................28
FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE .......................................................29
  APPLICABLE STANDARD ............................................................................................................................................29
  TEST PROCEDURE ......................................................................................................................................................29
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................29
  TEST DATA ................................................................................................................................................................29
FCC §15.247(e) - POWER SPECTRAL DENSITY .................................................................................................31
  APPLICABLE STANDARD ............................................................................................................................................31
  TEST PROCEDURE ......................................................................................................................................................31
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................31
  TEST DATA ................................................................................................................................................................31




                                                                                                                                                             Page 3 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG190709001-00C

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

                    EUT Name:       Neckband Wireless Earphones
                    EUT Model:      BH356A
           Operation Frequency:     2402-2480 MHz
         Maximum Output Power
                                    2.02 dBm
                   (Conducted):
              Modulation Type:      GFSK
            Rated Input Voltage:    3.7 VDC from battery or 5VDC from USB port
            External Dimension:     330mm(L)*127mm(W)*26mm(H)
                 Serial Number:     190709001
            EUT Received Date:      2019-07-09


Objective
This report is prepared on behalf of MPOW TECHNOLOGY CO.,LIMITED in accordance with Part 2,
Subpart J, Part 15, Subparts A and C of the Federal Communications Commission’s rules

The tests were performed in order to determine the compliance of the EUT with FCC Rules Part 15-
Subpart C, section 15.203, 15.205, 15.207, 15.209, 15.247 rules.


Related Submittal(s)/Grant(s)
FCC Part 15C DSS submissions with FCC ID: 2AMH2-BH356A.


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices and KDB 558074 D01
DTS Meas Guidance v05r02.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).




                                                                                             Page 4 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190709001-00C

Measurement Uncertainty
            Parameter                                      Measurement Uncertainty
    Occupied Channel Bandwidth                                     ±5 %
    RF output power, conducted                                    ±0.61dB
  Power Spectral Density, conducted                               ±0.61 dB
                                          30M~200MHz: 4.55 dB,200M~1GHz: 5.92 dB,1G~6GHz: 4.98 dB,
    Unwanted Emissions, radiated
                                            6G~18GHz: 5.89 dB,18G~26.5G:5.47 dB,26.5G~40G:5.63 dB
   Unwanted Emissions, conducted                                    ±1.5 dB
           Temperature                                                ±1℃
             Humidity                                                 ±5%
   DC and low frequency voltages                                     ±0.4%
            Duty Cycle                                                 1%
 AC Power Lines Conducted Emission                        3.12 dB (150 kHz to 30 MHz)


Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the
FCC Public Access Link (PAL) database, FCC Registration No. : 897218, the FCC Designation No. :
CN1220.

The lab has been recognized by Innovation, Science and Economic Development Canada to test to
Canadian radio equipment requirements, the CAB identifier : CN0022.




                                                                                             Page 5 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190709001-00C

SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in engineering mode.
For Bluetooth LE mode, 40 channels are provided for testing:

                                    Frequency                                     Frequency
                Channel                                       Channel
                                      (MHz)                                         (MHz)
                   0                   2402                     20                   2442
                   1                   2404                     …                     …
                   …                    …                       …                     …
                   …                    …                       …                     …
                    ..                 …                        38                   2478
                   19                 2440                      39                   2480

EUT was tested with channel 0, 19 and 39.


Equipment Modifications
No modification was made to the EUT tested.


EUT Exercise Software
The software ' BOB.exe' was used for testing, which was provided by manufacturer and the maximum
power was configured as below table:

                     Channel             Frequency (MHz)                 Power level
                      Low                      2402                        Default
                     Middle                    2440                        Default
                      High                     2480                        Default

The duty cycle as below:

                            Ton                     Ton+off             Duty Cycle
                           (ms)                     (ms)                   (%)
                           0.413                    0.629                 65.66




                                                                                              Page 6 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                     Report No.: RDG190709001-00C




Local Support Equipment List and Details

       Manufacturer           Description              Model              Serial Number
         Unknown                  Adapter        PS10J050K2000TU                /



Support Cable List and Details

         Cable           Shielding                     Length
                                        Ferrite Core               From Port              To
       Description         Type                         (m)
       USB Cable            Yes             No           0.5        Adapter           EUT




                                                                                          Page 7 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)              Report No.: RDG190709001-00C

Block Diagram of Test Setup

AC Line Conducted Emission:
                                                                                           LISN1



                                                                 10cm
                                                         EUT             Adapter




                                                                                      1.0 Meter
       Non-Conductive Table 80
       cm above Ground Plane

                                             1.5 Meter

Radiation Spurious Emission:




                                                                                   Page 8 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190709001-00C


SUMMARY OF TEST RESULTS

               FCC Rules                            Description of Test               Result

       FCC §15.247 (i) & §1.1310 &
                                                       RF Exposure                  Compliance
                §2.1093
                §15.203                         Antenna Requirement                 Compliance

               §15.207 (a)                  AC Line Conducted Emissions             Compliance
            §15.205, §15.209,
                                                    Spurious Emissions              Compliance
               §15.247(d)
             §15.247 (a)(2)                          6 dB Bandwidth                 Compliance

             §15.247(b)(3)                Maximum Conducted Output Power            Compliance

               §15.247(d)             100 kHz Bandwidth of Frequency Band Edge      Compliance

               §15.247(e)                       Power Spectral Density              Compliance




                                                                                               Page 9 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190709001-00C

FCC §15.247 (i) & §1.1310 & §2.1093- RF EXPOSURE
Applicable Standard
According to§15.247(i) and §1.1310, systems operating under the provisions of this section shall be
operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of
the Commission’s guideline.

According to KDB447498 D01 General RF Exposure Guidance v06:

The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50
mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
        • f(GHz) is the RF channel transmit frequency in GHz
        • Power and distance are rounded to the nearest mW and mm before calculation
        • The result is rounded to one decimal place for comparison
        • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below

The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5
mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion.


Measurement Result

The max conducted power including tune-up tolerance is 3 dBm (2 mW).
[(max. power of channel, mW)/(min. test separation distance, mm)][√f(GHz)]
=2/5*(√2.480) = 0.6< 3.0

So the stand-alone SAR evaluation is not necessary.




                                                                                               Page 10 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG190709001-00C

FCC §15.203 - ANTENNA REQUIREMENT
Applicable Standard
According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
furnished by the responsible party shall be used with the device. The use of a permanently attached
antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered
sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a
broken antenna can be replaced by the user, but the user of a standard antenna jack or electrical connector
is prohibited. The structure and application of the EUT were analyzed to determine compliance with
section §15.203 of the rules. §15.203 state that the subject device must meet the following criteria:

a. Antenna must be permanently attached to the unit.
b. Antenna must use a unique type of connector to attach to the EUT.
c. Unit must be professionally installed, and installer shall be responsible for verifying that the correct
   antenna is employed with the unit.


Antenna Information And Connector Construction
The EUT has one internal antenna arrangement for BT, and the antenna gain is 0.8 dBi, fulfill the
requirement of this section. Please refer to the EUT photos.

Result: Compliance.




                                                                                                 Page 11 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190709001-00C

FCC §15.207 (a)– AC LINE CONDUCTED EMISSIONS
Applicable Standard
FCC§15.207(a)


EUT Setup




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.207.

The spacing between the peripherals was 10 cm.

The adapter was connected to the main lisn with a 120 V/60 Hz AC power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                      IF B/W
                              150 kHz – 30 MHz                      9 kHz



Test Procedure

During the conducted emission test, the adapter was connected to the first LISN.


                                                                                              Page 12 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RDG190709001-00C

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.


Corrected Amplitude & Margin Calculation
The basic equation is as follows:

VC = VR + AC + VDF
Cf = AC + VDF

Herein,
VC (cord. Reading): corrected voltage amplitude
VR: reading voltage amplitude
Ac: attenuation caused by cable loss
VDF: voltage division factor of AMN
Cf: Correction Factor

The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation
for margin calculation is as follows:

                                    Margin = Limit – Corrected Amplitude


Test Equipment List and Details

                                                                     Serial         Calibration   Calibration
      Manufacturer              Description           Model
                                                                    Number             Date        Due Date
         Unknown                Coaxial Cable      C-NJNJ-50        C-0200-01       2018-09-05     2019-09-05
           R&S                  Test Software        EMC32        Version8.53.0        N/A            N/A
           R&S              Two-line V-network      ENV 216          101614         2018-12-10     2019-12-10
           R&S               EMI Test Receiver        ESPI           100120         2019-05-09     2020-05-09

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).

Test Data
     Environmental Conditions

               Temperature:             28.9 oC
          Relative Humidity:             48%
             ATM Pressure:              99.7kPa
                     Test by:           Lily Xie
                   Test Date:         2019-07-24
Test Result: Compliance
Test Mode: Charging

                                                                                                    Page 13 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                            Report No.: RDG190709001-00C


   AC120V, 60 Hz, Line:


                           80

                           70
                                                                                                       Quasi-Peak Limit
                           60
                                                                                                          Average Limit
                           50
           Level in dBμ




                           40

                           30

                           20

                           10

                           0
                           150k      300   400 500   800 1M           2M   3M     4M 5M 6    8 10M           20M     30M

                                                                Frequency in Hz




                Frequency              QuasiPeak        Bandwidth                    Corr.    Margin           Limit
                                                                           Line
                  (MHz)                 (dBμV)            (kHz)                      (dB)      (dB)           (dBμV)
                 0.239440                 34.6            9.000            L1        10.4      27.5             62.1
                      0.332508              31.4              9.000        L1        10.1       28.0            59.4
                      0.569057              31.2              9.000        L1         9.8       24.8            56.0
                      0.935889              25.5              9.000        L1         9.8       30.5            56.0
                      1.601690              23.9              9.000        L1         9.7       32.1            56.0
                      3.694655              23.4              9.000        L1         9.8       32.6            56.0

                 Frequency                 Average      Bandwidth                    Corr.    Margin           Limit
                                                                           Line
                   (MHz)                   (dBμV)         (kHz)                      (dB)      (dB)           (dBμV)
                  0.426418                   21.5         9.000             L1        9.9      25.8             47.3
                          0.610106          24.8              9.000         L1        9.8       21.2            46.0
                          0.926623          21.3              9.000         L1        9.8       24.7            46.0
                          1.617707          19.5              9.000         L1        9.7       26.5            46.0
                          2.909785          19.4              9.000         L1        9.8       26.6            46.0
                          3.658074          18.3              9.000         L1        9.8       27.7            46.0




                                                                                                                          Page 14 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                            Report No.: RDG190709001-00C

   AC120V, 60 Hz, Neutral:


                           80

                           70
                                                                                                       Quasi-Peak Limit
                           60
                                                                                                          Average Limit
                           50
           Level in dBμ




                           40

                           30

                           20

                           10

                           0
                           150k      300   400 500   800 1M           2M   3M     4M 5M 6    8 10M           20M     30M

                                                                Frequency in Hz




                Frequency              QuasiPeak        Bandwidth                    Corr.    Margin           Limit
                                                                           Line
                  (MHz)                 (dBμV)            (kHz)                      (dB)      (dB)           (dBμV)
                 0.227819                 33.8            9.000             N        10.4      28.7             62.5
                      0.342583              28.4              9.000         N        10.0       30.7            59.1
                      0.616207              29.9              9.000         N         9.8       26.1            56.0
                      1.013434              28.3              9.000         N         9.8       27.7            56.0
                      1.617707              25.1              9.000         N         9.8       30.9            56.0
                      2.246494              24.8              9.000         N         9.8       31.2            56.0

                 Frequency                 Average      Bandwidth                    Corr.    Margin           Limit
                                                                           Line
                   (MHz)                   (dBμV)         (kHz)                      (dB)      (dB)           (dBμV)
                  0.426418                   23.8         9.000             N         9.9      23.5             47.3
                          0.434989          25.1              9.000         N         9.9       22.1            47.2
                          0.610106          29.0              9.000         N         9.8       17.0            46.0
                          1.013434          25.3              9.000         N         9.8       20.7            46.0
                          1.700226          22.2              9.000         N         9.8       23.8            46.0
                          2.968272          20.9              9.000         N         9.8       25.1            46.0




                                                                                                                          Page 15 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190709001-00C


FCC §15.209, §15.205, §15.247(d) - SPURIOUS EMISSIONS
Applicable Standard
FCC §15.247 (d); §15.209; §15.205

EUT Setup
Below 1GHz:




Above 1GHz:




The radiated emission tests were performed in the 3 meters chamber test site A for the range 30MHz to
1GHz and the 3 meters chamber B test site for above 1GHz, using the setup accordance with the ANSI
C63.10-2013. The specification used was the FCC 15.209, and FCC 15.247 limits.

The spacing between the peripherals was 10 cm.




                                                                                            Page 16 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190709001-00C

EMI Test Receiver & Spectrum Analyzer Setup

The system was investigated from 30 MHz to 25 GHz.

During the radiated emission test, the EMI test receiver & Spectrum Analyzer Setup were set with the
following configurations:

30MHz-1000MHz:

                    Measurement             RBW            Video B/W       IF B/W
                        QP                 120 kHz          300 kHz        120kHz

1GHz- 25GHz:

                       Measurement            Duty cycle       RBW         Video B/W
                           PK                    Any           1MHz          3 MHz
                                                >98%           1MHz          10 Hz
                            AV
                                                <98%           1MHz            1/T

Note: T is minimum transmission duration

If the maximized peak measured value complies with under the QP/Average limit more than 6dB, then it is
unnecessary to perform an QP/Average measurement.


Test Procedure

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

Data was recorded in Quasi-peak detection mode for frequency range of 30 MHz-1 GHz, peak and
Average detection modes for frequencies above 1 GHz.


Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit –Corrected Amplitude




                                                                                             Page 17 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                  Report No.: RDG190709001-00C

Test Equipment List and Details

                                                                        Serial        Calibration   Calibration
    Manufacturer            Description             Model
                                                                       Number            Date        Due Date
         R&S           EMI Test Receiver             ESR3               102453        2019-06-26    2020-06-26
        Farad            Test Software              EZ-EMC             V1.1.4.2          N/A           N/A
    Sunol Sciences          Antenna                   JB3             A060611-1       2017-11-10    2020-11-10
       Unknown           Coaxial Cable             C-NJNJ-50          C-0400-01       2018-09-05    2019-09-05
       Unknown           Coaxial Cable             C-NJNJ-50          C-0075-01       2018-09-05    2019-09-05
       Unknown           Coaxial Cable             C-NJNJ-50          C-1400-01       2019-05-06    2020-05-06
          HP               Amplifier                 8447D           2727A05902       2018-09-05    2019-09-05
        Agilent        Spectrum Analyzer            E4440A           SG43360054       2019-05-09    2020-05-09
    ETS-Lindgren         Horn Antenna                 3115            000 527 35      2018-10-12    2021-10-12
      Ducommun                                                       1007726-01
                           Horn Antenna          ARH-4223-02                          2016-11-18    2019-11-18
     Technolagies                                                        1304
       Unknown             Coaxial Cable           C-SJSJ-50          C-0800-01       2018-09-05    2019-09-05
                                                AFS42-00101800-
        MITEQ                Amplifier                                   2001271      2018-09-05    2019-09-05
                                                    25-S-42
       Quinstar              Amplifier         QLW-18405536-JO       15964001001      2019-06-27    2020-06-27
                                               OBSF-2400-2483.5-
     E-Microwave          Band-stop Filters                          OE01601525       2019-06-16    2020-06-16
                                                       S
     Micro-tronics        High Pass Filter        HPM50111            S/N-G217        2019-06-16    2020-06-16

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data

     Environmental Conditions

                              Radiated emissions       Radiated emissions
            Test Items:
                                below 1GHz                above 1GHz
         Temperature:                25oC                     27oC
              Relative
                                     51%                       50%
            Humidity:
        ATM Pressure:              100.2kPa                  100.3kPa
              Test by:             Tyler Pan                 Lucy Lu
            Test Date:            2019-07-19                2019-07-17

      Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table and plots.




                                                                                                     Page 18 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190709001-00C

1) 30MHz-1GHz (High Channel was the worst):
Horizontal:




                  Receiver                     Correction     Cord.
   Frequency                                                               Limit        Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                               (dBuV/m)        (dB)
                  (dBuV)                        (dB/m)      (dBuV/m)
     30.0000       26.57           peak            1.72       28.29        40.00         11.71
     91.1100       35.66           peak          -11.09       24.57        43.50         18.93
    361.7400       27.81           peak           -2.80       25.01        46.00         20.99
    565.4400       26.62           peak            0.92       27.54        46.00         18.46
    902.0300       35.13           peak            0.14       35.27        46.00         10.73
    981.5700       32.16           peak            1.29       33.45        54.00         20.55




                                                                                        Page 19 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190709001-00C

Vertical:




                  Receiver                     Correction     Cord.
   Frequency                                                               Limit        Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                               (dBuV/m)        (dB)
                  (dBuV)                        (dB/m)      (dBuV/m)
     30.0000        27.41          peak              1.72    29.13         40.00         10.87
    121.1800        26.13          peak             -4.68    21.45         43.50         22.05
    361.7400        27.63          peak             -2.80    24.83         46.00         21.17
    640.1300        27.73          peak              2.27    30.00         46.00         16.00
    903.9700        34.35          peak              0.16    34.51         46.00         11.49
    981.5700        33.05          peak              1.29    34.34         54.00         19.66




                                                                                        Page 20 of 33


  Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190709001-00C

 2) 1-25GHz:

                  Receiver             Rx Antenna      Cable Amplifier   Corrected
Frequency                                                                              Limit      Margin
            Reading    Detector       Polar Factor       loss    Gain    Amplitude
  (MHz)                                                                              (dBμV/m)      (dB)
            (dBμV) (PK/QP/AV)         (H/V) (dB/m)      (dB)     (dB)    (dBμV/m)
                                          Low Channel: 2402 MHz
 2402.00      67.48         PK          H     28.10     1.80      0.00     97.38         N/A        N/A
 2402.00      66.83         AV          H     28.10     1.80      0.00     96.73         N/A        N/A
 2402.00      62.94         PK          V     28.10     1.80      0.00     92.84         N/A        N/A
 2402.00      62.10         AV          V     28.10     1.80      0.00     92.00         N/A        N/A
 2390.00      33.92         PK          H     28.08     1.80      0.00     63.80        74.00      10.20
 2390.00      15.35         AV          H     28.08     1.80      0.00     45.23        54.00       8.77
 4804.00      47.16         PK          H     32.91     3.17     37.20     46.04        74.00      27.96
 4804.00      35.79         AV          H     32.91     3.17     37.20     34.67        54.00      19.33
 7206.00      45.11         PK          H     35.74     4.82     37.23     48.44        74.00      25.56
 7206.00      32.85         AV          H     35.74     4.82     37.23     36.18        54.00      17.82
                                         Middle Channel: 2440 MHz
 2440.00      68.53         PK          H     28.18     1.82      0.00     98.53         N/A        N/A
 2440.00      67.74         AV          H     28.18     1.82      0.00     97.74         N/A        N/A
 2440.00      53.04         PK          V     28.18     1.82      0.00     83.04         N/A        N/A
 2440.00      52.11         AV          V     28.18     1.82      0.00     82.11         N/A        N/A
 4880.00      47.24         PK          H     33.06     3.27     37.21     46.36        74.00      27.64
 4880.00      35.45         AV          H     33.06     3.27     37.21     34.57        54.00      19.43
 7320.00      45.25         PK          H     36.03     4.62     37.37     48.53        74.00      25.47
 7320.00      33.42         AV          H     36.03     4.62     37.37     36.70        54.00      17.30
                                          High Channel: 2480 MHz
 2480.00      69.51         PK          H     28.26     1.84      0.00     99.61         N/A        N/A
 2480.00      68.28         AV          H     28.26     1.84      0.00     98.38         N/A        N/A
 2480.00      65.04         PK          V     28.26     1.84      0.00     95.14         N/A        N/A
 2480.00      64.14         AV          V     28.26     1.84      0.00     94.24         N/A        N/A
 2483.50      26.06         PK          H     28.27     1.84      0.00     56.17        74.00      17.83
 2483.50      18.34         AV          H     28.27     1.84      0.00     48.45        54.00       5.55
 4960.00      47.34         PK          H     33.22     3.23     37.25     46.54        74.00      27.46
 4960.00      35.14         AV          H     33.22     3.23     37.25     34.34        54.00      19.66
 7440.00      46.24         PK          H     36.34     4.41     37.52     49.47        74.00      24.53
 7440.00      34.11         AV          H     36.34     4.41     37.52     37.34        54.00      16.66




                                                                                          Page 21 of 33


     Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190709001-00C

    Worst plots (High Channel)
    Horizontal


Fundamental
Test with Band
Rejection Filter




                                                                          Page 22 of 33


     Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190709001-00C

    Vertical



Fundamental
Test with Band
Rejection Filter




                                                                          Page 23 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190709001-00C


FCC §15.247(a) (2) –6 dB EMISSION BANDWIDTH
Applicable Standard
According to FCC §15.247(a) (2)

Systems using digital modulation techniques may operate in the 902–928 MHz, 2400–2483.5 MHz, and
5725–5850 MHz bands. The minimum 6 dB bandwidth shall be at least 500 kHz.


Test Procedure

a) Set RBW = 100 kHz.
b) Set the video bandwidth (VBW) ≥ 3×RBW.
c) Detector = Peak.
d) Trace mode = max hold.
e) Sweep = auto couple.
f) Allow the trace to stabilize.
g) Measure the maximum width of the emission that is constrained by the frequencies associated with the
   two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB relative to the
   maximum level measured in the fundamental emission.


                                 EUT                                 Signal Analyzer


Test Equipment List and Details

                                                                     Serial       Calibration    Calibration
     Manufacturer           Description                Model
                                                                    Number           Date         Due Date

          R&S            Spectrum Analyzer           FSU 26          200256       2019-05-09      2020-05-09

       Unknown               Attenuator                3dB           3dB-1         Each time         N/A

       Unknown             Coaxial Cable         C-SJ00-0010       C0010/04        Each time         N/A
  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

               Temperature:                25.1 C
         Relative Humidity:                  53 %
            ATM Pressure:                  100.3 kPa
                    Test by:               Elena Lei
                  Test Date:              2019-07-22

Test Mode: Transmitting
   Test Result: Compliance. Please refer to the following table and plots.

                                                                                                    Page 24 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                                      Report No.: RDG190709001-00C


                                                                           6 dB Emission
                                                   Frequency                                              Limit
                          Channel                                            Bandwidth
                                                     (MHz)                                               (MHz)
                                                                               (MHz)
                            Low                        2402                     0.701                     ≥0.5
                           Middle                      2440                     0.697                     ≥0.5
                            High                       2480                     0.697                     ≥0.5


                                                                Low Channel
                                                                     * RBW 100 kHz     Delta 1 [T1 ]
                                                                     * VBW 300 kHz                 0.36 dB
                     Ref    25 dBm              * Att   25 dB         SWT 2.5 ms          701.402805612 kHz

                           Offset    5 dB                                              Marker 1 [T1 ]
                     20                                                                           -5.17 dBm
                                                                                            2.401637275 GHz    A

              1 PK   10
              MAXH
                                                                                                               LVL
                     0
                              D1 0.94 dBm
                                                   1                               1
                                    D2 -5.06 dBm

                     -10



                     -20



                     -30                                                                                       3DB


                     -40



                     -50



                     -60



                     -70


                     Center   2.402 GHz                         200 kHz/                        Span   2 MHz




              Date: 22.JUL.2019      14:14:14




                                                                                                                        Page 25 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                                      Report No.: RDG190709001-00C


                                                           Middle Channel
                                                                     * RBW 100 kHz     Delta 1 [T1 ]
                                                                     * VBW 300 kHz                 0.18 dB
                     Ref    25 dBm              * Att   25 dB         SWT 2.5 ms          697.394789580 kHz

                           Offset    5 dB                                              Marker 1 [T1 ]
                     20                                                                           -4.72 dBm
                                                                                            2.439641283 GHz    A

              1 PK   10
              MAXH
                                                                                                               LVL
                              D1 1.27 dBm
                     0
                                                   1                               1
                                    D2 -4.73 dBm

                     -10



                     -20



                     -30                                                                                       3DB


                     -40



                     -50



                     -60



                     -70


                     Center   2.44 GHz                          200 kHz/                        Span   2 MHz




              Date: 22.JUL.2019      14:17:28



                                                            High Channel
                                                                     * RBW 100 kHz     Delta 1 [T1 ]
                                                                     * VBW 300 kHz                 0.35 dB
                     Ref    25 dBm              * Att   25 dB         SWT 2.5 ms          697.394789579 kHz

                           Offset    5 dB                                              Marker 1 [T1 ]
                     20                                                                           -5.23 dBm
                                                                                            2.479637275 GHz    A

              1 PK   10
              MAXH
                                                                                                               LVL
                     0        D1 0.82 dBm
                                                   1                               1
                                    D2 -5.18 dBm

                     -10



                     -20



                     -30                                                                                       3DB


                     -40



                     -50



                     -60



                     -70


                     Center   2.48 GHz                          200 kHz/                        Span   2 MHz




              Date: 22.JUL.2019      14:15:42




                                                                                                                        Page 26 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190709001-00C

FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER
Applicable Standard
According to FCC §15.247(b) (3), for systems using digital modulation in the 902-928 MHz, 2400-2483.5
MHz, and 5725-5850 MHz bands: 1 Watt. As an alternative to a peak power measurement, compliance
with the one Watt limit can be based on a measurement of the maximum conducted output power.
Maximum Conducted Output Power is defined as the total transmit power delivered to all antennas and
antenna elements averaged across all symbols in the signaling alphabet when the transmitter is operating at
its maximum power control level. Power must be summed across all antennas and antenna elements. The
average must not include any time intervals during which the transmitter is off or is transmitting at a
reduced power level. If multiple modes of operation are possible (e.g., alternative modulation methods),
the maximum conducted output power is the highest total transmit power occurring in any mode.


Test Procedure
1. Place the EUT on a bench and set it in transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to test
   equipment.
3. Add a correction factor to the display.
4.

                                                                      USB Wideband
                                                                       Power Sensor
                                EUT



Test Equipment List and Details

                                                                   Serial         Calibration    Calibration
    Manufacturer           Description            Model
                                                                  Number             Date         Due Date
                         USB Wideband
        Agilent                                 U2022XA         MY5417006         2018-12-10      2019-12-10
                          Power Sensor
       Unknown            Coaxial Cable        C-SJ00-0010        C0010/05         Each time         N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                    Page 27 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190709001-00C


Test Data
     Environmental Conditions

              Temperature:             28.1 C
         Relative Humidity:             46 %
            ATM Pressure:             100.6 kPa
                    Test by:          Elena Lei
                  Test Date:         2019-07-22

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table.

                                                        Max Peak
                                      Frequency      Conducted Output    Limit
                       Channel
                                        (MHz)             Power         (dBm)
                                                          (dBm)
                         Low             2402              1.59           30
                        Middle           2440              2.02           30
                         High            2480              1.55           30




                                                                                         Page 28 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190709001-00C

FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE
Applicable Standard
According to FCC§15.247(d):In any 100 kHz bandwidth outside the frequency band in which the spread
spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is
produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the
band that contains the highest level of the desired power, based on either an RF conducted or a radiated
measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If
the transmitter complies with the conducted power limits based on the use of RMS averaging over a time
interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph
shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in §15.209(a) is not
required. In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must
also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)).


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect its
   antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured
   frequency within its operating range, and make sure the instrument is operated in its linear range.
3. Set RBW to 100 kHz and VBW of spectrum analyzer to 300 kHz with a convenient frequency span
   including 100 kHz bandwidth from band edge.
4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the
   graph with marking the highest point and edge frequency.
5. Repeat above procedures until all measured frequencies were complete.


Test Equipment List and Details

                                                                   Serial         Calibration    Calibration
    Manufacturer           Description                Model
                                                                  Number             Date         Due Date

         R&S            Spectrum Analyzer           FSU 26         200256         2019-05-09      2020-05-09

       Unknown              Attenuator                3dB           3dB-1          Each time         N/A

       Unknown            Coaxial Cable         C-SJ00-0010       C0010/04         Each time         N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).

Test Data
     Environmental Conditions

              Temperature:                28.1 C
         Relative Humidity:                 46 %
            ATM Pressure:                 100.6 kPa
                    Test by:              Elena Lei
                  Test Date:             2019-07-22

                                                                                                    Page 29 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                                           Report No.: RDG190709001-00C

Test mode: Transmitting
Test Result: Compliance. Please refer to following plots.
                                                         Band Edge, Left Side
                                                                        * RBW 100 kHz       Marker 2 [T1 ]
                                                                        * VBW 300 kHz                 -35.45 dBm
                      Ref    25 dBm              * Att   25 dB           SWT 5 ms                2.400000000 GHz

                            Offset    5 dB                                                  Marker 1 [T1 ]
                      20                                                                                0.93 dBm
                                                                                                 2.401728000 GHz     A

               1 PK   10
               MAXH
                                                                                        1                            LVL
                      0



                      -10


                      -19.07dBm
                      -20



                      -30                                                                                            3DB
                                                                    2


                      -40



                      -50



                      -60



                      -70


                      Center   2.4 GHz                           800 kHz/                            Span    8 MHz




              Date: 22.JUL.2019       14:15:19



                                                         Band Edge, Right Side
                                                                        * RBW 100 kHz       Marker 2 [T1 ]
                                                                        * VBW 300 kHz                 -42.01 dBm
                      Ref    25 dBm              * Att   25 dB           SWT 5 ms                2.483668000 GHz

                            Offset    5 dB                                                  Marker 1 [T1 ]
                      20                                     -19.21dBm                                  0.79 dBm
                                                                                                 2.479720000 GHz     A

               1 PK   10
               MAXH
                                             1                                                                       LVL
                      0



                      -10



                      -20



                      -30                                                                                            3DB


                                                                     2
                      -40



                      -50



                      -60



                      -70


                      Center   2.4835 GHz                        1.4 MHz/                           Span    14 MHz




              Date: 22.JUL.2019       14:17:01




                                                                                                                             Page 30 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RDG190709001-00C

FCC §15.247(e) - POWER SPECTRAL DENSITY
Applicable Standard
According to FCC§15.247(e):For digitally modulated systems, the power spectral density conducted from
the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time
interval of continuous transmission. This power spectral density shall be determined in accordance with
the provisions of paragraph (b) of this section. The same method of determining the conducted output
power shall be used to determine the power spectral density.


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT was set without connection to measurement instrument. Turn on the EUT and
   connect its antenna terminal to measurement instrument via a low loss cable. Then set it to any one
   measured frequency within its operating range, and make sure the instrument is operated in its linear
   range.
3. Set the RBW = 3 kHz, VBW = 10 kHz, Set the span to 1.5 times the DTS bandwidth.
4. Use the peak marker function to determine the maximum amplitude level.


Test Equipment List and Details

                                                                      Serial        Calibration   Calibration
     Manufacturer            Description                Model
                                                                     Number            Date        Due Date

          R&S             Spectrum Analyzer           FSU 26             200256     2019-05-09    2020-05-09

        Unknown               Attenuator                3dB              3dB-1       Each time       N/A

        Unknown             Coaxial Cable         C-SJ00-0010        C0010/04        Each time       N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

               Temperature:                 28.1 C
         Relative Humidity:                   46 %
            ATM Pressure:                   100.6 kPa
                    Test by:                Elena Lei
                  Test Date:               2019-07-22

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table and plots




                                                                                                    Page 31 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                                  Report No.: RDG190709001-00C

                                                                         Power Spectral
                                                   Frequency                                       Limit
                           Channel                                          Density
                                                     (MHz)                                      (dBm/3kHz)
                                                                          (dBm/3kHz)
                             Low                        2402                 -14.04                    ≤8
                            Middle                      2440                 -13.72                    ≤8
                            High                        2480                 -14.20                    ≤8



                                            Power Spectral Density, Low Channel
                                                                    * RBW 3 kHz    Marker 1 [T1 ]
                                                                    * VBW 10 kHz             -14.04 dBm
                     Ref    25 dBm              * Att   25 dB        SWT 120 ms         2.401951631 GHz

                           Offset    5 dB
                     20
                                                                                                            A

              1 PK   10
              MAXH
                                                                                                           LVL
                     0



                     -10                                        1


                     -20



                     -30                                                                                   3DB


                     -40



                     -50



                     -60



                     -70


                     Center   2.402 GHz                    105.15 kHz/                 Span   1.0515 MHz




              Date: 22.JUL.2019      14:14:56




                                                                                                                    Page 32 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                                  Report No.: RDG190709001-00C


                                         Power Spectral Density, Middle Channel
                                                                    * RBW 3 kHz    Marker 1 [T1 ]
                                                                    * VBW 10 kHz             -13.72 dBm
                     Ref    25 dBm              * Att   25 dB        SWT 120 ms         2.439953998 GHz

                           Offset    5 dB
                     20
                                                                                                           A

              1 PK   10
              MAXH
                                                                                                           LVL
                     0



                     -10                                        1


                     -20



                     -30                                                                                   3DB


                     -40



                     -50



                     -60



                     -70


                     Center   2.44 GHz                     104.55 kHz/                 Span   1.0455 MHz




              Date: 22.JUL.2019      14:18:13



                                            Power Spectral Density, High Channel
                                                                    * RBW 3 kHz    Marker 1 [T1 ]
                                                                    * VBW 10 kHz             -14.20 dBm
                     Ref    25 dBm              * Att   25 dB        SWT 120 ms         2.479951907 GHz

                           Offset    5 dB
                     20
                                                                                                           A

              1 PK   10
              MAXH
                                                                                                           LVL
                     0



                     -10                                        1


                     -20



                     -30                                                                                   3DB


                     -40



                     -50



                     -60



                     -70


                     Center   2.48 GHz                     104.55 kHz/                 Span   1.0455 MHz




              Date: 22.JUL.2019      14:16:28




                                             ***** END OF REPORT *****

                                                                                                                    Page 33 of 33



Document Created: 2019-08-07 19:51:47
Document Modified: 2019-08-07 19:51:47

© 2024 FCC.report