Test Report

FCC ID: 2AMH2-BH333A

Test Report

Download: PDF
FCCID_4449799

                                           FCC PART 15.247
                                               TEST REPORT

                                                              For

                MPOW TECHNOLOGY CO.,LIMITED

   FLAT/RM 605 6/F FA YUEN COMMERCIAL BUILDING 75-77 FA YUEN STREET MONGKOK KL
                                                        HONG KONG



                                       FCC ID: 2AMH2-BH333A


            Report Type:                                 Product Name:
            Original Report                              WIRELESS IN-EAR EARBUDS


                  Report Number:           RDG190723018-00A


                      Report Date:         2019-09-04


                                           Jerry Zhang
                     Reviewed By:          EMC Manager

                                           Bay Area Compliance Laboratories Corp. (Dongguan)
                 Test Laboratory:          No.69 Pulongcun, Puxinhu Industry Area,
                                           Tangxia, Dongguan, Guangdong, China
                                           Tel: +86-769-86858888
                                           Fax: +86-769-86858891
                                           www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be
used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal
Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”.


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                          Report No.: RDG190723018-00A




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................4
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................4
 OBJECTIVE ...................................................................................................................................................................4
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................4
 TEST METHODOLOGY ..................................................................................................................................................4
 MEASUREMENT UNCERTAINTY ....................................................................................................................................5
 TEST FACILITY .............................................................................................................................................................5
SYSTEM TEST CONFIGURATION ..........................................................................................................................6
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................6
  EQUIPMENT MODIFICATIONS .......................................................................................................................................6
  EUT EXERCISE SOFTWARE ..........................................................................................................................................6
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................7
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................7
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................8
SUMMARY OF TEST RESULTS ...............................................................................................................................9
FCC §15.247 (i) & §1.1310 & §2.1093- RF EXPOSURE..........................................................................................10
  APPLICABLE STANDARD ............................................................................................................................................10
FCC §15.203 - ANTENNA REQUIREMENT...........................................................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  ANTENNA INFORMATION AND CONNECTOR CONSTRUCTION.....................................................................................11
FCC §15.207 (a)– AC LINE CONDUCTED EMISSIONS ......................................................................................12
  APPLICABLE STANDARD ............................................................................................................................................12
  EUT SETUP ................................................................................................................................................................12
  EMI TEST RECEIVER SETUP .......................................................................................................................................12
  TEST PROCEDURE ......................................................................................................................................................12
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................13
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................13
  TEST DATA ................................................................................................................................................................13
FCC §15.209, §15.205, §15.247(d) - SPURIOUS EMISSIONS .................................................................................16
  APPLICABLE STANDARD ............................................................................................................................................16
  EUT SETUP ................................................................................................................................................................16
  EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP ..............................................................................................17
  TEST PROCEDURE ......................................................................................................................................................17
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................17
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................18
  TEST DATA ................................................................................................................................................................18
FCC §15.247(a) (2) –6 dB EMISSION BANDWIDTH .............................................................................................24
  APPLICABLE STANDARD ............................................................................................................................................24
  TEST PROCEDURE ......................................................................................................................................................24
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................24
  TEST DATA ................................................................................................................................................................24
FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER ......................................................27
  APPLICABLE STANDARD ............................................................................................................................................27
  TEST PROCEDURE ......................................................................................................................................................27

                                                                                                                                                            Page 2 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                           Report No.: RDG190723018-00A


    TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................27
    TEST DATA ................................................................................................................................................................27
FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE .......................................................29
  APPLICABLE STANDARD ............................................................................................................................................29
  TEST PROCEDURE ......................................................................................................................................................29
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................29
  TEST DATA ................................................................................................................................................................30
FCC §15.247(e) - POWER SPECTRAL DENSITY .................................................................................................32
  APPLICABLE STANDARD ............................................................................................................................................32
  TEST PROCEDURE ......................................................................................................................................................32
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................32
  TEST DATA ................................................................................................................................................................32




                                                                                                                                                             Page 3 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG190723018-00A

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

                    EUT Name:       WIRELESS IN-EAR EARBUDS
                    EUT Model:      BH333A
           Operation Frequency:     2402-2480MHz
         Maximum Output Power
                                    4.90dBm
                   (Conducted):
              Modulation Type:      GFSK
            Rated Input Voltage:    DC 3.7V from battery or charged by Charger Box
            External Dimension:     26mm(L) * 20mm(W) * 25mm(H)
                 Serial Number:     190723018
            EUT Received Date:      2019.7.23


Objective
This report is prepared on behalf of the MPOW TECHNOLOGY CO.,LIMITED in accordance with Part
2, Subpart J, Part 15, Subparts A and C of the Federal Communications Commission’s rules

The tests were performed in order to determine the compliance of the EUT with FCC Rules Part 15-
Subpart C, section 15.203, 15.205, 15.207, 15.209, 15.247 rules.


Related Submittal(s)/Grant(s)
FCC Part 15C DSS submissions with FCC ID: 2AMH2-BH333A.
Part of system submittal with FCC ID: 2AMH2-BH333A-1.


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices and KDB 558074 D01
DTS Meas Guidance v05r02.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).




                                                                                             Page 4 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190723018-00A

Measurement Uncertainty
            Parameter                                      Measurement Uncertainty
    Occupied Channel Bandwidth                                     ±5 %
    RF output power, conducted                                    ±0.61dB
  Power Spectral Density, conducted                               ±0.61 dB
                                          30M~200MHz: 4.55 dB,200M~1GHz: 5.92 dB,1G~6GHz: 4.98 dB,
    Unwanted Emissions, radiated
                                            6G~18GHz: 5.89 dB,18G~26.5G:5.47 dB,26.5G~40G:5.63 dB
   Unwanted Emissions, conducted                                    ±1.5 dB
           Temperature                                                ±1℃
             Humidity                                                 ±5%
   DC and low frequency voltages                                     ±0.4%
            Duty Cycle                                                 1%
 AC Power Lines Conducted Emission                        3.12 dB (150 kHz to 30 MHz)


Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the
FCC Public Access Link (PAL) database, FCC Registration No. : 897218, the FCC Designation No. :
CN1220.

The lab has been recognized by Innovation, Science and Economic Development Canada to test to
Canadian radio equipment requirements, the CAB identifier: CN0022.




                                                                                             Page 5 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG190723018-00A

SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in engineering mode.
For Bluetooth LE mode, 40 channels are provided for testing:

                                     Frequency                                      Frequency
                Channel                                       Channel
                                       (MHz)                                          (MHz)
                   0                    2402                    20                     2442
                   1                    2404                    …                       …
                   …                     …                      …                       …
                   …                    …                       …                      …
                    ..                  …                       38                    2478
                   19                  2440                     39                    2480

EUT was tested with channel 0, 19 and 39.


Equipment Modifications
No modification was made to the EUT tested.


EUT Exercise Software
The software 'Airoha.AB152x_verC_LabTestTool_20160615_2.1.0.11688_Verifying' was used for testing,
which was provided by manufacturer and the maximum power was configured as below table:

                                              Frequency
                           Channel                                      Power level
                                                (MHz)
                            Low                  2402                     default
                           Middle                2440                     default
                           High                  2480                     default

The duty cycle as below:

                            Ton                     Ton+off                Duty Cycle
                           (ms)                     (ms)                      (%)
                           0.277                    0.625                    44.32




                                                                                                Page 6 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                   Report No.: RDG190723018-00A




Local Support Equipment List and Details

       Manufacturer           Description              Model             Serial Number
          Huawei              Smartphone              EVR-AL00         A000009E3F501E
           IPRO                  Adapter              NTR-S01                190725003



Support Cable List and Details

         Cable           Shielding                     Length
                                       Ferrite Core              From Port               To
       Description         Type                         (m)
       USB Cable            No              No           0.3      Adapter                EUT
       USB Cable            No              No           0.8       EUT              Smartphone




                                                                                          Page 7 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190723018-00A

Block Diagram of Test Setup

AC Line Conducted Test:




Radiated Emissions:




                                                                      Page 8 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG190723018-00A

SUMMARY OF TEST RESULTS

              FCC Rules                              Description of Test               Result
       FCC§15.247 (i) & §1.1310 &
                                                       RF Exposure                   Compliance
               §2.1093
              FCC §15.203                           Antenna requirement              Compliance

            FCC §15.207(a)                   AC line conducted emissions             Compliance
         FCC §15.205, §15.209,
                                                    Spurious emissions               Compliance
              §15.247(d)
           FCC §15.247(a)(2)                   6 dB emission bandwidth               Compliance

           FCC §15.247(b)(3)              Maximum conducted output power             Compliance

            FCC §15.247(d)            100 kHz Bandwidth of frequency band edge       Compliance

            FCC §15.247(e)                      Power spectral density               Compliance




                                                                                                Page 9 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190723018-00A

FCC §15.247 (i) & §1.1310 & §2.1093- RF EXPOSURE
Applicable Standard
According to§15.247(i) and §1.1310, systems operating under the provisions of this section shall be
operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of
the Commission’s guideline.

According to KDB447498 D01 General RF Exposure Guidance v06:

The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50
mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
        • f(GHz) is the RF channel transmit frequency in GHz
        • Power and distance are rounded to the nearest mW and mm before calculation
        • The result is rounded to one decimal place for comparison
        • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below

The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5
mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion.


Measurement Result

The max conducted power including tune-up tolerance is 5.0 dBm (3.16 mW).
[(max. power of channel, mW)/(min. test separation distance, mm)][√f(GHz)]
= 3.16/5*(√2.480) = 1.0< 3.0

So the stand-alone SAR evaluation is not necessary.




                                                                                               Page 10 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG190723018-00A

FCC §15.203 - ANTENNA REQUIREMENT
Applicable Standard
According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
furnished by the responsible party shall be used with the device. The use of a permanently attached
antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered
sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a
broken antenna can be replaced by the user, but the user of a standard antenna jack or electrical connector
is prohibited. The structure and application of the EUT were analyzed to determine compliance with
section §15.203 of the rules. §15.203 state that the subject device must meet the following criteria:

a. Antenna must be permanently attached to the unit.
b. Antenna must use a unique type of connector to attach to the EUT.
c. Unit must be professionally installed, and installer shall be responsible for verifying that the correct
   antenna is employed with the unit.


Antenna Information And Connector Construction
The EUT has one internal antenna arrangement for BT, and the antenna gain is 2.96 dBi, fulfill the
requirement of this section. Please refer to the EUT photos.

Result: Compliance.




                                                                                                 Page 11 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190723018-00A

FCC §15.207 (a)– AC LINE CONDUCTED EMISSIONS
Applicable Standard
FCC§15.207(a)


EUT Setup




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.207.

The spacing between the peripherals was 10 cm.

The adapter was connected to the main lisn with a 120 V/60 Hz AC power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                      IF B/W
                              150 kHz – 30 MHz                      9 kHz


Test Procedure

During the conducted emission test, the adapter was connected to the first LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.
                                                                                              Page 12 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RDG190723018-00A

Corrected Amplitude & Margin Calculation
The basic equation is as follows:

VC = VR + AC + VDF
Cf = AC + VDF

Herein,
VC (cord. Reading): corrected voltage amplitude
VR: reading voltage amplitude
Ac: attenuation caused by cable loss
VDF: voltage division factor of AMN
Cf: Correction Factor

The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation
for margin calculation is as follows:

                                    Margin = Limit – Corrected Amplitude


Test Equipment List and Details

                                                                     Serial         Calibration   Calibration
      Manufacturer              Description           Model
                                                                    Number             Date        Due Date
         Unknown                Coaxial Cable      C-NJNJ-50        C-0200-01       2018-09-05     2019-09-05
           R&S                  Test Software        EMC32        Version8.53.0        N/A            N/A
           R&S              Two-line V-network      ENV 216          101614         2018-12-10     2019-12-10
           R&S               EMI Test Receiver        ESPI           100120         2019-05-09     2020-05-09

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

               Temperature:            27.6 oC
          Relative Humidity:            63 %
             ATM Pressure:            100.4kPa
                      Tester:          Sky Lu
                   Test Date:        2019-08-29

Test Result: Compliance

Test Mode: Charging



                                                                                                    Page 13 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                      Report No.: RDG190723018-00A


   AC120V, 60 Hz, Line:


                          80

                          70
                                                                                                Quasi-Peak Limit
                          60
                                                                                                   Average Limit
                          50
           Level in dBμ




                          40

                          30

                          20

                          10

                          0
                          150k   300    400 500   800 1M        2M    3M     4M 5M 6   8 10M          20M     30M
                                                           Frequency in Hz




               Frequency           QuasiPeak        Bandwidth                 Corr.    Margin         Limit
                                                                     Line
                 (MHz)              (dBμV)            (kHz)                   (dB)      (dB)         (dBμV)
                0.181216              46.9            9.000          L1       10.8      17.5           64.4
                     0.405722           37.3           9.000         L1        10.0      20.4          57.7
                     0.443733           38.9           9.000         L1         9.9      18.1          57.0
                     0.520311           36.9           9.000         L1         9.9      19.1          56.0
                     0.552321           33.8           9.000         L1         9.8      22.2          56.0
                     0.722551           31.6           9.000         L1         9.8      24.4          56.0

                Frequency              Average      Bandwidth                  Corr.   Margin         Limit
                                                                     Line
                  (MHz)                (dBμV)         (kHz)                    (dB)     (dB)         (dBμV)
                 0.177646                29.7         9.000           L1       10.8     24.9           54.6
                      0.405722          21.9           9.000          L1       10.0      25.8          47.7
                      0.439339          24.6           9.000          L1        9.9      22.5          47.1
                      0.510059          29.9           9.000          L1        9.9      16.1          46.0
                      1.119461          19.6           9.000          L1        9.8      26.4          46.0
                      1.554585          20.8           9.000          L1        9.7      25.2          46.0




                                                                                                              Page 14 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                      Report No.: RDG190723018-00A

   AC120V, 60 Hz, Neutral:


                          80

                          70
                                                                                                Quasi-Peak Limit
                          60
                                                                                                   Average Limit
                          50
           Level in dBμ




                          40

                          30

                          20

                          10

                          0
                          150k   300    400 500   800 1M        2M    3M     4M 5M 6   8 10M          20M     30M
                                                           Frequency in Hz




               Frequency           QuasiPeak        Bandwidth                 Corr.    Margin         Limit
                                                                     Line
                 (MHz)              (dBμV)            (kHz)                   (dB)      (dB)         (dBμV)
                0.160820              44.6            9.000           N       11.0      20.8           65.4
                     0.277982           34.7           9.000          N        10.2      26.2          60.9
                     0.490157           36.3           9.000          N         9.9      19.9          56.2
                     0.530770           36.4           9.000          N         9.9      19.6          56.0
                     0.935889           27.3           9.000          N         9.8      28.7          56.0
                     1.299660           26.3           9.000          N         9.8      29.7          56.0

                Frequency              Average      Bandwidth                  Corr.   Margin         Limit
                                                                     Line
                  (MHz)                (dBμV)         (kHz)                    (dB)     (dB)         (dBμV)
                 0.167350                28.1         9.000           N        10.9     27.0           55.1
                      0.471031          23.1           9.000          N         9.9      23.4          46.5
                      0.490157          24.8           9.000          N         9.9      21.4          46.2
                      0.536077          29.3           9.000          N         9.9      16.7          46.0
                      0.552321          23.3           9.000          N         9.8      22.7          46.0
                      0.574747          19.9           9.000          N         9.8      26.1          46.0




                                                                                                              Page 15 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG190723018-00A

FCC §15.209, §15.205, §15.247(d) - SPURIOUS EMISSIONS
Applicable Standard
FCC §15.247 (d); §15.209; §15.205

EUT Setup
Below 1GHz:




Above 1GHz:




The radiated emission below 1GHz tests were performed in the 10 meters chamber, above 1GHz tests were
performed in the 3 meters chamber B, using the setup accordance with the ANSI C63.10-2013. The
specification used was the FCC 15.209, and FCC 15.247 limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.

The spacing between the peripherals was 10 cm.




                                                                                              Page 16 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190723018-00A

EMI Test Receiver & Spectrum Analyzer Setup

The system was investigated from 30 MHz to 25 GHz.

During the radiated emission test, the EMI test receiver & Spectrum Analyzer Setup were set with the
following configurations:

30MHz-1000MHz:

                    Measurement             RBW            Video B/W       IF B/W
                        QP                 120 kHz          300 kHz        120kHz

1GHz- 25GHz:

                       Measurement            Duty cycle       RBW         Video B/W
                           PK                    Any           1MHz          3 MHz
                                                >98%           1MHz          10 Hz
                            AV
                                                <98%           1MHz            1/T

Note: T is minimum transmission duration

If the maximized peak measured value complies with under the QP/Average limit more than 6dB, then it is
unnecessary to perform an QP/Average measurement.


Test Procedure

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

Data was recorded in Quasi-peak detection mode for frequency range of 30 MHz-1 GHz, peak and
Average detection modes for frequencies above 1 GHz.


Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit –Corrected Amplitude




                                                                                             Page 17 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG190723018-00A

Test Equipment List and Details

                                                                      Serial        Calibration    Calibration
    Manufacturer           Description             Model
                                                                     Number            Date         Due Date
         R&S           EMI Test Receiver           ESCI               101121        2019-05-09     2020-05-09
        Farad            Test Software            EZ-EMC             V1.1.4.2          N/A            N/A
    Sunol Sciences          Antenna                 JB3             A060611-3       2017-07-21     2020-07-21
       Unknown           Coaxial Cable           C-NJNJ-50          C-1000-01       2018-09-05     2019-09-05
       Unknown           Coaxial Cable           C-NJNJ-50          C-0400-02       2018-09-05     2019-09-05
       Unknown           Coaxial Cable           C-NJNJ-50          C-0530-01       2018-09-24     2019-09-24
          HP               Amplifier               8447F           2443A01912       2018-09-05     2019-09-05
        Agilent        Spectrum Analyzer          E4440A           SG43360054       2019-05-09     2020-05-09
    ETS-Lindgren         Horn Antenna               3115            000 527 35      2018-10-12     2021-10-12
      Ducommun                                                     1007726-01
                          Horn Antenna         ARH-4223-02                          2016-11-18     2019-11-18
     Technolagies                                                      1304
       Unknown            Coaxial Cable         C-SJSJ-50           C-0800-01       2018-09-05     2019-09-05
       Unknown            Coaxial Cable       C-2.4J2.4J-50         C-0700-02       2019-06-27     2020-06-27
                                             AFS42-00101800-
        MITEQ               Amplifier                                 2001271       2018-09-05     2019-09-05
                                                 25-S-42
       Quinstar             Amplifier       QLW-18405536-JO        15964001001      2019-06-27     2020-06-27
                                            OBSF-2400-2483.5-
     E-Microwave        Band-stop Filters                          OE01601525       2019-06-16     2020-06-16
                                                    S
     Micro-tronics       High Pass Filter      HPM50111              S/N-G217       2019-06-16     2020-06-16

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data

     Environmental Conditions

                      Test Items    Radiation Below 1GHz     Radiation Above 1GHz
                  Temperature:              26 C                    24.8 C
             Relative Humidity:              59 %                     51 %
                ATM Pressure:             100.5 kPa                100.1 kPa
                         Tester:           Ade Xiao                 Neil Liao
                      Test Date:         2019-08-26               2019-08-15

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table and plots.




                                                                                                    Page 18 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190723018-00A

1) 30MHz-1GHz (High Channel was the worst):
Horizontal:




                  Receiver                     Correction     Cord.
   Frequency                                                               Limit        Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                               (dBuV/m)        (dB)
                  (dBuV)                        (dB/m)      (dBuV/m)
     30.0000       28.15           peak           -7.95       20.20        40.00         19.80
    146.4000       30.07           peak          -12.77       17.30        43.50         26.20
    162.8900       32.31           peak          -12.88       19.43        43.50         24.07
    258.9200       27.71           peak          -12.80       14.91        46.00         31.09
    374.3500       27.38           peak           -8.72       18.66        46.00         27.34
    569.3200       26.31           peak           -3.72       22.59        46.00         23.41




                                                                                        Page 19 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190723018-00A

Vertical:




                  Receiver                     Correction      Cord.
   Frequency                                                                Limit        Margin
                  Reading        Detector       Factor         Amp.
     (MHz)                                                                (dBuV/m)        (dB)
                  (dBuV)                        (dB/m)       (dBuV/m)

     30.9700        28.30          peak              -8.40    19.90         40.00         20.10
    162.8900        29.03          peak             -12.88    16.15         43.50         27.35
    201.6900        31.83          peak             -13.08    18.75         43.50         24.75
    420.9100        28.04          peak              -7.95    20.09         46.00         25.91
    547.0100        26.10          peak              -4.26    21.84         46.00         24.16
    665.3500        25.73          peak              -2.34    23.39         46.00         22.61




                                                                                         Page 20 of 34


  Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190723018-00A

 2) 1-25GHz:
                  Receiver             Rx Antenna      Cable Amplifier   Corrected
Frequency                                                                              Limit      Margin
            Reading    Detector       Polar Factor       loss    Gain    Amplitude
  (MHz)                                                                              (dBμV/m)      (dB)
            (dBμV) (PK/QP/AV)         (H/V) (dB/m)      (dB)     (dB)    (dBμV/m)
                                          Low Channel: 2402 MHz
 2402.00      65.35         PK          H     28.10     1.80      0.00     95.25        N/A         N/A
 2402.00      64.71         AV          H     28.10     1.80      0.00     94.61        N/A         N/A
 2402.00      58.94         PK          V     28.10     1.80      0.00     88.84        N/A         N/A
 2402.00      58.62         AV          V     28.10     1.80      0.00     88.52        N/A         N/A
 2390.00      28.80         PK          H     28.08     1.80      0.00     58.68       74.00       15.32
 2390.00      14.87         AV          H     28.08     1.80      0.00     44.75       54.00        9.25
 4804.00      51.75         PK          H     32.91     3.17     37.20     50.63       74.00       23.37
 4804.00      45.80         AV          H     32.91     3.17     37.20     44.68       54.00        9.32
 7206.00      46.84         PK          H     35.74     4.82     37.23     50.17       74.00       23.83
 7206.00      38.05         AV          H     35.74     4.82     37.23     41.38       54.00       12.62
                                         Middle Channel: 2440 MHz
 2440.00      66.19         PK          H     28.18     1.82      0.00     96.19        N/A         N/A
 2440.00      65.62         AV          H     28.18     1.82      0.00     95.62        N/A         N/A
 2440.00      58.81         PK          V     28.18     1.82      0.00     88.81        N/A         N/A
 2440.00      58.58         AV          V     28.18     1.82      0.00     88.58        N/A         N/A
 4880.00      51.36         PK          H     33.06     3.27     37.21     50.48       74.00       23.52
 4880.00      46.75         AV          H     33.06     3.27     37.21     45.87       54.00        8.13
 7320.00      45.82         PK          H     36.03     4.62     37.37     49.10       74.00       24.90
 7320.00      37.19         AV          H     36.03     4.62     37.37     40.47       54.00       13.53
                                          High Channel: 2480 MHz
 2480.00      66.95         PK          H     28.26     1.84      0.00     97.05        N/A         N/A
 2480.00      66.41         AV          H     28.26     1.84      0.00     96.51        N/A         N/A
 2480.00      59.78         PK          V     28.26     1.84      0.00     89.88        N/A         N/A
 2480.00      59.57         AV          V     28.26     1.84      0.00     89.67        N/A         N/A
 2483.50      33.44         PK          H     28.27     1.84      0.00     63.55       74.00       10.45
 2483.50      17.67         AV          H     28.27     1.84      0.00     47.78       54.00        6.22
 4960.00      53.39         PK          H     33.22     3.23     37.25     52.59       74.00       21.41
 4960.00      47.97         AV          H     33.22     3.23     37.25     47.17       54.00       6.83
 7440.00      50.40         PK          H     36.34     4.41     37.52     53.63       74.00       20.37
 7440.00      42.42         AV          H     36.34     4.41     37.52     45.65       54.00       8.35




                                                                                          Page 21 of 34


      Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190723018-00A

     Worst plots (High Channel)
     Horizontal


Fundamental
Test with Band
Rejection Filter




                                                                           Page 22 of 34


   Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190723018-00A

  Vertical



Fundamental
Test with Band
Rejection Filter




                                                                        Page 23 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190723018-00A

FCC §15.247(a) (2) –6 dB EMISSION BANDWIDTH
Applicable Standard
According to FCC §15.247(a) (2)
Systems using digital modulation techniques may operate in the 902–928 MHz, 2400–2483.5 MHz, and
5725–5850 MHz bands. The minimum 6 dB bandwidth shall be at least 500 kHz.


Test Procedure

a) Set RBW = 100 kHz.
b) Set the video bandwidth (VBW) ≥ 3×RBW.
c) Detector = Peak.
d) Trace mode = max hold.
e) Sweep = auto couple.
f) Allow the trace to stabilize.
g) Measure the maximum width of the emission that is constrained by the frequencies associated with the
   two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB relative to the
   maximum level measured in the fundamental emission.


                                 EUT                                 Test Equipment


Test Equipment List and Details

                                                                     Serial       Calibration    Calibration
    Manufacturer            Description            Model
                                                                    Number           Date         Due Date

         R&S            Spectrum Analyzer          FSV40             101474       2019-01-09      2020-01-09

       Unknown             Coaxial Cable         C-SJ00-0010       C0010/03        Each time         N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

               Temperature:            27.3 C
         Relative Humidity:             64 %
             ATM Pressure:           100.3 kPa
                      Tester:         Lily Xie
                  Test Date:         2019-09-04

    Test Mode: Transmitting
   Test Result: Compliance. Please refer to the following table and plots.

                                                                                                    Page 24 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                   Report No.: RDG190723018-00A


                                                    6 dB Emission
                                       Frequency                     Limit
                         Channel                      Bandwidth
                                         (MHz)                      (MHz)
                                                        (MHz)
                          Low             2402           0.688       ≥0.5
                         Middle           2440           0.692       ≥0.5
                         High             2480           0.716       ≥0.5



                                             Low Channel




                                                                                     Page 25 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)           Report No.: RDG190723018-00A


                                           Middle Channel




                                             High Channel




                                                                             Page 26 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190723018-00A

FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER
Applicable Standard
According to FCC §15.247(b) (3), for systems using digital modulation in the 902-928 MHz, 2400-2483.5
MHz, and 5725-5850 MHz bands: 1 Watt. As an alternative to a peak power measurement, compliance
with the one Watt limit can be based on a measurement of the maximum conducted output power.
Maximum Conducted Output Power is defined as the total transmit power delivered to all antennas and
antenna elements averaged across all symbols in the signaling alphabet when the transmitter is operating at
its maximum power control level. Power must be summed across all antennas and antenna elements. The
average must not include any time intervals during which the transmitter is off or is transmitting at a
reduced power level. If multiple modes of operation are possible (e.g., alternative modulation methods),
the maximum conducted output power is the highest total transmit power occurring in any mode.


Test Procedure
1. Place the EUT on a bench and set it in transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to test
   equipment.
3. Add a correction factor to the display.


Test Equipment List and Details

                                                                   Serial         Calibration    Calibration
    Manufacturer           Description             Model
                                                                  Number             Date         Due Date

       Unknown            Coaxial Cable          C-SJ00-0010      C0010/04         Each time         N/A
                          USB Wideband
        Agilent                                   U2021XA       MY5425009         2019-05-09      2020-05-09
                           Power Sensor

  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

              Temperature:            27.3 C
         Relative Humidity:            64 %
             ATM Pressure:           100.3 kPa
                     Tester:         Lily Xie
                  Test Date:        2019-09-04

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table.




                                                                                                    Page 27 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                   Report No.: RDG190723018-00A

                                                      Max Peak
                                         Frequency    Conducted      Limit
                           Channel
                                           (MHz)     Output Power   (dBm)
                                                        (dBm)
                             Low            2402         4.64        30
                            Middle          2440         4.76        30
                            High            2480         4.90        30




                                                                                     Page 28 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190723018-00A

FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE
Applicable Standard
According to FCC§15.247(d):In any 100 kHz bandwidth outside the frequency band in which the spread
spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is
produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the
band that contains the highest level of the desired power, based on either an RF conducted or a radiated
measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If
the transmitter complies with the conducted power limits based on the use of RMS averaging over a time
interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph
shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in §15.209(a) is not
required. In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must
also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)).


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect its
   antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured
   frequency within its operating range, and make sure the instrument is operated in its linear range.
3. Set RBW to 100 kHz and VBW of spectrum analyzer to 300 kHz with a convenient frequency span
   including 100 kHz bandwidth from band edge.
4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the
   graph with marking the highest point and edge frequency.
5. Repeat above procedures until all measured frequencies were complete.


Test Equipment List and Details

                                                                   Serial         Calibration    Calibration
    Manufacturer           Description            Model
                                                                  Number             Date         Due Date

         R&S            Spectrum Analyzer         FSV40            101474         2019-01-09      2020-01-09

       Unknown            Coaxial Cable        C-SJ00-0010        C0010/03         Each time         N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                    Page 29 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                Report No.: RDG190723018-00A

Test Data
     Environmental Conditions

              Temperature:          27.3 C
         Relative Humidity:          64 %
            ATM Pressure:          100.3 kPa
                     Tester:       Lily Xie
                 Test Date:       2019-09-04

Test mode: Transmitting
Test Result: Compliance. Please refer to following plots.


                                          Band Edge, Left Side




                                                                                  Page 30 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)               Report No.: RDG190723018-00A


                                        Band Edge, Right Side




                                                                                 Page 31 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RDG190723018-00A

FCC §15.247(e) - POWER SPECTRAL DENSITY
Applicable Standard
According to FCC§15.247(e):For digitally modulated systems, the power spectral density conducted from
the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time
interval of continuous transmission. This power spectral density shall be determined in accordance with
the provisions of paragraph (b) of this section. The same method of determining the conducted output
power shall be used to determine the power spectral density.


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT was set without connection to measurement instrument. Turn on the EUT and
   connect its antenna terminal to measurement instrument via a low loss cable. Then set it to any one
   measured frequency within its operating range, and make sure the instrument is operated in its linear
   range.
3. Set the RBW = 3 kHz, VBW = 10 kHz, Set the span to 1.5 times the DTS bandwidth.
4. Use the peak marker function to determine the maximum amplitude level.


Test Equipment List and Details

                                                                      Serial        Calibration   Calibration
     Manufacturer            Description             Model
                                                                     Number            Date        Due Date

          R&S             Spectrum Analyzer          FSV40               101474     2019-01-09    2020-01-09

        Unknown             Coaxial Cable          C-SJ00-0010       C0010/03        Each time       N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

                Temperature:            27.3 C
          Relative Humidity:             64 %
              ATM Pressure:            100.3 kPa
                       Tester:         Lily Xie
                   Test Date:         2019-09-04

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table and plots




                                                                                                    Page 32 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190723018-00A


                                                    Power Spectral
                                   Frequency                            Limit
                     Channel                           Density
                                     (MHz)                           (dBm/3kHz)
                                                     (dBm/3kHz)
                       Low            2402              -20.84           ≤8
                      Middle          2440              -21.54           ≤8
                      High            2480              -22.85           ≤8



                                Power Spectral Density, Low Channel




                                                                                        Page 33 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190723018-00A


                              Power Spectral Density, Middle Channel




                                Power Spectral Density, High Channel




                                  ***** END OF REPORT *****