Test Report

FCC ID: 2AMH2-BH298A

Test Report

Download: PDF
FCCID_4293905

                                           FCC PART 15.247
                                               TEST REPORT

                                                              For

                MPOW TECHNOLOGY CO., LIMITED
       RM 603, 6/F, HANG PONT COMM BLDG 31 TONKIN ST CHEUNG SHA WAN KL HK China



                                       FCC ID: 2AMH2-BH298A


            Report Type:                                 Product Name:
            Original Report                              Wire less Receiver


                  Report Number:           RDG190426008-00A


                      Report Date:         2019-05-09


                                           Jerry Zhang
                     Reviewed By:          EMC Manager

                                           Bay Area Compliance Laboratories Corp. (Dongguan)
                 Test Laboratory:          No.69 Pulongcun, Puxinhu Industry Area,
                                           Tangxia, Dongguan, Guangdong, China
                                           Tel: +86-769-86858888
                                           Fax: +86-769-86858891
                                           www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be
used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal
Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”.


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                          Report No.: RDG190426008-00A




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................4
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................4
 OBJECTIVE ...................................................................................................................................................................4
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................4
 TEST METHODOLOGY ..................................................................................................................................................4
 MEASUREMENT UNCERTAINTY ....................................................................................................................................5
 TEST FACILITY .............................................................................................................................................................5
SYSTEM TEST CONFIGURATION ..........................................................................................................................6
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................6
  EQUIPMENT MODIFICATIONS .......................................................................................................................................6
  EUT EXERCISE SOFTWARE ..........................................................................................................................................6
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................7
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................7
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................8
SUMMARY OF TEST RESULTS ...............................................................................................................................9
FCC §15.247 (i) & §1.1310 & §2.1093- RF EXPOSURE..........................................................................................10
  APPLICABLE STANDARD ............................................................................................................................................10
FCC §15.203 - ANTENNA REQUIREMENT...........................................................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  ANTENNA INFORMATION AND CONNECTOR CONSTRUCTION.....................................................................................11
FCC §15.207 (a)– AC LINE CONDUCTED EMISSIONS ......................................................................................12
  APPLICABLE STANDARD ............................................................................................................................................12
  EUT SETUP ................................................................................................................................................................12
  EMI TEST RECEIVER SETUP .......................................................................................................................................12
  TEST PROCEDURE ......................................................................................................................................................13
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................13
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................13
  TEST DATA ................................................................................................................................................................14
FCC §15.209, §15.205, §15.247(d) - SPURIOUS EMISSIONS .................................................................................17
  APPLICABLE STANDARD ............................................................................................................................................17
  EUT SETUP ................................................................................................................................................................17
  EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP ..............................................................................................18
  TEST PROCEDURE ......................................................................................................................................................18
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................18
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................19
  TEST DATA ................................................................................................................................................................19
FCC §15.247(a) (2) –6 dB EMISSION BANDWIDTH .............................................................................................25
  APPLICABLE STANDARD ............................................................................................................................................25
  TEST PROCEDURE ......................................................................................................................................................25
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................25
  TEST DATA ................................................................................................................................................................25
FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER ......................................................28
  APPLICABLE STANDARD ............................................................................................................................................28
  TEST PROCEDURE ......................................................................................................................................................28

                                                                                                                                                            Page 2 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                           Report No.: RDG190426008-00A


    TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................28
    TEST DATA ................................................................................................................................................................29
FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE .......................................................30
  APPLICABLE STANDARD ............................................................................................................................................30
  TEST PROCEDURE ......................................................................................................................................................30
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................30
  TEST DATA ................................................................................................................................................................30
FCC §15.247(e) - POWER SPECTRAL DENSITY .................................................................................................32
  APPLICABLE STANDARD ............................................................................................................................................32
  TEST PROCEDURE ......................................................................................................................................................32
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................32
  TEST DATA ................................................................................................................................................................32




                                                                                                                                                             Page 3 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RDG190426008-00A

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

                    EUT Name:       Wireless Receiver
                    EUT Model:      BH298A
           Operation Frequency:     2402-2480 MHz
         Maximum Output Power
                                    8.8 dBm
                   (Conducted):
              Modulation Type:      GFSK
            Rated Input Voltage:    DC3.7V from Battery or DC5V from adapter
            External Dimension:     57mm(L)* 33mm(W)*9.5mm(H)
                 Serial Number:     190426008
            EUT Received Date:      2019.04.28


Objective
This report is prepared on behalf of MPOW TECHNOLOGY CO., LIMITED in accordance with Part 2,
Subpart J, Part 15, Subparts A and C of the Federal Communications Commission’s rules

The tests were performed in order to determine the compliance of the EUT with FCC Rules Part 15-
Subpart C, section 15.203, 15.205, 15.207, 15.209, 15.247 rules.


Related Submittal(s)/Grant(s)
FCC Part 15C DSS submissions with FCC ID: 2AMH2-BH298A.


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices and KDB 558074 D01
DTS Meas Guidance v05r02.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).




                                                                                           Page 4 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190426008-00A

Measurement Uncertainty
            Parameter                                      Measurement Uncertainty
    Occupied Channel Bandwidth                                     ±5 %
    RF output power, conducted                                    ±0.61dB
  Power Spectral Density, conducted                               ±0.61 dB
                                         30M~200MHz: 4.55 dB,200M~1GHz: 5.92 dB,1G~6GHz: 4.98 dB,
    Unwanted Emissions, radiated
                                           6G~18GHz: 5.89 dB,18G~26.5G:5.47 dB,26.5G~40G:5.63 dB
   Unwanted Emissions, conducted                                    ±1.5 dB
           Temperature                                                ±1℃
             Humidity                                                 ±5%
   DC and low frequency voltages                                     ±0.4%
            Duty Cycle                                                 1%
 AC Power Lines Conducted Emission                        3.12 dB (150 kHz to 30 MHz)


Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the
FCC Public Access Link (PAL) database, FCC Registration No. : 897218, the FCC Designation No. :
CN1220.

The lab has been recognized by Innovation, Science and Economic Development Canada to test to
Canadian radio equipment requirements, the CAB identifier : CN0022.




                                                                                             Page 5 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190426008-00A

SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in engineering mode.
For Bluetooth LE mode, 40 channels are provided for testing:

                                    Frequency                                     Frequency
                Channel                                       Channel
                                      (MHz)                                         (MHz)
                   0                   2402                     20                   2442
                   1                   2404                     …                     …
                   …                    …                       …                     …
                   …                    …                       …                     …
                    ..                 …                        38                   2478
                   19                 2440                      39                   2480

EUT was tested with channel 0, 19 and 39.


Equipment Modifications
No modification was made to the EUT tested.


EUT Exercise Software
The maximum power was configured by system default setting: The test software ' Blue Test 3 ' only for
change modes and channels.

The duty cycle as below:

                            Ton                     Ton+off             Duty Cycle
                           (ms)                     (ms)                   (%)
                           0.391                    0.651                 60.06




                                                                                              Page 6 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                 Report No.: RDG190426008-00A




Local Support Equipment List and Details

       Manufacturer           Description             Model           Serial Number
         Unknown                 Adapter               M4                   /



Support Cable List and Details

         Cable           Shielding                    Length
                                       Ferrite Core            From Port              To
       Description         Type                        (m)
       USB cable            No              No          0.8     Adapter           EUT
     Earphone Cable         No              No         1.2     Earphone           EUT




                                                                                      Page 7 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190426008-00A

Block Diagram of Test Setup




                                                                      Page 8 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190426008-00A

SUMMARY OF TEST RESULTS

               FCC Rules                            Description of Test               Result

       FCC §15.247 (i) & §1.1310 &
                                                       RF Exposure                  Compliance
                §2.1093
                §15.203                         Antenna Requirement                 Compliance

               §15.207 (a)                  AC Line Conducted Emissions             Compliance
            §15.205, §15.209,
                                                    Spurious Emissions              Compliance
               §15.247(d)
             §15.247 (a)(2)                          6 dB Bandwidth                 Compliance

             §15.247(b)(3)                Maximum Conducted Output Power            Compliance

               §15.247(d)             100 kHz Bandwidth of Frequency Band Edge      Compliance

               §15.247(e)                       Power Spectral Density              Compliance




                                                                                               Page 9 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190426008-00A

FCC §15.247 (i) & §1.1310 & §2.1093- RF EXPOSURE
Applicable Standard
According to§15.247(i) and §1.1310, systems operating under the provisions of this section shall be
operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of
the Commission’s guideline.

According to KDB447498 D01 General RF Exposure Guidance v06:

The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50
mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
        • f(GHz) is the RF channel transmit frequency in GHz
        • Power and distance are rounded to the nearest mW and mm before calculation
        • The result is rounded to one decimal place for comparison
        • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below

The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5
mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion.


Measurement Result

The max conducted power including tune-up tolerance is 9 dBm (7.94 mW).
[(max. power of channel, mW)/(min. test separation distance, mm)][√f(GHz)]
=7.94/5*(√2.480) = 2.5< 3.0

So the stand-alone SAR evaluation is not necessary.




                                                                                               Page 10 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG190426008-00A

FCC §15.203 - ANTENNA REQUIREMENT
Applicable Standard
According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
furnished by the responsible party shall be used with the device. The use of a permanently attached
antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered
sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a
broken antenna can be replaced by the user, but the user of a standard antenna jack or electrical connector
is prohibited. The structure and application of the EUT were analyzed to determine compliance with
section §15.203 of the rules. §15.203 state that the subject device must meet the following criteria:

a. Antenna must be permanently attached to the unit.
b. Antenna must use a unique type of connector to attach to the EUT.
c. Unit must be professionally installed, and installer shall be responsible for verifying that the correct
   antenna is employed with the unit.


Antenna Information And Connector Construction
The EUT has one internal antenna arrangement for BT, and the antenna gain is 0 dBi, fulfill the
requirement of this section. Please refer to the EUT photos.

Result: Compliance.




                                                                                                 Page 11 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190426008-00A

FCC §15.207 (a)– AC LINE CONDUCTED EMISSIONS
Applicable Standard
FCC§15.207(a)


EUT Setup




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.207.

The spacing between the peripherals was 10 cm.

The adapter was connected to the main lisn with a 120 V/60 Hz AC power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                      IF B/W
                              150 kHz – 30 MHz                      9 kHz




                                                                                              Page 12 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RDG190426008-00A

Test Procedure

During the conducted emission test, the adapter was connected to the first LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.


Corrected Amplitude & Margin Calculation
The basic equation is as follows:

VC = VR + AC + VDF
Cf = AC + VDF

Herein,
VC (cord. Reading): corrected voltage amplitude
VR: reading voltage amplitude
Ac: attenuation caused by cable loss
VDF: voltage division factor of AMN
Cf: Correction Factor

The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation
for margin calculation is as follows:

                                    Margin = Limit – Corrected Amplitude


Test Equipment List and Details

                                                                     Serial         Calibration   Calibration
      Manufacturer              Description           Model
                                                                    Number             Date        Due Date
           R&S               EMI Test Receiver        ESCI           101121         2019-03-23     2020-03-23
         Unknown               Coaxial Cable       C-NJNJ-50        C-0200-01       2018-09-05     2019-09-05
           R&S                 Test Software         EMC32        Version8.53.0        N/A            N/A
           R&S              Two-line V-network      ENV 216          101614         2018-12-10     2019-12-10

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                    Page 13 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)          Report No.: RDG190426008-00A

Test Data
    Environmental Conditions

             Temperature:            26.5 oC
        Relative Humidity:            63%
            ATM Pressure:           100.6kPa

     The testing was performed by Ade Xiao on 2019-04-29

Test Result: Compliance

Test Mode: Transmitting




                                                                            Page 14 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                            Report No.: RDG190426008-00A

    AC120 V, 60 Hz, Line:


                         80

                         70
                                                                                                      Quasi-Peak Limit
                         60
                                                                                                         Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                          0
                          150k      300    400 500    800 1M           2M   3M     4M 5M 6   8 10M          20M      30M
                                                                 Frequency in Hz



                     Frequency            QuasiPeak       Bandwidth                  Corr.    Margin         Limit
                                                                            Line
                       (MHz)               (dBμV)           (kHz)                    (dB)      (dB)         (dBμV)
                      0.160820               32.8           9.000           L1       11.0      32.6           65.4
                         0.286405           26.2               9.000        L1        10.2     34.4           60.6
                         0.574747           21.7               9.000        L1        9.8      34.3           56.0
                         1.086538           20.4               9.000        L1        9.8      35.6           56.0
                         1.339041           19.8               9.000        L1        9.8      36.2           56.0
                         4.375596           19.3               9.000        L1        9.8      36.7           56.0

                     Frequency             Average        Bandwidth                  Corr.    Margin         Limit
                                                                            Line
                       (MHz)               (dBμV)           (kHz)                    (dB)      (dB)         (dBμV)
                      0.426418               16.3           9.000           L1        9.9      31.0           47.3
                         0.580495           17.4               9.000        L1        9.8      28.6           46.0
                         1.075780           18.0               9.000        L1        9.8      28.0           46.0
                         1.286792           16.8               9.000        L1        9.8      29.2           46.0
                         3.182389           14.5               9.000        L1        9.8      31.5           46.0
                         4.930532           14.8               9.000        L1        9.8      31.2           46.0




                                                                                                                     Page 15 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                            Report No.: RDG190426008-00A

    AC120 V, 60 Hz, Neutral:


                         80

                         70
                                                                                                      Quasi-Peak Limit
                         60
                                                                                                         Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                          0
                          150k      300    400 500    800 1M           2M   3M     4M 5M 6   8 10M          20M      30M
                                                                 Frequency in Hz



                     Frequency            QuasiPeak       Bandwidth                  Corr.    Margin         Limit
                                                                            Line
                       (MHz)               (dBμV)           (kHz)                    (dB)      (dB)         (dBμV)
                      0.181216               29.7           9.000            N       10.8      34.7           64.4
                         0.264490           24.4               9.000         N        10.3     36.9           61.3
                         0.580495           22.7               9.000         N        9.8      33.3           56.0
                         1.086538           21.2               9.000         N        9.8      34.8           56.0
                         1.339041           21.2               9.000         N        9.8      34.8           56.0
                         3.150880           20.7               9.000         N        9.8      35.3           56.0

                     Frequency             Average        Bandwidth                  Corr.    Margin         Limit
                                                                            Line
                       (MHz)               (dBμV)           (kHz)                    (dB)      (dB)         (dBμV)
                      0.397728               17.2           9.000            N       10.0      30.7           47.9
                         0.580495           17.3               9.000         N        9.8      28.7           46.0
                         1.075780           18.6               9.000         N        9.8      27.4           46.0
                         1.261437           17.5               9.000         N        9.8      28.5           46.0
                         3.150880           15.5               9.000         N        9.8      30.5           46.0
                         3.883120           15.2               9.000         N        9.8      30.8           46.0




                                                                                                                     Page 16 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190426008-00A


FCC §15.209, §15.205, §15.247(d) - SPURIOUS EMISSIONS
Applicable Standard
FCC §15.247 (d); §15.209; §15.205

EUT Setup
Below 1GHz:




Above 1GHz:




The radiated emission Below 1GHz tests were performed in the 10 meters chamber, above 1GHz tests
were performed in the 3 meters chamber B, using the setup accordance with the ANSI C63.10-2013. The
specification used was the FCC 15.209, and FCC 15.247 limits.

The spacing between the peripherals was 10 cm.




                                                                                         Page 17 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190426008-00A

EMI Test Receiver & Spectrum Analyzer Setup

The system was investigated from 30 MHz to 25 GHz.

During the radiated emission test, the EMI test receiver & Spectrum Analyzer Setup were set with the
following configurations:

30MHz-1000MHz:

                    Measurement             RBW            Video B/W       IF B/W
                        QP                 120 kHz          300 kHz        120kHz

1GHz- 25GHz:

                       Measurement            Duty cycle       RBW         Video B/W
                           PK                    Any           1MHz          3 MHz
                                                >98%           1MHz          10 Hz
                            AV
                                                <98%           1MHz            1/T

Note: T is minimum transmission duration

If the maximized peak measured value complies with under the QP/Average limit more than 6dB, then it is
unnecessary to perform an QP/Average measurement.


Test Procedure

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

Data was recorded in Quasi-peak detection mode for frequency range of 30 MHz-1 GHz, peak and
Average detection modes for frequencies above 1 GHz.


Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit –Corrected Amplitude




                                                                                             Page 18 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG190426008-00A

Test Equipment List and Details

                                                                       Serial       Calibration    Calibration
    Manufacturer           Description             Model
                                                                     Number            Date         Due Date
        R&S            EMI Test Receiver          ESCI                100224        2018-12-10     2019-12-10
        Farad            Test Software          EZ-EMC               V1.1.4.2          N/A            N/A
    Sunol Sciences          Antenna                JB3              A060611-3       2017-07-21     2019-07-21
      Unknown            Coaxial Cable         C-NJNJ-50            C-1000-01       2018-09-05     2019-09-05
      Unknown            Coaxial Cable         C-NJNJ-50            C-0400-02       2018-09-05     2019-09-05
      Unknown            Coaxial Cable         C-NJNJ-50            C-0530-01       2018-09-24     2019-09-24
       Sonoma              Amplifier              310N                185914        2018-10-13     2019-10-13
       Agilent         Spectrum Analyzer         E4440A            SG43360054       2019-01-04     2020-01-04
    ETS-Lindgren         Horn Antenna             3115              000 527 35      2018-10-12     2021-10-12
                                             AFS42-00101800-
        MITEQ               Amplifier                                 2001271       2018-09-05     2019-09-05
                                                 25-S-42
       Unknown            Coaxial Cable         C-SJSJ-50           C-0800-01       2018-09-05     2019-09-05
       Unknown            Coaxial Cable       C-2.4J2.4J-50         C-0700-02       2018-06-27     2019-06-27
      Ducommun                                                      1007726-01
                          Horn Antenna         ARH-4223-02                          2016-11-18     2019-11-18
     Technolagies                                                      1304
       Quinstar             Amplifier       QLW-18405536-JO        15964001001      2018-06-27     2019-06-27
                                            OBSF-2400-2483.5-
     E-Microwave        Band-stop Filters                          OE01601525       2018-06-16     2019-06-16
                                                   S
     Micro-tronics       High Pass Filter      HPM50111              S/N-G217       2018-06-16     2019-06-16

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data

     Environmental Conditions

              Temperature:            24.0~27.2 oC
         Relative Humidity:             53~57%
            ATM Pressure:            99.8~ 100.7kPa


* The testing was performed by Vito Chen&Tyler Pan on 2019-04-29&2019-05-05

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table and plots.




                                                                                                    Page 19 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190426008-00A

1) 30MHz-1GHz (middle Channel was the worst):
Horizontal:




                  Receiver                     Correction     Cord.
   Frequency                                                               Limit        Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                               (dBuV/m)        (dB)
                  (dBuV)                        (dB/m)      (dBuV/m)
     66.8600       41.59           peak          -20.12       21.47        40.00         18.53
    193.9300       38.34           peak          -13.71       24.63        43.50         18.87
    301.6000       37.27           peak          -10.73       26.54        46.00         19.46
    376.2900       32.98           peak           -8.67       24.31        46.00         21.69
    469.4100       31.43           peak           -6.90       24.53        46.00         21.47
    563.5000       28.87           peak           -3.80       25.07        46.00         20.93




                                                                                        Page 20 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190426008-00A

Vertical:




                  Receiver                     Correction      Cord.
   Frequency                                                                Limit        Margin
                  Reading        Detector       Factor         Amp.
     (MHz)                                                                (dBuV/m)        (dB)
                  (dBuV)                        (dB/m)       (dBuV/m)

     35.8200        39.75          peak             -10.83    28.92         40.00         11.08
     55.2200        44.57          peak             -20.03    24.54         40.00         15.46
    118.2700        38.86          peak             -16.29    22.57         43.50         20.93
    155.1300        36.20          peak             -12.81    23.39         43.50         20.11
    305.4800        34.51          peak             -10.58    23.93         46.00         22.07
    963.1400        24.28          peak              1.93     26.21         54.00         27.79




                                                                                         Page 21 of 34


  Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190426008-00A

 2) 1-25GHz:

                  Receiver             Rx Antenna      Cable Amplifier   Corrected
Frequency                                                                              Limit      Margin
            Reading    Detector       Polar Factor       loss    Gain    Amplitude
  (MHz)                                                                              (dBμV/m)      (dB)
            (dBμV) (PK/QP/AV)         (H/V) (dB/m)      (dB)     (dB)    (dBμV/m)
                                          Low Channel: 2402 MHz
 2402.00      63.19         PK          H     28.10     1.80      0.00     93.09        N/A         N/A
 2402.00      62.34         AV          H     28.10     1.80      0.00     92.24        N/A         N/A
 2402.00      64.27         PK          V     28.10     1.80      0.00     94.17        N/A         N/A
 2402.00      63.69         AV          V     28.10     1.80      0.00     93.59        N/A         N/A
 2390.00      25.81         PK          V     28.08     1.80      0.00     55.69       74.00       18.31
 2390.00      14.77         AV          V     28.08     1.80      0.00     44.65       54.00        9.35
 4804.00      53.88         PK          V     32.91     3.17     37.20     52.76       74.00       21.24
 4804.00      48.68         AV          V     32.91     3.17     37.20     47.56       54.00        6.44
 7206.00      47.12         PK          V     35.74     4.82     37.23     50.45       74.00       23.55
 7206.00      38.65         AV          V     35.74     4.82     37.23     41.98       54.00       12.02
                                         Middle Channel: 2440 MHz
 2440.00      64.23         PK          H     28.18     1.82      0.00     94.23        N/A         N/A
 2440.00      63.54         AV          H     28.18     1.82      0.00     93.54        N/A         N/A
 2440.00      65.47         PK          V     28.18     1.82      0.00     95.47        N/A         N/A
 2440.00      64.74         AV          V     28.18     1.82      0.00     94.74        N/A         N/A
 4880.00      54.63         PK          V     33.06     3.27     37.21     53.75       74.00       20.25
 4880.00      49.36         AV          V     33.06     3.27     37.21     48.48       54.00        5.52
 7320.00      48.54         PK          V     36.03     4.62     37.37     51.82       74.00       22.18
 7320.00      39.33         AV          V     36.03     4.62     37.37     42.61       54.00       11.39
                                          High Channel: 2480 MHz
 2480.00      63.95         PK          H     28.26     1.84      0.00     94.05        N/A         N/A
 2480.00      63.21         AV          H     28.26     1.84      0.00     93.31        N/A         N/A
 2480.00      65.06         PK          V     28.26     1.84      0.00     95.16        N/A         N/A
 2480.00      64.37         AV          V     28.26     1.84      0.00     94.47        N/A         N/A
 2483.50      26.54         PK          V     28.27     1.84      0.00     56.65       74.00       17.35
 2483.50      17.99         AV          V     28.27     1.84      0.00     48.10       54.00        5.90
 4960.00      54.03         PK          V     33.22     3.23     37.25     53.23       74.00       20.77
 4960.00      48.87         AV          V     33.22     3.23     37.25     48.07       54.00        5.93
 7440.00      47.24         PK          V     36.34     4.41     37.52     50.47       74.00       23.53
 7440.00      38.75         AV          V     36.34     4.41     37.52     41.98       54.00       12.02




                                                                                          Page 22 of 34


     Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190426008-00A

    Worst plots (Middle Channel)
    Horizontal


Fundamental
Test with Band
Rejection Filter




                                                                          Page 23 of 34


     Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190426008-00A

    Vertical



Fundamental
Test with Band
Rejection Filter




                                                                          Page 24 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190426008-00A


FCC §15.247(a) (2) –6 dB EMISSION BANDWIDTH
Applicable Standard
According to FCC §15.247(a) (2)

Systems using digital modulation techniques may operate in the 902–928 MHz, 2400–2483.5 MHz, and
5725–5850 MHz bands. The minimum 6 dB bandwidth shall be at least 500 kHz.


Test Procedure

a) Set RBW = 100 kHz.
b) Set the video bandwidth (VBW) ≥ 3×RBW.
c) Detector = Peak.
d) Trace mode = max hold.
e) Sweep = auto couple.
f) Allow the trace to stabilize.
g) Measure the maximum width of the emission that is constrained by the frequencies associated with the
   two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB relative to the
   maximum level measured in the fundamental emission.


                                 EUT                                 Signal Analyzer



Test Equipment List and Details

                                                                     Serial       Calibration    Calibration
    Manufacturer            Description              Model
                                                                    Number           Date         Due Date

   Rohde & Schwarz        Signal Analyzer            FSIQ26       831929/005      2018-08-03      2019-08-03

       Unknown             Coaxial Cable         C-SJ00-0010       C0010/01        Each time         N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).

Test Data
     Environmental Conditions

              Temperature:                 26.8 C
         Relative Humidity:                58 %
            ATM Pressure:                 99.8 kPa

    * The testing was performed by Andy Huang on 2019-04-30
    Test Mode: Transmitting

   Test Result: Compliance. Please refer to the following table and plots.



                                                                                                    Page 25 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                            Report No.: RDG190426008-00A

                                                                  6 dB Emission
                                               Frequency                                        Limit
                       Channel                                      Bandwidth
                                                 (MHz)                                         (MHz)
                                                                      (MHz)
                         Low                     2402                  0.745                    ≥0.5
                        Middle                   2440                  0.745                    ≥0.5
                         High                    2480                  0.749                    ≥0.5



                                                           Low Channel
                                         Delta 1 [T1]               RBW   100 kHz     RF Att      30 dB
                       Ref Lvl                        -0.10 dB      VBW   300 kHz
                        20 dBm                 745.49098196 kHz     SWT    5 ms       Unit             dBm
                  20
                         0.5 dB Offset                                       1 [T1]             1.22 dBm
                                                                                                              A
                                                                                       2.40161323 GHz
                  10
                                                                             1 [T1]            -0.10 dB
                        D1 7.19 dBm
                                                 1                          1         745.49098196 kHz
                               D2 1.19 dBm
                   0



                 -10
                        1MAX                                                                                 1MA

                 -20



                 -30



                 -40



                 -50



                 -60



                 -70



                 -80
                       Center 2.402 GHz                      200 kHz/                         Span 2 MHz

                Date:            30.APR.2019    20:14:47




                                                                                                                   Page 26 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                             Report No.: RDG190426008-00A


                                                       Middle Channel
                                            Delta 1 [T1]             RBW   100 kHz     RF Att      30 dB
                       Ref Lvl                         -0.23 dB      VBW   300 kHz
                        20 dBm                  745.49098196 kHz     SWT    5 ms       Unit           dBm
                  20
                         0.5 dB Offset                                        1 [T1]             2.66 dBm
                                                                                                             A
                                                                                        2.43960922 GHz
                  10
                        D1 8.6 dBm                                            1 [T1]            -0.23 dB
                                                  1                          1         745.49098196 kHz
                               D2 2.6 dBm
                   0



                 -10
                        1MAX                                                                                1MA

                 -20



                 -30



                 -40



                 -50



                 -60



                 -70



                 -80
                       Center 2.44 GHz                        200 kHz/                         Span 2 MHz

                Date:            30.APR.2019    20:16:14

                                                           High Channel
                                            Delta 1 [T1]             RBW   100 kHz     RF Att      30 dB
                       Ref Lvl                         -0.15 dB      VBW   300 kHz
                        20 dBm                  749.49899800 kHz     SWT    5 ms       Unit           dBm
                  20
                         0.5 dB Offset                                        1 [T1]             2.59 dBm
                                                                                                             A
                                                                                        2.47960521 GHz
                  10
                        D1 8.62 dBm                                           1 [T1]            -0.15 dB
                                                  1                          1         749.49899800 kHz
                               D2 2.62 dBm
                   0



                 -10
                        1MAX                                                                                1MA

                 -20



                 -30



                 -40



                 -50



                 -60



                 -70



                 -80
                       Center 2.48 GHz                        200 kHz/                         Span 2 MHz

                Date:            30.APR.2019    20:20:32




                                                                                                                  Page 27 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190426008-00A

FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER
Applicable Standard
According to FCC §15.247(b) (3), for systems using digital modulation in the 902-928 MHz, 2400-2483.5
MHz, and 5725-5850 MHz bands: 1 Watt. As an alternative to a peak power measurement, compliance
with the one Watt limit can be based on a measurement of the maximum conducted output power.
Maximum Conducted Output Power is defined as the total transmit power delivered to all antennas and
antenna elements averaged across all symbols in the signaling alphabet when the transmitter is operating at
its maximum power control level. Power must be summed across all antennas and antenna elements. The
average must not include any time intervals during which the transmitter is off or is transmitting at a
reduced power level. If multiple modes of operation are possible (e.g., alternative modulation methods),
the maximum conducted output power is the highest total transmit power occurring in any mode.


Test Procedure
1. Place the EUT on a bench and set it in transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to test
   equipment.
3. Add a correction factor to the display.
4.

                                                                     USB Wideband
                                                                      Power Sensor
                                EUT



Test Equipment List and Details

                                                                   Serial         Calibration    Calibration
    Manufacturer           Description            Model
                                                                  Number             Date         Due Date

       Unknown            Coaxial Cable        C-SJ00-0010        C0010/01         Each time         N/A
                         USB Wideband
        Agilent                                 U2022XA         MY5417006         2018-12-10      2019-12-10
                          Power Sensor

  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                    Page 28 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190426008-00A


Test Data
     Environmental Conditions

              Temperature:             26.8 C
         Relative Humidity:            58 %
            ATM Pressure:             99.8 kPa

    * The testing was performed by Andy Huang on 2019-04-30


Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table.

                                                        Max Peak
                                      Frequency      Conducted Output    Limit
                       Channel
                                        (MHz)             Power         (dBm)
                                                          (dBm)
                         Low             2402              7.33           30
                        Middle           2440              8.80           30
                         High            2480              8.80           30




                                                                                         Page 29 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190426008-00A

FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE
Applicable Standard
According to FCC§15.247(d):In any 100 kHz bandwidth outside the frequency band in which the spread
spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is
produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the
band that contains the highest level of the desired power, based on either an RF conducted or a radiated
measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If
the transmitter complies with the conducted power limits based on the use of RMS averaging over a time
interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph
shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in §15.209(a) is not
required. In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must
also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)).


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect its
   antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured
   frequency within its operating range, and make sure the instrument is operated in its linear range.
3. Set RBW to 100 kHz and VBW of spectrum analyzer to 300 kHz with a convenient frequency span
   including 100 kHz bandwidth from band edge.
4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the
   graph with marking the highest point and edge frequency.
5. Repeat above procedures until all measured frequencies were complete.


Test Equipment List and Details

                                                                   Serial         Calibration    Calibration
    Manufacturer           Description              Model
                                                                  Number             Date         Due Date

   Rohde & Schwarz       Signal Analyzer            FSIQ26       831929/005       2018-08-03      2019-08-03

       Unknown            Coaxial Cable         C-SJ00-0010       C0010/01         Each time         N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

              Temperature:                26.8 C
         Relative Humidity:               58 %
            ATM Pressure:                99.8 kPa

    * The testing was performed by Andy Huang on 2019-04-30
Test mode: Transmitting
Test Result: Compliance. Please refer to following plots.

                                                                                                    Page 30 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                                 Report No.: RDG190426008-00A

                                                  Band Edge, Left Side
                                        Marker 2 [T1]                    RBW   100 kHz     RF Att      30 dB
                       Ref Lvl                      -41.55 dBm           VBW   300 kHz
                        20 dBm                  2.40000000 GHz           SWT    5 ms       Unit           dBm
                  20
                         0.5 dB Offset                                            2 [T1]           -41.55 dBm
                                                                                                                 A
                                                                                            2.40000000 GHz
                  10                                                                   1
                                                                                  1 [T1]             7.18 dBm
                                                                                            2.40201202 GHz
                   0



                 -10
                        -12.82dBm
                        1MAX                                                                                    1MA

                 -20



                 -30



                 -40                                             2



                 -50



                 -60



                 -70



                 -80
                       Center 2.4 GHz                      800 kHz/                                Span 8 MHz

                Date:          30.APR.2019     20:15:45

                                                 Band Edge, Right Side
                                        Marker 2 [T1]                    RBW   100 kHz     RF Att      30 dB
                       Ref Lvl                      -49.56 dBm           VBW   300 kHz
                        20 dBm                  2.48401904 GHz           SWT    5 ms       Unit           dBm
                  20
                         0.5 dB Offset                                            2 [T1]           -49.56 dBm
                                                                                                                 A
                                                                                            2.48401904 GHz
                                           1              -11.40dBm
                  10
                                                                                  1 [T1]             8.60 dBm
                                                                                            2.48000701 GHz
                   0



                 -10
                        1MAX                                                                                    1MA

                 -20



                 -30



                 -40


                                                                     2
                 -50



                 -60



                 -70



                 -80
                       Center 2.4835 GHz                   1.4 MHz/                               Span 14 MHz

                Date:          30.APR.2019     20:21:28




                                                                                                                      Page 31 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                Report No.: RDG190426008-00A

FCC §15.247(e) - POWER SPECTRAL DENSITY
Applicable Standard
According to FCC§15.247(e):For digitally modulated systems, the power spectral density conducted from
the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time
interval of continuous transmission. This power spectral density shall be determined in accordance with
the provisions of paragraph (b) of this section. The same method of determining the conducted output
power shall be used to determine the power spectral density.


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT was set without connection to measurement instrument. Turn on the EUT and
   connect its antenna terminal to measurement instrument via a low loss cable. Then set it to any one
   measured frequency within its operating range, and make sure the instrument is operated in its linear
   range.
3. Set the RBW = 3 kHz, VBW = 10 kHz, Set the span to 1.5 times the DTS bandwidth.
4. Use the peak marker function to determine the maximum amplitude level.


Test Equipment List and Details

                                                                      Serial       Calibration   Calibration
     Manufacturer            Description              Model
                                                                     Number           Date        Due Date

   Rohde & Schwarz         Signal Analyzer            FSIQ26        831929/005     2018-08-03     2019-08-03

        Unknown             Coaxial Cable         C-SJ00-0010        C0010/01       Each time        N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

               Temperature:                 26.8 C
         Relative Humidity:                 58 %
            ATM Pressure:                  99.8 kPa

     * The testing was performed by Andy Huang on 2019-04-30


Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table and plots




                                                                                                    Page 32 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                        Report No.: RDG190426008-00A

                                                               Power Spectral
                                             Frequency                                 Limit
                         Channel                                  Density
                                               (MHz)                                (dBm/3kHz)
                                                                (dBm/3kHz)
                           Low                  2402               -8.03                   ≤8
                          Middle                2440               -6.60                   ≤8
                          High                  2480               -6.45                   ≤8



                                     Power Spectral Density, Low Channel
                                       Marker 1 [T1]            RBW    3 kHz      RF Att      30 dB
                       Ref Lvl                     -8.03 dBm    VBW   10 kHz
                        20 dBm                2.40197872 GHz    SWT   320 ms      Unit           dBm
                  20
                         0.5 dB Offset                                   1 [T1]            -8.03 dBm
                                                                                                        A
                                                                                   2.40197872 GHz
                  10



                   0

                                                           1
                 -10
                        1MAX                                                                           1MA

                 -20



                 -30



                 -40



                 -50



                 -60



                 -70



                 -80
                       Center 2.402 GHz                 111.75 kHz/               Span 1.1175 MHz

                Date:          30.APR.2019   20:15:22




                                                                                                             Page 33 of 34


Bay Area Compliance Laboratories Corp. (Dongguan)                                        Report No.: RDG190426008-00A


                                    Power Spectral Density, Middle Channel
                                       Marker 1 [T1]            RBW    3 kHz      RF Att      30 dB
                       Ref Lvl                     -6.60 dBm    VBW   10 kHz
                        20 dBm                2.43997872 GHz    SWT   320 ms      Unit           dBm
                  20
                         0.5 dB Offset                                   1 [T1]            -6.60 dBm
                                                                                                        A
                                                                                   2.43997872 GHz
                  10



                   0
                                                           1

                 -10
                        1MAX                                                                           1MA

                 -20



                 -30



                 -40



                 -50



                 -60



                 -70



                 -80
                       Center 2.44 GHz                  111.75 kHz/               Span 1.1175 MHz

                Date:          30.APR.2019   20:16:52

                                     Power Spectral Density, High Channel
                                       Marker 1 [T1]            RBW    3 kHz      RF Att      30 dB
                       Ref Lvl                     -6.45 dBm    VBW   10 kHz
                        20 dBm                2.47997861 GHz    SWT   320 ms      Unit           dBm
                  20
                         0.5 dB Offset                                   1 [T1]            -6.45 dBm
                                                                                                        A
                                                                                   2.47997861 GHz
                  10



                   0
                                                           1

                 -10
                        1MAX                                                                           1MA

                 -20



                 -30



                 -40



                 -50



                 -60



                 -70



                 -80
                       Center 2.48 GHz                  112.35 kHz/               Span 1.1235 MHz

                Date:          30.APR.2019   20:21:04



                                         ***** END OF REPORT *****

                                                                                                             Page 34 of 34