MTi19070908-3E2-Exposure

FCC ID: 2AMBHRW1701

RF Exposure Info

Download: PDF
FCCID_4444834

                      EXPOSURE
                      REPORT

                      FCC ID: 2AMBHRW1701


                      Date of issue: Aug. 16, 2019

Report Number:        MTi19070908-3E2


Sample Description:   Wireless Charger


Model(s):             RW1701


Applicant:            Republic Wireless, Inc.


Address:              940 Main Campus Drive, Ste 300, Raleigh, NC, 27606 USA


Date of Test:         Aug. 09, 2019 – Aug. 16, 2019




                      Shenzhen Microtest Co., Ltd.
                         http://www.mtitest.com


                                       Table of Contents


  Applicant’s name:            Republic Wireless, Inc.


  Address:                     940 Main Campus Drive, Ste 300, Raleigh, NC, 27606 USA


  Manufacture's name:          Shenzhen Aodehong Electronic Technology Co., Ltd

                               4/F, A1 Bldg., Xiangdali Industrial Zong, Hengping RD.No.87,
  Address:
                               Henggang St., Longgang Dist, Shenzhen

  Product name:                Wireless Charger

  Trademark:                   N/A


  Model name:                  RW1701


  Standard:                    FCC CFR 47 PART 1 , 1.1310


  RF Exposure Procedures:      KDB 680106 D01 RF Exposure Wireless Charging App v03



This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results
show that the equipment under test (EUT) compliance with the FCC requirements. And it is applicable
only to the tested sample identified in the report.




                 Tested by:


                                                  Demi Mu                   Aug. 16, 2019


                Reviewed by:


                                                  Blue Zheng                Aug. 16, 2019

               Approved by:

                                                  Smith Chen                Aug. 16, 2019


1 General Information
1.1 Description of EUT

    Product name:                Wireless Charger

    Brand name:                  N/A

    Model name:                  RW1701

    Series model:                N/A

    Deference in serial model:   N/A

    Operation frequency:         115–205 kHz

    Operational mode:            Wireless charging

    Modulation type:             Load modulation

    Antenna type:                Coil Antenna

    Power source:                DC 5V or 9V from adapter

    Battery:                     N/A

    Adapter information:         N/A


1.2 Ancillary equipment list

          Equipment                Model                 S/N           Manufacturer

                                                                 Huizhou Dongyang Yienbi
           Adapter               EQ-24BCN                   /
                                                                   Electronics Co., Ltd.

               Load                    /                    /               /


1.3 Measurement uncertainty

Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y)

     Radiated emission(150kHz~30MHz)                 ± 2.5 dB
     Radiated emission(30MHz~1GHz)                   ± 4.2 dB
     Radiated emission (above 1GHz)                  ± 4.3 dB
     Temperature                                     ±1 degree
     Humidity                                        ±5 %


2 Testing site
   Test Site               Shenzhen Microtest Co., Ltd

                           No.102A & 302A, East Block, Hengfang Industrial Park, Xingye
   Test Site Location
                           Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China

   FCC Registration No.:   448573


3 List of test equipment
 Equipment     Equipment                                       Serial      Calibration
                                 Manufacturer      Model                                   Due date
 No.           Name                                            No.         date

                                 Narda Safety
               Broadband                           NBM-
 MTI-E068                        Test Solutions                D-1699       2019/4/17      2021/4/16
               Field Meter                         520
                                 GmbH

                                 Narda Safety
 MTI-E069      Probe E-Field                       EF0691      H-0571       2019/4/17      2021/4/16
                                 Test Solutions



Note: the calibration interval of the above test instruments is 12 or 24 months and the calibrations are
traceable to international system unit (SI).


4 Test Results
4.4 Maximum permissible exposure

4.4.1        Limit


    Frequency           Electric field       Magnetic field            Power            Averaging
   range(MHz)          strength(V/m)         strength(A/m)        density(mW/cm2)     time(minutes)

                           (A) Limits for Occupational/Controlled Exposure
    0.3-3.0                 614                 1.63                 *100                    6
     3.0-30               1842/f               4.89/f               *900/f2                  6
    30-300                 61.4                0.163                 1.0 6                   6
   300-1500                                                          f/300                   6
  1500-100000                                                           5                    6
                       (B) Limits for General Population/Uncontrolled Exposure
      0.3-1.34              614                 1.63                 *100                   30
      1.34-30              824/f               2.19/f               *180/f2                 30
       30-300              27.5                0.073                   0.2                  30
     300-1500                                                       f/1500                  30
   1500-100000                                                          1                   30
f = frequency in MHz * = Plane-wave equivalent power density

4.4.2        Test Procedures

E and H-field measurements should be made with the center of the probe at a distance of 15 cm
surrounding the device and 20 cm above the top surface of the primary/client pair.

These measurements should be repeated for three different client battery levels, 1%, 50%, and 99%.

Record the test results.

KDB 680106 D01 RF Exposure Wireless Charging App v03:

(1) Power transfer frequency is less than 1MHz.

(2) Output power from each primary coil is less than or equal to 15 watts.

(3) The transfer system includes only single primary and secondary coils. This includes charging
systems that may have multiple primary coils and clients that are able to detect and allow coupling
only between individual pairs of coils.

(4) Client device is placed directly in contact with the transmitter.

(5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion).

(6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top
surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE
limit.

Note: The device is in compliance with KDB 680106 D01 RF Exposure Wireless Charging App v03 6
conditions.


4.4.3   Test Setup


                                              Top Side


                                                            Back Side




                     Left Side
                                                                   15cm
                                                                              Field Probe
                                                                 Right Side




                                 Front Side

                                              Bottom Side


4.4.4   Test Result

                            Maximum permissible Exposure
          Battery                             Test          E–
                        Test sides                                   H–field(A/m)
          levels                         distance(cm)   field(V/m)
           <1%             Top                 20          0.417        0.115
           <1%            Bottom               15          0.421        0.110
           <1%              Left               15          0.424        0.114
           <1%             Right               15          0.426        0.108
           <1%             Front               15          0.419        0.105
           <1%             Back                15          0.414        0.103
                           Limit                           614          1.63
                      Margin Limit (%)                   0.069%        7.06%


                            Maximum permissible Exposure
          Battery                             Test          E–
                        Test sides                                   H–field(A/m)
          levels                         distance(cm)   field(V/m)
          <50%             Top                 20          0.420        0.122
          <50%            Bottom               15          0.407        0.116
          <50%              Left               15          0.413        0.112
          <50%             Right               15          0.419        0.109
          <50%             Front               15          0.417        0.111
          <50%             Back                15          0.423        0.107
                           Limit                           614          1.63
                      Margin Limit (%)                   0.069%        7.48%


                            Maximum permissible Exposure
          Battery                             Test          E–
                        Test sides                                   H–field(A/m)
          levels                         distance(cm)   field(V/m)
          <99%             Top                 20          0.430        0.118
          <99%            Bottom               15          0.427        0.108
          <99%              Left               15          0.422        0.105
          <99%             Right               15          0.418        0.125
          <99%             Front               15          0.421        0.112
          <99%             Back                15          0.416        0.105
                           Limit                           614          1.63
                      Margin Limit (%)                   0.070%        7.66%


4.4.5   MPE Setup photo




                          ----END OF REPORT----