CCISE190906306V01 FCC 15B class B

FCC ID: 2AM86W-V800

Test Report

Download: PDF
FCCID_4502310

                          Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                           Report No: CCISE190906306V01

1        Cover Page

                                      FCC REPORT
Applicant:                                 Wiko SAS

Address of Applicant:                      1, rue Capitaine Dessemond – 13007 Marseille – France.

Equipment Under Test (EUT)

    Product Name:                          Mobile Phone

    Model No.:                             W-V800

    Trade mark:                            WIKO

FCC ID:                                    2AM86W-V800

Applicable standards:                      FCC CFR Title 47 Part 15 Subpart B

Date of sample receipt:                    17 Sep., 2019

Date of Test:                              18 Sep., to 14 Oct., 2019

Date of report issued:                     31 Oct., 2019

Test Result:                               PASS *
  * In the configuration tested, the EUT complied with the standards specified above.




 Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.


                                                                             Report No: CCISE190906306V01

2      Version
      Version No.                            Date                                 Description
             00                         15 Oct., 2019                               Original
             01                         31 Oct., 2019                            Update Page 6




    Tested by:                                                           Date:         31 Oct., 2019

                                       Test Engineer

    Reviewed by:                                                         Date:         31 Oct., 2019

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1909063
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                         Page 2 of 18


                                                                                                                    Report No: CCISE190906306V01

3         Contents
                                                                                                                                                                                 Page
1     COVER PAGE ....................................................................................................................................................... 1
2     VERSION ............................................................................................................................................................... 2
3     CONTENTS ........................................................................................................................................................... 3
4     TEST SUMMARY .................................................................................................................................................. 4
5     GENERAL INFORMATION .................................................................................................................................. 5
    5.1    CLIENT INFORMATION ...................................................................................................................................................... 5
    5.2    GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
    5.3    TEST MODE.................................................................................................................................................................... 5
    5.4    MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
    5.5    DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
    5.6    RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................... 6
    5.7    DESCRIPTION OF CABLE USED ............................................................................................................................................ 6
    5.8    ADDITIONS TO, DEVIATIONS, OR EXCLUSIONS FROM THE METHOD ............................................................................................. 6
    5.9    LABORATORY FACILITY ...................................................................................................................................................... 6
    5.10      LABORATORY LOCATION............................................................................................................................................... 6
    5.11      TEST INSTRUMENTS LIST ............................................................................................................................................... 7
6     TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1    CONDUCTED EMISSION ..................................................................................................................................................... 8
    6.2    RADIATED EMISSION ...................................................................................................................................................... 11
7     TEST SETUP PHOTO ........................................................................................................................................ 17
8     EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 18




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                               Project No.: CCISE1909063
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                                        Page 3 of 18


                                                                            Report No: CCISE190906306V01

4      Test Summary
                 Test Item                                Section in CFR 47                   Result
           Conducted Emission                                 Part 15.107                      Pass
            Radiated Emission                                 Part 15.109                      Pass
 Remark:
 1. Pass: The EUT complies with the essential requirements in the standard.
 2. N/A: The EUT not applicable of the test item.
 Test Method:  ANSI C63.4:2014




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1909063
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                        Page 4 of 18


                                                                         Report No: CCISE190906306V01

5      General Information
5.1 Client Information
        Applicant:                              Wiko SAS
        Address:                                1, rue Capitaine Dessemond – 13007 Marseille – France.
        Manufacturer/Factory:                   Shenzhen Tinno Mobile Technology Corp.
        Address:                                4/F, H-3 Building, OCT Eastern lndustrial Park. NO.1 XiangShan
                                                East Road, Nan Shan District, Shenzhen, P.R. China.

5.2 General Description of E.U.T.
        Product Name:                           Mobile Phone
        Model No.:                              W-V800
        Hardware version:                       V1.0
        Software version:                       W-V800-CA-V01.07-20-9.0-GBL
        Power supply:                           Rechargeable Li-ion Battery DC3.85V-3900mAh
                                                Input: AC100-240V, 50/60Hz, 250mA
        AC adapter :
                                                Output: DC 5.0V, 1.55A
        Test Sample Condition:                  The test samples were provided in good working order with no
                                                visible defects.

5.3 Test Mode
           Operating mode               Detail description
              PC mode                   Keep the EUT in Downloading mode(Worst case)
    Charging+Recording mode             Keep the EUT in Charging+Recording mode
      Charging+Playing mode             Keep the EUT in Charging+Playing mode
              FM mode                   Keep the EUT in FM receiver mode
            GPS mode                  Keep the EUT in GPS receiver mode
 The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
 vertical polarities were performed. During the test, each emission was maximized by: having the EUT
 continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
 typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable,
 varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case
 are shown in Test Results of the following pages.

5.4 Measurement Uncertainty
                    Parameters                                            Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                    ±1.60 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                    ±3.12 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                   ±4.32 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                     ±5.38 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                    ±3.36 dB (k=2)




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1909063
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                          Page 5 of 18


CCIS                                                                        Report No: CCISE190906306V01

5.5 Description of Support Units
      Manufacturer                Description                 Model          Serial Number          FCC ID/DoC

            DELL                       PC                 OPTIPLEX745              N/A                  DoC
            DELL                   MONITOR                   E178FPC               N/A                  DoC
            DELL                  KEYBOARD                   SK—8115               N/A                  DoC
            DELL                    MOUSE                    MOCSUO                N/A                  DoC
        LENOVO                       Laptop                   SL510              2B47A65                DoC
            HP                       Printer           HP LaserJet P1007           N/A                  DoC

5.6 Related Submittal(s) / Grant (s)
       This is an original grant, no related submittals and grants.

5.7 Description of Cable Used
        Cable Type                     Description                 Length           From                 To
   Detached USB Cable                    Shielding                  1.0m             EUT             PC/Adapter
  Detached headset cable                Unshielded                  1.2m             EUT              Headset

5.8 Additions to, deviations, or exclusions from the method
       No


5.9 Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
        ® FCC — Designation No.: CN1211
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by
       FCC(Federal Communications Commission). The test firm Registration No. is 727551.
        ®@ ISED — CAB identifier.: CNOO21
       The 3m Semi—anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
        Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
        Registration No.: 10106A—1.
        ® CNAS — Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.
        ®    A2LA — Registration No.: 4346.01
        This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
        17025:2005 General requirements for the competence of testing and calibration laboratories. The test
        scope can be found as below link: https://portal.a2la.org/scopepdf/4346—0 L.pdf

5.10 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bac‘an District, Shenzhen, Guangdong, China
        Tel: +86—755—23118282, Fax: +86—755—23116366
        Email: info@ccis—cb.com, Website: http://www.ccis—cb.com




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1909063
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 6 of 18


                                                                             Report No: CCISE190906306V01

5.11 Test Instruments list
 Radiated Emission:
                                                                                           Cal. Date        Cal. Due date
    Test Equipment            Manufacturer             Model No.          Serial No.
                                                                                          (mm-dd-yy)         (mm-dd-yy)
        3m SAC                  SAEMC                  9m*6m*6m               966         07-22-2017         07-21-2020
     Loop Antenna            SCHWARZBECK              FMZB1519B             00044         03-18-2019         03-17-2020
   BiConiLog Antenna         SCHWARZBECK               VULB9163               497         03-18-2019         03-17-2020
     Horn Antenna            SCHWARZBECK              BBHA9120D               916         03-18-2019         03-17-2020
     Horn Antenna            SCHWARZBECK              BBHA9120D              1805         06-22-2017         06-21-2020
     Horn Antenna            SCHWARZBECK              BBHA 9170          BBHA9170582      11-21-2018         11-20-2019
   EMI Test Software             AUDIX                    E3                           Version: 6.110919b
     Pre-amplifier                 HP                   8447D            2944A09358       03-18-2019         03-17-2020
     Pre-amplifier                 CD                  PAP-1G18             11804         03-18-2019         03-17-2020
   Spectrum analyzer         Rohde & Schwarz            FSP30              101454         03-18-2019         03-17-2020
   Spectrum analyzer         Rohde & Schwarz            FSP40              100363         11-21-2018         11-20-2019
   EMI Test Receiver         Rohde & Schwarz           ESRP7                101070        03-18-2019         03-17-2020
        Cable                    ZDECL              Z108-NJ-NJ-81          1608458        03-18-2019         03-17-2020
        Cable                 MICRO-COAX              MFR64639             K10742-5       03-18-2019         03-17-2020
        Cable                   SUHNER              SUCOFLEX100           58193/4PE       03-18-2019         03-17-2020


 Conducted Emission:
                                                                                         Cal. Date          Cal. Due date
   Test Equipment             Manufacturer            Model No.           Serial No.
                                                                                        (mm-dd-yy)           (mm-dd-yy)
  EMI Test Receiver         Rohde & Schwarz             ESCI               101189       03-18-2019           03-17-2020
    Pulse Limiter           SCHWARZBECK              OSRAM 2306             9731        03-18-2019           03-17-2020
        LISN                    CHASE                 MN2050D               1447        03-18-2019           03-17-2020
        LISN                Rohde & Schwarz           ESH3-Z5            8438621/010    07-21-2018           07-20-2021
       Cable                      HP                   10503A                N/A        03-18-2019           03-17-2020
  EMI Test Software             AUDIX                    E3                          Version: 6.110919b




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1909063
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                  Page 7 of 18


                                                                            Report No: CCISE190906306V01

6      Test results and Measurement Data
6.1 Conducted Emission
       Test Requirement:                FCC Part 15 B Section 15.107
       Test Frequency Range:            150kHz to 30MHz
       Class / Severity:                Class B                  Class B
       Receiver setup:                  RBW=9kHz, VBW=30kHz
       Limit:                                                                        Limit (dBµV)
                                          Frequency range (MHz)
                                                                          Quasi-peak                Average
                                                 0.15-0.5                   66 to 56*               56 to 46*
                                                   0.5-5                       56                      46
                                                  0.5-30                       60                      50
                                        * Decreases with the logarithm of the frequency.
       Test setup:




       Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                           line impedance stabilization network(L.I.S.N.). The provide a
                                           50ohm/50uH coupling impedance for the measuring equipment.
                                        2. The peripheral devices are also connected to the main power through a
                                           LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                           termination. (Please refers to the block diagram of the test setup and
                                           photographs).
                                        3. Both sides of A.C. line are checked for maximum conducted
                                           interference. In order to find the maximum emission, the relative
                                           positions of equipment and all of the interface cables must be changed
                                           according to ANSI C63.4: 2014 on conducted measurement.
       Test Instruments:                Refer to section 5.11 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Pass




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1909063
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 8 of 18


CCIS                                                                             Report No: CCISE190906306V01

Measurement data:
 Product name:                     Mobile Phone                   Product model:           W—v800

 Test by:                          Yaro                           Test mode:               PC mode

 Test frequency:                   150 kHz ~ 30 MHz               Phase:                   Line

 Test voltage:                     AC 120 V/60 Hz                 Environment:             Temp: 22.5°C            Huni: 55%


             3 Level (dBuy)

             70
             60\
                                                                                                   FCC PART15 B oP

             50\1\3\                          3                                                    FCC PART15 B AV
                                   ~~_


             40                               |M                                          *
             solt—)  t —f
               | \ \" blh
                                              i
                                              W
                                                             id                                        nlfe
             20    'vq

             10                                                                                                      *

                  A5 .2                   5           1           2                5          10              20      30
        Trace: 3                                           Frequency (MHz)



                                      Read   LISN          Cable                 Limit      Over
                           Freq      Level Factor           Loss      Level       Line     Limit Remark

              """MHz dBu¥ —db _dB dBu¥v dBu¥ _db —%=—
         1                0. 190     38.33         —0.42   10.76      48.67      64.02    —15.35      QP
         2                0. 190     24.21         —0.42   10.76      34.55      54.02    —19.47      Average
         3                0.222      36.18         —0.40   10.76      46.54      62.74    —16.20      QP
         4                0.538      37.39         —0.39   10.76      4T.76      56.00     —8.24      QP
         5                0.538      27.12         —0.39   10.76      37.49      46.00     —8.51      Average
         6                0.567      35.16         —0.39   10.76      45.53      56.00    —10.47      QP
         T                0.567      24.14         —0.39   10.76      34.51      46.00    —11.49      Average
         8                0.601      34.48         —0.38   10.77      44.87      56.00    —11.13      QP
         9                1.016      17.98         —0.38   10.87      28.47      46.00    —17.53      Average
        10                1.671      15.82         —0.40   10.94      26.36      46.00    —19.64      Average
        11                8.822      28.90         —O.58   10.89      39.21      60.00    —20.79      QP
        12               17.291      20.49         —0.82   10.91      30.58      50.00    —19.42      Average


 Notes:
 1. An initial pre—scan was performed on the line and neutral lines with peak detector.
 2.   Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                  Project No.: CCISE1909063
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                        Page 9 of 18


CCIS                                                                           Report No: CCISE190906306V01


 Product name:                 Mobile Phone                    Product model:              w—vBoo

Test by:                       Yaro                            Test mode:                  PC mode

Test frequency:                150 kHz ~ 30 MHz                Phase:                      Neutral

Test voltage:                  AC 120 V/60 Hz                  Environment:                Temp: 22.5°C         Huni: 55%


            8oLevel (dBuV)


            70

            so\                                                                                      FCC PaRT1s 8 oP
                                                                                                 FCC PART15B AV
            50|
            40
            30|
            20
            10



                                                         Frequency (MHz)
      Trace: 1


                                 Read   LISN           Cable                   Limit        Over
                      Freq      Level Factor            Loss        Level       Line       Limit Remark

                  ______MHz dBu¥y _dB _db dBu¥ dBu¥ _db —%=——
        1            0. 1568    40.05         —0.68     10.77       50.14      65.56      —15.42      QP
        2            0. 158     26.45         —O.68     10.77       36.54      55.56      —19.02      Average
        3            0.222      39.20         —O.67     10.76       49.29      62.74      —13.45      QP
        4            0.222      24.71         —O.67     10.76       34.80      52.74      —17.94      Average
        5            0.538      39.66         —0.65     10.76       49.77      56.00       —6.23      QP
        6            0.538      32.48         —O0.65    10.76       42.59      46.00       —3.41      Average
        T            0.567      33.61         —0.65     10.76       43.72      56.00      —12.28      QP
        8            0.570      24.91         —O.65     10.176      35.02      46.00      —10.98      Average
        9            0.601      23.28         —0.64     10.77       33.41      46.00      —12.59      Average
       10            1.136      29.36         —O.64     10.89       39.61      56.00      —16.39      QP
       11            9. 362     31.22         —0.78     10.91       41.35      60.00      —18. 65     QP
       12           17.755      23.70         —1.16     10.92       33.46      50.00      —16.54      Average

 Notes:
 1. An initial pre—scan was performed on the line and neutral lines with peak detector.
 2.   Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1909063
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                    Page 10 of 18


                                                                         Report No: CCISE190906306V01

6.2 Radiated Emission
        Test Requirement:             FCC Part 15 B Section 15.109
        Test Frequency Range:         30MHz to 6000MHz
        Test site:                    Measurement Distance: 3m (Semi-Anechoic Chamber)
        Receiver setup:                 Frequency       Detector        RBW      VBW               Remark
                                       30MHz-1GHz      Quasi-peak      120kHz   300kHz        Quasi-peak Value
                                                         Peak           1MHz     3MHz           Peak Value
                                       Above 1GHz
                                                         RMS            1MHz     3MHz          Average Value
        Limit:                               Frequency           Limit (dBuV/m @3m)              Remark
                                           30MHz-88MHz                    40.0               Quasi-peak Value
                                          88MHz-216MHz                    43.5               Quasi-peak Value
                                          216MHz-960MHz                   46.0               Quasi-peak Value
                                           960MHz-1GHz                    54.0               Quasi-peak Value
                                                                          54.0                Average Value
                                            Above 1GHz
                                                                          74.0                 Peak Value
        Test setup:                   Below 1GHz




                                      Above 1GHz




        Test Procedure:               1. The EUT was placed on the top of a rotating table 0.8 meters above the
                                         ground at a 3 meter semi-anechoic camber. The table was rotated 360
                                         degrees to determine the position of the highest radiation.
                                      2. The EUT was set 3 meters away from the interference-receiving antenna,
                                         which was mounted on the top of a variable-height antenna tower.
                                      3. The antenna height is varied from one meter to four meters above the
                                         ground to determine the maximum value of the field strength. Both
                                         horizontal and vertical polarizations of the antenna are set to make the
                                         measurement.

Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1909063
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                          Page 11 of 18


                                                                          Report No: CCISE190906306V01

                                      4. For each suspected emission, the EUT was arranged to its worst case
                                         and then the antenna was tuned to heights from 1 meter to 4 meters and
                                         the rotatable table was turned from 0 degrees to 360 degrees to find the
                                         maximum reading.
                                      5. The test-receiver system was set to Peak Detect Function and Specified
                                         Bandwidth with Maximum Hold Mode.
                                      6. If the emission level of the EUT in peak mode was 10dB lower than the
                                         limit specified, then testing could be stopped and the peak values of the
                                         EUT would be reported. Otherwise the emissions that did not have 10dB
                                         margin would be re-tested one by one using peak, quasi-peak or average
                                         method as specified and then reported in a data sheet.
        Test Instruments:             Refer to section 5.11 for details
        Test mode:                    Refer to section 5.3 for details
        Test results:                 Passed
        Remark:                       All of the observed value above 6GHz ware the niose floor , which were no
                                      recorded




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1909063
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                           Page 12 of 18


c c I s                                                                           Report No: CCISE190906306V01

Measurement Data:
Below 1GHz:

 Product Name:                Mobile Phone                            Product Model:            w—vBo0

Test By:                      Yaro                                    Test mode:                PC mode

Test Frequency:               30 MHz ~1 GHz                           Polarization:             Vertical

Test Voltage:                 AC 120/60Hz                             Environment:              Temp: 24°C      Huni: 57%


        80Level (dBuVim)


        70

        60
                                                                                               FCC PART15 CLAS$ B
        50




             30          50                   100                 200                          500              1000
                                                        Frequency (MHz)


                                Read&ntenna         Cable Preamp                   Limit        Over
                     Freq      Level Factor          Loss Factor         Level      Line      Limit Remark

                      MHz       dBu¥        dB/m        dB        dB dBu¥/m dBu¥/nm                  dB
        1         163.756      54.26      9.42       2.62     29.10       37.20    43.50     —6.30        QP
        2         178.758      51.90      9.93       2.72     28.98       35.57    43.50     —7.93        QP
        3         284.977      47.03     13.35       2.90     28.48       34.80    46.00    —11.20        QP
        4         360.448      43.14     14.75       3.10     28.61       32.38    46.00    —13.62        QP
        5         480.528      39.93     17.52       3.46     28.92       31.99    46.00    —14.01        QP
        6         560.693      36.18     18.62       3.90     29.07       29.63    46.00    —16.37        QP


 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1909063
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                    Page 13 of 18


CCIS                                                                             Report No: CCISE190906306V01


 Product Name:               Mobile Phone                            Product Model:             W—v800

 Test By:                    Yaro                                    Test mode:                 PC mode

 Test Frequency:             30 MHz ~ 1 GHz                          Polarization:              Horizontal

 Test Voltage:               AC 120/60Hz                             Environment:               Temp: 24°C     Huni: 57%


        80level (dBuVim)


        70

        60
                                                                                              FCC PART1S CLAS$ 8
        50

        40

        30

        20

        10


             30         50                    100                200                          500              1000
                                                       Frequency (MHz)


                              ReadAntenna           Cable Preamp                     Limit      Over
                    Freq     Level Factor            Loss Factor         Level        Line     Limit Remark

                     WHz       dbu¥y     db/m           dB        db dBu¥/m dBu¥/m                  db
       1          178.133 54.31          9.91        2.71     28.99 37.94 43.50 —5.56 qPr
       20         268.485 50.71         13.06        2.86     28.51 38.12 46.00 —7.88 qPr
       3           285.978 53.32        13.37        2.90     28.47 41.12 46.00 —4.88 QP
       4           361.714 47.01        14.78        3.10     28.61 36.28 46.00 —9.72 qP
       §           480.528 39.41        17.52        3.46     28.92 31.47 46.00 —14.53 QP
       6           T39.661 36.29        20.56        4.32     28.52 32.65 46.00 —13.35 QP

 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lowerthan the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE1909063
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                   Page 14 of 18


c c I s                                                                          Report No: CCISE190906306V01

Above 1GHz:
 Product Name:               Mobile Phone                             Product Model:              w—vBoo

 Test By:                    Yaro                                     Test mode:                  PC mode

 Test Frequency:             1 GHz ~ 6 GHz                            Polarization:               Vertical

 Test Voltage:               AC 120/60Hz                              Environment:                Temp: 24°C            Huni: 57%


         8o Level (dBuVim)
                                                                                                     FCC PART 15 (PK)
         70

         60
                                                                                                     FCC PART 15 (AV)
         50                                                                                   q
                                                                                                         5
                                                                                                         3
                                                                                                                    5

         40

         30

         20

         10


              1000   1200           1500           2000                                                      5000       6000
                                                          Frequency (MHz)


                               Readintenna         Cable Preamp                  Limit       Over
                     Freq     Level Factor          Loss Factor        Level      Line     Limit Remark

               """""NBz dBuy dB/mdbdb dBu¥/m dBu¥/m                                           db —
         1      3973.530      47.52        30.19    6.11     41.81     44.21     74.00    —29.79     Peak
         2       3973.530     39.52        30.19    6.11     41.81     36.21     54.00    —17.79     Average
         3      4685.613      48.08        30.78    6.86     42.01     46.12     74.00    —27.88     Peak
         4       4685.613     40.03        30.78    6.86     42.01     38.07     54.00    —15.93     Average
         5       5555.085     47.76        32.61    7.26     41.81     48.48     74.00    —25.52     Peak
         6       §555.085     39.75        32.61    7.26     41.81     40.47     54.00    —13.53     Average


 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preampiifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1909063
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                         Page 15 of 18


CCIS                                                                              Report No: CCISE190906306V01


 Product Name:                 Mobile Phone                             Product Model:          w—vBo0

Test By:                       Yaro                                     Test mode:              PC mode

Test Frequency:                1 GHz ~6 GHz                             Polarization:           Horizontal

Test Voltage:                  AC 120/60Hz                              Environment:            Temp: 24°C           Huni: 57%


         8[]Le\.'el (dBuVim)
                                                                                                        FCC PART 15 (PK)
         70

         60
                                                                                                        FCC PART 15 (AV)
         50                                                                                         3           4     5


         40

         30

         20

         10


              1000   1200             1500           2000                                                    5000    6000
                                                            Frequency (MHz)


                                  ReadAntenna        Cable Preamp                    Limnit     Over
                      Freq       Level Factor         Loss Factor         Level       Line     Limit Remark

               """NHz dBu¥y d6/mdb — dB dBu¥/m dBbu¥/m                                           db —
          1      4377.203        47.43       30.38    6.67      41.95     44.85      74.00    —29.15      Peak
          2      4377.203        39.42       30.38    6.67      41.95     36.84      54.00    —17.16      Average
          3       §152.386       47.45       31.78    7.05      41.93     46.89      74.00    —27.11      Peak
          4       §152.386       39.45       31.78    7.05      41.93     38.89      54.00    —15.11      Average
          5       5747.456       47.80       32.65    7.74      41.96     48.96      74.00    —25.04      Peak
          6       S5747.456      39.81       32.65    7.74      41.96     40.97      54.00    —13.03      Average


 Remark:
 1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1909063
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                         Page 16 of 18


                                                                         Report No: CCISE190906306V01

7      Test Setup Photo
                                                  Radiated Emission
                                                     Below 1GHz




                                                       Above 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                      Project No.: CCISE1909063
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                     Page 17 of 18


                                                                                 Report No: CCISE190906306V01


                                                 Conducted Emission




8      EUT Constructional Details
     Reference to the test report No.: CCISE190906301




                                                     ------End of report------




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1909063
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                             Page 18 of 18



Document Created: 2019-11-01 16:09:42
Document Modified: 2019-11-01 16:09:42