CCISE190906104_BLE

FCC ID: 2AM86W-P311

Test Report

Download: PDF
FCCID_4500872

                         Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                       Report No: CCISE190906104

         1        Cover Page
                                          FCC REPORT
                                                           (BLE)

    Applicant:                          Wiko SAS

    Address of Applicant:               1, rue Capitaine Dessemond – 13007 Marseille – France.

    Equipment Under Test (EUT)

     Product Name:                      Mobile Phone

     Model No.:                         W-P311

     Trade mark:                        WIKO

    FCC ID:                             2AM86W-P311

    Applicable standards:               FCC CFR Title 47 Part 15 Subpart C Section 15.247

    Date of sample receipt:             17 Sep., 2019

    Date of Test:                       17 Sep., to 17 Oct., 2019

    Date of report issued:              17 Oct., 2019

    Test Result:                        PASS *

*    In the configuration tested, the EUT complied with the standards specified above.




Authorized Signature:




        Bruce Zhang
     Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate
to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer
should ensure that all products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than
that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted
to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested
and such sample(s) are retained for 90 days only.


                                                                            Report No: CCISE190906104


2      Version
         Version No.                                Date                        Description
                00                            17 Oct., 2019                       Original




    Tested by:                                                      Date:         17 Oct., 2019

                                      Test Engineer


    Reviewed by:                                                    Date:         17 Oct., 2019

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                       Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                       Page 2 of 34


                                                                                                                       Report No: CCISE190906104

3         Contents
                                                                                                                                                                         Page
1       COVER PAGE ....................................................................................................................................................... 1
2       VERSION ............................................................................................................................................................... 2
3       CONTENTS ........................................................................................................................................................... 3
4       TEST SUMMARY .................................................................................................................................................. 4
5       GENERAL INFORMATION .................................................................................................................................. 5
    5.1         CLIENT INFORMATION ............................................................................................................................................ 5
    5.2         GENERAL DESCRIPTION OF E.U.T........................................................................................................................ 5
    5.3         TEST ENVIRONMENT AND TEST MODE ................................................................................................................... 6
    5.4         DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 6
    5.5         MEASUREMENT UNCERTAINTY.............................................................................................................................. 6
    5.6         ADDITIONS TO, DEVIATIONS, OR EXCLUSIONS FROM THE METHOD....................................................................... 6
    5.7         LABORATORY FACILITY.......................................................................................................................................... 6
    5.8         LABORATORY LOCATION ....................................................................................................................................... 6
    5.9         TEST INSTRUMENTS LIST ....................................................................................................................................... 7
6       TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1     ANTENNA REQUIREMENT: ...................................................................................................................................... 8
    6.2     CONDUCTED EMISSION ......................................................................................................................................... 9
    6.3     CONDUCTED OUTPUT POWER ............................................................................................................................ 12
    6.4     OCCUPY BANDWIDTH .......................................................................................................................................... 14
    6.5     POWER SPECTRAL DENSITY ............................................................................................................................... 16
    6.6     BAND EDGE ......................................................................................................................................................... 18
       6.6.1 Conducted Emission Method...................................................................................................................... 18
       6.6.2 Radiated Emission Method ......................................................................................................................... 20
    6.7     SPURIOUS EMISSION ........................................................................................................................................... 25
       6.7.1 Conducted Emission Method...................................................................................................................... 25
       6.7.2 Radiated Emission Method ......................................................................................................................... 27
7       TEST SETUP PHOTO ........................................................................................................................................ 32
8       EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 34




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                             Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                      Page 3 of 34


                                                                              Report No: CCISE190906104

 4      Test Summary
                Test Items                             Section in CFR 47                       Result
          Antenna requirement                          15.203 & 15.247 (b)                      Pass
  AC Power Line Conducted Emission                            15.207                            Pass
     Conducted Peak Output Power                           15.247 (b)(3)                        Pass
        6dB Emission Bandwidth
                                                           15.247 (a)(2)                        Pass
        99% Occupied Bandwidth
         Power Spectral Density                             15.247 (e)                          Pass
                Band Edge                                   15.247 (d)                          Pass
           Spurious Emission                             15.205 & 15.209                        Pass
 Remark:
 1. Pass: The EUT complies with the essential requirements in the standard.
 2. N/A: Not Applicable.
 3. The cable insertion loss used by “RF Output Power” and other conduction measurement items is 0.5dB (provided by
      the customer).
                    ANSI C63.4-2014
 Test Method:       ANSI C63.10-2013
                    KDB 558074 D01 15.247 Meas Guidance v05r02




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 4 of 34


                                                                                 Report No: CCISE190906104

5      General Information
5.1 Client Information
       Applicant:                       Wiko SAS
       Address:                         1, rue Capitaine Dessemond – 13007 Marseille – France.
        Manufacturer/ Factory:          Shenzhen Tinno Mobile Technology Corp.
        Address:                        4/F, H-3 Building, OCT Eastern lndustrial Park. NO.1 XiangShan East
                                        Road, Nan Shan District, Shenzhen, P.R.China.

5.2 General Description of E.U.T.
       Product Name:                    Mobile Phone
       Model No.:                       W-P311
        Hardware version:               V1.0
        Software version:               W-P311-CA-V01.08-20-9.0-GBL
       Operation Frequency:             2402-2480 MHz
       Channel numbers:                 40
       Channel separation:              2 MHz
       Modulation technology:           GFSK
       Data speed :                     1Mbps
       Antenna Type:                    Internal Antenna
       Antenna gain:                    -1.0 dBi
       Power supply:                    Rechargeable Li-ion Battery DC3.85V-4000mAh
       AC adapter:                      Input: AC100-240V, 50/60Hz, 0.35A
                                        Output: DC 5.0V, 2A
       Test Sample Condition:           The test samples were provided in good working order with no visible
                                        defects.


 Operation Frequency each of channel
 Channel     Frequency    Channel              Frequency       Channel     Frequency       Channel        Frequency
    0         2402MHz        10                2422MHz           20        2442MHz           30           2462MHz
    1         2404MHz        11                2424MHz           21        2444MHz           31           2464MHz
    2         2406MHz        12                2426MHz           22        2446MHz           32           2466MHz
    3         2408MHz        13                2428MHz           23        2448MHz           33           2468MHz
    4         2410MHz        14                2430MHz           24        2450MHz           34           2470MHz
    5         2412MHz        15                2432MHz           25        2452MHz           35           2472MHz
    6         2414MHz        16                2434MHz           26        2454MHz           36           2474MHz
    7         2416MHz        17                2436MHz           27        2456MHz           37           2476MHz
    8         2418MHz        18                2438MHz           28        2458MHz           38           2478MHz
    9         2420MHz        19                2440MHz           29        2460MHz           39           2480MHz
 Note:
 In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the middle frequency,
 and the highest frequency of channel were selected to perform the test. Channel No. 0, 20 & 39 were selected as Lowest,
 Middle and Highest channel.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 5 of 34


                                                                            Report No: CCISE190906104

5.3 Test environment and test mode
 Operating Environment:
     Temperature:                    24.0 C
     Humidity:                       54 % RH
     Atmospheric Pressure:           1010 mbar
 Test mode:
     Transmitting mode               Keep the EUT in continuous transmitting with modulation
 The sample was placed 0.8m (below 1GHz)/1.5m (above 1GHz) above the ground plane of 3m chamber.
 Measurements in both horizontal and vertical polarities were performed. During the test, each emission was
 maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3 axis
 (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting cables,
 rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The
 emissions worst-case are shown in Test Results of the following pages. Duty cycle setting during the
 transmission is 100% with maximum power setting for all modulations.

5.4 Description of Support Units
       The EUT has been tested as an independent unit.

5.5 Measurement Uncertainty
                    Parameters                                           Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                   ±1.60 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                   ±3.12 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                  ±4.32 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                    ±5.38 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                   ±3.36 dB (k=2)

5.6 Additions to, deviations, or exclusions from the method
      No

5.7 Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
        FCC - Designation No.: CN1211
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by
       FCC(Federal Communications Commission). The test firm Registration No. is 727551.
        ISED – CAB identifier.: CN0021
       The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been Registered
       by Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration
       No.: 10106A-1.
        CNAS - Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of testing.
       The Registration No. is CNAS L6048.
        A2LA - Registration No.: 4346.01
       This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
       17025:2005 General requirements for the competence of testing and calibration laboratories. The test
       scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf

5.8 Laboratory Location
       Shenzhen Zhongjian Nanfang Testing Co., Ltd.
       Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
       Bao’an District, Shenzhen, Guangdong, China
       Tel: +86-755-23118282, Fax: +86-755-23116366
       Email: info@ccis-cb.com, Website: http://www.ccis-cb.com

Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 6 of 34


                                                                                  Report No: CCISE190906104

5.9 Test Instruments list
 Radiated Emission:
                                                                                           Cal. Date       Cal. Due date
    Test Equipment            Manufacturer            Model No.           Serial No.
                                                                                          (mm-dd-yy)        (mm-dd-yy)
        3m SAC                  SAEMC                 9m*6m*6m                966         07-22-2017        07-21-2020
     Loop Antenna            SCHWARZBECK             FMZB1519B              00044         03-18-2019        03-17-2020
   BiConiLog Antenna         SCHWARZBECK              VULB9163                497         03-18-2019        03-17-2020
     Horn Antenna            SCHWARZBECK             BBHA9120D                916         03-18-2019        03-17-2020
     Horn Antenna            SCHWARZBECK             BBHA9120D               1805         06-22-2017        06-21-2020
     Horn Antenna            SCHWARZBECK             BBHA 9170           BBHA9170582      11-21-2018        11-20-2019
   EMI Test Software             AUDIX                   E3                            Version: 6.110919b
     Pre-amplifier                 HP                  8447D             2944A09358       03-18-2019      03-17-2020
     Pre-amplifier                 CD                 PAP-1G18              11804         03-18-2019      03-17-2020
   Spectrum analyzer         Rohde & Schwarz           FSP30               101454         03-18-2019      03-17-2020
   Spectrum analyzer         Rohde & Schwarz           FSP40               100363         11-21-2018      11-20-2019
   EMI Test Receiver         Rohde & Schwarz           ESRP7                101070       03-18-2019         03-17-2020
        Cable                    ZDECL              Z108-NJ-NJ-81          1608458       03-18-2019         03-17-2020
        Cable                 MICRO-COAX              MFR64639             K10742-5      03-18-2019         03-17-2020
        Cable                   SUHNER              SUCOFLEX100           58193/4PE      03-18-2019         03-17-2020
    RF Switch Unit             MWRFTEST                MW200                  N/A             N/A              N/A
    Test Software              MWRFTEST               MTS8200                           Version: 2.0.0.0


 Conducted Emission:
                                                                                          Cal. Date     Cal. Due date
    Test Equipment            Manufacturer            Model No.           Serial No.
                                                                                        (mm-dd-yy)       (mm-dd-yy)
   EMI Test Receiver         Rohde & Schwarz            ESCI               101189       03-18-2019       03-17-2020
     Pulse Limiter           SCHWARZBECK             OSRAM 2306             9731        03-18-2019       03-17-2020
         LISN                    CHASE                MN2050D               1447        03-18-2019       03-17-2020
         LISN                Rohde & Schwarz          ESH3-Z5            8438621/010    07-21-2019       07-20-2020
        Cable                      HP                  10503A                N/A        03-18-2019       03-17-2020
   EMI Test Software             AUDIX                   E3                          Version: 6.110919b




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                  Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                    Page 7 of 34


                                                                              Report No: CCISE190906104

6      Test results and Measurement Data
6.1 Antenna requirement:
        Standard requirement:           FCC Part 15 C Section 15.203 /247(b)
        15.203 requirement:
        An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
        responsible party shall be used with the device. The use of a permanently attached antenna or of an
        antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
        so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
        electrical connector is prohibited.
        15.247(b) (4) requirement:
        (4) The conducted output power limit specified in paragraph (b) of this section is based on the use of
        antennas with directional gains that do not exceed 6 dBi. Except as shown in paragraph (c) of this
        section, if transmitting antennas of directional gain greater than 6 dBi are used, the conducted output
        power from the intentional radiator shall be reduced below the stated values in paragraphs (b)(1),
        (b)(2), and (b)(3) of this section, as appropriate, by the amount in dB that the directional gain of the
        antenna exceeds 6 dBi.
       E.U.T Antenna:
       The BLE antenna is an Internal antenna which cannot replace by end-user, the best-case gain of the
       antenna is -1.0 dBi.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 8 of 34


                                                                              Report No: CCISE190906104

6.2 Conducted Emission
       Test Requirement:                FCC Part 15 C Section 15.207
       Test Frequency Range:            150 kHz to 30 MHz
       Class / Severity:                Class B                  Class B
       Receiver setup:                  RBW=9kHz, VBW=30kHz
       Limit:                                                                         Limit (dBuV)
                                         Frequency range (MHz)
                                                                          Quasi-peak               Average
                                                0.15-0.5                    66 to 56*              56 to 46*
                                                  0.5-5                        56                     46
                                                  5-30                         60                     50
                                        * Decreases with the logarithm of the frequency.
       Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                            line impedance stabilization network (L.I.S.N.), which provides a
                                            50ohm/50uH coupling impedance for the measuring equipment.
                                        2. The peripheral devices are also connected to the main power
                                            through a LISN that provides a 50ohm/50uH coupling impedance
                                            with 50ohm termination. (Please refer to the block diagram of the test
                                            setup and photographs).
                                        3. Both sides of A.C. line are checked for maximum conducted
                                            interference. In order to find the maximum emission, the relative
                                            positions of equipment and all of the interface cables must be
                                            changed according to ANSI C63.4-2014 on conducted measurement.
       Test setup:




       Test Instruments:                Refer to section 5.9 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 9 of 34


CCIS                                                                                                           Report No: CCISE190906104

Measurement Data:

Product name:                Mobile Phone                                            Product model:                  W—P311

Test by:                     YT                                                      Test mode:                      BLE Tx mode

Test frequency:              150 kHz ~ 30 MHz                                        Phase:                          Line
Test voltage:                AC 120 V/60 Hz                                          Environment:                    Temp: 22.5°C              Huni: 55%


    20 Level (dBuV)



    70

    so\                                                                                                                      FCC PART 15.247 ap
         ‘_\“‘-—x___                                                                                                         FCC PART 15.247 AV
    50                 f=—

    40                                s         4
                                      4                      6                                                                    12
    30                            M        TY                                   4        9

    20                                                   1                      ‘.        o
                 fMbntely)                               M                                                                             m
                                                                                                  k)

    4pf=J—                                           N           Th     ,—a                              ¥heotiuhysparritionsud            .
                                                                                                                                               Mw



         A5 .2                        6                  1                           2                     5                10                 20      30
Eim ra k                                                                      Frequency (MHz)



                           Read   LISN               Cable                               Limit          Over
                  Freq    Level Factor                 Loss                   Level        Line        Limit Remark

                   NHz     dBu¥y                dB                    dB dBu¥ dBu¥ _                           dB
    1            0.471    14.58           —0.38      10.75                    24.95      46.49    —21.54 Average
    2            0.513    24.33           —O.39      10.76                    34.70°     56.00    —21.30°gP
    >            0.59§5   15.94           —0.38      10.77                    26.33      46.00    —19.67 Average
    4            0. T39   2§8.02          (—0.38     10.79.                   38.43      56.00    —17.57 9P
    §            1.010    11.21           —0.38      10.87                    21.70      46.00    —24.30 Average
    6            1.054    22.71           —O0.38     10.88                    33.31.     56.00    —22.19 QP
    T            1.636    19.08           —0.40      10.93                    29.61      56.00    —26.39 QP
    &            1. 654    9.09           —0.40      10.94                    19.63      46.00    —26.37 Average
    9            2.540    17.75           —0.43      10.94.                   28.26      56.00    —27.14 9P
   10            2. 636    8.23           —0.43      10.93                    18.73      46.00    —27.27 Average
   11            3. 681    6.23           —0.46      10.90                    16.67      46.00    —29.33 Average
   12           12.124    22.85           —D.64.     10.92                    33.13      60.00    —26.87 oP



Notes:
1. An initial pre—scan was performed on the line and neutral lines with peak detector.
2. Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                 Project No.: CCISE1909061
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                      Page 10 of 34


c c I s                                                                                              Report No: CCISE190906104


Product name:                  Mobile Phone                                    Product model:              W—P311

Test by:                       YT                                              Test mode:                  BLE Tx mode

Test frequency:                150 kHz ~ 30 MHz                                Phase:                      Neutral

Test voltage:                  AC 120 V/60 Hz                                  Environment:                Temp: 22.5°C            Huni: 55%


      80 Level (dBuV)


      70

     so\                                                                                                      FCC PART 15.247 oPp
           s_.1.
      50        \\\                                                                                           FCC PART 15.247 AV


     40                      15              #g
                                                          8                       10
      30                                R    ‘        ]

                                    I         1                      g             2
      20             a
           y m,"‘fM"W.\,\Jfif                      M                                                                  °.
      40(***                                                  (          "Yalhs            ents/                          *          4


           165 2                    5                 1                    2                     5           10               20        30
Frmmes a~                                                          Frequency (MHz)


                             Read    LISN             Cable                            Limit     Over
                    Freq    Level Factor                Loss          Level              Line   Limit Remark

            ______MHz dBuvy — dB                                  dB dBu¥ dBu¥ —                         dB
     1             0.406    28.50           —0.64         10.72       38.58            57.73    —19.15   QP
     2             0.521    29.46           —O.65         10.76       39.57            56.00    —16.43   QP
     3             0.535§   16.83           —0.65         10.76       26.94            46.00    —19.06   Average
     4             0. 614   15.69           —0.64         10.77       25.82            46.00    —20.18   Average
     5             0.675    26.66           —0.64         10.77       36.79            56.00    —19.21   QP
     6             0.739    26.03           —0.64         10.79       36.18            56.00    —19.82   QP
     7             1.016    12.43           —0.63         10.87       22.67            46.00    —23.33   Average
     &             1.060    22.58           —O.63         10.88       32.83            56.00    —23.17   QP
      9            1.680     8.46           —D.66         10.94       198.74           46.00 —26.26 Average
     10            2. 500   21.24           —0.67         10.94       31.51            56.00 —24.49 QP
     11            2. 636    9.25           —O.67         10.93       19.51            46.00 —26.49 &verage
     12            2. 900    9.08           —0.67         10.92       19.33            46.00 —26.607 Average


Notes:
1. An initial pre—scan was performed on the line and neutral lines with peak detector.
2.   Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                      Project No.: CCISE1909061
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                          Page 11 of 34


                                                                               Report No: CCISE190906104

6.3 Conducted Output Power
       Test Requirement:                FCC Part 15 C Section 15.247 (b)(3)
       Limit:                           30dBm
       Test setup:




       Test Instruments:                Refer to section 5.9 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed


Measurement Data:
                               Maximum Conducted Output Power
         Test CH                                                              Limit(dBm)              Result
                                          (dBm)
          Lowest                                 -2.55
           Middle                                -2.27                          30.00                  Pass
          Highest                                -3.96




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 12 of 34


                                                                                                                                     Report No: CCISE190906104

Test plot as follows:
                                                * RBW   1 MHz    Marker 1 [T1 ]                                                              * RBW   1 MHz   Marker 1 [T1 ]
                                                * VBW   3 MHz               -2.55 dBm                                                        * VBW   3 MHz              -2.27 dBm
        Ref    16.5 dBm         * Att   20 dB       SWT 2.5 ms        2.402100000 GHz                Ref    16.5 dBm         * Att   20 dB     SWT 2.5 ms         2.442160000 GHz

              Offset   6.5 dB                                                                              Offset   6.5 dB

        10                                                                                           10
                                                                                        A                                                                                           A


 1 PK   0                                       1                                             1 PK   0                                        1
 MAXH                                                                                         MAXH
                                                                                        LVL                                                                                         LVL

        -10                                                                                          -10



        -20                                                                                          -20



        -30                                                                                          -30



        -40                                                                             3DB          -40                                                                            3DB




        -50                                                                                          -50



        -60                                                                                          -60



        -70                                                                                          -70



        -80                                                                                          -80

        Center 2.402 GHz                    500 kHz/                       Span 5 MHz                Center 2.442 GHz                    500 kHz/                      Span 5 MHz




 Date: 12.OCT.2019         10:48:47                                                           Date: 12.OCT.2019         10:48:59


                                        Lowest channel                                                                               Middle channel


                                                * RBW   1 MHz    Marker 1 [T1 ]
                                                * VBW   3 MHz               -3.96 dBm
        Ref    16.5 dBm         * Att   20 dB       SWT 2.5 ms        2.479740000 GHz

              Offset   6.5 dB

        10
                                                                                        A


 1 PK   0                                   1
 MAXH
                                                                                        LVL

        -10



        -20



        -30



        -40                                                                             3DB




        -50



        -60



        -70



        -80

        Center 2.48 GHz                     500 kHz/                       Span 5 MHz




 Date: 12.OCT.2019         10:49:30


                                        Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                                            Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                                     Page 13 of 34


                                                                               Report No: CCISE190906104

6.4 Occupy Bandwidth
       Test Requirement:                FCC Part 15 C Section 15.247 (a)(2)
       Limit:                           >500kHz
       Test setup:




       Test Instruments:                Refer to section 5.9 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed


Measurement Data:
         Test CH               6dB Emission Bandwidth (MHz)                Limit(kHz)             Result
          Lowest                              0.738
          Middle                              0.726                          >500                 Pass
         Highest                              0.732
         Test CH                99% Occupy Bandwidth (MHz)                 Limit(kHz)             Result
          Lowest                              1.044
          Middle                              1.038                           N/A                  N/A
         Highest                              1.044




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                           Page 14 of 34


CCIS                                                                                          Report No: CCISE190906104

Test plot as follows:
                                6dB EBW                                                         99% OBW
  ® see   ces wee




  oute: az cer.zon restpcon                                      dare: a2.00t.2000 resesize

                              Lowest channel                                                  Lowest channel




  oute: as cer.zors resiezs                                      oare: as.cor.co0 esns

                              Middle channel                                                  Middle channel




  oete: az ccr.zos reserces                                      dare: as.00r.2000 resenins

                              Highest channel                                                 Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                            Project No.: CCISE1909061
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                           Page 15 of 34


                                                                              Report No: CCISE190906104

6.5 Power Spectral Density
       Test Requirement:                FCC Part 15 C Section 15.247 (e)
       Limit:                           8 dBm
       Test setup:




       Test Instruments:                Refer to section 5.9 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed


Measurement Data:
           Test CH                 Power Spectral Density (dBm)            Limit(dBm)             Result
           Lowest                                -3.80
            Middle                               -3.51                        8.00                 Pass
           Highest                               -5.12




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                           Page 16 of 34


CCIS                                                                                       Report No: CCISE190906104

Test plots as follow:

 ® ser   ces wan




 oates 1z.ocr.z0r8 resae:as                                     oares 12.ccr .208 rrreus
                              Lowest channel                                               Middle channel




 oates 1z.ocrz0r8 rsa7es

                              Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1909061
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                       Page 17 of 34


                                                                                Report No: CCISE190906104

6.6 Band Edge
6.6.1 Conducted Emission Method
       Test Requirement:                FCC Part 15 C Section 15.247 (d)
       Limit:                           In any 100 kHz bandwidth outside the frequency band in which the spread
                                        spectrum intentional radiator is operating, the radio frequency power that
                                        is produced by the intentional radiator shall be at least 20 dB below that in
                                        the 100 kHz bandwidth within the band that contains the highest level of
                                        the desired power, based on either an RF conducted or a radiated
                                        measurement.
       Test setup:




       Test Instruments:                Refer to section 5.9 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 18 of 34


CCIS                                                                                            Report No: CCISE190906104

Test plots as follow:
                    @                                             ~rew 10e x ur   marken i tri i
                                                                  «vam 200 x                 —si201 dam
                         nee   16.3 cam        «are   20 ae        sur 2ls n           2.2se2e0000. onz




                         mso
                         stare 2030 ons                       1e miny                    stop 2.¢032 ons




                    Date: 12.00T.2019      14:45:33

                                                         Lowest channel



                                                                  «haw 100 kn     marker i cri d
                                                                  «vaw 200 kn                ~52.50. dam
                                               «are   20 ae        sur 225 me          2. 486402000 onz




                          ~
                         stare 2.278 ons                  2.2 mie,                         stop 2.5 on




                    Date: 12.00T.2019      14:44:54

                                                         Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                               Project No.: CCISE1909061
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                              Page 19 of 34


                                                                              Report No: CCISE190906104

6.6.2     Radiated Emission Method
        Test Requirement:               FCC Part 15 C Section 15.205 and 15.209
        Test Frequency Range:           2.3GHz to 2.5GHz
        Test Distance:                  3m
        Receiver setup:                  Frequency          Detector        RBW           VBW           Remark
                                                             Peak           1MHz          3MHz        Peak Value
                                        Above 1GHz
                                                             RMS            1MHz          3MHz       Average Value
        Limit:                                Frequency             Limit (dBuV/m @3m)              Remark
                                                                            54.00                Average Value
                                             Above 1GHz
                                                                            74.00                 Peak Value
        Test Procedure:                 1. The EUT was placed on the top of a rotating table 1.5 meters above
                                            the ground at a 3 meter camber. The table was rotated 360 degrees
                                            to determine the position of the highest radiation.
                                        2. The EUT was set 3 meters away from the interference-receiving
                                            antenna, which was mounted on the top of a variable-height antenna
                                            tower.
                                        3. The antenna height is varied from one meter to four meters above
                                            the ground to determine the maximum value of the field strength.
                                            Both horizontal and vertical polarizations of the antenna are set to
                                            make the measurement.
                                        4. For each suspected emission, the EUT was arranged to its worst
                                            case and then the antenna was tuned to heights from 1 meter to 4
                                            meters and the rota table was turned from 0 degrees to 360 degrees
                                            to find the maximum reading.
                                        5. The test-receiver system was set to Peak Detect Function and
                                            Specified Bandwidth with Maximum Hold Mode.
                                        6. If the emission level of the EUT in peak mode was 10 dB lower than
                                            the limit specified, then testing could be stopped and the peak values
                                            of the EUT would be reported. Otherwise the emissions that did not
                                            have 10 dB margin would be re-tested one by one using peak, quasi-
                                            peak or average method as specified and then reported in a data
                                            sheet.
        Test setup:




        Test Instruments:               Refer to section 5.9 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 20 of 34


CCIS                                                                                   Report No: CCISE190906104


 Product Name:              Mobile Phone                               Product model:           W—P311

 Test By:                   YT                                         Test mode:               BLE Tx mode

 Test Channel:              Lowest channel                             Polarization:            Vertical

 Test Voltage:              AC 120/60Hz                                Environment:             Temp: 24°C      Huni: 57%


      110 Level (dBuVim)

      100



       §8                                                                                             FCC PART 15 (Ffi(\


       60                                                                                                   i
            NPareainsen                                                   eotvion                                    AV)


       40


       20



          02310    2320                                2350                                                            2404
                                                           Frequency (MHz)




                            Readintenna         Cable Preamp                   Linmit      Over
                  Freq     Level Factor          Loss Factor         Level      Line      Linit Remark

            “““““MHz       dBu¥ _dB/nm               dB _        dB dBuV/m dBuV¥/m             dB               O
      1      2390.000      24.46     27.07       414. 69      0.00   57.90      74.00 —16.10 Peak
      2      2390.000      13.12     27.07       1. 69        0.00   46.56      54.00 —T.44 Average



 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE 1909061
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                           Page 21 of 34


CCIS                                                                                   Report No: CCISE190906104


Product Name:              Mobile Phone                       Product model:                 W—P311

Test By:                   YT                                 Test mode:                     BLE Tx mode

Test Channel:              Lowest channel                     Polarization:                  Horizontal

Test Voltage:              AC 120/60H2z                       Environment:                   Temp: 24°C          Huni: 57%


    110 Level (dBuVim)


    100




        80                                                                                                FCC PART 15 (Ffl(\


        60                                                                                                 a+
             fomeyner sxtrvneriths     s hests                           ef            a    VM                         AV)


        40



        20




         02310      2320                               2350                                                             2404
                                                        Frequency (MHz)




                            Read&ntenna      Cable Preamp                     Limit         Over
                   Freq    Level Factor        Loss Factor        Level         Line       Linmit Remark

             ______MHz dBuv¥ dB/m                 dB _      dB dBu¥/m dBu¥/m ——               dB          ~

    1         2390.000     23.51     27.08     4.69      0. 00    56.96       74.00 —17.04 Peak
    2         2390.000     13.43     27.08     4.69      0.00     46.88       54.00 —T.12 Average




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1909061
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                         Page 22 of 34


c c I s                                                                                Report No: CCISE190906104


 Product Name:               Mobile Phone                              Product model:            W—P311

Test By:                     YT                                        Test mode:                BLE Tx mode

Test Channel:                Highest channel                           Polarization:             Vertical

Test Voltage:                AC 120/60Hz                               Environment:              Temp: 24°C    Huni: 57%


      110 Level (dBuVim}

      100



       80
                                                                                                       FCC PART 15 (PK)


       offel —|—Bm frm eneonmemnts
       40



       20



          0
              2478                                                                                                   2500
                                                          Frequency (MHz)




                             Readintenna       Cable Preamp                  Limit      Over
                     Freq   Level Factor         Loss Factor       Level       Line    Limit Remark

                      MHz    dBu¥      dB/n        dB        dB dBu¥/m dBu¥/m               dB

      1        2483.500     24.92    27.36      4.81      0.00     58.79     74.00 —15.21 Feak
      2        2483.500     13.39    27.36      4.81      0.00     47.26     54.00 —6.74 Average




 Remark:
 1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1909061
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                       Page 23 of 34


c c I s                                                                              Report No: CCISE190906104



Product Name:             Mobile Phone                        Product model:              W—P311

Test By:                  YT                                  Test mode:                  BLE Tx mode

Test Channel:             Highest channel                     Polarization:               Horizontal

Test Voltage:             AC 120/60Hz                         Environment:                Temp: 24°C           Huni: 57%


    110 Level (dBuVim)


    100



     80
                                                                                                       FCC PART 15 (PK)


     60 /               \,\,1[prompr[is0*~TCC
                                                                                                           PART15(ah


     40



     20



          2478                                                                                                       2500
                                                         Frequency (MHz)




                           Readintenna         Cable Preamp                    Limit      Over
                 Freq     Level Factor           Loss Factor        Level       Line     Linmit Remark

                  MHz          dBu¥     dB/n        dB        dE dBu¥/m dBu¥/nm               dB

     1      2483.500      25.70       27.35     4.81         0.00   59.56      74.00 —14.44 Peak
     2      2483.500      13.41       27.35     4.81         0.00   47.27      54.00 —6.73 Average




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                       Project No.: CCISE1909061
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                        Page 24 of 34


                                                                                Report No: CCISE190906104

6.7     Spurious Emission
6.7.1     Conducted Emission Method
        Test Requirement:               FCC Part 15 C Section 15.247 (d)
        Limit:                          In any 100 kHz bandwidth outside the frequency band in which the spread
                                        spectrum intentional radiator is operating, the radio frequency power that
                                        is produced by the intentional radiator shall be at least 20 dB below that in
                                        the 100 kHz bandwidth within the band that contains the highest level of
                                        the desired power, based on either an RF conducted or a radiated
                                        measurement.
        Test setup:




        Test Instruments:               Refer to section 5.9 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 25 of 34


                                                                                                                                        Report No: CCISE190906104

Test plot as follows:
                                         Lowest channel                                                                                 Middle channel
                                                 * RBW   100 kHz   Marker 1 [T1 ]                                                               * RBW   100 kHz   Marker 1 [T1 ]
                                                 * VBW   300 kHz             -43.92 dBm                                                         * VBW   300 kHz             -44.89 dBm
        Ref    16.5 dBm          * Att   20 dB     SWT 2.5 s           13.663620000 GHz                Ref    16.5 dBm          * Att   20 dB     SWT 2.5 s           13.613680000 GHz

              Offset    6.5 dB                                                                               Offset    6.5 dB

        10                                                                                             10
                                                                                          A                                                                                              A


 1 PK   0                                                                                       1 PK   0
 MAXH                                                                                           MAXH
                 D1 -4.92 dBm                                                             LVL                   D1 -4.79 dBm                                                             LVL

        -10                                                                                            -10



        -20                                                                                            -20

                       D2 -24.92 dBm                                                                                  D2 -24.79 dBm

        -30                                                                                            -30



        -40                                                                               3DB          -40                                                                               3DB
                                                   1                                                                                              1


        -50                                                                                            -50



        -60                                                                                            -60



        -70                                                                                            -70



        -80                                                                                            -80

        Start 30 MHz                        2.497 GHz/                      Stop 25 GHz                Start 30 MHz                        2.497 GHz/                      Stop 25 GHz




 Date: 12.OCT.2019           14:42:03                                                           Date: 12.OCT.2019           14:42:43


                                         30MHz~25GHz                                                                                    30MHz~25GHz


                                         Highest channel
                                                 * RBW   100 kHz   Marker 1 [T1 ]
                                                 * VBW   300 kHz             -44.22 dBm
        Ref    16.5 dBm          * Att   20 dB     SWT 2.5 s           14.962060000 GHz

              Offset    6.5 dB

        10
                                                                                          A


 1 PK   0
 MAXH
                 D1 -5.76 dBm                                                             LVL

        -10



        -20

                       D2 -25.76 dBm

        -30



        -40                                                                               3DB
                                                         1



        -50



        -60



        -70



        -80

        Start 30 MHz                        2.497 GHz/                      Stop 25 GHz




 Date: 12.OCT.2019           14:44:05


                                         30MHz~25GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                                               Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                                          Page 26 of 34


                                                                                Report No: CCISE190906104

 6.7.2 Radiated Emission Method
       Test Requirement:                FCC Part 15 C Section 15.205 and 15.209
       Test Frequency Range:            9kHz to 25GHz
       Test Distance:                   3m
       Receiver setup:                     Frequency       Detector         RBW        VBW             Remark
                                          30MHz-1GHz      Quasi-peak      120KHz     300KHz       Quasi-peak Value
                                                            Peak           1MHz        3MHz           Peak Value
                                          Above 1GHz
                                                            RMS            1MHz        3MHz         Average Value
       Limit:                                   Frequency           Limit (dBuV/m @3m)              Remark
                                              30MHz-88MHz                    40.0               Quasi-peak Value
                                             88MHz-216MHz                    43.5               Quasi-peak Value
                                            216MHz-960MHz                    46.0               Quasi-peak Value
                                              960MHz-1GHz                    54.0               Quasi-peak Value
                                                                             54.0                Average Value
                                               Above 1GHz
                                                                             74.0                 Peak Value
       Test Procedure:                  1.    The EUT was placed on the top of a rotating table 0.8m(below
                                              1GHz)/1.5m(above 1GHz) above the ground at a 3 meter camber.
                                              The table was rotated 360 degrees to determine the position of the
                                              highest radiation.
                                        2.    The EUT was set 3 meters away from the interference-receiving
                                              antenna, which was mounted on the top of a variable-height antenna
                                              tower.
                                        3.    The antenna height is varied from one meter to four meters above
                                              the ground to determine the maximum value of the field strength.
                                              Both horizontal and vertical polarizations of the antenna are set to
                                              make the measurement.
                                        4.    For each suspected emission, the EUT was arranged to its worst
                                              case and then the antenna was tuned to heights from 1 meter to 4
                                              meters and the rota table was turned from 0 degrees to 360 degrees
                                              to find the maximum reading.
                                        5.    The test-receiver system was set to Peak Detect Function and
                                              Specified Bandwidth with Maximum Hold Mode.
                                        6.    If the emission level of the EUT in peak mode was 10 dB lower than
                                              the limit specified, then testing could be stopped and the peak values
                                              of the EUT would be reported. Otherwise the emissions that did not
                                              have 10 dB margin would be re-tested one by one using peak, quasi-
                                              peak or average method as specified and then reported in a data
                                              sheet.
       Test setup:                      Below 1GHz




                                        Above 1GHz



Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 27 of 34


                                                                              Report No: CCISE190906104




       Test Instruments:                Refer to section 5.9 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed
       Remark:                          1. Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and found
                                           the Y-axis is the worst case.
                                        2. 9 kHz to 30MHz is too low, so only shows the data of above 30MHz in
                                           this report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 28 of 34


CCIS                                                                                 Report No: CCISE190906104

Measurement Data (worst case):
Below 1GHz:

 Product Name:               Mobile Phone                           Product model:             W—P311

 Test By:                    YT                                     Test mode:                 BLE Tx mode

 Test Frequency:             30 MHz ~ 1 GHz                         Polarization:              Vertical

 Test Voltage:               AC 120/60Hz                            Environment:               Temp: 24°C         Huni: 57%


     so Level (dBuV/im}


     70


     60
                                                                                                         FCC PART 15.247
     50


     40

     30


     20

     10


      030               50                    100                200                               500                1000
                                                       Frequency (MHz)




                           Readintenna        Cable Preamp                 Limit      Over
                 Freq     Level Factor          Loss Factor      Level       Line    Linit Remark

            ______NHz dBu¥ dB/m — dB — dB dBu¥/m dBu¥/m dB
     1        30.853      53.99     10.71      0.7T8   29.97     35.51     40.00     —4.49   QP
     2        40.136      44.11     12.40      1.32>   29.90     27.83     40.00    —12.17   QP
     3        5§3.505     44.69     11.74      1.32    29.81     27.94     40.00    —12.06   qP
     4        5§9.649     42.92     11.41      1.38    29.77     25.94     40.00    —14.06   oP
     5       100. 229     40.09     12.50      1.94    29.53     25.00     43.50    —18.50   QP
     6       132.685      48.50      9.99      2.32    29.31     31.50     43.50    —12.00   qPr




 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1809061
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                        Page 29 of 34


CCIS                                                                                   Report No: CCISE190906104


 Product Name:                Mobile Phone                            Product model:            W—P311

 Test By:                     YT                                      Test mode:                BLE Tx mode

 Test Frequency:              30 MHz ~ 1 GHz                          Polarization:             Horizontal

 Test Voltage:                AC 120/60Hz                             Environment:              Temp: 24°C        Huni: 57%


      so Level (dBuVim)


      T0

      6O
                                                                                                          FCC PART 15.247
      50

      40

      30

      20

      10


       030              50                     100                   200                            500                1000
                                                          Frequency (MHz)




                           Read&ntenna         Cable Preamp                 Limit      Over
                 Freq     Level Factor          Loss Factor       Level       Line    Linmit Remark

           """NHz            dBu¥     dB/n           dB      dB dBuV/m dBu¥/m —           dB
      1       54.643         37.38   11.62      1.34      29.80   20.54     40.00 —19.46       QP
      2      107.134         34.95   11.90      2.02      29.48   19.39     43.50 —24.11       QP
      2      126.772         38.86   10.40      2.25      29.35   22.16     43.50 —21.34       QP
      4      159. 784        40.05    9. 27     2eb0:     20.13   22.18     43.500 —<20.72     OP
      5      202.100         40.00   10.68      2.81      28.82   M.T3      43.50—18.71        gP
      6      361.714         31.68   14.78      3.10      28.61   20.95     46.00 —25.05       QP




 Remark:
 1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1909061
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                         Page 30 of 34


                                                                                    Report No: CCISE190906104

Above 1GHz
                                             Test channel: Lowest channel
                                                 Detector: Peak Value
                  Read       Antenna        Cable       Preamp                                     Over
 Frequency                                                            Level       Limit Line
                  Level       Factor        Loss         Factor                                    Limit    Polarization
   (MHz)                                                            (dBuV/m)      (dBuV/m)
                 (dBuV)       (dB/m)         (dB)         (dB)                                     (dB)
  4804.00        49.52         30.85        6.80       41.81       45.36            74.00         -28.64      Vertical
  4804.00        50.74         30.85        6.80       41.81       46.58            74.00         -27.42     Horizontal
                                                Detector: Average Value
                  Read       Antenna        Cable     Preamp                                       Over
 Frequency                                                         Level          Limit Line
                  Level       Factor        Loss       Factor                                      Limit    Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)
                 (dBuV)       (dB/m)         (dB)       (dB)                                       (dB)
  4804.00         40.36        30.85        6.80       41.81       36.20            54.00         -17.80      Vertical
  4804.00         41.78        30.85        6.80       41.81       37.62            54.00         -16.38     Horizontal



                                              Test channel: Middle channel
                                                  Detector: Peak Value
                  Read       Antenna        Cable     Preamp                                       Over
 Frequency                                                          Level         Limit Line
                  Level       Factor        Loss       Factor                                      Limit    Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)
                 (dBuV)       (dB/m)         (dB)       (dB)                                       (dB)
  4884.00         50.53        31.20        6.86       41.84       46.75            74.00         -27.25      Vertical
  4884.00         51.39        31.20        6.86       41.84       47.61            74.00         -26.39     Horizontal
                                                Detector: Average Value
                  Read       Antenna        Cable     Preamp                                       Over
 Frequency                                                          Level         Limit Line
                  Level       Factor        Loss       Factor                                      Limit    Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)
                 (dBuV)       (dB/m)         (dB)       (dB)                                       (dB)
  4884.00         40.52        31.20        6.86       41.84       36.74            54.00         -17.26      Vertical
  4884.00         41.72        31.20        6.86       41.84       37.94            54.00         -16.06     Horizontal



                                              Test channel: Highest channel
                                                  Detector: Peak Value
                  Read       Antenna        Cable      Preamp                                      Over
 Frequency                                                          Level         Limit Line
                  Level       Factor        Loss        Factor                                     Limit    Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)
                 (dBuV)       (dB/m)         (dB)        (dB)                                      (dB)
  4960.00         50.26        31.63        6.91        41.87       46.93           74.00         -27.07      Vertical
  4960.00         51.75        31.63        6.91        41.87       48.42           74.00         -25.58     Horizontal
                                                Detector: Average Value
                  Read       Antenna        Cable      Preamp                                      Over
 Frequency                                                          Level         Limit Line
                  Level       Factor        Loss        Factor                                     Limit    Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)
                 (dBuV)       (dB/m)         (dB)        (dB)                                      (dB)
  4960.00         41.15        31.63        6.91        41.87       37.82           54.00         -16.18      Vertical
  4960.00         42.39        31.63        6.91        41.87       39.06           54.00         -14.94     Horizontal
 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
 2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1909061
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                    Page 31 of 34



Document Created: 2019-10-25 17:48:46
Document Modified: 2019-10-25 17:48:46

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC