I19Z61642-SEM03_SAR_Rev2_Part5

FCC ID: 2AM86U307AS

RF Exposure Info

Download: PDF
FCCID_4503672

€7T7L                                                                                       CAICT


(
                                                                               ro+ se k sea c nz ud ks   Nulrvrviw




  DASY5 Validation Report for Head TSL
                                                                                             Date: 15.07.2019

  Test Laboratory: SPEAG, Zurich, Switzerland

  DUT: Dipole 835 MHz; Type: D835V2; Serial: D835V2 — SN:4d069

  Communication System: UID 0 — CW; Frequency: 835 MHz
  Medium parameters used: f = 835 MHz; 0 = 0.91 S/m; &, = 42; p = 1000 kg/m3
  Phantom section: Flat Section
  Measurement Standard: DASYS (IEEE/IEC/ANSI C63.19—2011)

  DASY52 Configuration:

     e   Probe: EX3DV4 — SN7349; ConvF(9.89, 9.89, 9.89) @ 835 MHz; Calibrated: 29.05.2019

     e    Sensor—Surface: 1.4mm (Mechanical Surface Detection)

     e    Electronics: DAE4 Sn601; Calibrated: 30.04.2019

     *    Phantom: Flat Phantom 4.9 (front); Type: QD OOL P49 AA; Serial: 1001

     e    DASY32 52.10.2(1504); SEMCAD X 14.6.12(7470)


  Dipole Calibration for Head Tissue/Pin=250 mW, d=15mm/Zoom Scan (7x7x7)/Cube 0:
  Measurement grid: dx=5mm, dy=5mm, dz=5mm
  Reference Value = 63.48 V/m; Power Drift = 0.01 dB
  Peak SAR (extrapolated) = 3.58 W/kg
  SAR(1 g) = 2.44 W/kg; SAR(10 g) = 1.58 W/kg
  Maximum value of SAR (measured) = 3.22 W/kg




                     0 dB = 3.22 W/kg = 5.08 dBW/kg




  Certificate No: D835V2—4d069_Jul19              Page 5 of 8




                                                                                       t   negn n >   en — >


m_>
 TTL                                                                                         CAICT
                                                                                  ow se kok se in k w e k2       ui vrvi w




 Impedance Measurement Plot for Head TSL




      File View Channel Sweep Calibration Trace Scale Marker System Window Help

                                                                        835.000000 MHz          50.811 O
                                                                              80.654 pF        —2.3632 0
                                                                                              24.778 mU
                                                                                                —69.710 °




                    Ch1Aug= 20
           Ch1: Start 635.000 MHa   ——                                                        Stop 1.03500 GHz

                                                                        835.000000




          00       Ch 1     z
          Chi: Start €35.000 MHz                                                              Stop 1.03500 GHz

                                         C T—Por                                                   E8t




 Certificate No: D835V2—4d069_Jul19                Page 6 of 8


DASY5 Validation Report for Body TSL
                                                                                    Date: 18.07.2019

Test Laboratory: SPEAG, Zurich, Switzerland

DUT: Dipole 835 MHz; Type: D835V2; Serial: D835V2 — SN:4d069

Communication System: UID 0 — CW; Frequency: 835 MHz
Medium parameters used: f = 835 MHz; 0 = 0.99 S/m; &, = 54.9; p = 1000 kg/m3
Phantom section: Flat Section
Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19—2011)

DASY52 Configuration:

        Probe: EX3DV4 — SN7349; ConvF(10.16, 10.16, 10.16) @ 835 MHz; Calibrated: 29.05.2019

        Sensor—Surface: 1.4mm (Mechanical Surface Detection)

        Electronics: DAE4 Sn601; Calibrated: 30.04.2019

        Phantom: Flat Phantom 4.9 (Back); Type: QD OOR P49 AA; Serial: 1005

        DASY52 52.10.2(1504); SEMCAD X 14.6.12(7470)


Dipole Calibration for Body Tissue/Pin=250 mW, d=15mm/Zoom Scan (7x7x7)/Cube 0:
Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 57.81 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 3.65 W/kg
SAR(I g) = 2.46 W/kg; SAR(10 g) = 1.6 W/kg
Maximum value of SAR (measured) = 3.28 W/kg




        —2.15


        ~4.30


        —6.44


        —8.59


        —10.74
                   0 dB = 3.28 W/kg = 5.16 dBW/kg




Certificate No: D835V2—4d069_Jul19             Page 7 of 8


Impedance Measurement Plot for Body TSL




     File View    Channel    Sweep Calibration Trace   Scale Marker System Window   Help

                                                                            _   §35.000000 MHz     47.073 O
                                                                                                  —3.9356 0
                                                                                                 50.481 mU
                                                                                                   ~124.31°




                   Ch1Aug= 20
          Ch1: Start £35.000 MHz   ——                                                            Stop 1.03500 GHz

                                                                                835.000000       —2$.937 dB




         .00

         00
         00

         .00
         00
         Chi: Start                                                                              Stop 1.03500 GHz

       Status     JEA T     OO CpC—+FPor                                                              LCL




Certificate No: D835V2—4d069_Jul19                        Page 8 of 8


§7TTL                                                                                                                                CAICT

an en n n n n e e e                            e es




         s      M                                                         w\ 1Ufe,
    Calibration Laboratory of                                          $                                       g Schweizerischer Kalibrierdienst
    Schmid & Partner                                                 ;ila\ei\-éufié                             c Service suisse d‘étalonnage
      Engineering AG                                                  7z /R 7                                          Servizio svizzero di taratura
    Zeughausstrasse 43, 8004 Zurich, Switzerland                      4/ /m                                    S       swiss Calibration Service


    Accredited by the Swiss Accreditation Service (SAS)                                                         Accreditation No.: SCS 0108
    The Swiss Accreditation Service is one of the signatories to the EA
    Multilateral Agreement for the recognition of calibration certificates

    Client                                                                                          Certificate No: D1750V2—1003_Jul19

    CALIBRATION CERTIFICATE
     Object                                D1750V2 — SN:1003


     Calibration procedure(s)              QA CAL—O5.v11
                                           Calibration Procedure for SAR Validation Sources between 0.7—3 GHz



     Calibration date:                     July 16, 2019


     This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
     The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


     All calibrations have been conducted in the closed laboratory facility: environmenttemperature (22 + 3)°C and humidity < 70%.


     Calibration Equipment used (M&TE critical for calibration)


     Primary Standards                      ID #                      Cal Date (Certificate No.)                            Scheduled Calibration
     Power meter NRP                        SN: 104778                03—Apr—19 (No. 217—02892/02893)                       Apr—20
     Power sensor NRP—Z291                  SN: 103244                03—Apr—19 (No. 217—02892)                             Apr—20
     Power sensor NRP—Z91                   SN: 103245                03—Apr—19 (No. 217—02893)                             Apr—20
     Reference 20 dB Attenuator             SN: 5058 (20k)            04—Apr—19 (No. 217—02894)                             Apr—20
     Type—N mismatch combination            SN: 5047.2 / 06327        04—Apr—19 (No. 217—02895)                             Apr—20
     Reference Probe EX3DV4                 SN: 7349                  29—May—19 (No. EX3—7349_May19)                        May—20
     DAE4                                   SN: 601                   30—Apr—19 (No. DAE4—601_Apr19)                        Apr—20

     Secondary Standards                    ID #                      Check Date (in house)                                 Scheduled Check
     Power meter E44198                     SN: GB30512475            30—Oct—14 (in house check Feb—19)                     In house check: Oct—20
     Power sensor HP 8481A                  SN: US37292783            07—Oct—15 (in house check Oct—18)                     In house check: Oct—20
     Power sensor HP 8481A                  SN: MY41092317            07—Oct—15 (in house check Oct—18)                     In house check: Oct—20
     RF generator R&S SMT—06                SN: 100972                15—Jun—15 (in house check Oct—18)                     In house check: Oct—20
     Network Analyzer Agilent E8358A        SN: US41080477            31—Mar—14 (in house check Oct—18)                     In house check: Oct—19


                                            Name                                     Function                               Signature
     Calibrated by:                         Leif Klysner                             Laboratory Technician               ge/ %


     Approved by:                           Ratia Pokovie                            Technical Manager                    Wr/_

                                                                                                                           Issued: July 17, 2019
     This calibration certificate shall not be reproduced except in full without written approval of the laboratory.


    Certificate No: D1750V2—1003_Jul19                                    Page 1 of 8


TTL                                                                                          CAICT



)
Calibration Laboratory of
Schmid & Partner
  Engineering AG
                                                                               S
                                                                               C
                                                                                   Schweizerischer Kalibrierdienst
                                                                                   Service suisse d‘étalonnage
                                                                                   Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                   S   Swiss Calibration Service



Accredited by the Swiss Accreditation Service (SAS)                            Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
 Multilateral Agreement for the recognition of calibration certificates

Glossary:
TSL                          tissue simulating liquid
ConvF                        sensitivity in TSL / NORM x.y,z
N/A                          not applicable or not measured

Calibration is Performed According to the Following Standards:
   a) IEEE Std 1528—2013, "IEEE Recommended Practice for Determining the Peak Spatial—
      Averaged Specific Absorption Rate (SAR) in the Human Head from Wireless
      Communications Devices: Measurement Techniques", June 2013
   b) IEC 62209—1, "Measurement procedure for the assessment of Specific Absorption Rate
      (SAR) from hand—held and body—mounted devices used next to the ear (frequency range of
      300 MHz to 6 GHz)", July 2016
   c) IEC 62209—2, "Procedure to determine the Specific Absorption Rate (SAR) for wireless
      communication devices used in close proximity to the human body (frequency range of 30
      MHz to 6 GHz)", March 2010
   d) KDB 865664, "SAR Measurement Requirements for 100 MHz to 6 GHz"

Additional Documentation:
   e) DASY4/5 System Handbook

Methods Applied and Interpretation of Parameters:
   e Measurement Conditions: Further details are available from the Validation Report at the end
     of the certificate. All figures stated in the certificate are valid at the frequency indicated.
   e Antenna Parameters with TSL: The dipole is mounted with the spacer to position its feed
     point exactly below the center marking of the flat phantom section, with the arms oriented
     paralle! to the body axis.
   e Feed Point Impedance and Return Loss: These parameters are measured with the dipole
     positioned under the liquid filled phantom. The impedance stated is transformed from the
     measurement at the SMA connector to the feed point. The Return Loss ensures low
     reflected power. No uncertainty required.
   e Electrical Delay: One—way delay between the SMA connector and the antenna feed point.
          No uncertainty required.
     e    SAR measured: SAR measured at the stated antenna input power.
     e    SAR normalized: SAR as measured, normalized to an input power of 1 W at the antenna
          connector.
     e    SAR for nominal TSL parameters: The measured TSL parameters are used to calculate the
          nominal SAR result.
  The reported uncertainty of measurement is stated as the standard uncertainty of measurement
  multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
  probability of approximately 95%.




Certificate No: D1750V2—1003_Jul19                               Page 2 of 8


TTL
V




Measurement Conditions
    DASY system configuration, as far as not given on page 1.
      DASY Version                                              DASYS                             V52.10.2
      Extrapolation                                   Advanced Extrapolation
      Phantom                                         Modular Flat Phantom
      Distance Dipole Center — TSL                              10 mm                            with Spacer
     Zoom Scan Resolution                               dx, dy, dz =5 mm
      Frequency                                         1750 MHz # 1 MHz



Head TSL parameters
   The following parameters and calculations were applied.
                                                                Temperature      Permittivity         Conductivity
      Nominal Head TSL parameters                                  22.0 °C          40.1               1.37 mho/m
      Measured Head TSL parameters                              (22.0 £0.2) °C   40.2 + 6 %         1.34 mho/m # 6 %
      Head TSL temperature change during test                      <0.5 °C           ————                    ———

SAR result with Head TSL

      SAR averaged over 1 cm* (1 g) of Head TSL                  Condition
      SAR measured                                       250 mW input power                     9.01 Wikg
      SAR for nominal Head TSL parameters                    normalized to 1W        36.6 Wikg * 17.0 % (k=2)

      SAR averaged over 10 cm* (10 g) of Head TSL                condition
      SAR measured                                       250 mW input power                     4.77 Wikg
      SAR for nominal Head TSL parameters                    normalized to 1W         19.3 Wikg £ 16.5 % (k=2)



Body TSL parameters
   The following parameters and calculations were applied.
                                                                Temperature      Permittivity         Conductivity
      Nominal Body TSL parameters                                  22.0 °C          53.4               1.49 mho/m
      Measured Body TSL parameters                              (22.0 £0.2) °C   53.5 + 6 %         1.46 mho/m * 6 %
      Body TSL temperature change during test                      <0.8 °C           ————                    ———

SAR result with Body TSL

      SAR averaged over 1 cm‘ (1 g) of Body TSL                  Condition
      SAR measured                                        250 mW input power                    9.07 W/kg

      SAR for nominal Body TSL parameters                    normalized to 1W         36.8 Wikg * 17.0 % (k=2)


      SAR averaged over 10 cm* (10 g) of Body TSL                 condition
      SAR measured                                        250 mW input power                    4.83 Wikg
      SAR for nominal Body TSL parameters                    normalized to 1W         19.5 Wikg * 16.5 % (k=2)




Certificate No: D1750V2—1003_Jul19                     Page 3 of 8


                                                                                                                        M
                                                                                                                           mf
                                                                                                         >
css in¥P




/R
y




     Appendix (Additional assessments outside the scope of SCS 0108)

     Antenna Parameters with Head TSL

           Impedance, transformed to feed point                                           51.0 Q + 0.1 jQ
           Return Loss                                                                       — 39.9 dB



     Antenna Parameters with Body TSL

           Impedance, transformed to feed point                                           45.6 Q + 0.2 jQ
           Return Loss                                                                       —26.7 dB




     General Antenna Parameters and Design

          LEIectricaI Delay (one direction)                                                   1.213 ns


     After long term use with 100W radiated power, only a slight warming of the dipole near the feedpoint can be measured.

     The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the
     second arm of the dipole. The antenna is therefore short—circuited for DC—signals. On some of the dipoles, small end caps
     are added to the dipole arms in order to improve matching when loaded according to the position as explained in the
     "Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still
     according to the Standard.
     No excessive force must be applied to the dipole arms, because they might bend or the soldered connections near the
     feedpoint may be damaged.


     Additional EUT Data

           Manufactured by                                                                    SPEAG




     Certificate No: D1750V2—1003_Jul19                       Page 4 of 8


                                                                                   CAICT


(3S
 DASY5 Validation Report for Head TSL

                                                                                      Date: 16.07.2019

 Test Laboratory: SPEAG, Zurich, Switzerland

 DUT: Dipole 1750 MHz; Type: D1750V2; Serial: D1750V2 — SN:1003

 Communication System: UID 0 — CW; Frequency: 1750 MHz
 Medium parameters used: f= 1750 MHz; 0 = 1.34 S/m; s = 40.2; p = 1000 kg/m‘
 Phantom section: Flat Section
 Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19—2011)

 DASY52 Configuration:

     e    Probe: EX3DV4 — SN7349; ConvF(8.67, 8.67, 8.67) @ 1750 MHz; Calibrated: 29.05.2019

     e    Sensor—Surface: 1.4mm (Mechanical Surface Detection)

     e    Electronics: DAE4 Sn601; Calibrated: 30.04.2019

     *    Phantom: Flat Phantom 5.0 (front); Type: QD 000 P50 AA; Serial: 1001

     &    DASY52 52.10.2(1504); SEMCAD X 14.6.12(7470)


 Dipole Calibration for Head Tissue/Pin=250 mW, d=10mm/Zoom Scan (7x7x7)/Cube 0:
 Measurement grid: dx=5mm, dy=5mm, dz=5mm
 Reference Value = 106.1 V/m; Power Drift = 0.03 dB
 Peak SAR (extrapolated) = 16.6 W/kg
 SAR(I g) =9.01 W/kg; SAR(10 g) = 4.77 W/kg
 Maximum value of SAR (measured) = 13.9 W/kg


         dB
          0


          —3.40


          —6.80


          —10.20


          —13.60


          —17.00
                     0 dB = 13.9 W/kg = 11.43 dBW/kg




  Certificate No: D1750V2—1003_Jul19              Page 5 of 8


                                                                                                                            CAICT


®       Impedance Measurement Plot for Head TSL




               File    View   Channel     Sweep    Calibration Trace   Scale     Marker   System   Window   Help

                                                                                                           1.750000 GHz 51.016 0
                                                                                                               12.826 pH —141.03 m0
                                                                                                         , 11750000 GHz 10155 mU
                                                                                                                            7.8224 °



                               Ch1Aug= 20
                      Chi: Start 1.55000 GHz   ——                                                                           Stop 1.95000 GHz

                                                                                                              50000   GHz




                      00

                      00
                      00
                      00
                      00           1    =
                      Chi: Start 1 55000 GHa   ——                                                                           Stop 1.95000 GHz

                 Status       CH 1:      17                  ] C* 1—Port                  Avg=20 Delay                           LCL




         Certificate No: D1750V2—1003_Jul19                                    Page 6 of 8




Nemvrug n nagn n n m n m on      n n >         —


                                                                                   CAICT


(3S
 DASY5 Validation Report for Body TSL

                                                                                      Date: 16.07.2019

 Test Laboratory: SPEAG, Zurich, Switzerland

 DUT: Dipole 1750 MHz; Type: D1750V2; Serial: D1750V2 — SN:1003

 Communication System: UID 0 — CW; Frequency: 1750 MHz
 Medium parameters used: f = 1750 MHz; 0 = 1.46 S/m; s = 53.5; p = 1000 kg/m3
 Phantom section: Flat Section
 Measurement Standard: DASY5 (IEEE/IEC/ANSI €63.19—2011)

 DASY52 Configuration:

     e    Probe: EX3DV4 — SN7349; ConvF(8.45, 8.45, 8.45) @ 1750 MHz; Calibrated: 29.05.2019

     e    Sensor—Surface: 1.4mm (Mechanical Surface Detection)

     e    Electronics: DAE4 Sn601; Calibrated: 30.04.2019

     e    Phantom: Flat Phantom 5.0 (back); Type: QD 000 P50 AA; Serial: 1002

     «_   DASY52 52.10.2(1504); SEMCAD X 14.6.12(7470)


 Dipole Calibration for Body Tissue/Pin=250 mW, d=10mm/Zoom Scan (7x7x7)/Cube 0:
 Measurement grid: dx=5mm, dy=5mm, dz=5mm
 Reference Value = 101.3 V/m; Power Drift =—0.06 dB
 Peak SAR (extrapolated) = 16.0 W/kg
 SAR(I g) = 9.07 W/kg; SAR(10 g) =4.83 W/kg
 Maximum value of SAR (measured) = 13.6 W/kg




          —3.20


          —6.40


          —9.60


          —12.80


          —16.00
                     0 dB = 13.6 W/kg = 11.34 dBW/kg




  Certificate No: D1750V2—1003_Jul19             Page 7 of 8


<TrL                                                                                                                  CAICT



       Impedance Measurement Plot for Body TSL




            IEile    Yiew    Channel   Sweep Calibration   Trace   Scale     Marker System   Window   Help

                                                                                                      1.750000 GHz      45.607 C
                                                                                                          17.866 pH   196. 45 mQ
                                                                                                      1.750000 GHz    45.992 mU
                                                                                                                          17738 ®




                             Ch1Aug= 20
                    Chi: Start 155000 GHz   ——                                                                        Stop 1.95000 GHz




                  Status    CH 1:                          C"1—Port                  Ayg=20 Delay                          LCE




        Certificate No: D1750V2—1003_Jul19                                 Page 8 of 8




~ov oaccen ce >       w9        —           —


TTL                                                                                                                             CAICT
                                                                                                               «s se ks e se se k se es           w in s




     3      s                                                        «19199
Calibration Laboratory of                                         s\“\g"’n}                                g      Schweizerischer Kalibrierdienst
Schmid & Partner                                                 ;IB\EE\:/(&%                              c Service suisse d‘étalonnage
  Engineering AG                                                 tm®                                              Servizio svizzero di taratura
                                 5       ;                       Zzzany                                    S         x      ose           a
Zeughausstrasse 43, 8004 Zurich, Switzerland                       * I/-\\ \®                                     Swiss Calibration Service
                                                                     "thilals


Accredited by the Swiss Accreditation Service (SAS)                                                        Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates

Client       CTTL (Auden)                                                                      Certificate No: D1900V2—5d101_Jul19

CALIBRATION CERTIFICATE
 Object                               D1900V2 — SN:5d101


 Calibration procedure(s)             QA CAL—O5.v11
                                      Calibration Procedure for SAR Validation Sources between 0.7—3 GHz



 Calibration date:                    July 17, 2019


 This calibration certificate documents the traceability to national standards, which realize the physicalunits of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)


 Primary Standards                      ID #                      Cal Date (Certificate No.)                           Scheduled Calibration
 Power meter NRP                        SN: 104778                03—Apr—19 (No. 217—02892/02893)                      Apr—20
 Power sensor NRP—Z291                  SN: 103244                03—Apr—19 (No. 217—02892)                            Apr—20
 Power sensor NRP—Z91                   SN: 103245                03—Apr—19 (No. 217—02893)                            Apr—20
 Reference 20 dB Attenuator             SN: 5058 (20k)            04—Apr—19 (No. 217—02894)                            Apr—20
 Type—N mismatch combination            SN: 5047.2 / 06827        04—Apr—19 (No. 217—02895)                            Apr—20
 Reference Probe EX3DV4                 SN: 7349                  29—May—19 (No. EX3—7349_May19)                       May—20
 DAE4                                   SN: 601                   30—Apr—19 (No. DAE4—601_Apr19)                       Apr—20


 Secondary Standards                    ID #                      Check Date (in house)                                Scheduled Check
 Power meter E4419B                     SN: GB39512475            30—Oct—14 (in house check Feb—19)                    In house check: Oct—20
 Power sensor HP 8481A                  SN: US37202783            07—Oct—15 (in house check Oct—18)                    In house check: Oct—20
 Power sensor HP 8481A                  SN: MY41092317            07—Oct—15 (in house check Oct—18)                    In house check: Oct—20
 RF generator R&S SMT—06                SN: 100972                15—Jun—15 (in house check Oct—18)                    In house check: Oct—20
 Network Analyzer Agilent E8358A        SN: US41080477            31—Mar—14 (in house check Oct—18)                    In house check: Oct—19


                                        Name                                    Function                               Signature
 Calibrated by:                        Michael Weber                            Laboratory Technician



 Approved by:                          KatJa Pokovic                            Technical Manager                  %%%



                                                                                                                      Issued: July 19, 2019
 This calibration certificate shall not be reproduced exceptin full without written approval of the laboratory.


Certificate No: D1900V2—5d101_Jul19                                   Page 1 of 8


TTL                                                                                          CAICT
                                                                              ro+ se k sea c nz ud ks             Nulrvrviw




Calibration Laboratory of                                                     S   Schweizerischer Kalibrierdienst
Schmid & Partner                                                              c   Service suisse d‘étalonnage
  Engineering AG                                                                  Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                  S   Swiss Calibration Service



Accredited by the Swiss Accreditation Service (SAS)                           Accreditation No.: SCS 0108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreementfor the recognition of calibration certificates

Glossary:
TSL                          tissue simulating liquid
ConvF                        sensitivity in TSL / NORM x,.y.z
N/A                          not applicable or not measured

Calibration is Performed According to the Following Standards:
   a) IEEE Std 1528—2013, "IEEE Recommended Practice for Determining the Peak Spatial—
      Averaged Specific Absorption Rate (SAR) in the Human Head from Wireless
      Communications Devices: Measurement Techniques", June 2013
   b) IEC 62209—1, "Measurement procedure for the assessment of Specific Absorption Rate
      (SAR) from hand—held and body—mounted devices used next to the ear (frequency range of
      300 MHz to 6 GHz)", July 2016
   c) IEC 62209—2, "Procedure to determine the Specific Absorption Rate (SAR) for wireless
      communication devices used in close proximity to the human body (frequency range of 30
       MHz to 6 GHz)", March 2010
   d) KDB 865664, "SAR Measurement Requirements for 100 MHz to 6 GHz"

Additional Documentation:
   e) DASY4/5 System Handbook

Methods Applied and Interpretation of Parameters:
    e    Measurement Conditions: Further details are available from the Validation Report at the end
         of the certificate. All figures stated in the certificate are valid at the frequency indicated.
    e    Antenna Parameters with TSL: The dipole is mounted with the spacer to position its feed
         point exactly below the center marking of the flat phantom section, with the arms oriented
         parallel to the body axis.
    e    Feed Point Impedance and Return Loss: These parameters are measured with the dipole
         positioned under the liquid filled phantom. The impedance stated is transformed from the
         measurement at the SMA connector to the feed point. The Return Loss ensures low
         reflected power. No uncertainty required.
    e    Electrical Delay: One—way delay between the SMA connector and the antenna feed point.
         No uncertainty required.
    e    SAR measured: SAR measured at the stated antenna input power.
    e    SAR normalized: SAR as measured, normalized to an input power of 1 W at the antenna
         connector.
    e    SAR for nominal TSL parameters: The measured TSL parameters are used to calculate the
         nominal SAR result.
  The reported uncertainty of measurement is stated as the standard uncertainty of measurement
  multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
  probability of approximately 95%.




Certificate No: D1900V2—5d101_Jul19                             Page 2 of 8




                                                                                         t   nege > > — >


                                                                                                     CAICT



Measurement Conditions
   DASY system configuration, as far as not given on page 1.
     DASY Version                                               DASYS5                             V52.10.2
     Extrapolation                                   Advanced Extrapolation
      Phantom                                         Modular Flat Phantom
      Distance Dipole Center — TSL                              10 mm                             with Spacer
     Zoom Scan Resolution                               dx, dy, dz =5 mm
      Frequency                                         1900 MHz + 1 MHz



Head TSL parameters
   The following parameters and calculations were applied.
                                                                Temperature       Permittivity         Conductivity
      Nominal Head TSL parameters                                  22.0 °C           40.0               1.40 mho/m
      Measured Head TSL parameters                              (22.0 + 0.2) °C   41.5 26 %          1.37 mho/m + 6 %
      Head TSL temperature change during test                      <0.5 °C


SAR result with Head TSL

      SAR averaged over 1 cm* (1 g) of Head TSL                  Condition
      SAR measured                                        250 mW input power                  9.71 W/kg
      SAR for nominal Head TSL parameters                     normalized to 1W         39.7 Wikg + 17.0 % (k=2)

      SAR averaged over 10 cm* (10 g) of Head TSL                 condition
      SAR measured                                        250 mW input power                  5.12 Wikg
      SAR for nominal Head TSL parameters                     normalized to 1W         20.8 Wikg + 16.5 %(k=2)


Body TSL parameters
    The following parameters and calculations were applied.
                                                                Temperature       Permittivity         Conductivity
      Nominal Body TSL parameters                                  22.0 °C           53.3               1.52 mho/m
      Measured Body TSL parameters                              (22.0 £ 0.2) °C   54.1 £6 %          1.48 mho/m + 6 %
      Body TSL temperature change during test                      <0.5 °C

SAR result with Body TSL

      SAR averaged over 1 cm* (1 g) of Body TSL                  Condition
      SAR measured                                        250 mW input power                  9.74 Wikg
      SAR for nominal Body TSL parameters                     normalized to 1W         39.7 Wikg + 17.0 % (k=2)

      SAR averaged over 10 cm* (10 g) of Body TSL                 condition
      SAR measured                                        250 mW input power                     5.17 Wikg
      SAR for nominal Body TSL parameters                     normalized to 1W         20.9 W/kg + 16.5 % (k=2)




Certificate No: D1900V2—5d101_Jul19                    Page 3 of 8


TTL                                                                                                     CAICT


(
                                                                                                                   «_   en rv ies




Appendix (Additional assessments outside the scope of SCS 0108)

Antenna Parameters with Head TSL

      Impedance, transformed to feed point                                           50.7 Q + 4.6 jQ
      Return Loss                                                                       —26.6 dB



Antenna Parameters with Body TSL

      Impedance, transformed to feed point                                           46.5 Q + 6.4 jQ
      Return Loss                                                                       —22.4 dB




General Antenna Parameters and Design

      Electrical Delay (one direction)                                                   1.203 ns


After long term use with 100W radiated power, only a slight warming of the dipole near the feedpoint can be measured.

The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the
second arm of the dipole. The antenna is therefore short—circuited for DC—signals. On some of the dipoles, small end caps
are added to the dipole arms in order to improve matching when loaded according to the position as explained in the
"Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still
according to the Standard.
No excessive force must be applied to the dipole arms, because they might bend or the soldered connections near the
feedpoint may be damaged.


Additional EUT Data

      Manufactured by                                                                    SPEAG




Certificate No: D1900V2—5d101_Jul19                      Page 4 of 8



Document Created: 2019-11-05 14:17:40
Document Modified: 2019-11-05 14:17:40