Test Report

FCC ID: 2ALZG-P32

Test Report

Download: PDF
FCCID_4369127

                                            FCC PART 15.249
                                               TEST REPORT
                                                               For

     Qingdao Magene Intelligence Technology Co., Ltd.
         HaoQiGongChang No. 512 Xuzhou Road No. 79, Shinan District Qingdao, Shandong China



                                             FCC ID: 2ALZG-P32


             Report Type:                                         Product Type:
            Original Report                                      Magene Dual-protocol Crank Power Meter



                       Test Engineer:         Max Min


                      Report Number: RKSA190505001-00B


                         Report Date:        2019-07-18

                                              Oscar Ye
                        Reviewed By:          RF Leader

                   Test Laboratory:          Bay Area Compliance Laboratories Corp. (Kunshan)
                                             No.248 Chenghu Road,Kunshan,Jiangsu province,China
                                             Tel: +86-0512-86175000
                                             Fax: +86-0512-88934268
                                             www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. This report is valid only with a valid
digital signature. The digital signature may be available only under the Adobe software above version 7.0.


Bay Area Compliance Laboratories Corp. (Kunshan)                                                                        Report No.: RKSA190505001-00B


                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................4
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................5
  EXTERNAL I/O CABLE..................................................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................6
SUMMARY OF TEST RESULTS ...............................................................................................................................8
TEST EQUIPMENT LIST ...........................................................................................................................................9

FCC§15.203 - ANTENNA REQUIREMENT............................................................................................................10
  APPLICABLE STANDARD ............................................................................................................................................10
  ANTENNA CONNECTOR CONSTRUCTION ....................................................................................................................10
FCC§15.205, §15.209&§15.249- RADIATED EMISSIONS& OUT OF BAND EMISSION ................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  EUT SETUP ................................................................................................................................................................11
  TEST EQUIPMENT SETUP ............................................................................................................................................12
  TEST PROCEDURE ......................................................................................................................................................12
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................13
  TEST RESULTS SUMMARY ..........................................................................................................................................13
  TEST DATA ................................................................................................................................................................13
FCC §15.215(C) – 20 DB BANDWIDTH TESTING ................................................................................................18
  APPLICABLE STANDARD ............................................................................................................................................18
  TEST PROCEDURE ......................................................................................................................................................18
  TEST DATA ................................................................................................................................................................18




FCC Part 15.249                                                                                                                                         Page 2 of 19


Bay Area Compliance Laboratories Corp. (Kunshan)                             Report No.: RKSA190505001-00B

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

        Applicant            Qingdao Magene Intelligence Technology Co., Ltd.
      Tested Model           P32
      Product Type           Magene Dual-protocol Crank Power Meter
        Dimension            212mm(L)* 47mm(W)* 22mm(H)
      Power Supply           DC 3V from battery

*All measurement and test data in this report was gathered from production sample serial number: 20190505001.
(Assigned by BACL, Kunshan). The EUT was received on 2019-05-05.

Objective
This type approval report is prepared on behalf of Qingdao Magene Intelligence Technology Co., Ltd. in
accordance with Part 2-Subpart J, and Part 15-Subparts A and C of the Federal Communications
Commission rules.

The tests were performed in order to determine compliance with FCC Part 15, Subpart C, and section
15.203, 15.205, 15.209 and 15.249 rules.


Related Submittal(s)/Grant(s)

FCC Part15.247 DTS submissions with FCC ID: 2ALZG-P32.

Test Methodology

All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.

All radiated and conducted emissions measurement was performed at Bay Area Compliance Lab Corp.
(Kunshan). The radiated testing was performed at an antenna-to-EUT distance of 3 meters.




FCC Part 15.249                                                                                   Page 3 of 19


Bay Area Compliance Laboratories Corp. (Kunshan)                          Report No.: RKSA190505001-00B

Measurement Uncertainty

                               Item                                             Uncertainty

              AC Power Lines Conducted Emissions                                   3.19 dB
                   RF conducted test with spectrum                                  0.9dB
                  RF Output Power with Power meter                                  0.5dB
                                          30MHz~1GHz                               6.11dB
                                           1GHz~6GHz                               4.45dB
     Radiated emission
                                           6GHz~18GHz                              5.23dB
                                          18GHz~40GHz                              5.65dB
                         Occupied Bandwidth                                        0.5kHz
                            Temperature                                             1.0℃
                             Humidity                                                6%

Otherwise required by the applicant or Product Regulations, Decision Rule in this report did not consider
the uncertainty.


Test Facility
The test site used by Bay Area Compliance Laboratories Corp. (Kunshan) to collect test data is located on
the No.248 Chenghu Road, Kunshan, Jiangsu province, China.

Bay Area Compliance Laboratories Corp. (Kunshan) Lab is accredited to ISO/IEC 17025 by A2LA (Lab
code: 4323.01) and the FCC designation No. CN1185 under the FCC KDB 558074 D01 and CAB
identifier CN0004 under the ISED requirement. The facility also complies with the radiated and AC line
conducted test site criteria set forth in ANSI C63.4-2014.




FCC Part 15.249                                                                               Page 4 of 19


Bay Area Compliance Laboratories Corp. (Kunshan)               Report No.: RKSA190505001-00B

SYSTEM TEST CONFIGURATION
Justification
Channel list:

                                                               Frequency
                    Channel
                                                                 (MHz)
                       1                                          2457


EUT Exercise Software

No software was used during the test.


Support Equipment List and Details

     Manufacturer                 Description       Model                  Serial Number

            /                           /              /                         /



External I/O Cable

                                    Length
   Cable Description                               From Port                    To
                                     (m)
            /                           /              /                         /




FCC Part 15.249                                                                 Page 5 of 19


Bay Area Compliance Laboratories Corp. (Kunshan)                   Report No.: RKSA190505001-00B

Block Diagram of Test Setup

For Radiated Emissions(Below 1GHz):


       Turntable
       2m Diameter




                                                           EUT




                                                                        1.0 Meter
                                 Non-Conductive Table
                                 80cm above Ground Plane

                                                       1.5 Meter




FCC Part 15.249                                                                     Page 6 of 19


Bay Area Compliance Laboratories Corp. (Kunshan)                   Report No.: RKSA190505001-00B

For Radiated Emissions(Above 1GHz):


       Turntable
       2m Diameter




                                                            EUT




                                                                        1.0 Meter
                                 Non-Conductive Table
                                 150cm above Ground Plane

                                                       1.5 Meter




FCC Part 15.249                                                                     Page 7 of 19


Bay Area Compliance Laboratories Corp. (Kunshan)                         Report No.: RKSA190505001-00B


SUMMARY OF TEST RESULTS

           FCC Rules                         Description of Test                     Result

             §15.203                        Antenna Requirement                    Compliant
                                                                                 Not Applicable
            §15.207(a)                      Conduction Emissions
                                                                                  (See Note)
                                       Radiated Emissions& Out of Band
     15.205, §15.209, §15.249                                                      Compliant
                                                  Emission
           §15.215 (c)                        20 dB Bandwidth                      Compliant


Note: The EUT is powered by battery.




FCC Part 15.249                                                                           Page 8 of 19


Bay Area Compliance Laboratories Corp. (Kunshan)                                Report No.: RKSA190505001-00B

TEST EQUIPMENT LIST

                                                                   Serial             Calibration     Calibration
    Manufacturer              Description              Model
                                                                  Number                 Date          Due Date
                                    Radiated Emission Test(Chamber 1#)
  Rohde & Schwarz          EMI Test Receiver           ESCI             100195         2018-11-30     2019-11-29
    Sunol Sciences         Broadband Antenna            JB3           A090413-1        2016-12-26     2019-12-25
  Sonoma Instrunent           Pre-amplifier            310N             171205         2018-08-14     2019-08-13
  Rohde & Schwarz          Auto test Software         EMC32             100361              /               /
   MICRO-COAX                Coaxial Cable            Cable-8             008          2018-08-15     2019-08-14
   MICRO-COAX                Coaxial Cable            Cable-9             009          2018-08-15     2019-08-14
   MICRO-COAX                Coaxial Cable            Cable-10            010          2018-08-15     2019-08-14
                                    Radiated Emission Test(Chamber 2#)
  Rohde & Schwarz          EMI Test Receiver           ESU40            100207         2018-08-27     2019-08-26
  ETS-LINDGREN               Horn Antenna               3115           9207-3900       2017-07-15     2020-07-14
  ETS-LINDGREN               Horn Antenna               3116           00084159        2016-12-12     2019-12-11
 MICRO-TRONICS                Notch Filter           BRM50702            G024          2018-08-05     2019-08-04
  A.H.Systems, inc             Amplifier               2641-1             491          2019-02-20     2020-02-19
   EM Electronics
                               Amplifier            EM18G40G            060726         2019-03-22     2020-03-21
    Corporation
       Narda                   Attenuator              10dB               010          2018-08-15     2019-08-14
  Rohde & Schwarz          Auto test Software         EMC32             100361              /               /
   MICRO-COAX                Coaxial Cable            Cable-6             006          2018-08-15     2019-08-14
   MICRO-COAX                Coaxial Cable            Cable-11            011          2018-08-15     2019-08-14
   MICRO-COAX                Coaxial Cable            Cable-12            012          2018-08-15     2019-08-14
   MICRO-COAX                Coaxial Cable            Cable-13            013          2018-08-15     2019-08-14
                                                RF Conducted Test
  Rohde & Schwarz           Signal Analyzer           FSIQ26          836131/009       2018-11-30     2019-11-29
        Narda                  Attenuator              10dB               010          2018-08-15     2019-08-14
       Magene                   RF Cable                  /                 /          Each Time            /

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Kunshan) attests that all calibrations have
been performed in accordance to requirements that traceable to National Primary Standards and International System
of Units (SI).




FCC Part 15.249                                                                                     Page 9 of 19


Bay Area Compliance Laboratories Corp. (Kunshan)                        Report No.: RKSA190505001-00B

FCC§15.203 - ANTENNA REQUIREMENT
Applicable Standard
For intentional device, according to §15.203, an intentional radiator shall be designed to ensure that no
antenna other than that furnished by the responsible party shall be used.


Antenna Connector Construction
The EUT has a PCB antenna for ANT+, which the antenna gain is 0 dBi, fulfill the requirement of this
section. Please refer to the EUT photos.


Result: Compliant.




FCC Part 15.249                                                                            Page 10 of 19


Bay Area Compliance Laboratories Corp. (Kunshan)                           Report No.: RKSA190505001-00B


FCC§15.205, §15.209&§15.249- RADIATED EMISSIONS& OUT OF BAND
EMISSION
Applicable Standard

As per FCC§15.249 (a), except as provided in paragraph (b) of this section, the field strength of
emissions from intentional radiators operated within these frequency bands shall comply with the
following:


                                       Field strength of fundamental         Field strength of harmonics
      Fundamental frequency
                                              (millivolts/meter)                  (microvolts/meter)

           902–928 MHz                               50                                 500

         2400–2483.5 MHz                             50                                 500

          5725–5875 MHz                              50                                 500

          24.0–24.25 GHz                            250                                 2500


As per FCC§15.249 (c), Field strength limits are specified at a distance of 3 meters.

(d) Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated
by at least 50 dB below the level of the fundamental or to the general radiated emission limits in §15.209,
whichever is the lesser attenuation.

EUT Setup
Below 1 GHz:




FCC Part 15.249                                                                                Page 11 of 19


Bay Area Compliance Laboratories Corp. (Kunshan)                          Report No.: RKSA190505001-00B

Above 1 GHz:




The radiated emission and out of band emission tests were performed in the 3 meters chamber test site,
using the setup accordance with the ANSI C63.10-2013. The specification used was the FCC
15.209/15.205 and FCC 15.249 limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.


Test Equipment Setup
The system was investigated from 30 MHz to 25 GHz.

During the radiated emission test, the EMI test receiver Setup was set with the following configurations:

   Frequency Range               RBW               Video B/W              IF B/W              Detector

  30 MHz – 1000 MHz             120 kHz              300 kHz              120 kHz                QP

                                 1MHz                3 MHz                   /                   PK
      Above 1GHz
                                 1MHz                3 MHz                   /                   Ave



Test Procedure
Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

Data was recorded in Quasi-peak detection mode for frequency range of 30 MHz-1 GHz, peak and
Average detection modes for frequencies above 1 GHz.




FCC Part 15.249                                                                               Page 12 of 19


Bay Area Compliance Laboratories Corp. (Kunshan)                        Report No.: RKSA190505001-00B

Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude (dBμV /m) = Meter Reading (dBμV) + Antenna Factor (dB/m) + Cable Loss
        (dB) - Amplifier Gain (dB)

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin (dB) = Limit (dBμV/m) – Corrected Amplitude (dBμV /m)


Test Results Summary
According to the data in the following table, the EUT complied with the FCC Part 15.209 &15.205 &
15.249.


Test Data
Environmental Conditions

Temperature:                  21.2C ~24.2C
Relative Humidity:               48%~50%
ATM Pressure:               101.1kPa ~101.2kPa

The testing was performed by Max Min from 2019-06-01 to 2019-06-03.

Test Mode: Transmitting




FCC Part 15.249                                                                            Page 13 of 19


Bay Area Compliance Laboratories Corp. (Kunshan)                                                Report No.: RKSA190505001-00B

Spurious Emission Test:

30MHz-1GHz
(Pre-scan in the X,Y and Z axes of orientation, the worst case Z-axis of orientation was recorded)

                                                                 Full Spectrum


                            100

                            80
          LevelinindBμV/m
                    dBμV/




                            60

                            40
          Level




                            20

                             0


                              30M         50     60    80 100M               200          300   400   500      800     1G
                                                                   Frequency in Hz


                                    Corrected
                                                         Rx Antenna                             Corrected
   Frequency                        Amplitude                                    Turntable                    Limit         Margin
                                                                                                 Factor
     (MHz)                          Quasi-peak        Height      Polar           Degree                    (dBμV/m)         (dB)
                                                                                                 (dB/m)
                                    (dBμV/m)           (cm)       (H/V)
    41.361800                         18.75           100.0         V              330.0          -17.8      40.00          21.25
    65.120200                         16.27           100.0         V              166.0          -23.3      40.00          23.73
    96.046960                         19.40           200.0         H               0.0           -22.9      43.50          24.10
   128.004800                         17.83           100.0         H               7.0           -19.5      43.50          25.67
   178.971120                         25.51           100.0         H              31.0           -17.6      43.50          17.99
   331.630600                         21.49           200.0         H              353.0          -15.3      46.00          24.51




FCC Part 15.249                                                                                                      Page 14 of 19


Bay Area Compliance Laboratories Corp. (Kunshan)                                                 Report No.: RKSA190505001-00B

1GHz-18GHz
(Pre-scan in the X,Y and Z axes of orientation, the worst case Z-axis of orientation was recorded.)

Note:
1. This test was performed with the 2.4-2.5GHz notch filter.
2. Corrected Factor (dB/m) = Antenna factor (RX) (dB/m) + Cable Loss (dB) – Amplifier Factor (dB)
   Corrected Amplitude (dBμV /m) = Corrected Factor (dB/m) + Reading (dBμV)
   Margin (dB) = Limit (dBμV/m) – Corrected Amplitude (dBμV /m)

                                                        Channel Frequency: 2457MHz

                                                                Full Spectrum


                              100

                              80
                    dBμV/m
                      dBμV/




                              60
                 inin




                              40
            Level
           Level




                              20

                               0
                                1G                 2G          3G       4G      5G     6         8     10G            18G
                                                                     Frequency in Hz


                                     Corrected Amplitude       Rx Antenna                            Corrected
  Frequency                                                                          Turntable                     Limit    Margin
                                     MaxPeak     Average    Height    Polar                           Factor
    (MHz)                                                                             Degree                     (dBμV/m)    (dB)
                                    (dBμV /m) (dBμV /m)      (cm)     (H/V)                           (dB/m)
 1629.000000                           ---        26.54     100.0       V              56.0            -9.5       54.00     27.46
 1629.000000                          33.95       ---        100.0        V            56.0            -9.5       74.00     40.05
 2948.200000                          39.30       ---        100.0        V            327.0           -4.6       74.00     34.70
 2948.200000                           ---       28.64       100.0        V            327.0           -4.6       54.00     25.36
 4914.000000                          42.06       ---        150.0        H                0.0         -0.5       74.00     31.94
 4914.000000                           ---       32.46       150.0        H                0.0         -0.5       54.00     21.54
 7371.000000                          45.03       ---        100.0        H            49.0             5.9       74.00     28.97
 7371.000000                           ---       37.89       100.0        H            49.0             5.9       54.00     16.11
10037.200000                           ---       38.44       200.0        H            200.0            8.3       54.00     15.56
10037.200000                          48.97       ---        200.0        H            200.0            8.3       74.00     25.03
17452.600000                           ---       42.38       200.0        H            307.0           14.0       54.00     11.62
17452.600000                          52.89       ---        200.0        H            307.0           14.0       74.00     21.11




FCC Part 15.249                                                                                                      Page 15 of 19


Bay Area Compliance Laboratories Corp. (Kunshan)                                 Report No.: RKSA190505001-00B

18GHz-25GHz
(Pre-scan in the X,Y and Z axes of orientation, the worst case Z-axis of orientation was recorded)

                                                    Horizontal




                      Date:3.JUN.2019 16:34:32




                                                      Vertical




                      Date:3.JUN.2019 16:59:43




FCC Part 15.249                                                                                      Page 16 of 19


Bay Area Compliance Laboratories Corp. (Kunshan)                                 Report No.: RKSA190505001-00B

Fundamental Test & Restricted Bands Emissions Test:
(Pre-scan in the X, Y and Z axes of orientation, the worst case Z-axis of orientation was recorded.)

Note:
1. Corrected Factor (dB/m) = Antenna factor (RX) (dB/m) + Cable Loss (dB) – Amplifier Factor (dB)
   Corrected Amplitude (dBμV /m) = Corrected Factor (dB/m) + Reading (dBμV)
   Margin (dB) = Limit (dBμV/m) – Corrected Amplitude (dBμV /m)

                   Corrected Amplitude       Rx Antenna                 Corrected
  Frequency                                                   Turntable             Limit                    Margin
                   MaxPeak     Average    Height    Polar                Factor
    (MHz)                                                      Degree             (dBμV/m)                    (dB)
                  (dBμV /m) (dBμV /m)      (cm)     (H/V)                (dB/m)
                                       Fundamental Test : 2457MHz
 2457.000000         89.77           ---         100.0       H          320.0          3.0        114.00      24.23
 2457.000000           ---          89.35        100.0       H          320.0          3.0         94.00       4.65
 2457.000000         88.62           ---         150.0       V          104.0          3.0        114.00      25.38
 2457.000000           ---          88.10        150.0       V          104.0          3.0         94.00       5.90
                                            Restricted Bands Emissions Test
 2390.000000         51.29           ---         100.0       H           54.0          2.8         74.00      22.71
 2390.000000           ---          41.84        100.0       H           54.0          2.8         54.00      12.16
 2483.500000         51.96           ---         150.0       H           0.0           3.0         74.00      22.04
 2483.500000           ---          42.02        150.0       H           0.0           3.0         54.00      11.98




FCC Part 15.249                                                                                        Page 17 of 19


Bay Area Compliance Laboratories Corp. (Kunshan)                           Report No.: RKSA190505001-00B

FCC §15.215(c) – 20 dB BANDWIDTH TESTING
Applicable Standard

Intentional radiators operating under the alternative provisions to the general emission limits, as contained
in §§ 15.217 through 15.257 and in Subpart E of this part, must be designed to ensure that the 20 dB
bandwidth of the emission, or whatever bandwidth may otherwise be specified in the specific rule section
under which the equipment operates, is contained within the frequency band designated in the rule section
under which the equipment is operated.


Test Procedure

1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT on the test table without connection to measurement instrument. Turn on the EUT.
   Then set it to any one convenient frequency within its operating range. Set a reference level on the
   measuring instrument equal to the highest peak value.
3. Measure the frequency difference of two frequencies that were attenuated 20 dB from the reference
   level. Record the frequency difference as the emission bandwidth.
4. Repeat above procedures until all frequencies measured were complete.


Test Data

Environmental Conditions

Temperature:                      24.4C
Relative Humidity:                 50%
ATM Pressure:                    101.3kPa

The testing was performed by Max Min on 2019-07-18.

Test Result: Compliant.




FCC Part 15.249                                                                               Page 18 of 19


Bay Area Compliance Laboratories Corp. (Kunshan)                                                     Report No.: RKSA190505001-00B

Test Mode: Transmitting

                                                              Frequency                                    20 dB Bandwidth
            Channel
                                                                (MHz)                                           (MHz)
                  1                                              2457                                            0.956


                                                 Channel Frequency: 2457MHz
                                                Delta 1 [T1]              RBW    30 kHz       RF Att      20 dB
                               Ref Lvl                        -0.16 dB    VBW   100 kHz
                                20.5 dBm              955.91182365 kHz    SWT   8.5 ms        Unit           dBm
                      20.5
                                10.5 dB Offset                                       1 [T1]          -22.23 dBm
                                                                                                                    A
                                                                                                2.45651603 GHz
                          10                                                         1 [T1]            -0.16 dB
                                                                                              955.91182365 kHz

                          0
                                D1 -1.85 dBm


                        -10
                               1MAX                                                                                1MA


                        -20                               1                      1
                                      D2 -21.85 dBm


                        -30



                        -40



                        -50



                        -60



                        -70



                      -79.5
                               Center 2.457 GHz                    300 kHz/                          Span 3 MHz

                      Date:             18.JUL.2019   15:15:09




                                                ***** END OF REPORT *****




FCC Part 15.249                                                                                                          Page 19 of 19



Document Created: 2019-07-24 06:20:44
Document Modified: 2019-07-24 06:20:44

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC