Test report

FCC ID: 2ALV5-WP-100

Test Report

Download: PDF
FCCID_4083713

                                                   TEST REPORT
Report Reference No. .................... :               TRE1810022802                    R/C…….: 18984

FCC ID ............................................. :    2ALV5-WP-100

Applicant’s name ........................... :            Origins Technology Limited

Address ............................................. :   Laku Hutong #20. Dongcheng District, Beijing,China

Manufacturer.....................................:        Origins Technology Limited

Address.............................................:     Laku Hutong #20. Dongcheng District, Beijing,China

Test item description .................... :              Wellness Premier Recessed EQ Monitor

Trade Mark ....................................... :      Kaiterra

Model/Type reference ....................... :            WP-100

Listed Model(s) ................................. :       -

Standard ......................................... :      47 CFR FCC Part 15 Subpart B

Date of receipt of test sample………..:                      Oct.26,2018

Date of testing…………………………:                                Oct.26,2018 ~ Nov.19,2018

Date of issue…………………………...:                               Nov.19,2018

Result .................. …………………...:                     Pass

Compiled by
( position+printed name+signature) .. :                   File administrators Yueming Li
Supervised by
( position+printed name+signature) .. :                   Project Engineer Jerry Zhao
Approved by
( position+printed name+signature) .. :                   RF Manager Hans Hu


Testing Laboratory Name ............. :                   Shenzhen Huatongwei International Inspection Co., Ltd.

Address ............................................. :   1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao,
                                                          Gongming, Shenzhen, China

Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved.

This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen Huatongwei International Inspection Co., Ltd. is acknowledged as copyright owner and source of
the material. Shenzhen Huatongwei International Inspection Co., Ltd. takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.

The test report merely corresponds to the test sample.




                                                                 Page: 1 of 16


Report No : TRE1810022802                                                Page 2 of 16                                                          Issued: 2018-11-19




                                                                         Contents

1.       TEST STANDARDS AND REPORT VERSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1.1.    Test Standards                                                                                                                                                    3
1.2.    Report version information                                                                                                                                        3

2.       TEST DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4



3.       SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3.1.    Client Information                                                                                                                                                5
3.2.    Product Description                                                                                                                                               5
3.3.    EUT operation mode                                                                                                                                                5
3.4.    Configuration of Tested System                                                                                                                                    5
3.5.    Support unit used in test configuration                                                                                                                           6

4.       TEST ENVIRONMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

4.1.    Address of the test laboratory                                                                                                                                    7
4.2.    Test Facility                                                                                                                                                     7
4.3.    Environmental conditions                                                                                                                                          8
4.4.    Statement of the measurement uncertainty                                                                                                                          8
4.5.    Equipments Used during the Test                                                                                                                                   9

5.       TEST CONDITIONS AND RESULTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 0

5.1.    Conducted Emissions Test                                                                                                                                          10
5.2.    Radiated Emissions Test                                                                                                                                           11

6.       TEST SETUP PHOTOS OF THE EUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 5



7.       EXTERNAL AND INTERNAL PHOTOS OF THE EUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 6




Shenzhen Huatongwei International Inspection Co., Ltd.                                                     Report Template Version: V01 (2018-01)


Report No : TRE1810022802                         Page 3 of 16                         Issued: 2018-11-19



1. TEST STANDARDS AND REPORT VERSION
1.1. Test Standards
The tests were performed according to following standards:
47 CFR FCC Part 15 Subpart B - Unintentional Radiators
ANSI C63.4: 2014 – American National Standard for Methods of Measurement of Radio-Noise Emissions from
Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40GHz


1.2. Report version information
      Revision No.                Date of issue                          Description
          N/A                      2018-11-19                              Original




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : TRE1810022802                       Page 4 of 16                               Issued: 2018-11-19



2. TEST DESCRIPTION
               Test Item                         Section in CFR 47                Result       Test Engineer
         Conducted Emissions                          15.107(a)                     N/A             N/A
          Radiated Emissions                          15.109(a)                    PASS         Michael Jie


Note: The measurement uncertainty is not included in the test result.




Shenzhen Huatongwei International Inspection Co., Ltd.                  Report Template Version: V01 (2018-01)


Report No : TRE1810022802                     Page 5 of 16                          Issued: 2018-11-19



3. SUMMARY
3.1. Client Information
Applicant:                    Origins Technology Limited

Address:                      Laku Hutong #20. Dongcheng District, Beijing,China

Manufacturer:                 Origins Technology Limited

Address:                      Laku Hutong #20. Dongcheng District, Beijing,China

3.2. Product Description
Name of EUT:                  Wellness Premier Recessed EQ Monitor

Trade Mark:                   Kaiterra

Model No.:                    WP-100
Listed Model(s)               -
Power supply:                 DC 12V
Adapter information:          -


3.3. EUT operation mode
Test mode                                                     Describe
Data exchange mode            Keep the EUT in data exchange with PC status.


3.4. Configuration of Tested System




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : TRE1810022802                     Page 6 of 16                         Issued: 2018-11-19


3.5. Support unit used in test configuration
                                                             FCC ID /
Item    Equipment      Manufacturer        Model No.                     Data Cable     Power Cord
                                                             FCC DoC
                                                                                        Unshielded
 1          PC             DELL         OptiPlex 3020 MT     FCC DoC         N/A
                                                                                          1.8m
                                                                                        Unshielded
 2        Monitor          DELL             E1912Hf          FCC DoC         N/A
                                                                                          1.8m
                                                                         Unshielded,
 3       Keyboard          DELL             SK8115           FCC DoC                        N/A
                                                                           1.5m
                                                                         Unshielded,
 4        Mouse            DELL             MS111-T          FCC DoC                        N/A
                                                                           1.5m
                                                                                        Unshielded
 5        Printer         EPSON               L101           FCC DoC         N/A
                                                                                          1.8m




Shenzhen Huatongwei International Inspection Co., Ltd.          Report Template Version: V01 (2018-01)


Report No : TRE1810022802                          Page 7 of 16                             Issued: 2018-11-19



4. TEST ENVIRONMENT
4.1. Address of the test laboratory
Laboratory: Shenzhen Huatongwei International Inspection Co., Ltd.
Address: 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China
Phone: 86-755-26748019 Fax: 86-755-26748089
4.2. Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

CNAS-Lab Code: L1225

Shenzhen Huatongwei International Inspection Co., Ltd. has been assessed and proved to be in compliance
with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025:
2005 General Requirements) for the Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No. 3902.01

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing.

FCC-Registration No.: 762235

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from
the FCC is maintained in our files. Registration 762235.

IC-Registration No.: 5377B-1

Two 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No. 5377B-1.

ACA

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory can also perform testing for the
Australian C-Tick mark as a result of our A2LA accreditation.




Shenzhen Huatongwei International Inspection Co., Ltd.                   Report Template Version: V01 (2018-01)


Report No : TRE1810022802                      Page 8 of 16                              Issued: 2018-11-19



4.3. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:                                         15~35°C
Relative Humidity:                                       30~60 %
Air Pressure:                                            950~1050mba



4.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to CISPR 16 - 4 „Specification for radio
disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty in EMC
Measurements“ and is documented in the Shenzhen Huatongwei International Inspection Co., Ltd quality
system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to
that tested may result in additional deviation. The manufacturer has the sole responsibility of continued
compliance of the device.

Hereafter the best measurement capability for Shenzhen Huatongwei laboratory is reported:

                                                                       Measurement
                Test                             Range                                     Notes
                                                                        Uncertainty
Radiated Emissions                         30~1000MHz                     4.28 dB           (1)
Radiated Emissions                           1~18GHz                      5.16 dB           (1)
Conducted Disturbance                      0.15~30MHz                     3.35 dB           (1)
(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=1.96.




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : TRE1810022802                        Page 9 of 16                              Issued: 2018-11-19



4.5. Equipments Used during the Test
Conducted Emissions
                                                                                     Last Cal.     Next Cal.
Item   Test Equipment            Manufacturer         Model No.        Serial No.
                                                                                     (mm-dd-yy)    (mm-dd-yy)
1      EMI Test Receiver         R&S                  ESCI             101247        10/27/2018    10/26/2019
2      Artificial Mains          SCHWARZBECK          NNLK 8121        573           10/27/2018    10/26/2019
3      Pulse Limiter             R&S                  ESH3-Z2          101488        10/27/2018    10/26/2019
4      RF Connection Cable       HUBER+SUHNER         EF400            N/A           11/14/2017    11/13/2019
5      Test Software             R&S                  ES-K1            N/A           N/A           N/A
       Temperature and
6                                MIAOXIN              TH10R            N/A           10/30/2018    10/29/2019
       Humidity Meter


Radiated Emissions(Below 1GHz)
                                                                                     Last Cal.     Next Cal.
Item   Test Equipment            Manufacturer         Model No.         Serial No.
                                                                                     (mm-dd-yy)    (mm-dd-yy)
1      Semi-Anechoic Chamber     Albatross projects   SAC-3m-02         C11121       09/30/2018    09/29/2021
2      EMI Test Receiver         R&S                  ESCI              100900       10/28/2018    10/27/2019
3      Loop Antenna              R&S                  HFH2-Z2           100020       04/02/2018    04/02/2021
4      Ultra-Broadband Antenna   SCHWARZBECK          VULB9163          546          04/05/2017    04/04/2020
5      RF Connection Cable       HUBER+SUHNER         N/A               N/A          09/28/2018    09/27/2019
6      RF Connection Cable       HUBER+SUHNER         SUCOFLEX104       501184/4     09/28/2018    09/27/2019
7      Test Software             R&S                  ES-K1             N/A          N/A           N/A
8      Turntable                 Maturo Germany       TT2.0-1T          N/A          N/A           N/A
9      Antenna Mast              Maturo Germany       TAM-4.0-P         N/A          N/A           N/A
       Temperature and
10                               KEJIAN               KJ03              N/A          10/30/2018    10/29/2019
       Humidity Meter


Radiated Emissions(Above 1GHz)
                                                                                     Last Cal.     Next Cal.
Item   Test Equipment            Manufacturer         Model No.         Serial No.
                                                                                     (mm-dd-yy)    (mm-dd-yy)
1      Anechoic Chamber          Albatross projects   SAC-3m-01         C11121       09/30/2018    09/29/2021
2      Horn Antenna              SCHWARZBECK          9120D             1011         03/27/2017    03/26/2020
3      Preamplifier              BONN                 BLWA0160-2M       1811887      11/14/2018    11/13/2019
4      Pre-amplifier             SCHWARZBECK          BBV 9743          9743-0022    10/17/2018    10/16/2019
5      Broadband Pre-amplifier   SCHWARZBECK          BBV 9718          9718-248     04/28/2018    04/27/2019
6      Spectrum Analyzer         R&S                  FSP40             100597       10/27/2018    10/26/2019
7      RF Connection Cable       HUBER+SUHNER         RE-7-FL           N/A          11/15/2018    11/14/2019
8      RF Connection Cable       HUBER+SUHNER         RE-7-FH           N/A          11/15/2018    11/14/2019
9      Test Software             Audix                E3                N/A          N/A           N/A
10     Turntable                 Maturo Germany       TT2.0-1T          N/A          N/A           N/A
11     Antenna Mast              Maturo Germany       CAM-4.0-P-12      N/A          N/A           N/A
       Temperature and
12                               MINGLE               YH101             N/A          10/30/2018    10/29/2019
       Humidity Meter




Shenzhen Huatongwei International Inspection Co., Ltd.               Report Template Version: V01 (2018-01)


Report No : TRE1810022802                      Page 10 of 16                            Issued: 2018-11-19



5. TEST CONDITIONS AND RESULTS
5.1. Conducted Emissions Test
LIMIT
FCC CFR Title 47 Part 15 Subpart B Section 15.107:
                                                                      Limit (dBuV)
          Frequency range (MHz)
                                                      Quasi-peak                        Average
                  0.15-0.5                             66 to 56*                        56 to 46*
                    0.5-5                                 56                               46
                    5-30                                  60                               50
* Decreases with the logarithm of the frequency.

TEST CONFIGURATION




TEST PROCEDURE
1. The EUT was setup according to ANSI C63.4:2014
2. The EUT was placed on a plat form of nominal size, 1 m by 1.5 m, raised 80 cm above the conducting
   ground plane. The vertical conducting plane was located 40 cm to the rear of the EUT. All other surfaces
   of EUT were at least 80 cm from any other grounded conducting surface.
3. The EUT and simulators are connected to the main power through a line impedance stabilization
   network (LISN). The LISN provides a 50ohm / 50uH coupling impedance for the measuring equipment.
4. The peripheral devices are also connected to the main power through a LISN. (Please refer to the block
   diagram of the test setup and photographs)
5. Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor,was
   individually connected through a LISN to the input power source.
6. The excess length of the power cord between the EUT and the LISN receptacle were folded back and
   forth at the center of the lead to form a bundle not exceeding 40 cm in length.
7. Conducted emissions were investigated over the frequency range from 0.15MHz to 30MHz using a
   receiver bandwidth of 9 kHz.
8. During the above scans, the emissions were maximized by cable manipulation.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


Report No : TRE1810022802                       Page 11 of 16                              Issued: 2018-11-19



5.2. Radiated Emissions Test
LIMIT

FCC CFR Title 47 Part 15 Subpart B Section 15.109
              Frequency                       Limit (dBuV/m @3m)                              Value
             30MHz-88MHz                                   40.00                           Quasi-peak
             88MHz-216MHz                                  43.50                           Quasi-peak
            216MHz-960MHz                                  46.00                           Quasi-peak
             960MHz-1GHz                                   54.00                           Quasi-peak
                                                           54.00                             Average
              Above 1GHz
                                                           74.00                              Peak

TEST CONFIGURATION

    30MHz ~ 1GHz




    Above 1GHz




TEST PROCEDURE

1.   The EUT was tested according to ANSI C63.4:2014.
2.   The EUT is placed on a turn table which is 0.8 meter above ground.
3.   The turn table is rotated 360 degrees to determine the position of the maximum emission level.
4.   The EUT waspositioned such that the distance from antenna to the EUT was 3 meters.
5.   The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. Thisis
     repeated for both horizontal and vertical polarization of the antenna.
6.   Use the following spectrum analyzer settings
     (1) Span shall wide enough to fully capture the emission being measured;
     (2) Below 1GHz,
          RBW=120KHz, VBW=300KHz, Sweep=auto, Detector function=peak, Trace=max hold;
          If the emission level of the EUT measured by the peak detectoris 3 dB lower than the applicable limit,
          the peak emission level will be reported. Otherwise, theemission measurement will be repeated using
          the quasi-peak detector and reported.
     (3) From 1GHz to 5th harmonic, RBW=1MHz, VBW=3MHz

Shenzhen Huatongwei International Inspection Co., Ltd.               Report Template Version: V01 (2018-01)


Report No : TRE1810022802                     Page 12 of 16                           Issued: 2018-11-19


TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable


Note: Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor




Shenzhen Huatongwei International Inspection Co., Ltd.            Report Template Version: V01 (2018-01)


   Level {BpVim]
 80

 70

 60

 50

 40
 30

 20




                                                           Frequency [Hz]
 x x xmEs      ci1811006056_rea


MEASUREMENT RESULT:                     "GM1811096056_red"
11/9/2018            4:139M
      Frequency          Level         Transd      Limit     Margin         Det.        Height      Azimuth      Polarization
               MHz       dBpV/m            dB    dBuV/m             as                       m             deg
  169. 680000            26.70          ~12.7       43.5         16.8       P            100 .0      179.00      HORIZONTAL
  175.500000             27.80          ~12.4       43.5         15.7       oP           100 .0      179.00      HORIZONTAL
  225.940000             35.10           —9.3       46.0         10.9        QP          100 .0       50.00      HORIZONTAL
  307.420000             36.70           —6.8       46.0          9.3       P            100 .0      220.00      HORTZONTAL
  315.180000             36.20           —6.5       46.0          9.8       oP           100 .0      220.00       HORIZONTAL
  957.320000             35.90            8.2       46.0         10.1       QP           300 . 0     106.00      HORIZONTAL


   so Level (dBuVim)
                                                                                                            ECC CLASS—B PK
   70

   60
                                                                                                            FCC CLASS—B AV
   50

   40

   30

   20

   10


        1000    1200             1500              2000                                                          5000    6000
                                                          Frequency (MHz)
Mark      Frequency           Reading    Antenna     Cable       Preamp            Level           Limit     Over       Remark
               MBZ            dBuv/m       dB         dB                          dBuv/m       dBuv/m        limit
   1    1334.39                35.0       26.1        4.9                     28.8                 74.0      ~45.2       Peak
   2    1721.00                34.3       25.2        5.8                     28.0                 74.0      —46.0       Peak
   3    2219.61                33.9       27.6        6.5                        30.4              74.0      ~43.6       Peak
   4    3131.00                38.2       28.8        7.6                        37.1              74.0      ~36.9       Peak
   5    3945.15                $7.5       29.7        8.7                        39.1              74.0      ~34.9       Peak
   6    4787.45                40.2       31.6        9.5                     45.5                 74.0      —28.5       Peak


  Level [4ByVim]
80

70

60

50

40

30

20

10                                            1                                            i
 0                                            1                                            .         .
                                         100M                        200M             300M         400M        500M 600M      800M    1G
                                                           Frequency [H2z]

x x xMES         GM1811096055zed


MEASUREMENT RESULT:                   "GM1811096055_red"
11/9/2018 4:109M
   Frequency   Level                Transd         Limit     Margin          Det.         Height         Azinuth      Polarization
         MHz  dBuV/m                    ds        dBuV/m         as                           cm             deg
  171.620000              27.30                     43.5         16.2         or           100.0          358 .00     VERTICAL
  175.500000              28 .20                    43.5         15.3        or            100.0            3.00      VERTICAL
  235.640000              31.00                     46.0         15.0         or           100.0           40.00      VERTICAL
  307.420000              32.90                     46.0         13.1         or           100.0          119.00      VERTICAL
  311.300000              34.80                     46.0         11.2         or           100.0           93.00      VERTICAL
  937.920000              36.70                     46.0          9.3        op            100.0          187.00      VERTICAL


          Level (dBuVim)
     80
                                                                                                                   ECC CLASS—B PK
     70

     60
                                                                                                                   FCC CLASS—B AV
     50

     40

     30

     20

     10


          1000     1200        1500                2000                                                                    5000      6000
                                                           Frequency (MHz)
Mark        Frequency      Reading     Antenna       Cable         Preamp            Level          Limit           Over          Remark
                 MBZ       dBuv/m        dB            dB           dB              dBuv/m         dBuv/m           limit
     1    2999.21            39.9       28.6           7.5         37.6            38.4             74.0           ~35.6           Peak
     20   3142.24            38.4       28.8           7           37.4            37.5             74.0           ~36.5           Peak
     3    3530.36            36.3       29.1           8.2         37.1            36.5                   .0       ~37.5           Peak
     4    3987.79            37.9       29.7           8.8         36.8            39.6             74.0           —34.4           Peak
     5    4796.04            38.2       31.6           9.5         35.7            43.6             74.0           —30.4           Peak
     6    5585.03            36.3       31.8          10.3         34.4            44.0             74.0           ~30.0           Peak


Report No : TRE1810022802                     Page 15 of 16                      Issued: 2018-11-19



6. TEST SETUP PHOTOS OF THE EUT
Radiated Emissions (30MHz-1GHz)




Radiated Emissions (Above 1GHz)




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : TRE1810022802                     Page 16 of 16                        Issued: 2018-11-19



7. EXTERNAL AND INTERNAL PHOTOS OF THE EUT
    Reference to the test report No.: TRE1810022801.



                                        --------End of Report--------




Shenzhen Huatongwei International Inspection Co., Ltd.          Report Template Version: V01 (2018-01)



Document Created: 2018-11-20 13:19:49
Document Modified: 2018-11-20 13:19:49

© 2024 FCC.report