User manual

FCC ID: 2ALV5-LE-202

Users Manual

Download: PDF
FCCID_4474101

 Laser Egg+ CO2 Smart Air Quality Monitor specification and working

                               instructions

Name: Laser Egg+ CO2 Smart Air Quality Monitor

Category: Air Quality Monitoring Equipment

Features:

     1. Accurately measuring and displaying Air Quality Index following
        the standard of either AQI-CN or AQI-US;
     2. Accurately measuring and displaying the particle counting of
        PM>0.3um and PM>2.5um;
     3. Accurately measuring and displaying the concentration of
        PM2.5 in ug/m³;
     4. Accurately measuring and displaying the air temperature and
        humidity in the current environment;
     5. Accurately measuring and displaying the CO2 concentration;
     6. Equipped with high sensibility gravity sensor for smart working
        mode switching without manual intervention;
     7. Equipped with smart Wi-Fi module for convenient internet
        connection, allowing Laser Egg+ CO2 Smart Air Quality Monitor
        to upload the sensor data to the cloud in real time;
     8. Working with iOS and Android app, allowing the users to
        acquire sensor data remotely and also to control the monitor;
     9. Unique online calibration technology, allowing to monitor the
        air quality in different regions more accurately;
     10. Unique HomeKit features, allowing smart control, remote
        monitoring and weather forecasts.

Suitable for: Home environments, outdoor environments,
environmental monitoring institutes, factories, vehicles, and also for
scientific and educational purposes, and labs.


 Environment: Homes, offices, hotels, restaurants, shops, etc.

 Specifications:

        Connection: Wi-Fi

        Integrated battery: Lithium battery
        Input voltage: DC-5 V
        Input current: 1 A
        Power: 2.5 W
        Range:

                   AQI: 1~500;

                   PM2.5 concentration: 1~999 ug/m³;

                   PM count: 0~65536;

                   Temperature: -20~60℃;

                   Humidity: 0~100%RH;

                   CO2 concentration: 400~5000ppm.

       Accuracy: ±8%

       Working current: 600 mA

       Display: 2.4inches, 256 colors

       Size: φ106*88mm

      Response time: 10~100ms

       Net weight: 220g

 Introduction:


   1. Hardware introduction

    The system structure of Laser Egg+ CO2 Smart Air Quality Monitor is
shown in below diagram. The air quality monitor consists of:


                       Emas)

                        0t     mnae   J meare o io

                       Lithhn ty
                        rems masir        soee us



   @ Sensor module — Sampling the environment data, including laser
PM2. 5 sensor, Temperature/bumidity sensor SHT3O, CO2 sensor Senseair—§8.
gravity sensor ADXL34S5.

   @ MCU controlling module — is responsible for all Laser Egg+ C0O2
Smart Air Quality Monitor controlling. MARVELLSSMW302 processor is used
as the MCU.   It is used for data format parsing, PM2.5 concentration
calibration, adjusting the working mode of the Laser Egg+ CO2 Smart Air
Quality Monitor based on the signals from the gravity sensor, and to switch
the displays in the system according to the manual intervention via the
buttons

   C) Display module — includes a LCD sereen and the UI buttons.       The
screen can display the PM2. 5 values in three modes, and also the battery
state including charging and discharging

   @ Communication module — Wi—Fi module. It is used for the remote
communication of Laser Egg+ C02 Smart Air Quality Monitor. It can upload
the data acquired by the multiple air sensors, and also receive the
commands sent by the user via app on smart phones

   (:)    Power module — including the lithium battery system,
         charge/discharge management chip. It is used for the power supply
         of the whole system




   2 . Sensor introduction:

    Laser Egg+ CO2 Smart Air Quality Monitor uses a particle sensor based
on laser seattering

    The sensor contains a laser generator and a photoelectric receiver
It can convert laser scattering caused by the particles to electrical
signals, which are calculated into particle counting and concentration
with algorithms


       Laser based particle sensor is considered to be more accurate among
all scattering particle sensors.
      CO2 sensor is based on non—dispersive infrared monitoring technology.
The S8 sensor by Senseair is considered to be a high—end sensor.

      3. System operations:

      Refer to the below chart for Laser Egg+ CO2 Smart Air Quality Monitor
opertations


 &
 n
 ©                                  ordinary terminal
  i                     prgy ompinccn :                 IE
 [6                     Ee| Citceviaton 1                e                                                     Cloud Server
 1     s                                                   m                                                   tm
 .     paset—] oomes, EOieRen
      Melobreiit        We                                 —* tm                                                     Baeo
 —             ;        cotecing       ieb              worsoines
 n
 t
 1



                       Terperature and                  Gravity sensor
                       bunidity sensor
                                                                                     Non—volatite
                                                                                      memory unit
                         PIZ.5 sensor          \
                                                        at—pit. AdL NCU                      virt
                          C02 sensor

                       Charze mnagenent          |                            |_[ Function controt
                        Lithium battery                                                button
                         pover supply                     s2o240 Lop
                             system



        Air detection                Air detection                                                  Air detection
           terminall                    terninal2                                                       terninalif
               wffi                          viifi             &          &          &

            router                        router

                                              Lmfim
                          Interne               |                   [                Interne

                                                    Cloud Server
                                             (database, protocol analysis
                                       .
                             Data reading        { Data reading
                                                          a                             ;
                                                                              pata reading
                              Calibration           Calibration                Calibration
                                                          7                                         1
              Android—APP              o o               Tos—arp            e e          Ohauztet


1.   Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries
according to the instructions.

2.   Adapter shall be installed near the equipment and shall be easily accessible.


3.   The operating temperature of the EUT can’t exceed 60℃ and shouldn’t be lower than


 -20℃.


4.   The plug considered as disconnect device of adapter.

5.   The device complies with RF specifications when the device used at 20cm form your
body

6.   The product shall only be connected to a USB interface of version USB2.0.

FCC Caution:

Any Changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.

FCC RF Radiation Exposure Statement:

1. This Transmitter must not be co-located or operating in conjunction with any other antenna
or transmitter.

2. This equipment complies with RF radiation exposure limits set forth for an uncontrolled
environment.

This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:


-- Reorient or relocate the receiving antenna.

-- Increase the separation between the equipment and receiver.

-- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.

-- Consult the dealer or an experienced radio/TV technician for help.




Company neme: Origins Techonlogy Limited


Company address: Laku Hutong #20. Dongcheng District,Beijing,China



Document Created: 2019-10-10 10:36:38