Test report

FCC ID: 2ALPH-E73

Test Report

Download: PDF
FCCID_3768076

                         Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                       Report No: CCISE180106501

         1        Cover Page
                                          FCC REPORT
                                                           (BLE)

Applicant:                             Chengdu Ebyte Electronic Technology Co., Ltd
                                       Innovation Center D347, 4# XI-XIN road, High-tech district(west),
Address of Applicant:
                                       Chengdu, Sichuan, China
Equipment Under Test (EUT)

    Product Name:                      Bluetooth

    Model No.:                         E73

    Trade mark:                        EBYTE

FCC ID:                                2ALPH-E73

Applicable standards:                  FCC CFR Title 47 Part 15 Subpart C Section 15.247

Date of sample receipt:                17 Jan., 2018

Date of Test:                          17 Jan., to 25 Jan., 2018

Date of report issued:                 26 Jan., 2018

Test Result:                           PASS *

*   In the configuration tested, the EUT complied with the standards specified above.




Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate
to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer
should ensure that all products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than
that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted
to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested
and such sample(s) are retained for 90 days only.


                                                                                 Report No: CCISE180106501


2      Version
      Version No.                        Date                                    Description
            00                      26 Jan, 2018                                   Original




    Tested by:                                                           Date:           26 Jan, 2018

                                        Test Engineer


    Reviewed by:                                                         Date:           26 Jan, 2018

                                      Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 2 of 39


                                                                                                                       Report No: CCISE180106501

3         Contents
                                                                                                                                                                         Page
1       COVER PAGE ....................................................................................................................................................... 1
2       VERSION ............................................................................................................................................................... 2
3       CONTENTS ........................................................................................................................................................... 3
4       TEST SUMMARY .................................................................................................................................................. 4
5       GENERAL INFORMATION .................................................................................................................................. 5
    5.1         CLIENT INFORMATION ............................................................................................................................................ 5
    5.2         GENERAL DESCRIPTION OF E.U.T........................................................................................................................ 5
    5.3         TEST ENVIRONMENT AND TEST MODE ................................................................................................................... 6
    5.4         DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 6
    5.5         MEASUREMENT UNCERTAINTY.............................................................................................................................. 6
    5.6         LABORATORY FACILITY.......................................................................................................................................... 6
    5.7         LABORATORY LOCATION ....................................................................................................................................... 7
    5.8         TEST INSTRUMENTS LIST ....................................................................................................................................... 7
6       TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1     ANTENNA REQUIREMENT: ...................................................................................................................................... 8
    6.2     CONDUCTED OUTPUT POWER ............................................................................................................................ 10
    6.3     OCCUPY BANDWIDTH .......................................................................................................................................... 14
    6.4     POWER SPECTRAL DENSITY ............................................................................................................................... 16
    6.5     BAND EDGE ......................................................................................................................................................... 18
       6.5.1 Conducted Emission Method...................................................................................................................... 18
       6.5.2 Radiated Emission Method ......................................................................................................................... 20
    6.6     SPURIOUS EMISSION ........................................................................................................................................... 25
       6.6.1 Conducted Emission Method...................................................................................................................... 25
       6.6.2 Radiated Emission Method ......................................................................................................................... 28
7       TEST SETUP PHOTO ........................................................................................................................................ 33
8       EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 34




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                             Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                      Page 3 of 39


                                                                                      Report No: CCISE180106501

 4      Test Summary
                       Test Items                                Section in CFR 47                  Result
                  Antenna requirement                             15.203/15.247 (c)                  Pass
         AC Power Line Conducted Emission                                 15.207                     Pass
            Conducted Peak Output Power                              15.247 (b)(3)                   Pass
                6dB Emission Bandwidth                               15.247 (a)(2)                   Pass
                 Power Spectral Density                                  15.247 (e)                  Pass
                       Band Edge                                         15.247(d)                   Pass
     Conducted and radiated Spurious Emission                       15.205/15.209                    Pass
     Remark:
     Pass: Meet the requirement. N/A: Not Applicable for Non-adaptive equipment.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 4 of 39


CCIS
5           General Information
5.1 Client Information
            Applicant:                      Chengdu Ebyte Electronic Technology Co., Ltd
            Address:                        Innovation Center D347, 4# XI—XIN road, High—tech district(west),
                                            Chengdu, Sichuan, China
            Manufacturer/Factory:           Chengdu Ebyte Electronic Technology Co., Ltd.
            Address:                        Innovation Center D347, 4# XI—XIN road, High—tech district(west),
                                            Chengdu, Sichuan, China


5.2 General Description of E.U.T.
            Product Name:                   Bluetooth
            Madel No.:                      E73
            Operation Frequency:            2402—2480 MHz
            Channel numbers:                40
            Channel separation:             2 MHz
            Modulation technology:          GFSK
            Data speed :                    1Mbps
            Antenna Type:                   PCB Antenna
            Antenna gain:                   2 cBi
            Power supply:                   DC 3.3V



    Operation Frequency each of channel
    Channel         Frequency        Channel        Frequency   Channel      Frequency      Channel     Frequency
        0              2402MHz         10           2422MHz        20        2442MHz          30        2462MHz
        1              2404MHz         11           2424MHz        21        2444MHz          31        2464MHz
        2              2406MHz         12           2426MHz        22        2446MHz          32        2466MHz
        3              2408MHz         13           2428MHz        23        2448MHz          33        2468MHz
        4              2410MHz         14           2430MHz        24        2450MHz          34        2470MHz
        5              2412MHz         15           2432MHz        25        2452MHz          35        2472MHz
        6              2414MHz         16           2434MHz        26        2454MHz          36        2474MHz
        7              2416MHz         17           2436MHz        27        2456MHz          37        2476MHz
        8              2418MHz         18           2438MHz        28        2458MHz          38        2478MHz
        9              2420MHz         19           2440MHz        29        2460MHz          39        2480MHz
    Note:
    In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the
    middle frequency, and the highest frequency of channel were selected to perform the test. Channel No. 0,
    19 & 39 were selected as Lowest, Middle and Highest channel.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1801065
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                  Page 5 of 39


                                                                              Report No: CCISE180106501

5.3 Test environment and test mode
 Operating Environment:
     Temperature:                      24.0 C
     Humidity:                         54 % RH
     Atmospheric Pressure:             1010 mbar
 Test mode:
     Transmitting mode                 Keep the EUT in continuous transmitting with modulation
 The sample was placed 0.8m (below 1GHz)/1.5m (above 1GHz) above the ground plane of 3m chamber.
 Measurements in both horizontal and vertical polarities were performed. During the test, each emission was
 maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3
 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting
 cables, rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertical
 polarizations. The emissions worst-case are shown in Test Results of the following pages. Duty cycle setting
 during the transmission is 100% with maximum power setting for all modulations.

5.4 Description of Support Units
     Manufacturer                 Description                   Model              S/N           FCC ID/DoC
        LENOVO                       Laptop                     SL510           2847A65              DoC

5.5 Measurement Uncertainty
                    Parameters                                            Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                    2.14 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                    4.24 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                   4.35 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                     4.44 dB (k=2)
       Radiated Emission (18GHz ~ 26.5GHz)                                   4.56 dB (k=2)

5.6 Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
        FCC - Registration No.: 727551
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
       (Federal Communications Commission). The Registration No. is 727551.
        IC - Registration No.: 10106A-1
       The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
       Registration No.: 10106A-1.
        CNAS - Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.
        A2LA - Registration No.: 4346.01
       This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
       17025:2005 General requirements for the competence of testing and calibration laboratories. The test
       scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 6 of 39


                                                                                   Report No: CCISE180106501

5.7 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bao’an District, Shenzhen, Guangdong, China
        Tel: +86-755-23118282, Fax: +86-755-23116366
        Email: info@ccis-cb.com, Website: http://www.ccis-cb.com

5.8 Test Instruments list
   Radiated Emission:
                                                                                         Cal. Date    Cal. Due date
     Test Equipment            Manufacturer            Model No.          Serial No.
                                                                                        (mm-dd-yy)     (mm-dd-yy)
         3m SAC                   SAEMC               9m*6m*6m              966         07-22-2017    07-21-2020
      Loop Antenna           SCHWARZBECK              FMZB1519B            00044        02-25-2017    02-24-2018
   BiConiLog Antenna         SCHWARZBECK               VULB9163             497         02-25-2017    02-24-2018
      Horn Antenna           SCHWARZBECK              BBHA9120D             916         02-25-2017    02-24-2018
    EMI Test Software             AUDIX                    E3             6.110919b        N/A            N/A
      Pre-amplifier                 HP                   8447D           2944A09358     02-25-2017    02-24-2018
      Pre-amplifier                 CD                 PAP-1G18            11804        02-25-2017    02-24-2018
   Spectrum analyzer         Rohde & Schwarz             FSP30             101454       02-25-2017    02-24-2018
    EMI Test Receiver        Rohde & Schwarz            ESRP7              101070       02-25-2017    02-24-2018
          Cable                   ZDECL             Z108-NJ-NJ-81         1608458       02-25-2017    02-24-2018
          Cable               MICRO-COAX              MFR64639            K10742-5      02-25-2017    02-24-2018
          Cable                  SUHNER             SUCOFLEX100          58193/4PE      02-25-2017    02-24-2018


 Conducted Emission:
                                                                                         Cal. Date    Cal. Due date
    Test Equipment             Manufacturer            Model No.          Serial No.
                                                                                        (mm-dd-yy)     (mm-dd-yy)
   EMI Test Receiver        Rohde & Schwarz              ESCI              101189       02-25-2017    02-24-2018
     Pulse Limiter          SCHWARZBECK              OSRAM 2306             9731        02-25-2017    02-24-2018
         LISN                    CHASE                 MN2050D              1447        02-25-2017    02-24-2018
         LISN               Rohde & Schwarz            ESH3-Z5           8438621/010    07-21-2017    07-20-2018
         Cable                     HP                   10503A              N/A         02-25-2017    02-24-2018
   EMI Test Software             AUDIX                     E3             6.110919b        N/A            N/A




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 7 of 39


                                                                          Report No: CCISE180106501

6      Test results and Measurement Data
6.1 Antenna requirement:
        Standard requirement:          FCC Part 15 C Section 15.203 /247(c)
        15.203 requirement:
        An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
        responsible party shall be used with the device. The use of a permanently attached antenna or of an
        antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
        so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
        electrical connector is prohibited.
        15.247(c) (1)(i) requirement:
        (i) Systems operating in the 2400-2483.5 MHz band that is used exclusively for fixed. Point-to-point
        operations may employ transmitting antennas with directional gain greater than 6dBi provided the
        maximum conducted output power of the intentional radiator is reduced by 1 dB for every 3 dB that the
        directional gain of the antenna exceeds 6dBi.
       E.U.T Antenna:
       The BLE antenna is an PCB antenna which cannot replace by end-user, the best-case gain of the
       antenna is 2 dBi.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                          Page 8 of 39


                                                                              Report No: CCISE180106501


6.2 Conducted Emission
       Test Requirement:                FCC Part 15 C Section 15.207
       Test Method:                     ANSI C63.10: 2013
       Test Frequency Range:            150 kHz to 30 MHz
       Class / Severity:                Class B                 Class B
       Receiver setup:                  RBW=9kHz, VBW=30kHz
       Limit:                                                                         Limit (dBuV)
                                        Frequency range (MHz)
                                                                        Quasi-peak                  Average
                                                0.15-0.5                  66 to 56*                 56 to 46*
                                                  0.5-5                      56                        46
                                                  5-30                       60                        50
                                        * Decreases with the logarithm of the frequency.
       Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                            line impedance stabilization network (L.I.S.N.), which provides a
                                            50ohm/50uH coupling impedance for the measuring equipment.
                                        2. The peripheral devices are also connected to the main power through
                                            a LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                            termination. (Please refer to the block diagram of the test setup and
                                            photographs).
                                        3. Both sides of A.C. line are checked for maximum conducted
                                            interference. In order to find the maximum emission, the relative
                                            positions of equipment and all of the interface cables must be changed
                                            according to ANSI C63.4: 2014 on conducted measurement.
       Test setup:




       Test Instruments:                Refer to section 5.8 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 9 of 39


                                                                            Report No: CCISE180106501

Measurement Data:
Test Phase: Neutral




Notes:
1. An initial pre-scan was performed on the live and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 10 of 39


                                                                             Report No: CCISE180106501

Test Phase: Line




Notes:
1. An initial pre-scan was performed on the live and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 11 of 39


                                                                                Report No: CCISE180106501

6.3 Conducted Output Power
        Test Requirement:                FCC Part 15 C Section 15.247 (b)(3)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           30dBm
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data:
                                Maximum Conducted Output Power
          Test CH                                                              Limit(dBm)              Result
                                           (dBm)
           Lowest                                 3.85
           Middle                                 3.85                           30.00                  Pass
          Highest                                 3.76




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 12 of 39


                                                                                                                                        Report No: CCISE180106501

Test plot as follows:
                                                                                          * RBW   3 MHz    Marker 1 [T1 ]
                                                                                          * VBW   10 MHz               3.85 dBm
                                          Ref    26.5 dBm         * Att   30 dB            SWT 2.5 ms           2.401900000 GHz

                                                Offset   6.5 dB

                                          20
                                                                                                                                  A


                                   1 PK   10
                                   MAXH                                               1
                                                                                                                                  LVL

                                          0



                                          -10



                                          -20



                                          -30                                                                                     3DB




                                          -40



                                          -50



                                          -60



                                          -70

                                          Center 2.402 GHz                        1 MHz/                            Span 10 MHz




                                  Date: 24.JAN.2018          17:12:39


                                                                          Lowest channel
                                                                                          * RBW   3 MHz    Marker 1 [T1 ]
                                                                                          * VBW   10 MHz               3.85 dBm
                                          Ref    26.5 dBm         * Att   30 dB            SWT 2.5 ms           2.439940000 GHz

                                                Offset   6.5 dB

                                          20
                                                                                                                                  A


                                   1 PK   10
                                   MAXH                                               1
                                                                                                                                  LVL

                                          0



                                          -10



                                          -20



                                          -30                                                                                     3DB




                                          -40



                                          -50



                                          -60



                                          -70

                                          Center 2.44 GHz                         1 MHz/                            Span 10 MHz




                                  Date: 24.JAN.2018          17:12:57


                                                                          Middle channel
                                                                                          * RBW   3 MHz    Marker 1 [T1 ]
                                                                                          * VBW   10 MHz               3.76 dBm
                                          Ref    26.5 dBm         * Att   30 dB            SWT 2.5 ms           2.479720000 GHz

                                                Offset   6.5 dB

                                          20
                                                                                                                                  A


                                   1 PK   10
                                   MAXH                                           1
                                                                                                                                  LVL

                                          0



                                          -10



                                          -20



                                          -30                                                                                     3DB




                                          -40



                                          -50



                                          -60



                                          -70

                                          Center 2.48 GHz                         1 MHz/                            Span 10 MHz




                                  Date: 24.JAN.2018          17:13:15


                                                                          Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                                   Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                  Page 13 of 39


                                                                                Report No: CCISE180106501

6.4 Occupy Bandwidth
        Test Requirement:                FCC Part 15 C Section 15.247 (a)(2)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           >500kHz
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data:
         Test CH               6dB Emission Bandwidth (MHz)                 Limit(kHz)            Result
          Lowest                              0.876
          Middle                              0.876                           >500                 Pass
         Highest                              0.882

         Test CH               99% Occupy Bandwidth (MHz)                   Limit(kHz)            Result
          Lowest                              1.884
          Middle                              1.824                            N/A                  N/A
         Highest                              1.812




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 14 of 39


CCIS                                                                                        Report No: CCISE180106501

Test plot as follows:
                                  6dB EBW                                                         99% OBW
   &
  BA




   orte: e rmczoie   rsceecss                                     ortes se omm zore. rscsscze

                                Lowest channel                                                  Lowest channel

   @ nrore ce                                                     ® se    rex en




   orte: se amczoie rscsoces                                      ortec se omm zore. rscsecse

                                Middle channel                                                  Middle channel




   orte: renczoie rscsear                                         ortes e rmizore rsorcer

                                Highest channel                                                 Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                             Project No.: CCISE1801065
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                            Page 15 of 39


                                                                               Report No: CCISE180106501

6.5 Power Spectral Density
        Test Requirement:                FCC Part 15 C Section 15.247 (e)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           8 dBm
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data:
           Test CH                 Power Spectral Density (dBm)             Limit(dBm)             Result
            Lowest                                3.54
            Middle                                3.54                        8.00                 Pass
           Highest                                3.48




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 16 of 39


CCIS                                                                            Report No: CCISE180106501

Test plots as follow:




                                  ortes se omm zes resomcce

                                                              Lowest channel




                                  ortes se omm zes resorcse

                                                              Middle channel




                                  ortec 2s omm zue reconccr

                                                              Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1801065
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                          Page 17 of 39


                                                                               Report No: CCISE180106501

6.6 Band Edge
6.6.1 Conducted Emission Method
        Test Requirement:                FCC Part 15 C Section 15.247 (d)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           In any 100 kHz bandwidth outside the frequency band in which the
                                         spread spectrum intentional radiator is operating, the radio frequency
                                         power that is produced by the intentional radiator shall be at least 20 dB
                                         below that in the 100 kHz bandwidth within the band that contains the
                                         highest level of the desired power, based on either an RF conducted or a
                                         radiated measurement.
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 18 of 39


CCIS                                                                                       Report No: CCISE180106501

Test plots as follow:
                                                               «maw 100 kiz   mavker i) (ri o
                                                               «vam 200 knz              ~34.73 dan
                         mee 26.5 dan         «ate    20 ce     sur 225 ne         2.289081000 onz




                         ~r0.
                         starc 2.30 ons                       poe                   stop 2.¢03 onz




                    Date: 24.JAN.2018      14:11:53

                                                          Lowest channel




                    @                                          «haw 100 kiz   marken i (ri o
                                                               «vam 200 knz             —arcie cam
                         mee 26.5 dan         «ate    20 ce     sur 225 ne         2.486¢02000 onz




                         ~r0
                         suare 2.078 ons                  2.2 mie,                    stop 2.s on




                    Date: 24.JAN.2018      14:10:16

                                                         Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                          Project No.: CCISE1801065
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                         Page 19 of 39


                                                                               Report No: CCISE180106501

6.6.2     Radiated Emission Method
        Test Requirement:                FCC Part 15 C Section 15.209 and 15.205
        Test Method:                     ANSI C63.10: 2013 and KDB558074
        Test Frequency Range:            2.3GHz to 2.5GHz
        Test Distance:                   3m
        Receiver setup:                   Frequency         Detector         RBW           VBW          Remark
                                                             Peak            1MHz          3MHz        Peak Value
                                         Above 1GHz
                                                             RMS             1MHz          3MHz      Average Value
        Limit:                                 Frequency             Limit (dBuV/m @3m)              Remark
                                                                             54.00               Average Value
                                              Above 1GHz
                                                                             74.00                 Peak Value
        Test Procedure:                  1. The EUT was placed on the top of a rotating table 1.5 meters above
                                             the ground at a 3 meter camber. The table was rotated 360 degrees
                                             to determine the position of the highest radiation.
                                         2. The EUT was set 3 meters away from the interference-receiving
                                             antenna, which was mounted on the top of a variable-height antenna
                                             tower.
                                         3. The antenna height is varied from one meter to four meters above
                                             the ground to determine the maximum value of the field strength.
                                             Both horizontal and vertical polarizations of the antenna are set to
                                             make the measurement.
                                         4. For each suspected emission, the EUT was arranged to its worst
                                             case and then the antenna was tuned to heights from 1 meter to 4
                                             meters and the rota table was turned from 0 degrees to 360 degrees
                                             to find the maximum reading.
                                         5. The test-receiver system was set to Peak Detect Function and
                                             Specified Bandwidth with Maximum Hold Mode.
                                         6. If the emission level of the EUT in peak mode was 10 dB lower than
                                             the limit specified, then testing could be stopped and the peak values
                                             of the EUT would be reported. Otherwise the emissions that did not
                                             have 10 dB margin would be re-tested one by one using peak, quasi-
                                             peak or average method as specified and then reported in a data
                                             sheet.
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 20 of 39


                                                                         Report No: CCISE180106501


 Test channel: Lowest
 Horizontal:




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 21 of 39


                                                                         Report No: CCISE180106501


 Vertical:




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 22 of 39


                                                                         Report No: CCISE180106501


Test channel: Highest
Horizontal:




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 23 of 39


                                                                         Report No: CCISE180106501


Vertical:




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 24 of 39


                                                                               Report No: CCISE180106501

6.7     Spurious Emission
6.7.1     Conducted Emission Method
        Test Requirement:                FCC Part 15 C Section 15.247 (d)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           In any 100 kHz bandwidth outside the frequency band in which the
                                         spread spectrum intentional radiator is operating, the radio frequency
                                         power that is produced by the intentional radiator shall be at least 20 dB
                                         below that in the 100 kHz bandwidth within the band that contains the
                                         highest level of the desired power, based on either an RF conducted or a
                                         radiated measurement.
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 25 of 39


CCIS                                                                                         Report No: CCISE180106501

Test plot as follows:
                                                       Lowest channel
                      @                                      «haw oo kwk   meske x   ons o




                           Bcace 30 mee                res? aney                     ecop s on



                      Date: 24.JMN.2018     14:14:24

                                                       S0OMHz~25GHz



                                                       Middle channel
                      @_                                     «haw yoo se   meswes uons




                                                       rles> aner                    ecop s on



                      Date: 24. JIMM.2018   14:15:48

                                                       S0OMHz~25GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1801065
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                       Page 26 of 39


CCIS                                                                     Report No: CCISE180106501


                                                      Highest channel
                      @_                                    «naw 1oo w




                                                      rles> aner



                      Date: 24. JMM.2018   14:17:08

                                                      S0OMHz~25GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.: CCISE1801065
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 27 of 39


                                                                                Report No: CCISE180106501

 6.7.2 Radiated Emission Method
        Test Requirement:                FCC Part 15 C Section 15.209 and 15.205
        Test Method:                     ANSI C63.10:2013
        Test Frequency Range:            9kHz to 25GHz
        Test Distance:                   3m
        Receiver setup:                    Frequency       Detector         RBW        VBW             Remark
                                          30MHz-1GHz      Quasi-peak      120KHz     300KHz       Quasi-peak Value
                                                            Peak           1MHz        3MHz           Peak Value
                                          Above 1GHz
                                                            RMS            1MHz        3MHz         Average Value
        Limit:                                  Frequency           Limit (dBuV/m @3m)              Remark
                                              30MHz-88MHz                    40.0               Quasi-peak Value
                                             88MHz-216MHz                    43.5               Quasi-peak Value
                                            216MHz-960MHz                    46.0               Quasi-peak Value
                                              960MHz-1GHz                    54.0               Quasi-peak Value
                                                                             54.0                Average Value
                                               Above 1GHz
                                                                             74.0                 Peak Value
        Test Procedure:                  1.   The EUT was placed on the top of a rotating table 0.8m(below
                                              1GHz)/1.5m(above 1GHz) above the ground at a 3 meter camber.
                                              The table was rotated 360 degrees to determine the position of the
                                              highest radiation.
                                         2.   The EUT was set 3 meters away from the interference-receiving
                                              antenna, which was mounted on the top of a variable-height antenna
                                              tower.
                                         3.   The antenna height is varied from one meter to four meters above
                                              the ground to determine the maximum value of the field strength.
                                              Both horizontal and vertical polarizations of the antenna are set to
                                              make the measurement.
                                         4.   For each suspected emission, the EUT was arranged to its worst
                                              case and then the antenna was tuned to heights from 1 meter to 4
                                              meters and the rota table was turned from 0 degrees to 360 degrees
                                              to find the maximum reading.
                                         5.   The test-receiver system was set to Peak Detect Function and
                                              Specified Bandwidth with Maximum Hold Mode.
                                         6.   If the emission level of the EUT in peak mode was 10 dB lower than
                                              the limit specified, then testing could be stopped and the peak values
                                              of the EUT would be reported. Otherwise the emissions that did not
                                              have 10 dB margin would be re-tested one by one using peak, quasi-
                                              peak or average method as specified and then reported in a data
                                              sheet.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 28 of 39


                                                                            Report No: CCISE180106501

        Test setup:                      Below 1GHz




                                         Above 1GHz




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed
        Remark:                          1. Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and
                                            found the Y-axis is the worst case.
                                         2. 9 kHz to 30MHz is too low, so only shows the data of above 30MHz
                                            in this report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                         Page 29 of 39


                                                                         Report No: CCISE180106501


Below 1GHz:
Horizontal:




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 30 of 39


                                                                         Report No: CCISE180106501


Vertical:




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                    Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                   Page 31 of 39


                                                                                    Report No: CCISE180106501

Above 1GHz
              Test channel:                           Lowest                      Level:                          Peak
                   Read         Antenna       Cable       Preamp                                         Over
  Frequency                                                                Level      Limit Line
                   Level         Factor       Loss         Factor                                        Limit     Polarization
    (MHz)                                                                (dBuV/m)     (dBuV/m)
                  (dBuV)         (dB/m)        (dB)         (dB)                                         (dB)
   4804.00         50.50         30.85         6.80        41.81          46.34            74.00         -27.66      Vertical
   4804.00         51.57         30.85         6.80        41.81          47.41            74.00         -26.59     Horizontal
              Test channel:                           Lowest                      Level:                         Average
                   Read         Antenna       Cable       Preamp                                         Over
  Frequency                                                                Level      Limit Line
                   Level         Factor       Loss         Factor                                        Limit     Polarization
    (MHz)                                                                (dBuV/m)     (dBuV/m)
                  (dBuV)         (dB/m)        (dB)         (dB)                                         (dB)
   4804.00         43.58         30.85         6.80        41.81          39.42            54.00         -14.58      Vertical
   4804.00         44.17         30.85         6.80        41.81          40.01            54.00         -13.99     Horizontal



              Test channel:                           Middle                      Level:                          Peak
                   Read         Antenna       Cable       Preamp                                         Over
  Frequency                                                                Level      Limit Line
                   Level         Factor       Loss         Factor                                        Limit     Polarization
    (MHz)                                                                (dBuV/m)     (dBuV/m)
                  (dBuV)         (dB/m)        (dB)         (dB)                                         (dB)
   4884.00         52.44         31.20         6.86        41.84          48.66            74.00         -25.34      Vertical
   4884.00         51.99         31.20         6.86        41.84          48.21            74.00         -25.79     Horizontal
              Test channel:                           Middle                      Level:                         Average
                   Read         Antenna       Cable       Preamp                                         Over
  Frequency                                                                Level      Limit Line
                   Level         Factor       Loss         Factor                                        Limit     Polarization
    (MHz)                                                                (dBuV/m)     (dBuV/m)
                  (dBuV)         (dB/m)        (dB)         (dB)                                         (dB)
   4884.00         45.05         31.20         6.86        41.84          41.27            54.00         -12.73      Vertical
   4884.00         45.23         31.20         6.86        41.84          41.45            54.00         -12.55     Horizontal



              Test channel:                           Highest                     Level:                          Peak
                   Read         Antenna       Cable       Preamp                                         Over
  Frequency                                                                Level      Limit Line
                   Level         Factor       Loss         Factor                                        Limit     Polarization
    (MHz)                                                                (dBuV/m)     (dBuV/m)
                  (dBuV)         (dB/m)        (dB)         (dB)                                         (dB)
   4960.00         52.93         31.63         6.91        41.87          49.60            74.00         -24.40      Vertical
   4960.00         53.18         31.63         6.91        41.87          49.85            74.00         -24.15     Horizontal
              Test channel:                           Highest                     Level:                         Average
                   Read         Antenna       Cable       Preamp                                         Over
  Frequency                                                                Level      Limit Line
                   Level         Factor       Loss         Factor                                        Limit     Polarization
    (MHz)                                                                (dBuV/m)     (dBuV/m)
                  (dBuV)         (dB/m)        (dB)         (dB)                                         (dB)
   4960.00         45.67         31.63         6.91        41.87          42.34            54.00         -11.66      Vertical
   4960.00         46.11         31.63         6.91        41.87          42.78            54.00         -11.22     Horizontal

Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                       Project No.: CCISE1801065
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                         Page 32 of 39



Document Created: 2018-02-28 15:25:18