E70(915T30S)-User Manual-V1.0                                                                         Website:      www.cdebyte.com/en




                                    E70(915T30S)-User Manual-V1.0

Contents
1. Introduction.............................................................................................................................2
   1.1 Feature.............................................................................................................................. 2
   1.2. Electrical Parameter.........................................................................................................4
2. UART functional description (default)...................................................................................5
   2.1 Fixed transmission............................................................................................................ 5
   2.2 Broadcast transmission..................................................................................................... 5
   2.3 Broadcast address............................................................................................................. 5
   2.4 Monitoring address........................................................................................................... 5
3. Functional description............................................................................................................ 6
   3.2 Connect to MCU...............................................................................................................8
   3.3 Reset................................................................................................................................. 9
   3.4 AUX description...............................................................................................................9
4.Choose antenna......................................................................................................................10

5. About us................................................................................................................................11




Page 1 of 11                                                                        Technical Support : support@cdebyte.com


E70(915T30S)-User Manual-V1.0                                              Website:   www.cdebyte.com/en




1. Introduction

1.1 Feature




    E70(915T30S) is wireless UART transceiver module based on the original CC1310 of TI, operating at


907~922.5MHz (Default: 915MHz), TTL level and 3.3V IO port.




    The module has the function of data encryption & compression. The data of the module transmitted over


the features randomness. With the rigorous encryption & decryption, data interception becomes pointless.


The function of data compression decreases the transmission time & probability of being interfered, while


improving the reliability & transmission efficiency.




Page 2 of 11                                                  Technical Support : support@cdebyte.com


E70(915T30S)-User Manual-V1.0                                                 Website:   www.cdebyte.com/en



 No.                 Usage                                         Description
                                     In this mode, the data transmitting length is unlimited:
  1       Continuous transmission    Perfectly realize continuous transmission for the highest baud rate
                                     of 115200bps.
                                     Air data rate, FEC and Encryption are configurable by users;
  2      Fixed-length transmission   Transmitting data to the receiver in present air data rate with a most
                                     effective way to realize low delay and high respond.
                                     The receiving current is 14mA, and the stand by current is 4uA.
  3       Consumption advantage
                                     Battery-powered application is available.
                                     Ultra-low power consumption, suitable for the battery-powered
                                     application. When the module is on the power-saving mode, the
  4                  WOR
                                     receiving response delay time of module can adjust the power
                                     consumption.
                                     Module can communicate with other modules which are work in
                                     different channels and addresses, it is easy for networking and
                                     repeater.
  5            Fixed transmission    For example: module A transmits AA BB CC to module B (address:
                                     0x00 01, channel: 0x80), HEX format is 00 01 80 AA BB CC (00 01
                                     refers to the address of module B, 80 refers to the channel of
                                     module B), then module B receives AA BB CC (only module B).
                                     Set the module address as 0xFFFF, then the module can
  6        Broadcast transmission
                                     communicate with other modules in same channel.
                                     It has the feature of FEC (Forward Error Correction)algorithm,with
                                     high coding efficiency & good correction performance. In a sudden
  7                   FEC            interference, it can correct the interfered data packets proactively, so
                                     that the reliability & transmission range are improved proactively.
                                     Without FEC, those data packets can only be dropped.
                                     The parameter will be saved after users set the parameters and it
  8             Parameter saving     won’t be lost if powered-off. After module powered-on again, the
                                     module will work as previous settings.
                                     24 * 38.5mm, suitable for some application which has strict
  9             Ultra-small size
                                     limitation for the size.
  10      Secondary development      All IO port lead out already for secondary development.
                                     If   the    existing   UART   module     cannot     meet   customers’
                                     requirements, Ebyte accept customization of appropriate firmware.
  11           Customized Service
                                     Ebyte has provided customized wireless modules to tens of
                                     well-known enterprises. Please contact us for more details.
                                     CC1310 has different size and packing, in which main difference is
  12            Complete series      the number of GPIO. Ebyte has completely developed CC1310,
                                     including different size, frequency, power etc.




Page 3 of 11                                                    Technical Support : support@cdebyte.com


E70(915T30S)-User Manual-V1.0                                                 Website:   www.cdebyte.com/en




1.2. Electrical Parameter

  No.          Parameter item   Parameter details                         Description
    1               Size          24 * 38.5mm       -

    2             Weight              4.9g          Average weight

    3      Frequency Band       Default: 915MHz     Frequency range: 907~922.5MHz, channel: 32

    4               PCB              4-layer        Impedance-matching, lead-free and SMT

    5            Connector      1.27mm spacing      SMD

                                                    5V is recommended
    6          Supply voltage    2.6 ~ 5.5V DC
                                                    (Note: the voltage higher than 5.5V is forbidden)
           Communication
    7                            Maximum 3.8V       3.3V is recommended
                    level
                                                    Test condition: clear and open area& 30dBm, antenna
    8      Operation Range           6000m
                                                    gain: 2dBi,height: 2m,air data rate: 2.5kbps

                Transmitting
    9                                30dBm          Four optional level: 30, 27, 24, 17dBm
                   power

   10           Air data rate       2.5kbps         Six optional level: 2.5, 5, 12, 28, 64, 168kbps


   11      Standby current           4.0uA          Mode 3 (M0=1, M1=1, M2=1)

                Transmitting                        ≥1A (recommended)
   12                           602mA@30dBm
                  current                           (the voltage supply is 5V)

   13      Receiving current         14mA           Mode 0, Mode 1, Mode 2 (5v power supply)

           Communication                            8N, 8E1, 8O1, eight kinds of UART baud rate, from
   14                                UART
                  interface                         1200 to 115200 bps (default: 9600)

   15          Driving mode          UART           Can be configured to push-pull/high pull, open-drain.

                Transmitting
   16                           Depends on mode     Please refer to the transmission mode
                   length

   17      Receiving length     Depends on mode     Please refer to the transmission mode

   18             Address            65536          Easy for networking, broadcast and fixed transmission
                                                    The minimum average power consumption is about
   19              WOR              Available
                                                    30uA (it fits for battery-powered applications)
   20               RSSI            Available       It supports RSSI, refer to contents as follow

   21          Antenna type     IPEX/Stamp hole     50Ω characteristic impedance

                 Operating
   22                             -40 ~ +85℃        -
                temperature
                 Operating
   23                              10% ~ 90%        Relative humidity, no condensation
                  humidity
                  Storage
   24                             -40 ~ +125℃       -
                temperature

   25            Sensitivity    -110dBm@50kbps      Sensitivity has nothing to do with baud rate or timing




Page 4 of 11                                                    Technical Support : support@cdebyte.com


E70(915T30S)-User Manual-V1.0                                                  Website:   www.cdebyte.com/en




2. UART functional description (default)
2.1 Fixed transmission
                                          Hex                             Description
 The format: :Hexadecimal, such as:00 03 04 AA BB CC
 00 03 is the address of receiving module;04 is the channel ;AA BB CC is the transmission data。
 Transmitting module A            Hexadecimal     Address:00 01;Channel :02

 Receiving module B               Hexadecimal     Address:00 03;Channel :04

 Receiving module C               Hexadecimal     Address:00 05;Channel :04
 Receiving module D               Hexadecimal     Address:00 07;Channel :06
 Module A must be in fixed mode.
 Module A Transmitting data       Hexadecimal     00 03 04 AA BB CC
 Module B receiving data          Hexadecimal     AA BB CC
 Module C receiving data          Hexadecimal     No
 Module D receiving data          Hexadecimal     No
 Only the modules with matched address and channel can receive the data.
 In fixed transmission, modules only support 1 packet length (pls refer to electrical parameters). If the data
 packets exceed, then it needs to be subcontracted automatically.


2.2 Broadcast transmission
                                          Hex                             Description
 The format: Hexadecimal, such as:FF FF 04 AA BB CC
 FF FF is the address;04 is the channel of receiving module;AA BB CC is the transmission data。
 Transmitting module A            Hexadecimal     Address:00 01;Channel :02
 Receiving module B               Hexadecimal     Address:00 03;Channel :04
 Receiving module C               Hexadecimal     Address:00 05;Channel :04
 Receiving module D               Hexadecimal     Address:00 07;Channel :06
 Module A must be in fixed mode.
 Module A Transmitting data       Hexadecimal     FF FF 04 AA BB CC
 Module B receiving data          Hexadecimal     AA BB CC
 Module C receiving data          Hexadecimal     AA BB CC
 Module D receiving data          Hexadecimal     No
 All the module with this channel can receive the data.
 In fixed transmission, modules only support 1 packet length (pls refer to electrical parameters). If the data
 packets exceed, then it need to be subcontracted automatically.


2.3 Broadcast address
 1. For example, set the address of module A as 0xFF FF, and the channel as 0x04.
 2. When module A works as the transmitter (transparent transmission), all the receiving module with the
 channel 0x04 can receive the data, so as to realize the broadcast.


2.4 Monitoring address
 1. For example, set the address of module A as 0xFF FF, and the channel as 0x04.
 2.When module A works as the receiver, all the receiving module with the channel 0x04 can receive the
 data, so as to realize the monitoring.




Page 5 of 11                                                     Technical Support : support@cdebyte.com


E70(915T30S)-User Manual-V1.0                                                   Website:   www.cdebyte.com/en




3. Functional description

3.1 Pin Definition




     No.       Pin item         Pin direction                             Application

      1          GND              Ground        Ground electrode

      2          GND              Ground        Ground electrode

      3          GND              Ground        Ground electrode

      4          NC             Reserved pin    Reserved, to be floated

      5          NC             Reserved pin    Reserved, to be floated

      6          NC             Reserved pin    Reserved, to be floated

      7          NC             Reserved pin    Reserved, to be floated

      8          NC             Reserved pin    Reserved, to be floated
      9          NC             Reserved pin    Reserved, to be floated
     10          NC             Reserved pin    Reserved, to be floated

                                                Internal MCU controlled LNA pin, valid in high level,
     11        LNA_EN             Output
                                                connect to pin 44

                                                Internal MCU controlled PA pin, valid in high level, connect
     12         PA_EN             Output
                                                to pin 45

     13          NC             Reserved pin    Reserved, to be floated

     14          NC             Reserved pin    Reserved, to be floated

     15          NC             Reserved pin    Reserved, to be floated

                                                M2, M1, M0 jointly decide the 8 working modes; an
     16          M2                Input        external 1k protective resistor shall be connected in series
                                                when in use.

     17          GND              Ground        Ground electrode

                                                M2, M1, M0 jointly decide the 8 working modes;
     18          M0                Input
                                                An external 1k protective resistor shall be connected in




Page 6 of 11                                                    Technical Support : support@cdebyte.com


E70(915T30S)-User Manual-V1.0                                                  Website:   www.cdebyte.com/en




                                               series and a 1M pull-up resistor shall be added when in use.
                                               (Cannot be floated, it can be grounded when not used)

                                               M2, M1, M0 jointly decide the 8 working modes;
                                               An external 1k protective resistor shall be connected in
     19          M1                Input
                                               series and a 1M pull-up resistor shall be added when in use.
                                               (Cannot be floated, it can be grounded when not used)
                                               TTL serial port input connects to external TXD pin. It can be
                                               configured as open-drain or high pull input, please refer to
     20          RXD               Input
                                               Parameter setting. An external 1k protective resistor shall
                                               be connected in series when using.

                                               TTL serial port output connects to external RXD input pin. It
                                               can be configured as open-drain or push-pull input, please
     21          TXD              Output
                                               refer to Parameter setting. An external 1k protective
                                               resistor shall be connected in series when using.

     22          TCKC              Input       JTAG TCKC

     23         TMSC               Input       JTAG TMSC

     24         RESET              Input       Reset pin, valid in low level

     25          NC             Reserved pin   Reserved, to be floated

     26          NC             Reserved pin   Reserved, to be floated

                                               It is used to indicate the operation status of module, for
                                               user to wake up the external MCU, the module outputs low
                                               level during self-checking and initialization at power on, it
     27          AUX              Output       can be configured as open-drain output or pull-up output,
                                               please refer to parameter setting part, An external 1k
                                               protective resistor shall be connected in series when using.
                                               (can be floated)

                                               Power positive reference,
     28          VCC                 -
                                               Power supply 2.6V ~ 5.5V DC

                                               Power positive reference,
     29          VCC                 -
                                               Power supply 2.6V ~ 5.5V DC

     30          GND              Ground       Ground electrode

     31          GND              Ground       Ground electrode

     32          NC             Reserved pin   Reserved, to be floated

     33          NC             Reserved pin   Reserved, to be floated

     34          NC             Reserved pin   Reserved, to be floated


     35          NC             Reserved pin   Reserved, to be floated


     36          NC             Reserved pin   Reserved, to be floated


     37          NC             Reserved pin   Reserved, to be floated




Page 7 of 11                                                      Technical Support : support@cdebyte.com


E70(915T30S)-User Manual-V1.0                                                 Website:   www.cdebyte.com/en




     38             NC          Reserved pin   Reserved, to be floated


     39             NC          Reserved pin   Reserved, to be floated


     40             NC          Reserved pin   Reserved, to be floated


     41             NC          Reserved pin   Reserved, to be floated

     42             NC          Reserved pin   Reserved, to be floated


     43             NC          Reserved pin   Reserved, to be floated


     44            LNA_EN          Input       Internal LNA pin, valid in high level, connect to pin 11


     45            PA_EN           Input       Internal PA pin, valid in high level, connect to pin 12


     46             GND           Ground       Ground electrode


     47             GND           Ground       Ground electrode

     48             ANT              -         Antenna (50Ω characteristic impedance)


Real values of MCU controlled PA and LNA are as follows:


           No.                        PA_EN                    LNA_EN                        Notes


               1                           1                       0                In transmitting


               2                           0                       1                In receiving


               3                           0                       0                In sleeping mode



3.2 Connect to MCU




Page 8 of 11                                                    Technical Support : support@cdebyte.com


E70(915T30S)-User Manual-V1.0                                                   Website:   www.cdebyte.com/en




  No.                                         Description (STM8L MCU)



    1      The UART module is TTL level., please connect to the MCU of TTL level.


           For some MCU works at 5V DC, it may need to add 4 ~ 10K pull-up resistor for the TXD & AUX
    2
           pins.




 3.3 Reset


  No.                                                 Description




           When the module is powered on, AUX outputs low level immediately, conducting hardware
           self-check and setting the operating mode on the basis of the user parameters. During the
    1      process, the AUX keeps low level. After this process, the AUX outputs high level and starts to work
           as per the operation mode combined by M2, M1, M0. Therefore, the user needs to wait the AUX
           rising edge as the starting point of module’s normal work.




3.4 AUX description
It can indicate whether there are data that has been sent through wireless, or whether all wireless data have
been sent through UART, or whether the module is still in the process of self-check initialization.
  No.                                                 Description
           【Indication of UART output】
           It can be used to wake up external MCU(In continuous mode, the AUX indication isn't delayed.)




    1




Page 9 of 11                                                      Technical Support : support@cdebyte.com


E70(915T30S)-User Manual-V1.0                                                  Website:   www.cdebyte.com/en



          【Indication of wireless transmitting】
          1. Under subpackage transmission mode, the internal buffer size depends on the subpackage
          size, if the data packet length is 1024 bytes, the corresponding buffer is 1024 bytes, when the
          AUX=1, user could transmit data continuously ,no more than 1024 bytes .
          2. Under continuous transmission mode, AUX=1, there is no limitation on user data input
          length.
          3. Under WOR transmission mode, AUX=1, user could continuously input less than 84 bytes.
          4. AUX=1 means the serial port data has been transmitted completely.




    2




          【Configuration procedure of module】only when resetting and exiting sleep mode




    3




4. Choose antenna
The 0R resistance welding before factory is as below(left), the antenna type is stamp hole;
If users need to change the antenna type to IPEX, pls change the 0R resistance as below(right).




        Choose stamp hole                                                     choose IPEX




Page 10 of 11                                                     Technical Support : support@cdebyte.com


E70(915T30S)-User Manual-V1.0                                                  Website:   www.cdebyte.com/en




5. About us




Chengdu Ebyte Electronic Technology Co., Ltd. (Ebyte) is specialized in wireless solutions and products.

◆We research and develop various products with diversified firmware;
◆Our catalogue covers WiFi, Bluetooth, Zigbee, PKE, wireless data transceivers & etc.;
◆With about one hundred staffs, we have won tens of thousands customers and sold millions of products;
◆Our products are being applied in over 30 countries and regions globally;
◆We have obtained ISO9001 QMS and ISO14001 EMS certifications;
◆We have obtained various of patents and software copyrights, and have acquired FCC, CE, RoHs & etc.




Page 11 of 11                                                     Technical Support : support@cdebyte.com


FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment.
The modular can be installed or integrated in mobile or fix devices only. This modular cannot be
installed in any portable device .
FCC Radiation Exposure Statement
This modular complies with FCC RF radiation exposure limits set forth for an uncontrolled environment.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter. This modular must be installed and operated with a minimum distance of 20 cm between
the radiator and user body.
If the FCC identification number is not visible when the module is installed inside another device, then
the outside of the device into which the module is installed must also display a label referring to the
enclosed module. This exterior label can use wording such as the following: “Contains Transmitter
Module FCC ID: 2ALPH-E70 Or Contains FCC ID: 2ALPH-E70”
When the module is installed inside another device, the user manual of the host must contain below
warning statements;
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause undesired
operation.
2. Changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
The devices must be installed and used in strict accordance with the manufacturer's instructions as
described in the user documentation that comes with the product.



Document Created: 2018-06-01 14:24:37
Document Modified: 2018-06-01 14:24:37

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC