Test report

FCC ID: 2ALPH-E70

Test Report

Download: PDF
FCCID_3873354

                         Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                       Report No: CCISE180107301

         1        Cover Page
                                          FCC REPORT
                                                          (RFID)

Applicant:                             Chengdu Ebyte Electronic Technology Co., Ltd.
                                       Innovation Center D347, 4# XI-XIN road, High-tech district(west),
Address of Applicant:
                                       Chengdu, Sichuan, China
Equipment Under Test (EUT)

    Product Name:                      Wireless transceiver module

    Model No.:                         E70

    Trade mark:                        EBYTE

FCC ID:                                2ALPH-E70

Applicable standards:                  FCC CFR Title 47 Part 15 Subpart C Section 15.247

Date of sample receipt:                18 Jan., 2018

Date of Test:                          18 May., to 22 May., 2018

Date of report issued:                 23 May., 2018

Test Result:                           PASS *

*   In the configuration tested, the EUT complied with the standards specified above.




Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate
to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer
should ensure that all products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than
that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted
to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested
and such sample(s) are retained for 90 days only.


                                                                                 Report No: CCISE180107301


2      Version
      Version No.                        Date                                    Description
            00                     23 May., 2018                                   Original




    Tested by:                                                           Date:          23 May., 2018

                                        Test Engineer


    Reviewed by:                                                         Date:          23 May., 2018

                                      Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 2 of 38


                                                                                                                       Report No: CCISE180107301

3         Contents
                                                                                                                                                                         Page
1       COVER PAGE ....................................................................................................................................................... 1
2       VERSION ............................................................................................................................................................... 2
3       CONTENTS ........................................................................................................................................................... 3
4       TEST SUMMARY .................................................................................................................................................. 4
5       GENERAL INFORMATION .................................................................................................................................. 5
    5.1         CLIENT INFORMATION ............................................................................................................................................ 5
    5.2         GENERAL DESCRIPTION OF E.U.T........................................................................................................................ 5
    5.3         TEST ENVIRONMENT AND TEST MODE ................................................................................................................... 6
    5.4         DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 6
    5.5         MEASUREMENT UNCERTAINTY.............................................................................................................................. 6
    5.6         LABORATORY FACILITY.......................................................................................................................................... 6
    5.7         LABORATORY LOCATION ....................................................................................................................................... 7
    5.8         TEST INSTRUMENTS LIST ....................................................................................................................................... 7
6       TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1     ANTENNA REQUIREMENT: ...................................................................................................................................... 8
    6.2     CONDUCTED EMISSION ......................................................................................................................................... 9
    6.3     CONDUCTED OUTPUT POWER ............................................................................................................................ 12
    6.4     OCCUPY BANDWIDTH .......................................................................................................................................... 14
    6.5     POWER SPECTRAL DENSITY ............................................................................................................................... 16
    6.6     BAND EDGE ......................................................................................................................................................... 18
       6.6.1 Conducted Emission Method...................................................................................................................... 18
       6.6.2 Radiated Emission Method ......................................................................................................................... 20
    6.7     SPURIOUS EMISSION ........................................................................................................................................... 26
       6.7.1 Conducted Emission Method...................................................................................................................... 26
       6.7.2 Radiated Emission Method ......................................................................................................................... 28
7       TEST SETUP PHOTO ........................................................................................................................................ 35
8       EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 37




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                             Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                      Page 3 of 38


                                                                                      Report No: CCISE180107301

 4      Test Summary
                       Test Items                                Section in CFR 47                  Result
                  Antenna requirement                             15.203/15.247 (c)                  Pass
         AC Power Line Conducted Emission                                 15.207                     Pass
            Conducted Peak Output Power                              15.247 (b)(3)                   Pass
                6dB Emission Bandwidth                               15.247 (a)(2)                   Pass
                 Power Spectral Density                                  15.247 (e)                  Pass
                       Band Edge                                         15.247(d)                   Pass
     Conducted and radiated Spurious Emission                       15.205/15.209                    Pass
     Remark:
     Pass: Meet the requirement. N/A: Not Applicable for Non-adaptive equipment.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 4 of 38


                                                                               Report No: CCISE180107301

5      General Information
5.1 Client Information
        Applicant:                       Chengdu Ebyte Electronic Technology Co., Ltd.
        Address:                         Innovation Center D347,4# XI-XIN road, High-tech district(west),
                                         Chengdu, Sichuan, China
        Manufacturer/Factory:            Chengdu Ebyte Electronic Technology Co., Ltd.
        Address:                         Innovation Center D347,4# XI-XIN road, High-tech district(west),
                                         Chengdu, Sichuan, China

5.2 General Description of E.U.T.
        Product Name:                    Wireless transceiver module
        Model No.:                       E70
        Operation Frequency:             907-922.5 MHz
        Channel numbers:                 32
        Modulation technology:           FSK
        Antenna Type:                    External Antenna
        Antenna gain:                    2 dBi
        Power supply:                    DC 5V


    Operation Frequency each of channel for GFSK
         Channel               Frequency           Channel         Frequency     Channel         Frequency
             0                 907.0MHz               13            913.5MHz        26            920.0MHz
             1                 907.5MHz               14            914.0MHz        27            920.5MHz
             2                 908.0MHz               15            914.5MHz        28            921.0MHz
             3                 908.5MHz               16            915.0MHz        29            921.5MHz
             4                 909.0MHz               17            915.5MHz        30            922.0MHz
             5                 909.5MHz               18            916.0MHz        31            922.5MHz
             6                 910.0MHz               19            916.5MHz
             7                 910.5MHz               20            917.0MHz
             8                 911.0MHz               21            917.5MHz
             9                 911.5MHz               22            918.0MHz
             10                912.0MHz               23            918.5MHz
             11                912.5MHz               24            919.0MHz
             12                913.0MHz               25            919.5MHz
    Remark: Channel 0, 16 & 31 selected for GFSK.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 5 of 38


                                                                              Report No: CCISE180107301

5.3 Test environment and test mode
 Operating Environment:
     Temperature:                      24.0 C
     Humidity:                         54 % RH
     Atmospheric Pressure:             1010 mbar
 Test mode:
     Transmitting mode                 Keep the EUT in continuous transmitting with modulation       120VAC 60Hz

 The sample was placed 0.8m (below 1GHz)/1.5m (above 1GHz) above the ground plane of 3m chamber.
 Measurements in both horizontal and vertical polarities were performed. During the test, each emission was
 maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3
 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting
 cables, rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertical
 polarizations. The emissions worst-case are shown in Test Results of the following pages. Duty cycle setting
 during the transmission is 100% with maximum power setting for all modulations.

5.4 Description of Support Units
      Manufacturer                Description                 Model               S/N            FCC ID/DoC
       LENOVO                       Laptop                    SL510             2847A65             DoC
        EBYTE                      Test suite                 E25 D1              N/A               N/A
       Sunshiny                     Adapter               XS-1201000SCN           N/A               N/A

5.5 Measurement Uncertainty
                    Parameters                                            Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                    ±2.22 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                    ±2.76 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                   ±4.28 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                     ±5.72 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                    ±2.88 dB (k=2)

5.6 Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
        FCC - Registration No.: 727551
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
       (Federal Communications Commission). The Registration No. is 727551.
        IC - Registration No.: 10106A-1
       The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
       with Registration No.: 10106A-1.
        CNAS - Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.
        A2LA - Registration No.: 4346.01
       This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
       17025:2005 General requirements for the competence of testing and calibration laboratories. The test
       scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 6 of 38


                                                                                 Report No: CCISE180107301

5.7 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bao’an District, Shenzhen, Guangdong, China
        Tel: +86-755-23118282, Fax: +86-755-23116366
        Email: info@ccis-cb.com, Website: http://www.ccis-cb.com

5.8 Test Instruments list

 Radiated Emission:
                                                                                        Cal. Date    Cal. Due date
    Test Equipment             Manufacturer            Model No.          Serial No.
                                                                                       (mm-dd-yy)     (mm-dd-yy)
       3m SAC                   SAEMC                 9m*6m*6m               966       07-22-2017    07-21-2020
  BiConiLog Antenna         SCHWARZBECK               VULB9163               497       02-25-2018    02-24-2019
     Horn Antenna           SCHWARZBECK              BBHA9120D               916       02-25-2018    02-24-2019
  EMI Test Software             AUDIX                     E3              6.110919b        N/A            N/A
     Pre-amplifier                HP                    8447D            2944A09358    03-07-2018    03-06-2019
     Pre-amplifier                CD                  PAP-1G18              11804      03-07-2018    03-06-2019
  Spectrum analyzer         Rohde & Schwarz             FSP30               101454     03-07-2018    03-06-2019
  EMI Test Receiver         Rohde & Schwarz             ESRP7               101070     03-07-2018    03-06-2019
   Simulated Station            Anritsu                MT8820C           6201026545    03-07-2018    03-06-2019
        Cable                   ZDECL               Z108-NJ-NJ-81          1608458     03-07-2018    03-06-2019
        Cable                MICRO-COAX               MFR64639             K10742-5    03-07-2018    03-06-2019
        Cable                  SUHNER               SUCOFLEX100           58193/4PE    03-07-2018    03-06-2019

 Conducted Emission:
                                                                                        Cal. Date    Cal. Due date
    Test Equipment             Manufacturer            Model No.          Serial No.
                                                                                       (mm-dd-yy)     (mm-dd-yy)
   EMI Test Receiver        Rohde & Schwarz              ESCI               101189     03-07-2018    03-06-2019
     Pulse Limiter          SCHWARZBECK              OSRAM 2306              9731      03-07-2018    03-06-2019
         LISN                   CHASE                  MN2050D               1447      02-25-2018    02-24-2019
         LISN               Rohde & Schwarz            ESH3-Z5           8438621/010   07-21-2017    07-20-2018
          ISN                 Schwarzbeck             CAT3 8158           CCIS0185     02-25-2018    02-24-2019
          ISN                 Schwarzbeck             CAT5 8158           CCIS0186     02-25-2018    02-24-2019
          ISN                 Schwarzbeck             NTFM 8158           CCIS0187     02-25-2018    02-24-2019
        Cable                     HP                    10503A                N/A      03-07-2018    03-06-2019
   EMI Test Software            AUDIX                     E3              6.110919b        N/A            N/A




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 7 of 38


                                                                          Report No: CCISE180107301

6      Test results and Measurement Data
6.1 Antenna requirement:
        Standard requirement:          FCC Part 15 C Section 15.203 /247(c)
        15.203 requirement:
        An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
        responsible party shall be used with the device. The use of a permanently attached antenna or of an
        antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
        so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
        electrical connector is prohibited.
        15.247(c) (1)(i) requirement:
        (i) Systems operating in the 2400-2483.5 MHz band that is used exclusively for fixed. Point-to-point
        operations may employ transmitting antennas with directional gain greater than 6dBi provided the
        maximum conducted output power of the intentional radiator is reduced by 1 dB for every 3 dB that the
        directional gain of the antenna exceeds 6dBi.
       E.U.T Antenna:
       The BLE antenna is an External antenna which cannot replace by end-user, the best-case gain of the
       antenna is 2 dBi.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                          Page 8 of 38


                                                                              Report No: CCISE180107301


6.2 Conducted Emission
       Test Requirement:                FCC Part 15 C Section 15.207
       Test Method:                     ANSI C63.10: 2013
       Test Frequency Range:            150 kHz to 30 MHz
       Class / Severity:                Class B                 Class B
       Receiver setup:                  RBW=9kHz, VBW=30kHz
       Limit:                                                                         Limit (dBuV)
                                        Frequency range (MHz)
                                                                        Quasi-peak                  Average
                                                0.15-0.5                  66 to 56*                 56 to 46*
                                                  0.5-5                      56                        46
                                                  5-30                       60                        50
                                        * Decreases with the logarithm of the frequency.
       Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                            line impedance stabilization network (L.I.S.N.), which provides a
                                            50ohm/50uH coupling impedance for the measuring equipment.
                                        2. The peripheral devices are also connected to the main power through
                                            a LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                            termination. (Please refer to the block diagram of the test setup and
                                            photographs).
                                        3. Both sides of A.C. line are checked for maximum conducted
                                            interference. In order to find the maximum emission, the relative
                                            positions of equipment and all of the interface cables must be changed
                                            according to ANSI C63.4: 2014 on conducted measurement.
       Test setup:




       Test Instruments:                Refer to section 5.8 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 9 of 38


                                                                            Report No: CCISE180107301

Measurement Data:
Test Phase: Neutral




Notes:
1. An initial pre-scan was performed on the live and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 10 of 38


                                                                             Report No: CCISE180107301


Test Phase: Line




Notes:
1. An initial pre-scan was performed on the live and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 11 of 38


                                                                                Report No: CCISE180107301

6.3 Conducted Output Power
        Test Requirement:                FCC Part 15 C Section 15.247 (b)(3)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           30dBm
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data:
                                Maximum Conducted Output Power
          Test CH                                                              Limit(dBm)              Result
                                           (dBm)
           Lowest                                 15.88
           Middle                                 14.10                          30.00                  Pass
          Highest                                 12.82




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 12 of 38


                                                                                                                                        Report No: CCISE180107301

Test plot as follows:
                                                         * RBW   1 MHz   Marker 1 [T1 ]                                                                  * RBW   1 MHz   Marker 1 [T1 ]
                                                         * VBW   3 MHz              15.88 dBm                                                            * VBW   3 MHz              14.10 dBm
             Ref    36.5 dBm         * Att   40 dB        SWT 2.5 ms        906.830000000 MHz                Ref    36.5 dBm         * Att   40 dB        SWT 2.5 ms        914.790000000 MHz

                   Offset   6.5 dB                                                                                 Offset   6.5 dB

             30                                                                                              30
                                                                                                A                                                                                               A


      1 PK   20                                                                                       1 PK   20
                                                     1
      MAXH                                                                                            MAXH                                           1
                                                                                                LVL                                                                                             LVL

             10                                                                                              10



             0                                                                                               0



             -10                                                                                             -10



             -20                                                                                3DB          -20                                                                                3DB




             -30                                                                                             -30



             -40                                                                                             -40



             -50                                                                                             -50



             -60                                                                                             -60

             Center 907 MHz                      500 kHz/                          Span 5 MHz                Center 915 MHz                      500 kHz/                          Span 5 MHz




      Date: 22.MAY.2018         20:20:25                                                              Date: 22.MAY.2018         19:59:57




                                         Lowest channel                                                                                  Middle channel


                                                         * RBW   1 MHz   Marker 1 [T1 ]
                                                         * VBW   3 MHz              12.82 dBm
             Ref    36.5 dBm         * Att   40 dB        SWT 2.5 ms        922.280000000 MHz

                   Offset   6.5 dB

             30
                                                                                                A


      1 PK   20
      MAXH
                                                 1                                              LVL

             10



             0



             -10



             -20                                                                                3DB




             -30



             -40



             -50



             -60

             Center 922.5 MHz                    500 kHz/                          Span 5 MHz




      Date: 22.MAY.2018         20:30:09




                                        Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                                                         Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                                                       Page 13 of 38


                                                                                Report No: CCISE180107301

6.4 Occupy Bandwidth
        Test Requirement:                FCC Part 15 C Section 15.247 (a)(2)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           >500kHz
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data:
         Test CH               6dB Emission Bandwidth (MHz)                 Limit(kHz)            Result
          Lowest                              0.556
          Middle                              0.552                           >500                 Pass
         Highest                              0.556

         Test CH               99% Occupy Bandwidth (MHz)                   Limit(kHz)            Result
          Lowest                              0.580
          Middle                              0.576                            N/A                  N/A
         Highest                              0.580




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 14 of 38


CCIS                                                                                  Report No: CCISE180107301

Test plot as follows:
                                      6dB EBW                                                99% OBW

     ® m      sea m




     deses ro meecaons   recarice                                        namcrns soriie

                                Lowest channel                                         Lowest channel




     deses raeecoons     inisnre                                         nsenrns inss

                                    Middle channel                                         Middle channel




     deses raeons roucn                                                  smmons oncancos

                                Highest channel                                        Highest channel


Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1801073
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                       Page 15 of 38


                                                                               Report No: CCISE180107301

6.5 Power Spectral Density
        Test Requirement:                FCC Part 15 C Section 15.247 (e)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           8 dBm
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data:
           Test CH                 Power Spectral Density (dBm)             Limit(dBm)             Result
            Lowest                               -19.90
            Middle                               -18.88                       8.00                 Pass
           Highest                               -19.66




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 16 of 38


CCIS                                                                                   Report No: CCISE180107301

Test plots as follow:

     @ m




     daces anmeecoos rncreas                                             rnameros souncer

                            Lowest channel                                                  Middle channel




     daces anmeecoos ancomins

                            Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                         Project No.: CCISE1801073
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                        Page 17 of 38


                                                                               Report No: CCISE180107301

6.6 Band Edge
6.6.1 Conducted Emission Method
        Test Requirement:                FCC Part 15 C Section 15.247 (d)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           In any 100 kHz bandwidth outside the frequency band in which the
                                         spread spectrum intentional radiator is operating, the radio frequency
                                         power that is produced by the intentional radiator shall be at least 20 dB
                                         below that in the 100 kHz bandwidth within the band that contains the
                                         highest level of the desired power, based on either an RF conducted or a
                                         radiated measurement.
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 18 of 38


CCIS                                                                                        Report No: CCISE180107301

Test plots as follow:


     ® m     sea m




     oaces rnmeecoos rncoiior                                       daces roamecoons   rocuncee


                            Lowest channel                                                    Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                           Project No.: CCISE1801073
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                          Page 19 of 38


                                                                               Report No: CCISE180107301

6.6.2     Radiated Emission Method
      Test Requirement:                FCC Part15 C Section 15.209 and 15.205
      Test Method:                     ANSI C63.10: 2013 and KDB 558074
      Test Frequency Range:            960MHz to 1.240GHz
      Test site:                       Measurement Distance: 3m
      Receiver setup:                     Frequency           Detector         RBW         VBW            Remark
                                        960MHz-1GHz         Quasi-peak        120kHz      300kHz    Quasi-peak Value
                                                               Peak            1MHz        3MHz        Peak Value
                                         Above 1GHz
                                                               RMS             1MHz        3MHz       Average Value
      Limit:                                   Frequency              Limit (dBuV/m @3m)              Remark
                                            960MHz-1GHz                        54.00             Quasi-peak Value
                                                                               54.00               Average Value
                                              Above 1GHz
                                                                               74.00                Peak Value
      Test Procedure:                  1. The EUT was placed on the top of a rotating table 0.8m(below 1GHz)
                                            /1.5m(above 1GHz) above the groundat a 3 meter chamber.The table
                                            was rotated 360 degrees todetermine the position of the highest
                                            radiation.
                                       2. The EUT was set 3 meters away from the interference-receiving
                                            antenna, whichwas mounted on the top of a variable-height antenna
                                            tower.
                                       3. The antenna height is varied from one meter to four meters above the
                                            ground to determine the maximum value of the field strength. Both
                                            horizontal and vertical polarizations of the antenna are set to make the
                                            measurement.
                                       4. For each suspected emission, the EUT was arranged to its worst case
                                            and thenthe antenna was tuned to heights from 1 meter to 4 meters and
                                            the rotatablewas turned from 0 degrees to 360 degrees to find the
                                            maximum reading.
                                       5. The test-receiver system was set to Peak Detect Function and
                                            SpecifiedBandwidth with Maximum Hold Mode.
                                       6. If the emission level of the EUT in peak mode was 10dB lower than the
                                            limitspecified, then testing could be stopped and the peak values of the
                                            EUT wouldbe reported. Otherwise the emissions that did not have 10dB
                                            margin would bere-tested one by one using peak, quasi-peak or
                                            average method as specified andthen reported in a data sheet.
      Test setup:                      Below 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 20 of 38


                                                                          Report No: CCISE180107301

                                       Above 1GHz




      Test Instruments:                Refer to section 5.8 for details
      Test mode:                       Refer to section 5.3 for details
      Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                    Page 21 of 38


                                                                                     Report No: CCISE180107301

Below 1GHz:
Test channel: Highest channel
Test Polarization: Horizontal




                                                                                    QP




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 22 of 38


                                                                                     Report No: CCISE180107301


Test Polarization: Vertical




                                                                                   QP




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 23 of 38


                                                                                     Report No: CCISE180107301

Above 1GHz:
Test channel: Highest channel
Test Polarization: Horizontal




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 24 of 38


                                                                                     Report No: CCISE180107301


Test Polarization: Vertical




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 25 of 38


                                                                               Report No: CCISE180107301

6.7     Spurious Emission
6.7.1     Conducted Emission Method
        Test Requirement:                FCC Part 15 C Section 15.247 (d)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           In any 100 kHz bandwidth outside the frequency band in which the
                                         spread spectrum intentional radiator is operating, the radio frequency
                                         power that is produced by the intentional radiator shall be at least 20 dB
                                         below that in the 100 kHz bandwidth within the band that contains the
                                         highest level of the desired power, based on either an RF conducted or a
                                         radiated measurement.
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 26 of 38


CCIS                                                                                Report No: CCISE180107301

Test plot as follows:
                            Lowest channel                                               Middle channel

     @ m     sea m




     daces anmeecoos rosinicr                                            rmemnrne soas

                            30OMHz~25GHz                                             30OMHz~25GHz


                            Highest channel




     daces anmeecoos rnconise

                            30MHz~25GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1801073
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 27 of 38


                                                                                Report No: CCISE180107301

 6.7.2 Radiated Emission Method
        Test Requirement:                FCC Part 15 C Section 15.209 and 15.205
        Test Method:                     ANSI C63.10:2013
        Test Frequency Range:            9kHz to 25GHz
        Test Distance:                   3m
        Receiver setup:                    Frequency       Detector         RBW        VBW             Remark
                                          30MHz-1GHz      Quasi-peak      120KHz     300KHz       Quasi-peak Value
                                                            Peak           1MHz        3MHz           Peak Value
                                          Above 1GHz
                                                            RMS            1MHz        3MHz         Average Value
        Limit:                                  Frequency           Limit (dBuV/m @3m)              Remark
                                              30MHz-88MHz                    40.0               Quasi-peak Value
                                             88MHz-216MHz                    43.5               Quasi-peak Value
                                            216MHz-960MHz                    46.0               Quasi-peak Value
                                              960MHz-1GHz                    54.0               Quasi-peak Value
                                                                             54.0                Average Value
                                               Above 1GHz
                                                                             74.0                 Peak Value
        Test Procedure:                  1.   The EUT was placed on the top of a rotating table 0.8m(below
                                              1GHz)/1.5m(above 1GHz) above the ground at a 3 meter camber.
                                              The table was rotated 360 degrees to determine the position of the
                                              highest radiation.
                                         2.   The EUT was set 3 meters away from the interference-receiving
                                              antenna, which was mounted on the top of a variable-height antenna
                                              tower.
                                         3.   The antenna height is varied from one meter to four meters above
                                              the ground to determine the maximum value of the field strength.
                                              Both horizontal and vertical polarizations of the antenna are set to
                                              make the measurement.
                                         4.   For each suspected emission, the EUT was arranged to its worst
                                              case and then the antenna was tuned to heights from 1 meter to 4
                                              meters and the rota table was turned from 0 degrees to 360 degrees
                                              to find the maximum reading.
                                         5.   The test-receiver system was set to Peak Detect Function and
                                              Specified Bandwidth with Maximum Hold Mode.
                                         6.   If the emission level of the EUT in peak mode was 10 dB lower than
                                              the limit specified, then testing could be stopped and the peak values
                                              of the EUT would be reported. Otherwise the emissions that did not
                                              have 10 dB margin would be re-tested one by one using peak, quasi-
                                              peak or average method as specified and then reported in a data
                                              sheet.
        Test setup:                      Below 1GHz




                                         Above 1GHz
Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 28 of 38


                                                                            Report No: CCISE180107301




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed
        Remark:                          1. Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and
                                            found the Y-axis is the worst case.
                                         2. 9 kHz to 30MHz is too low, so only shows the data of above 30MHz
                                            in this report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                         Page 29 of 38


                                                                                    Report No: CCISE180107301

Measurement Data (worst case):
Below 1GHz:
Test Polarization: Horizontal




                                                                                     Fundamental wave




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                    Page 30 of 38


                                                                                    Report No: CCISE180107301


Test Polarization: Vertical




                                                                                    Fundamental wave




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                    Page 31 of 38


                                                                                  Report No: CCISE180107301

Above 1GHz:
                                             Test channel: Lowest channel
                                                 Detector: Peak Value
                  Read       Antenna        Cable       Preamp
 Frequency                                                            Level      Limit Line     Over
                  Level       Factor        Loss         Factor                                            Polarization
   (MHz)                                                            (dBuV/m)     (dBuV/m)     Limit (dB)
                 (dBuV)       (dB/m)         (dB)         (dB)
  1814.00         62.89        25.05         4.13        41.25           50.82     74.00       -23.18        Vertical
  2721.00         64.96        26.35         5.07        41.74           54.64     74.00       -19.36        Vertical
  3628.00         50.25        27.72         5.92        41.58           42.31     74.00       -31.69        Vertical
  4535.00         55.45        29.47         6.84        42.08           49.68     74.00       -24.32        Vertical
  5442.00         52.36        30.54         7.16        41.85           48.21     74.00       -25.79        Vertical



  1814.00         64.73        25.10         4.12        41.21           52.74     74.00       -21.26      Horizontal
  2721.00         63.10        26.35         5.07        41.74           52.78     74.00       -21.22      Horizontal
  3628.00         52.75        27.72         5.92        41.58           44.81     74.00       -29.19      Horizontal
  4535.00         53.84        29.47         6.84        42.08           36.48     74.00       -37.52      Horizontal
  5442.00         52.16        30.54         7.18        41.85           48.03     74.00       -25.97      Horizontal
                                                Detector: Average Value
   2721.00        61.35        26.35         5.07      41.74       51.03           54.00        -2.97        Vertical




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                  Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                  Page 32 of 38


                                                                                  Report No: CCISE180107301

                                              Test channel: Middle channel
                                                  Detector: Peak Value
                  Read       Antenna        Cable     Preamp
 Frequency                                                          Level        Limit Line     Over
                  Level       Factor        Loss       Factor                                              Polarization
   (MHz)                                                          (dBuV/m)       (dBuV/m)     Limit (dB)
                 (dBuV)       (dB/m)         (dB)       (dB)
  1830.00         59.52        25.05        4.13       41.25        47.45          74.00       -26.55        Vertical
  2745.00         59.89        26.35        5.07       41.74        49.57          74.00       -24.43        Vertical
  3660.00         50.30        27.72        5.92       41.58        42.36          74.00       -31.64        Vertical
  4575.00         52.29        29.47        6.84       42.08        46.52          74.00       -27.48        Vertical
  5490.00         52.45        30.54        7.16       41.85        48.30          74.00       -25.70        Vertical



  1830.00         60.06        25.10         4.12        41.21           48.07     74.00       -25.93      Horizontal
  2745.00         63.96        26.35         5.07        41.74           53.64     74.00       -20.36      Horizontal
  3660.00         48.47        27.72         5.92        41.58           40.53     74.00       -33.47      Horizontal
  4575.00         52.20        29.47         6.84        42.08           36.48     74.00       -37.52      Horizontal
  5490.00         52.66        30.54         7.18        41.85           48.53     74.00       -25.47      Horizontal




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                  Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                  Page 33 of 38


                                                                                    Report No: CCISE180107301

                                             Test channel: Highest channel
                                                  Detector: Peak Value
                  Read       Antenna        Cable     Preamp
 Frequency                                                         Level          Limit Line      Over
                  Level       Factor        Loss       Factor                                                Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)      Limit (dB)
                 (dBuV)       (dB/m)         (dB)       (dB)
  1845.00         59.55        24.95        4.17       41.31       40.33            74.00         -33.67       Vertical
  2767.50         59.13        26.50        5.10       41.70       43.03            74.00         -30.97       Vertical
  3690.00         48.21        27.84        5.98       41.66       40.82            74.00         -33.18       Vertical
  4612.50         52.58        29.90        6.89       42.12       46.73            74.00         -27.27       Vertical
  5535.00         52.46        30.50        7.24       41.81       51.41            74.00         -22.59       Vertical



  1845.00         58.33        24.95         4.17      41.31       43.09            74.00         -30.91     Horizontal
  2767.50         56.74        26.50         5.10      41.70       44.78            74.00         -29.22     Horizontal
  3690.00         49.38        27.84         5.98      41.66       44.89            74.00         -29.11     Horizontal
  4612.50         51.24        29.90         6.89      42.12       48.22            74.00         -25.78     Horizontal
  5535.00         52.36        30.50         7.24      41.81       55.66            74.00         -18.34     Horizontal
                                                Detector: Average Value
  5535.00         50.75        30.54         7.18        41.85           46.62      54.00          -7.38     Horizontal
 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
 2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE1801073
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                    Page 34 of 38



Document Created: 2018-06-01 15:19:35
Document Modified: 2018-06-01 15:19:35

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC