Test report

FCC ID: 2ALPH-E32-TTL-100

Test Report

Download: PDF
FCCID_3359168

                                                                               Shenzhen CTL Testing Technology Co., Ltd.
                                                                            Tel: +86-755-89486194 E-mail: ctl@ctl-lab.com


                                         TEST REPORT
                                  47 CFR FCC Part 15 Subpart C 15.231

Report Reference No. .................: CTL1702288103-WF

           Compiled by:                                         Allen Wang
( position+printed name+signature)                         (File administrators)

             Tested by:                                        Nice Nong
( position+printed name+signature)                           (Test Engineer)

           Approved by:                                          Ivan Xie
( position+printed name+signature)                              (Manager)


Product Name..............................: Wireless transceiver module
Model/Type reference .................: E32-TTL-100
Trade Mark ...................................: CDEBYTE
FCC ID ..........................................: 2ALPH-E32-TTL-100
Applicant’s name ........................: Chengdu Ebyte Electronic Technology Co., Ltd.
                                           Innovation Center D347, 4# XI-XIN Road, High-Tech
Address of applicant ..................:
                                           District(West), Chengdu, Sichuan, China
Test Firm ......................................: Shenzhen CTL Testing Technology Co., Ltd.

                                                 Floor 1-A, Baisha Technology Park, No.3011, Shahexi Road,
Address of Test Firm ..................:
                                                 Nanshan District, Shenzhen, China 518055
Test specification ........................:
Standard........................................: 47 CFR FCC Part 15 Subpart C 15.231
TRF Originator ..............................: Shenzhen CTL Testing Technology Co., Ltd.
Master TRF ...................................: Dated 2011-01
Date of Receipt............................: Mar. 01, 2017
Date of Test Date .........................: Mar. 01, 2017–Mar. 30, 2017
Data of Issue................................: Mar. 31, 2017
Result ...........................................: Pass
Shenzhen CTL Testing Technology Co., Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen CTL Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the
material. Shenzhen CTL Testing Technology Co., Ltd. takes no responsibility for and will not assume
liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.


V1.0                                          Page 2 of 23                      Report No.: CTL1702288103-WF



                                     TEST REPORT
                                                                                     Mar. 30, 2017
       Test Report No. :                 CTL1702288103-WF
                                                                                     Date of issue

       Equipment under Test      :    Wireless transceiver module


       Model /Type               :    E32-TTL-100


       Applicant                 :    Chengdu Ebyte Electronic Technology Co., Ltd.


                                 :    Innovation Center D347, 4# XI-XIN Road, High-Tech
       Address
                                      District(West), Chengdu, Sichuan, China


       Manufacturer              :    Chengdu Ebyte Electronic Technology Co., Ltd.


                                 :    Innovation Center D347, 4# XI-XIN Road, High-Tech
       Address
                                      District(West), Chengdu, Sichuan, China




                      Test result                                                Pass *
  * In the configuration tested, the EUT complied with the standards specified page 5.
   The test report merely corresponds to the test sample.
   It is not permitted to copy extracts of these test result without the written permission of the test laboratory.


V1.0                                   Page 3 of 23            Report No.: CTL1702288103-WF


                                  ** Modified History **
  Version               Description          Issued Data      Report No.         Remark
 Version 1.0   Initial Test Report Release    2017-03-31   CTL1702288103-WF      Tracy Qi


V1.0                                                                      Page 4 of 23                                         Report No.: CTL1702288103-WF



                                                                       Table of Contents                                                                                     Page
1.     SUMMARY............................................................................................................................................................ 5
     1.1.     TEST STANDARDS..........................................................................................................................................................5
     1.2.     TEST DESCRIPTION ........................................................................................................................................................5
     1.3.     TEST FACILITY ..............................................................................................................................................................6
     1.4.     STATEMENT OF THE MEASUREMENT UNCERTAINTY ...............................................................................................................6
2.     GENERAL INFORMATION....................................................................................................................................... 7
     2.1.     ENVIRONMENTAL CONDITIONS ........................................................................................................................................7
     2.2.     GENERAL DESCRIPTION OF EUT ......................................................................................................................................7
     2.3.     EQUIPMENTS USED DURING THE TEST ..............................................................................................................................7
     2.4.     RELATED SUBMITTAL(S) / GRANT (S)................................................................................................................................8
     2.5.     MODIFICATIONS ...........................................................................................................................................................8
3.     TEST CONDITIONS AND RESULTS ........................................................................................................................... 9
     3.1.     CONDUCTED EMISSION (AC MAIN) .................................................................................................................................9
     3.2.     RADIATED EMISSION ...................................................................................................................................................12
     3.3.     20DB BANDWIDTH .....................................................................................................................................................16
     3.4.     DEACTIVATION TIME ...................................................................................................................................................17
     3.5.     ANTENNA REQUIREMENT .............................................................................................................................................18
4.     TEST SETUP PHOTOS OF THE EUT ........................................................................................................................ 19
5.     EXTERNAL AND INTERNAL PHOTOS OF THE EUT .................................................................................................. 21


V1.0                                      Page 5 of 23                 Report No.: CTL1702288103-WF


1. SUMMARY
1.1. Test Standards
The tests were performed according to following standards:

FCC Rules Part 15.231: Periodic operation in the band 40.66-40.70 MHz and above 70 MHz.

ANSI C63.10:2013 : American National Standard for Testing Unlicensed Wireless Devices

ANSI C63.4: 2014: –American National Standard for Methods of Measurement of Radio-Noise
Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40GHz
Range of 9 kHz to 40GHz

1.2. Test Description
FCC and IC Requirements
FCC Part 15.207                          Conducted Emission                                 N/A
FCC Part 15.231(a)(2)                    Automatically Deactivate                          PASS
FCC Part 15.231(b)                       Electric Field Strength of Fundamental Emission   PASS
FCC Part 15.205 &15.209& 15.231(b)       Electric Field Strength of Spurious Emission      PASS
FCC Part 15.231(c)                   -20dB bandwidth                                       PASS
   Remark: The measurement uncertainty is not included in the test result.


V1.0                                        Page 6 of 23                  Report No.: CTL1702288103-WF



1.3. Test Facility
1.3.1   Address of the test laboratory
Shenzhen CTL Testing Technology Co., Ltd.
Floor 1-A, Baisha Technology Park, No. 3011, Shahexi Road, Nanshan, Shenzhen 518055 China

There is one 3m semi-anechoic chamber and two line conducted labs for final test. The Test Sites
meet the requirements in documents ANSI C63.4 and CISPR 22/EN 55022 requirements.

1.3.2   Laboratory accreditation
The test facility is recognized, certified, or accredited by the following organizations:
IC Registration No.: 9618B
The 3m alternate test site of Shenzhen CTL Testing Technology Co., Ltd. EMC Laboratory has been
registered by Certification and Engineer Bureau of Industry Canada for the performance of with
Registration No.: 9618B on November 13, 2013.
FCC-Registration No.: 970318
Shenzhen CTL Testing Technology Co., Ltd. EMC Laboratory has been registered and fully described
in a report filed with the (FCC) Federal Communications Commission. The acceptance letter from the
FCC is maintained in our files. Registration 970318, December 19, 2013.

1.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that
there may be errors within the calibration limits of the equipment and facilities. The measurement
uncertainty was calculated for all measurements listed in this test report acc. to CISPR 16 - 4
“Specification for radio disturbance and immunity measuring apparatus and methods – Part 4:
Uncertainty in EMC Measurements“ and is documented in the Shenzhen CTL Testing Technology Co.,
Ltd. quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of
devices similar to that tested may result in additional deviation. The manufacturer has the sole
responsibility of continued compliance of the device.

Hereafter the best measurement capability for CTL laboratory is reported:
                                                                    Measurement
                             Test                                                         Notes
                                                                      Uncertainty
                Transmitter power conducted                            ±0.57 dB            (1)
                 Transmitter power Radiated                            ±2.20 dB            (1)
        Conducted spurious emission 9KHz-40 GHz                        ±2.20 dB            (1)
                    Occupied Bandwidth                                 ±0.01ppm            (1)
               Radiated Emission 30~1000MHz                             ±4.10dB            (1)
               Radiated Emission Above 1GHz                             ±4.32dB            (1)
             Conducted Disturbance0.15~30MHz                            ±3.20dB            (1)
  (1) This uncertainty represents an expanded uncertainty expressed at approximately the 95%
      confidence level using a coverage factor of k=2.


V1.0                                            Page 7 of 23                 Report No.: CTL1702288103-WF


2. GENERAL INFORMATION
2.1. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
                Normal Temperature:                                            25°C
                    Relative Humidity:                                         55 %
                      Air Pressure:                                           101 kPa

2.2. General Description of EUT
Product Name:                         Wireless transceiver module
Model/Type reference:                 E32-TTL-100
Power supply:                         DC 3.3V
Modulation:                           LoraTM
Operation frequency:                  434MHz
Channel number:                       1
Antenna type:                         External antenna
Antenna gain:                    2.0dBi
Note: For more details, please refer to the user’s manual of the EUT.

2.3. Equipments Used during the Test
                                                                                  Calibration   Calibration
 Test Equipment             Manufacturer         Model No.      Serial No.
                                                                                    Date        Due Date
         LISN                   R&S               ENV216       3560.6550.12       2016/06/02    2017/06/01
         LISN                   R&S               ESH2-Z5      860014/010         2016/06/02    2017/06/01
                          Sunol Sciences
  Bilog Antenna                                     JB1          A061713          2016/06/02    2017/06/01
                              Corp.
EMI Test Receiver               R&S                 ESCI            103710        2016/06/02    2017/06/01
Spectrum Analyzer              Agilent             N9020       US46220290         2017/01/17    2018/01/16
                                               Controller EM
       Controller          EM Electronics                            N/A          2016/05/21    2017/05/20
                                                  1000
                          Sunol Sciences
  Horn Antenna                                    DRH-118        A062013          2016/05/19    2017/05/18
                              Corp.
   Active Loop              SCHWARZBE
                                                 FMZB1519       1519-037          2016/05/19    2017/05/18
    Antenna                    CK
       Amplifier               Agilent             8349B       3008A02306         2016/05/19    2017/05/18
       Amplifier               Agilent             8447D       2944A10176         2016/05/19    2017/05/18
Temperature/Humi
                             Gangxing             CTH-608            02           2016/05/20    2017/05/19
dity Meter
                                               9SH10-2700/X
High-Pass Filter                K&L                                  N/A          2016/05/20    2017/05/19
                                                12750-O/O
                                               41H10-1375/U
High-Pass Filter                K&L                                  N/A          2016/05/20    2017/05/19
                                                12750-O/O


V1.0                                     Page 8 of 23                 Report No.: CTL1702288103-WF

                      HUBER+SUHN          SUCOFLEX
  Coaxial Cables                                                10m         2016/06/02     2017/06/01
                          ER             104PEA-10M
                      HUBER+SUHN          SUCOFLEX
  Coaxial Cables                                                3m          2016/06/02     2017/06/01
                          ER              104PEA-3M
                      HUBER+SUHN          SUCOFLEX
  Coaxial Cables                                                3m          2016/06/02     2017/06/01
                          ER              104PEA-3M
       RF Cable          Megalon            RF-A303             N/A         2016/06/02     2017/06/01
The calibration interval was one year

2.4. Related Submittal(s) / Grant (s)
This submittal(s) (test report) is intended to comply with Section 15.231 of the FCC Part 15, Subpart C
Rules.

2.5. Modifications
No modifications were implemented to meet testing criteria.


V1.0                                        Page 9 of 23                Report No.: CTL1702288103-WF


3. TEST CONDITIONS AND RESULTS
3.1. Conducted Emission (AC Main)
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.207

                                                                  Limit (dBuV)
          Frequency range (MHz)
                                                    Quasi-peak                      Average

                  0.15-0.5                            66 to 56*                     56 to 46*

                   0.5-5                                   56                          46

                    5-30                                   60                          50

* Decreases with the logarithm of the frequency.

TEST CONFIGURATION




TEST PROCEDURE

1.     The equipment was set up as per the test configuration to simulate typical actual usage per the
       user’s manual. The EUT is a flood stand system; a wooden table with a height of 0.1 meters is
       used and is placed on the ground plane as per ANSI C63.10-2013.
2.     Support equipment, if needed, was placed as per ANSI C63.10-2013
3.     All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10-2013
4.     If a EUT received DC power from the USB Port of Notebook PC, the PC’s adapter received
       AC120V/60Hz power through a Line Impedance Stabilization Network (LISN) which supplied
       power source and was grounded to the ground plane.
5.     All support equipments received AC power from a second LISN, if any.
6.     The EUT test program was started. Emissions were measured on each current carrying line of the
       EUT using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN
       has two monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken:
       one with Line 1 connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the
       second scan had Line 1 connected to a 50 ohm load and Line 2 connected to the Analyzer /
       Receiver.
7.     Analyzer / Receiver scanned from 150 KHz to 30MHz for emissions in each of the test modes.
8.     During the above scans, the emissions were maximized by cable manipulation.
TEST RESULTS


SCAN TABLE:          "Voltage          (K—30M)FIN®
  Short Description:                               150R—30M voltage

  Leve! poyy)
To
so
so
«0
s
20                                                                                i    i
 10                              i            i                                   fI4CH          i
      10         sook: aook     e00% #00k 1M                  m      an     an Sm 6M    on To   zow   som
                                                          Frequencyz)
x x ies cmaresos200_tin



MEASUREMENT RESULT:                   "CTL170304200_fin"

3/4/2017        10:212M
      Erequency        Level         Transd       Limit Margin        Detector     Line    PB
            wz          aspy             as        amuy     as
       0270000         50 .20          10.2          65       14.8.   op           2l     cxp
       0.226000        47.00           10.2          63       is.6.   op           11     cxp
       0.494000        47.00           10.2          se        9.10   oe           11     cxp
       1.220000        41.70           10.3          se       10.3     op          11     cxp
       1.256000        42. 60          10.3          se       13.4     or          1      cxp


MEASUREMENT RESULT:                   "CTL170304200_fin2"

3/4/2017        10:212m
      Erequency        Level         Transd       Limit Margin        Detector     Line    PB
            wz          aspy             as        amuy     as
       0.494000        37.20           10.2          46        8.9    ay           2l     cxp
       1.172000        31.30           10.3          46       10.7.   ay           11     cxp
       1.214000        33.10           10.3          46       12.0     ay          11     cxp
       1.256000        33. 90          10.3          46       12.1.   ay           11     cxp
       1.292000        34.80           10.3          46       11.2.   ay           1      cxp


SCAN TABLE:      "Voltage     (9K—30M)FIN®
  Short Description:                  150R—30M voltage

  Level dBav)
 to
 so
 so
 «0
 so
 20
 10



                                             Frequency z)
x x xugs crtarososzoi_tin



MEASUREMENT RESULT:          "CTL170304201_fin"

3/4/2017    10:24mm
   Frequency       Level    Transd   Limit Margin           Detector   Lins    9B
         wz         aspy        as    amuy
    0.166000       s1.00      10.2      65       14.2.      op         w      cxp
    0.446000       42. 80     10.2      s7       16.1.      op         w      cxp
    0500000        38.80      10.2      se        i7.2      or         w      cxp
    1.598000       40 .20     10.3      se       is.s       or         w      cxp


MEASUREMENT RESULT: "CTL170304201_fin2"
3/4/2017 10:24mM
   Erequency   Level        Transd   Limit Margin           Detector   Line    PB
         wz      aspy           as    amuy     as
    1.124000       30.10      10.3      a6       15.9    ay            w      cxp
    1.208000       31.40      10.3      46       14.6)   ay            w      cxp
    1.484000       32. 90     10.3      46       131.    ay            w      cxp
    1.832000       32.20      10.3      a6       13.8    ay            w      cxp
    2.060000       29.40      10.4      a6       16.6    ay            w      cxp


V1.0                                      Page 12 of 23                 Report No.: CTL1702288103-WF


3.2. Radiated Emission
Limit
For intentional device, according to 15.209(a) the general requirement of field strength of radiated
emission from intentional radiators at a distance of 3 meters shall not exceed the following table.
  Frequency (MHz)       Distance (Meters)              Radiated (dBμV/m)               Radiated (μV/m)
       0.009-0.49                3             20log(2400/F(KHz))+40log(300/3)           2400/F(KHz)
       0.49-1.705                3             20log(24000/F(KHz))+ 40log(30/3)         24000/F(KHz)
        1.705-30                 3                   20log(30)+ 40log(30/3)                   30
         30-88                   3                            40.0                            100
        88-216                   3                            43.5                            150
        216-960                  3                            46.0                            200
       Above 960                 3                            54.0                            500
In addition to the provisions of 15.231(b) and RSS 210-A1.1.2, the field strength of emissions from
intentional radiators operated under this section shall not exceed the following:




[Where F is the frequency in MHz, the formulas for calculating the maximum permitted fundamental
field strengths are as follows: for the band 260-470 MHz, μV/m at 3 meters =41.6667(F) - 7083.3333.
The maximum permitted unwanted emission level is 20 dB below the maximum permitted fundamental
level.]

TEST CONFIGURATION
                        (A) Radiated Emission Test Set-Up, Frequency Below 30MHz


V1.0                                      Page 13 of 23                Report No.: CTL1702288103-WF


                        (B) Radiated Emission Test Set-Up, Frequency below 1000MHz




                        (C) Radiated Emission Test Set-Up, Frequency above 1000MHz




Test Procedure

1.     Below 1GHz measurement the EUT is placed on a turntable which is 0.8m above ground plane,
       and above 1GHz measurement EUT was placed on a low permittivity and low loss tangent turn
       table which is 1.5m above ground plane.
2.     Maximum procedure was performed by raising the receiving antenna from 1m to 4m and rotating
       the turn table from 0℃ to 360℃ to acquire the highest emissions from EUT
3.     And also, each emission was to be maximized by changing the polarization of receiving antenna
       both horizontal and vertical.
4.     Repeat above procedures until all frequency measurements have been completed.


V1.0                                            Page 14 of 23                      Report No.: CTL1702288103-WF


TEST RESULTS

The emissions from 30MHz to 5GHz are measured peak and average level, below 1 GHz measured
QP level, detailed test data please see below. Besides, we tested 3 directions and recorded the worst
data.

        Emission          Frequency            Reading            Limit         Margin                        Direction
                                                                                              Detector
         Styles             (MHz)             (dBuV/m)          (dBuV/m)         (dB)                          (H/V)
      Fundamental           434.00             85.73             100.83         15.10           PK               H
        Spurious            435.08             58.09              80.83         22.74           PK               H
       Harmonics            868.00             64.48              80.83         16.35           PK               H
       Harmonics           1302.00             61.05              80.83         19.78           PK               H
            --                --                 --                --             --             --              --
      Fundamental           434.00             86.38             100.83         14.45           PK               V
        Spurious            435.08             57.70              80.83         23.13           PK               V
       Harmonics            868.00             65.04              80.83         15.79           PK               V
       Harmonics           1302.00             61.25              80.83         19.58           PK               V
            --                  --               --                --             --             --              --



                                        PK                             AV
      Emission        Frequency                       AV Factor                     Limit         Margin      Direction
                                       Level                          Level
       Styles           (MHz)                          (dB/m)                     (dBuV/m)         (dB)        (H/V)
                                     (dBuV/m)                       (dBuV/m)
     Fundamental        434.00        85.73             -7.54           78.19          80.83          2.64        H
      Spurious          435.08        58.09             -7.54           50.55          60.83          10.28       H
     Harmonics          868.00        64.48             -7.54           56.94          60.83          3.89        H
     Harmonics         1302.00        61.05             -7.54           53.51          60.83          7.32        H
          --              --            --               --               --             --            --         --
     Fundamental        434.00        86.38             -7.54           78.84          80.83          1.99        V
      Spurious          435.08        57.70             -7.54           50.16          60.83          10.67       V
     Harmonics          868.00        65.04             -7.54           57.50          60.83          3.33        V
     Harmonics         1302.00        61.25             -7.54           53.71          60.83          7.12        V
          --               --            --              --               --             --            --         --
Note:
1.     AV Level (dBuV/m)= PK Level (dBuV/m)+ AV Factor(dB)
2.     In transmit 100ms found 1.05ms burst 34pcs, 0.45ms burst 14pcs, the Duty Cycle can calculate as below:
       Duty Cycle= (1.05 *34+0.45*14)/100=0.42
       AV Factor=20*log(Duty Cycle)=20*log(0.42)=-7.54
(The plot of Duty Cycle See the follow page)


V1.0   Page 15 of 23   Report No.: CTL1702288103-WF


V1.0                                     Page 16 of 23                Report No.: CTL1702288103-WF



3.3. 20dB Bandwidth
Limit
According to 47 CFR 15.231(c) The bandwidth of the emission shall be no wider than 0.25% of the
centre frequency for devices operating above 70MHz and below 900MHz. Bandwidth is determined at
the points 20dB down from the modulated carrier.

Test Configuration



                                                               Spectrum
                              EUT
                                                               Analyzer



Test Procedure

The 20dB bandwidth and 99% bandwidth is measured with a spectrum analyzer connected via a
receive antenna placed near the EUT while the EUT is operating in transmission mode.
The 20dB bandwidth is defined as the total spectrum the power of which is higher than peak power
minus 20dB.
The occupied bandwidth (OBW), that is the frequency bandwidth such that, below its lower and above
its upper frequency limits, the mean powers radiated are each equal to 0.5 percent of the total mean
power radiated by a given emission.

Test Results


                  Channel
                                    99% OBW       20dB bandwidth           Limit
 Modulation      Frequency                                                                 Result
                                      (KHz)           (KHz)               (KHz)
                   (MHz)
       ASK              434          160.26           187.90       0.25%*434000=1085        Pass
Test plot as follows:
                                              ASK Modulation


V1.0                                        Page 17 of 23               Report No.: CTL1702288103-WF



3.4. Deactivation Time
Limit

According to FCC §15.231(a)(2), A transmitter activated automatically shall cease transmission
within 5 seconds after activation.

Test Configuration




                                                            Spectrum
                         EUT
                                                            Analyzer



Test Procedure


1.     The EUT was placed on a wooded table which is 0.8m height and close to receiver antenna of
       spectrum analyzer.
2.     The spectrum analyzer resolution bandwidth was set to 1 MHz and video bandwidth was set to 1
       MHz to encompass all significant spectral components during the test. The spectrum analyzer was
       operated in linear scale and zero span mode after tuning to the transmitter carrier frequency.


TEST RESULTS

Note: The transmitter was automatically activated, and the carrier frequency 434MHz:
         Frequency          One transmission time
                                                             Limit(S)                  Result
           (MHz)                     (S)
            434                      0.37                       5                      Pass


V1.0                                      Page 18 of 23                 Report No.: CTL1702288103-WF


3.5. Antenna Requirement

Standard Applicable

According to FCC Part 15C 15.203
a) An intentional radiator shall be de-signed to ensure that no antenna other than that furnished by
   the responsible party shall be used with the device.
b) The manufacturer may design the unit so that a broken antenna can be replaced by the user, but
   the use of a standard antenna jack or electrical connector is prohibited.

Refer to statement below for compliance.
The manufacturer may design the unit so that the user can replace a broken antenna, but the use of a
standard antenna jack or electrical connector is prohibited. Further, this requirement does not apply to
intentional radiators that must be professionally installed.

Antenna Connected Construction

The antenna used in this product is non-standard External Antenna, The directional gains of antenna
used for transmitting is 2 dBi.


V1.0                     Page 19 of 23   Report No.: CTL1702288103-WF


4. Test Setup Photos of the EUT


V1.0   Page 20 of 23   Report No.: CTL1702288103-WF


V1.0                      Page 21 of 23      Report No.: CTL1702288103-WF


5. External and Internal Photos of the EUT


V1.0   Page 22 of 23   Report No.: CTL1702288103-WF


V1.0                       Page 23 of 23                Report No.: CTL1702288103-WF




       ********************** End of Report **********************



Document Created: 2017-04-14 16:20:05
Document Modified: 2017-04-14 16:20:05

© 2025 FCC.report