Test Report_DTS

FCC ID: 2ALPH-E22900T22S

Test Report

Download: PDF
FCCID_4101474

                         Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                       Report No: CCISE181101401

         1        Cover Page
                                          FCC REPORT
                                                          (RFID)

Applicant:                             Chengdu Ebyte Electronic Technology Co., Ltd.
                                       Innovation Center D347, 4# XI-XIN road, High-tech district(west),
Address of Applicant:
                                       Chengdu, Sichuan, China
Equipment Under Test (EUT)

    Product Name:                      Lora Module

    Model No.:                         E22-900T22S

    Trade mark:                        EBYTE

FCC ID:                                2ALPH-E22900T22S

Applicable standards:                  FCC CFR Title 47 Part 15 Subpart C Section 15.247

Date of sample receipt:                07 Nov., 2018

Date of Test:                          07 Nov., to 21 Nov., 2018

Date of report issued:                 22 Nov., 2018

Test Result:                           PASS *

*   In the configuration tested, the EUT complied with the standards specified above.




Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate
to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer
should ensure that all products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than
that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted
to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested
and such sample(s) are retained for 90 days only.


                                                                                 Report No: CCISE181101401


2      Version
      Version No.                        Date                                    Description
            00                     22 Nov., 2018                                   Original




    Tested by:                                                           Date:          22 Nov., 2018

                                        Test Engineer


    Reviewed by:                                                         Date:          22 Nov., 2018

                                      Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 2 of 36


                                                                                                                       Report No: CCISE181101401

3         Contents
                                                                                                                                                                         Page
1       COVER PAGE ....................................................................................................................................................... 1
2       VERSION ............................................................................................................................................................... 2
3       CONTENTS ........................................................................................................................................................... 3
4       TEST SUMMARY .................................................................................................................................................. 4
5       GENERAL INFORMATION .................................................................................................................................. 5
    5.1         CLIENT INFORMATION ............................................................................................................................................ 5
    5.2         GENERAL DESCRIPTION OF E.U.T........................................................................................................................ 5
    5.3         TEST ENVIRONMENT AND TEST MODE ................................................................................................................... 6
    5.4         DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 6
    5.5         MEASUREMENT UNCERTAINTY.............................................................................................................................. 6
    5.6         LABORATORY FACILITY.......................................................................................................................................... 6
    5.7         LABORATORY LOCATION ....................................................................................................................................... 7
    5.8         TEST INSTRUMENTS LIST ....................................................................................................................................... 7
6       TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1     ANTENNA REQUIREMENT: ...................................................................................................................................... 8
    6.2     CONDUCTED EMISSION ......................................................................................................................................... 9
    6.3     CONDUCTED OUTPUT POWER ............................................................................................................................ 12
    6.4     OCCUPY BANDWIDTH .......................................................................................................................................... 14
    6.5     POWER SPECTRAL DENSITY ............................................................................................................................... 16
    6.6     BAND EDGE ......................................................................................................................................................... 18
       6.6.1 Conducted Emission Method...................................................................................................................... 18
       6.6.2 Radiated Emission Method ......................................................................................................................... 20
    6.7     SPURIOUS EMISSION ........................................................................................................................................... 26
       6.7.1 Conducted Emission Method...................................................................................................................... 26
       6.7.2 Radiated Emission Method ......................................................................................................................... 28
7       TEST SETUP PHOTO ........................................................................................................................................ 33
8       EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 35




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                             Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                      Page 3 of 36


                                                                                      Report No: CCISE181101401

 4      Test Summary
                       Test Items                                Section in CFR 47                  Result
                  Antenna requirement                             15.203/15.247 (c)                  Pass
         AC Power Line Conducted Emission                                 15.207                     Pass
            Conducted Peak Output Power                              15.247 (b)(3)                   Pass
                6dB Emission Bandwidth                               15.247 (a)(2)                   Pass
                 Power Spectral Density                                  15.247 (e)                  Pass
                       Band Edge                                         15.247(d)                   Pass
     Conducted and radiated Spurious Emission                       15.205/15.209                    Pass
     Remark:
     Pass: Meet the requirement. N/A: Not Applicable for Non-adaptive equipment.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 4 of 36


                                                                              Report No: CCISE181101401

5       General Information
5.1 Client Information
         Applicant:                      Chengdu Ebyte Electronic Technology Co., Ltd.
         Address:                        Innovation Center D347, 4# XI-XIN road, High-tech district(west),
                                         Chengdu, Sichuan, China
         Manufacturer/Factory:           Chengdu Ebyte Electronic Technology Co., Ltd.
         Address:                        Innovation Center D347, 4# XI-XIN road, High-tech district(west),
                                         Chengdu, Sichuan, China

5.2 General Description of E.U.T.
         Product Name:                   Lora Module
         Model No.:                      E22-900T22S
         Operation Frequency:            903-927 MHz
         Channel numbers:                25
         Channel separation:             1 MHz
         Modulation technology:          Lora
         Antenna Type:                   External Antenna
         Antenna gain:                   3.0 dBi
         Power supply:                   DC 5V
         Test Sample Condition:          The test samples were provided in good working order with no visible
                                         defects.


    Operation Frequency each of channel
     Channel       Frequency         Channel         Frequency         Channel             Frequency
        0           903MHz              10            913MHz              20                 923MHz
        1           904MHz              11            914MHz              21                 924MHz
        2           905MHz              12            915MHz              22                 925MHz
        3           906MHz              13            916MHz              23                 926MHz
        4           907MHz              14            917MHz              24                 927MHz
        5           908MHz              15            918MHz
        6           909MHz              16            919MHz
        7           910MHz              17            920MHz
        8           911MHz              18            921MHz
        9           912MHz              19            922MHz
    Note:
    In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the
    middle frequency, and the highest frequency of channel were selected to perform the test. Channel No. 0,
    12 & 24 were selected as Lowest, Middle and Highest channel.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 5 of 36


                                                                              Report No: CCISE181101401

5.3 Test environment and test mode
 Operating Environment:
     Temperature:                      24.0 C
     Humidity:                         54 % RH
     Atmospheric Pressure:             1010 mbar
 Test mode:
     Transmitting mode                 Keep the EUT in continuous transmitting with modulation
 The sample was placed 0.8m (below 1GHz)/1.5m (above 1GHz) above the ground plane of 3m chamber.
 Measurements in both horizontal and vertical polarities were performed. During the test, each emission was
 maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3
 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting
 cables, rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertical
 polarizations. The emissions worst-case are shown in Test Results of the following pages. Duty cycle setting
 during the transmission is 100% with maximum power setting for all modulations.

5.4 Description of Support Units
       Manufacturer               Description                 Model               S/N            FCC ID/DoC
           DELL                        PC                 OPTIPLEX745             N/A                DoC
           DELL                    MONITOR                  E178FPC               N/A                DoC
           DELL                   KEYBOARD                   SK-8115              N/A                DoC
           DELL                     MOUSE                   MOC5UO                N/A                DoC
          EBYTE                     Test suite              E15-UTL1              N/A                N/A

5.5 Measurement Uncertainty
                    Parameters                                            Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                    ±2.22 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                    ±2.76 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                   ±4.28 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                     ±5.72 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                    ±2.88 dB (k=2)

5.6 Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
        FCC - Registration No.: 727551
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
       (Federal Communications Commission). The Registration No. is 727551.
        IC - Registration No.: 10106A-1
       The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
       with Registration No.: 10106A-1.
        CNAS - Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.
        A2LA - Registration No.: 4346.01
       This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
       17025:2005 General requirements for the competence of testing and calibration laboratories. The test
       scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf

Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 6 of 36


                                                                                   Report No: CCISE181101401

5.7 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bao’an District, Shenzhen, Guangdong, China
        Tel: +86-755-23118282, Fax: +86-755-23116366
        Email: info@ccis-cb.com, Website: http://www.ccis-cb.com

5.8 Test Instruments list
 Radiated Emission:
                                                                                           Cal. Date        Cal. Due date
    Test Equipment            Manufacturer             Model No.          Serial No.
                                                                                          (mm-dd-yy)         (mm-dd-yy)
       3m SAC                  SAEMC                   9m*6m*6m             966           07-22-2017         07-21-2020
  BiConiLog Antenna         SCHWARZBECK                VULB9163             497           03-16-2018         03-15-2019
    Horn Antenna            SCHWARZBECK               BBHA9120D             916           03-16-2018         03-15-2019
    Horn Antenna            SCHWARZBECK               BBHA9120D             1805          06-22-2017         06-21-2020
                                                                                          11-21-2017         11-20-2018
     Horn Antenna           SCHWARZBECK               BBHA 9170          BBHA9170582
                                                                                          11-21-2018         11-20-2019
   EMI Test Software            AUDIX                     E3                        Version: 6.110919b
     Pre-amplifier                HP                    8447D            2944A09358     03-07-2018           03-06-2019
     Pre-amplifier                CD                   PAP-1G18             11804       03-07-2018           03-06-2019
   Spectrum analyzer        Rohde & Schwarz             FSP30              101454       03-07-2018           03-06-2019
                                                                                       11-21-2017            11-20-2018
   Spectrum analyzer        Rohde & Schwarz              FSP40             100363
                                                                                       11-21-2018            11-20-2019
   EMI Test Receiver        Rohde & Schwarz            ESRP7                101070        03-07-2018         03-06-2019
   Simulated Station            Anritsu               MT8820C            6201026545       03-07-2018         03-06-2019
        Cable                   ZDECL               Z108-NJ-NJ-81          1608458        03-07-2018         03-06-2019
        Cable                MICRO-COAX               MFR64639             K10742-5       03-07-2018         03-06-2019
        Cable                  SUHNER               SUCOFLEX100           58193/4PE       03-07-2018         03-06-2019


 Conducted Emission:
                                                                                           Cal. Date        Cal. Due date
    Test Equipment            Manufacturer             Model No.          Serial No.
                                                                                          (mm-dd-yy)         (mm-dd-yy)
   EMI Test Receiver        Rohde & Schwarz              ESCI              101189         03-07-2018         03-06-2019
     Pulse Limiter          SCHWARZBECK              OSRAM 2306             9731          03-07-2018         03-06-2019
         LISN                    CHASE                 MN2050D              1447          03-19-2018         03-18-2019
         LISN               Rohde & Schwarz            ESH3-Z5           8438621/010      07-21-2018         07-20-2019
         Cable                     HP                   10503A               N/A          03-07-2018         03-06-2019
   EMI Test Software             AUDIX                     E3                          Version: 6.110919b




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                  Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 7 of 36


                                                                          Report No: CCISE181101401

6      Test results and Measurement Data
6.1 Antenna requirement:
        Standard requirement:          FCC Part 15 C Section 15.203 /247(c)
        15.203 requirement:
        An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
        responsible party shall be used with the device. The use of a permanently attached antenna or of an
        antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
        so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
        electrical connector is prohibited.
        15.247(c) (1)(i) requirement:
        (i) Systems operating in the 2400-2483.5 MHz band that is used exclusively for fixed. Point-to-point
        operations may employ transmitting antennas with directional gain greater than 6dBi provided the
        maximum conducted output power of the intentional radiator is reduced by 1 dB for every 3 dB that the
        directional gain of the antenna exceeds 6dBi.
       E.U.T Antenna:
       The BLE antenna is an External antenna which cannot replace by end-user, the best-case gain of the
       antenna is 3 dBi.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                          Page 8 of 36


                                                                              Report No: CCISE181101401

6.2 Conducted Emission
       Test Requirement:                FCC Part 15 C Section 15.207
       Test Method:                     ANSI C63.10: 2013
       Test Frequency Range:            150 kHz to 30 MHz
       Class / Severity:                Class B                 Class B
       Receiver setup:                  RBW=9kHz, VBW=30kHz
       Limit:                                                                         Limit (dBuV)
                                        Frequency range (MHz)
                                                                        Quasi-peak                  Average
                                                0.15-0.5                  66 to 56*                 56 to 46*
                                                  0.5-5                      56                        46
                                                  5-30                       60                        50
                                        * Decreases with the logarithm of the frequency.
       Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                            line impedance stabilization network (L.I.S.N.), which provides a
                                            50ohm/50uH coupling impedance for the measuring equipment.
                                        2. The peripheral devices are also connected to the main power through
                                            a LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                            termination. (Please refer to the block diagram of the test setup and
                                            photographs).
                                        3. Both sides of A.C. line are checked for maximum conducted
                                            interference. In order to find the maximum emission, the relative
                                            positions of equipment and all of the interface cables must be changed
                                            according to ANSI C63.4: 2014 on conducted measurement.
       Test setup:




       Test Instruments:                Refer to section 5.8 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 9 of 36


                                                                                  Report No: CCISE181101401

Measurement Data:
Product name:             Lora Module                            Product model:     E22-900T22S
Test by:                  Zora                                   Test mode:         Tx mode
Test frequency:           150 kHz ~ 30 MHz                       Phase:             Line
Test voltage:             AC 120 V/60 Hz                         Environment:       Temp: 22.5℃      Huni: 55%




Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 10 of 36


                                                                                  Report No: CCISE181101401


Product name:             Lora Module                            Product model:     E22-900T22S
Test by:                  Zora                                   Test mode:         Tx mode
Test frequency:           150 kHz ~ 30 MHz                       Phase:             Neutral
Test voltage:             AC 120 V/60 Hz                         Environment:       Temp: 22.5℃     Huni: 55%




Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 11 of 36


                                                                                Report No: CCISE181101401

6.3 Conducted Output Power
        Test Requirement:                FCC Part 15 C Section 15.247 (b)(3)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           30dBm
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data:
                                Maximum Conducted Output Power
          Test CH                                                              Limit(dBm)              Result
                                           (dBm)
           Lowest                                 22.62
           Middle                                 22.48                          30.00                  Pass
          Highest                                 22.25




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 12 of 36


                                                                                                                                       Report No: CCISE181101401

Test plot as follows:
                                                       * RBW   1 MHz   Marker 1 [T1 ]                                                                  * RBW   1 MHz   Marker 1 [T1 ]
                                                       * VBW   3 MHz              22.62 dBm                                                            * VBW   3 MHz              22.48 dBm
           Ref    36.5 dBm         * Att   40 dB        SWT 2.5 ms        902.960000000 MHz                Ref    36.5 dBm         * Att   40 dB        SWT 2.5 ms        914.930000000 MHz

                 Offset   6.5 dB                                                                                 Offset   6.5 dB

           30                                                                                              30
                                                                                              A                                                                                               A
                                                   1                                                                                               1

    1 PK   20                                                                                       1 PK   20
    MAXH                                                                                            MAXH
                                                                                              LVL                                                                                             LVL

           10                                                                                              10



           0                                                                                               0



           -10                                                                                             -10



           -20                                                                                3DB          -20                                                                                3DB




           -30                                                                                             -30



           -40                                                                                             -40



           -50                                                                                             -50



           -60                                                                                             -60

           Center 903 MHz                      500 kHz/                          Span 5 MHz                Center 915 MHz                      500 kHz/                          Span 5 MHz




    Date: 12.NOV.2018         10:58:47                                                              Date: 12.NOV.2018         10:59:53


                                           Lowest channel                                                                                  Middle channel


                                                       * RBW   1 MHz   Marker 1 [T1 ]
                                                       * VBW   3 MHz              22.25 dBm
           Ref    36.5 dBm         * Att   40 dB        SWT 2.5 ms        927.020000000 MHz

                 Offset   6.5 dB

           30
                                                                                              A
                                                   1

    1 PK   20
    MAXH
                                                                                              LVL

           10



           0



           -10



           -20                                                                                3DB




           -30



           -40



           -50



           -60

           Center 927 MHz                      500 kHz/                          Span 5 MHz




    Date: 12.NOV.2018         11:00:37


                                           Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                                                       Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                                                Page 13 of 36


                                                                                Report No: CCISE181101401

6.4 Occupy Bandwidth
        Test Requirement:                FCC Part 15 C Section 15.247 (a)(2)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           >500kHz
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data:
         Test CH               6dB Emission Bandwidth (MHz)                 Limit(kHz)            Result
          Lowest                              0.592
          Middle                              0.576                           >500                 Pass
         Highest                              0.580

         Test CH               99% Occupy Bandwidth (MHz)                   Limit(kHz)            Result
          Lowest                              0.668
          Middle                              0.656                            N/A                  N/A
         Highest                              0.640




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 14 of 36


CCIS                                                                                       Report No: CCISE181101401

Test plot as follows:
                                  6dB EBW                                                         99% OBW
   ® se    se uen




   orte: 1e mov. z0e incsacee                                     o o 12 m0v.c010 mcoscee

                                Lowest channel                                                  Lowest channel




   orte: re mov. z0e nciaise                                        «s a2 mov.zore   incsscer

                                Middle channel                                                  Middle channel




   onte: 12 mov.zoe rncor:00                                      o o resev.coe. noiar

                                Highest channel                                                 Highest channel


Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                             Project No.: CCISE1811014
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                            Page 15 of 36


                                                                               Report No: CCISE181101401

6.5 Power Spectral Density
        Test Requirement:                FCC Part 15 C Section 15.247 (e)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           8 dBm
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data:
           Test CH                 Power Spectral Density (dBm)             Limit(dBm)             Result
            Lowest                                4.07
            Middle                                4.44                        8.00                 Pass
           Highest                                4.16




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 16 of 36


CCIS                                                                                     Report No: CCISE181101401

Test plots as follow:
   ® se    se en




   orte: 1e nov.zoe rsconse                                       orte: e nov.eoie receeas
                               Lowest channel                                                Middle channel




   orte: re nov.zoie. reiens

                               Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                          Project No.: CCISE1811014
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                         Page 17 of 36


                                                                               Report No: CCISE181101401

6.6 Band Edge
6.6.1 Conducted Emission Method
        Test Requirement:                FCC Part 15 C Section 15.247 (d)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           In any 100 kHz bandwidth outside the frequency band in which the
                                         spread spectrum intentional radiator is operating, the radio frequency
                                         power that is produced by the intentional radiator shall be at least 20 dB
                                         below that in the 100 kHz bandwidth within the band that contains the
                                         highest level of the desired power, based on either an RF conducted or a
                                         radiated measurement.
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 18 of 36


CCIS                                                                                       Report No: CCISE181101401

Test plots as follow:

 ® see   se uen




 outes 12 nov.zor8 insas—z0                                     dare: 12. mov .208 in ctri2e

                              Lowest channel                                                   Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                            Project No.: CCISE1811014
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                           Page 19 of 36


                                                                               Report No: CCISE181101401

6.6.2     Radiated Emission Method
      Test Requirement:                FCC Part15 C Section 15.209 and 15.205
      Test Method:                     ANSI C63.10: 2013 and KDB 558074
      Test Frequency Range:            960MHz to 1.240GHz
      Test site:                       Measurement Distance: 3m
      Receiver setup:                     Frequency           Detector         RBW         VBW            Remark
                                        960MHz-1GHz         Quasi-peak        120kHz      300kHz    Quasi-peak Value
                                                               Peak            1MHz        3MHz        Peak Value
                                         Above 1GHz
                                                               RMS             1MHz        3MHz       Average Value
      Limit:                                   Frequency              Limit (dBuV/m @3m)              Remark
                                            960MHz-1GHz                        54.00             Quasi-peak Value
                                                                               54.00               Average Value
                                              Above 1GHz
                                                                               74.00                Peak Value
      Test Procedure:                  1. The EUT was placed on the top of a rotating table 0.8m(below 1GHz)
                                            /1.5m(above 1GHz) above the groundat a 3 meter chamber.The table
                                            was rotated 360 degrees todetermine the position of the highest
                                            radiation.
                                       2. The EUT was set 3 meters away from the interference-receiving
                                            antenna, whichwas mounted on the top of a variable-height antenna
                                            tower.
                                       3. The antenna height is varied from one meter to four meters above the
                                            ground to determine the maximum value of the field strength. Both
                                            horizontal and vertical polarizations of the antenna are set to make the
                                            measurement.
                                       4. For each suspected emission, the EUT was arranged to its worst case
                                            and thenthe antenna was tuned to heights from 1 meter to 4 meters and
                                            the rotatablewas turned from 0 degrees to 360 degrees to find the
                                            maximum reading.
                                       5. The test-receiver system was set to Peak Detect Function and
                                            SpecifiedBandwidth with Maximum Hold Mode.
                                       6. If the emission level of the EUT in peak mode was 10dB lower than the
                                            limitspecified, then testing could be stopped and the peak values of the
                                            EUT wouldbe reported. Otherwise the emissions that did not have 10dB
                                            margin would bere-tested one by one using peak, quasi-peak or
                                            average method as specified andthen reported in a data sheet.
      Test setup:                      Below 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 20 of 36


                                                                          Report No: CCISE181101401

                                       Above 1GHz




      Test Instruments:                Refer to section 5.8 for details
      Test mode:                       Refer to section 5.3 for details
      Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                    Page 21 of 36


c c I s                                                                                Report No: CCISE181101401

Below 1GHz:

Product Name:               Lora Module                                Product Model:           E22—9001228
Test By:                    Zora                                       Test mode:              Tx mode

Test Channel:               Highest channel                            Polarization:           Vertical
Test Voltage:               AC 120V/60Hz                               Environment:            Temp: 24°C     Huni: §7%


     10flLeveI (dBuVim)                                                                                 Date: 2018—11—15

      90

      80

      70

      o8                                                                                         FCC PART15 CLASS B
      50

      40                                                           1

      30

      20

      10


           960       965                                                                                           1000
                                                        Frequency (MHz)


                             Readintenna          Cable Preamp                    Limit       Over
                   Freq     Level Factor           Loss Factor          Level      Line      Limit Remark

                     NHz      dBu¥       dB/m —        db _dB dBu¥/m dBu¥/m                       dB
       1         980.636     10.12     22.650      4.37T       0.00     3T.14     54.00 —16.86


Remark:
1.   Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1811014
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                        Page 22 of 36


c c I s                                                                                Report No: CCISE181101401



Product Name:                 Lora Module                         Product Model:          E22—9001228
Test By:                      Zora                                Test mode:              Tx mode
Test Channel:                 Highest channel                     Polarization:           Horizontal
Test Voltage:                 AC 120V/60Hz                        Environment:            Temp: 24°C           Huni: 57%


     100I.:-,“.rel (dBuVim)                                                                                Date: 2018—11—15


      90

      80

      70

      80                                                                                           FCC PART1S CLASS B
      50

      40                                                                                      1

      30

      20

      10

           960         965                                                                                             1000
                                                         Frequency (MHZ)

                               Read&ntenna      Cable Preamp                   Limit       Over
                   Freq       Level Factor       Loss Factor         Level      Line      Limit Remark

                     TEHz      dBu¥y    db/m        dB         dB dBu¥/m dBuT/m               db
       1         890.089       9.74    22.72     4.42       0.00 36.88 54.00 —17.12

Remark:
1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1811014
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                          Page 23 of 36


CCIS                                                                                   Report No: CCISE181101401

Above 1GHz:
Product Name:               Lora Module                               Product Model:           E22—9001228
Test By:                   Zora                                       Test mode:               Tx mode

Test Channel:               Highest channel                           Polarization:            Vertical
Test Voltage:              AC 120V/60Hz                               Environment:             Temp: 24°C          Huni: §7%


     mol.e\e!
           v (dBuVim)
                  J                                                                                      Date: ©2018—11—1
                                                                                                                2018—11—15


      90


      80                                                                                                FCC PART 15 (PK)
      70

      0                                                                                                 FCC PART 15 (AV)
      50                                                                                            1

      40

      30

      20

      10

       G1000    1020           1050                     1100                                            1200           1240
                                                        Frequency (MHz)
                           Readéntenna         Cable Preamp                  Limit       Over
                  Freq    Level Factor           Loss Factor       Level       Line     Limit Remark

                   NEz dBu¥y           dB/m        db _       dB dBu¥/n dBu¥/m              dB ~               ~

       1    1191.879       18.26      24.29      3.30      0.00    45.85      74.00 —28.15 Peak
       20   1191.879        9.85      24.29      3.30      0.00    37.44      54.00 —16.56 Average



Remark:
1.   Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1811014
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                           Page 24 of 36


CCIS                                                                                   Report No: CCISE181101401



Product Name:                Lora Module                            Product Model:        E22—9001228
Test By:                     Zora                                   Test mode:            Tx mode
Test Channel:                Highest channel                        Polarization:         Horizontal
Test Voltage:                AC 120V/60Hz                           Environment:          Temp: 24°C            Huni: 57%


           Level (dBu\Vim)                                                                                 Date: 2018—11—15
     100

      90

      °0                                                                                               FCC PART 15 (PK)
      70

      80                                                                                               FCC PART 15 (AV)
      50                                                                       1

      40

      30

      20

      10

           1000   1020              1050                    1100                                       1200            1240
                                                            Frequency (MHz)

                              Read&ntenna           Cable Preamp              Limit     Over
                   Freq      Level Factor             Loss Factor   Level      Line    Limit Remark

                    NHz       dBu¥         dB/m _      dB      d6 dBu¥/m dBu¥/m            dB
      1.      1144.394       19.07     24.13         3.24    0.00   46.44     74.00 —27.56 Peak
      20      1144.394       10.23     2M.13         3.24    0.00   37.60     54.00 —16.40 Average


Remark:
1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1811014
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                           Page 25 of 36


                                                                               Report No: CCISE181101401

6.7     Spurious Emission
6.7.1     Conducted Emission Method
        Test Requirement:                FCC Part 15 C Section 15.247 (d)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           In any 100 kHz bandwidth outside the frequency band in which the
                                         spread spectrum intentional radiator is operating, the radio frequency
                                         power that is produced by the intentional radiator shall be at least 20 dB
                                         below that in the 100 kHz bandwidth within the band that contains the
                                         highest level of the desired power, based on either an RF conducted or a
                                         radiated measurement.
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 26 of 36


CCIS                                                                                    Report No: CCISE181101401

Test plot as follows:
                               Lowest channel                                               Middle channel
   *w e                 ces                      B                ® wl
  BA




   onte: 1e nov.aoe recoicer                                      orte: renov.eoie receee

                               30OMHz~25GHz                                                 30OMHz~25GHz


                               Highest channel




   orte: 1e nov.zoe zsmcs

                               30MHz~25GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                         Project No.: CCISE1811014
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                        Page 27 of 36


                                                                                Report No: CCISE181101401

 6.7.2 Radiated Emission Method
        Test Requirement:                FCC Part 15 C Section 15.209 and 15.205
        Test Method:                     ANSI C63.10:2013
        Test Frequency Range:            9kHz to 25GHz
        Test Distance:                   3m
        Receiver setup:                    Frequency       Detector         RBW        VBW             Remark
                                          30MHz-1GHz      Quasi-peak      120KHz     300KHz       Quasi-peak Value
                                                            Peak           1MHz        3MHz           Peak Value
                                          Above 1GHz
                                                            RMS            1MHz        3MHz         Average Value
        Limit:                                  Frequency           Limit (dBuV/m @3m)              Remark
                                              30MHz-88MHz                    40.0               Quasi-peak Value
                                             88MHz-216MHz                    43.5               Quasi-peak Value
                                            216MHz-960MHz                    46.0               Quasi-peak Value
                                              960MHz-1GHz                    54.0               Quasi-peak Value
                                                                             54.0                Average Value
                                               Above 1GHz
                                                                             74.0                 Peak Value
        Test Procedure:                  1.   The EUT was placed on the top of a rotating table 0.8m(below
                                              1GHz)/1.5m(above 1GHz) above the ground at a 3 meter camber.
                                              The table was rotated 360 degrees to determine the position of the
                                              highest radiation.
                                         2.   The EUT was set 3 meters away from the interference-receiving
                                              antenna, which was mounted on the top of a variable-height antenna
                                              tower.
                                         3.   The antenna height is varied from one meter to four meters above
                                              the ground to determine the maximum value of the field strength.
                                              Both horizontal and vertical polarizations of the antenna are set to
                                              make the measurement.
                                         4.   For each suspected emission, the EUT was arranged to its worst
                                              case and then the antenna was tuned to heights from 1 meter to 4
                                              meters and the rota table was turned from 0 degrees to 360 degrees
                                              to find the maximum reading.
                                         5.   The test-receiver system was set to Peak Detect Function and
                                              Specified Bandwidth with Maximum Hold Mode.
                                         6.   If the emission level of the EUT in peak mode was 10 dB lower than
                                              the limit specified, then testing could be stopped and the peak values
                                              of the EUT would be reported. Otherwise the emissions that did not
                                              have 10 dB margin would be re-tested one by one using peak, quasi-
                                              peak or average method as specified and then reported in a data
                                              sheet.
        Test setup:                      Below 1GHz




                                         Above 1GHz
Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 28 of 36


                                                                            Report No: CCISE181101401




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed
        Remark:                          1. Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and
                                            found the Y-axis is the worst case.
                                         2. 9 kHz to 30MHz is too low, so only shows the data of above 30MHz
                                            in this report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                         Page 29 of 36


c c I s                                                                                Report No: CCISE181101401

Measurement Data (worst case):
Below 1GHz:

Product Name:               Lora Module                               Product Model:             E22—9001228
Test By:                    Zora                                      Test mode:                 Tx mode

Test Frequency:             30 MHz ~ 1 GHz                            Polarization:              Vertical

Test Voltage:               AC 120V/60Hz                              Environment:               Temp: 24°C       Huni: 57%


     molevel (dBuVim)                                                                                   Date: 2018—11—15

      90                                                                         Fundamental wave

      80

      70

      60
                                                                                                  FCC PART15 CLASYB
      50

     40
      30

      20
      10


           30          50                     100                   200                           500                1000
                                                           Frequency (MHz)

                             Readéntenna       Cable Preamnp                  Limit      Over
                  Freq      Level Factor        Loss Factor          Level     Line     Limit Remark

                    NHz      dBu¥Y     dB/m           dB        dB dBu¥/m dBu¥/m —dB —
       1         T1.832     22.02     5.91          1.56     0.00    32.49    40.00     —7.51    QP
       2         96.099     24.72    11.06          2.00     0.00    37.78    43.50     —65.72   QP
       3        143.830     24.29     8.30          2.44     0.00    35.03    43.50     —8.47    QP
       4        191.745     20.48    11.25          2.81     0.00    34.54    43.50     —8.96    qP
       5        612.064     18.31    19.35          3.92     0.00    41.58    46.00     —4.42    QP
       6        Ti1.674     18.89    20.09          4.22     0.00    43.20    46.00     —2.80    QP


Remark:
1.   Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                          Project No.: CCISE1811014
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                         Page 30 of 36


CCIS                                                                                    Report No: CCISE181101401



Product Name:              Lora Module                               Product Model:             E22—9001228
Test By:                   Zora                                      Test mode:                Tx mode

Test Frequency:            30 MHz ~ 1 GHz                            Polarization:              Horizontal

Test Voltage:              AC 120V/60Hz                              Environment:              Temp: 24°C          Huni: 57%

                   J
     moLeveI (dBuVim)                                                                                      Date:
                                                                                                            ate 2018—11—15


      90                                                                           Fundamental wave

      80                                                                                        \

      70


      69                                                                                          FCC PART1S CLASYB
      50

      40

      30

      20

      10

           30                                 100                   200                           500                  1000
                                                         Frequency (MHz)

                            ReadiAntenna        Cable Preamp                   Limit      Over
                  Freq     Level Factor           Loss Factor        Level       Line    Limit Remark

            """"NBz dBu¥y dB/m —                    db _ dB dBu¥/m dBu¥/m —dB —==—
      1          95.762    25.83      11.00       2.01      0.00     38.84     43.50     —4.66    QP
      2         143.830    28.57       8.30       2.44      0.00     39.31     43.50     —4.19    QP
      3         167.824    27.72       9.34       2.64      0.00     39.70     43.50     —3.80    QP
      4         191.745    26.23      11.25       2.81      0.00     40.29     43.50     —3.21    QP
      5         287.990    24.01      13.53       2.91      0.00     40.45     46.00     —5.55    qP
      6         668.142    19.27      19.80       3.97      0.00     43.04     46.00     —2.96    qP


Remark:
1. Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1811014
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                          Page 31 of 36


                                                                                    Report No: CCISE181101401

Above 1GHz:
                                             Test channel: Lowest channel
                                                 Detector: Peak Value
                  Read       Antenna        Cable       Preamp
 Frequency                                                            Level       Limit Line      Over
                  Level       Factor        Loss         Factor                                              Polarization
   (MHz)                                                            (dBuV/m)      (dBuV/m)      Limit (dB)
                 (dBuV)       (dB/m)         (dB)         (dB)
  1806.00         45.01        25.98        4.12       41.22       33.89            74.00         -40.11      Vertical
  1806.00         44.77        25.98        4.12       41.22       33.65            74.00         -40.35     Horizontal
                                                Detector: Average Value
                  Read       Antenna        Cable     Preamp
 Frequency                                                         Level          Limit Line      Over
                  Level       Factor        Loss       Factor                                                Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)      Limit (dB)
                 (dBuV)       (dB/m)         (dB)       (dB)
  1806.00         39.62        25.98        4.12       41.22       28.50            54.00         -25.50      Vertical
  1806.00         38.21        25.98        4.12       41.22       28.23            54.00         -25.77     Horizontal



                                              Test channel: Middle channel
                                                  Detector: Peak Value
                  Read       Antenna        Cable     Preamp
 Frequency                                                          Level         Limit Line      Over
                  Level       Factor        Loss       Factor                                                Polarization
   (MHz)                                                          (dBuV/m)        (dBuV/m)      Limit (dB)
                 (dBuV)       (dB/m)         (dB)        (dB)
  1830.00         45.21        26.02        4.15        41.27       34.11           74.00         -39.89      Vertical
  1830.00         44.78        26.02        4.15        41.27       33.68           74.00         -40.32     Horizontal
                                                Detector: Average Value
                  Read       Antenna        Cable     Preamp
 Frequency                                                          Level         Limit Line      Over
                  Level       Factor        Loss       Factor                                                Polarization
   (MHz)                                                          (dBuV/m)        (dBuV/m)      Limit (dB)
                 (dBuV)       (dB/m)         (dB)        (dB)
  1830.00         39.68        26.02        4.15        41.27       28.58           54.00         -25.42      Vertical
  1830.00         38.57        26.02        4.15        41.27       28.23           54.00         -25.77     Horizontal



                                             Test channel: Highest channel
                                                  Detector: Peak Value
                  Read       Antenna        Cable     Preamp
 Frequency                                                         Level          Limit Line      Over
                  Level       Factor        Loss       Factor                                                Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)      Limit (dB)
                 (dBuV)       (dB/m)         (dB)        (dB)
  1854.00         45.36        26.08        4.17        41.32      40.33            74.00         -33.67      Vertical
  1854.00         44.80        26.08        4.17        41.32      43.09            74.00         -30.91     Horizontal
                                                Detector: Average Value
                  Read       Antenna        Cable     Preamp
 Frequency                                                         Level          Limit Line      Over
                  Level       Factor        Loss       Factor                                                Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)      Limit (dB)
                 (dBuV)       (dB/m)         (dB)        (dB)
  1854.00         39.56        26.08        4.17        41.32      37.44            54.00         -16.56      Vertical
  1854.00         38.26        26.08        4.17        41.32      28.23            54.00         -25.77     Horizontal
 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
 2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE1811014
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                    Page 32 of 36



Document Created: 2018-12-06 09:49:31
Document Modified: 2018-12-06 09:49:31

© 2025 FCC.report