Test report

FCC ID: 2ALPH-E19

Test Report

Download: PDF
FCCID_3881753

                         Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                       Report No: CCISE180111101

         1        Cover Page
                                          FCC REPORT
                                                          (RFID)

Applicant:                             Chengdu Ebyte Electronic Technology Co., Ltd.
                                       innovation Center D347, 4#XI-XIN road, High-tech district(west),
Address of Applicant:
                                       Chengdu, Sichuan, China
Equipment Under Test (EUT)

    Product Name:                      Wireless transceiver module

    Model No.:                         E19

    Trade mark:                        EBYTE

FCC ID:                                2ALPH-E19

Applicable standards:                  FCC CFR Title 47 Part 15 Subpart C Section 15.247

Date of sample receipt:                01 Feb., 2018

Date of Test:                          01 Feb., to 24 May., 2018

Date of report issued:                 25 May., 2018

Test Result:                           PASS *

*   In the configuration tested, the EUT complied with the standards specified above.




Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate
to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer
should ensure that all products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than
that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted
to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested
and such sample(s) are retained for 90 days only.


                                                                                 Report No: CCISE180111101


2      Version
      Version No.                        Date                                    Description
            00                     25 May., 2018                                   Original




    Tested by:                                                           Date:          25 May., 2018

                                        Test Engineer


    Reviewed by:                                                         Date:          25 May., 2018

                                      Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 2 of 38


                                                                                                                       Report No: CCISE180111101

3         Contents
                                                                                                                                                                         Page
1       COVER PAGE ....................................................................................................................................................... 1
2       VERSION ............................................................................................................................................................... 2
3       CONTENTS ........................................................................................................................................................... 3
4       TEST SUMMARY .................................................................................................................................................. 4
5       GENERAL INFORMATION .................................................................................................................................. 5
    5.1         CLIENT INFORMATION ............................................................................................................................................ 5
    5.2         GENERAL DESCRIPTION OF E.U.T........................................................................................................................ 5
    5.3         TEST ENVIRONMENT AND TEST MODE ................................................................................................................... 6
    5.4         DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 6
    5.5         MEASUREMENT UNCERTAINTY.............................................................................................................................. 6
    5.6         LABORATORY FACILITY.......................................................................................................................................... 6
    5.7         LABORATORY LOCATION ....................................................................................................................................... 7
    5.8         TEST INSTRUMENTS LIST ....................................................................................................................................... 7
6       TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1     ANTENNA REQUIREMENT: ...................................................................................................................................... 8
    6.2     CONDUCTED EMISSION ......................................................................................................................................... 9
    6.3     CONDUCTED OUTPUT POWER ............................................................................................................................ 12
    6.4     OCCUPY BANDWIDTH .......................................................................................................................................... 14
    6.5     POWER SPECTRAL DENSITY ............................................................................................................................... 16
    6.6     BAND EDGE ......................................................................................................................................................... 18
       6.6.1 Conducted Emission Method...................................................................................................................... 18
       6.6.2 Radiated Emission Method ......................................................................................................................... 20
    6.7     SPURIOUS EMISSION ........................................................................................................................................... 26
       6.7.1 Conducted Emission Method...................................................................................................................... 26
       6.7.2 Radiated Emission Method ......................................................................................................................... 28
7       TEST SETUP PHOTO ........................................................................................................................................ 35
8       EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 37




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                             Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                      Page 3 of 38


                                                                                      Report No: CCISE180111101

 4      Test Summary
                       Test Items                                Section in CFR 47                  Result
                  Antenna requirement                             15.203/15.247 (c)                  Pass
         AC Power Line Conducted Emission                                 15.207                     Pass
            Conducted Peak Output Power                              15.247 (b)(3)                   Pass
                6dB Emission Bandwidth                               15.247 (a)(2)                   Pass
                 Power Spectral Density                                  15.247 (e)                  Pass
                       Band Edge                                         15.247(d)                   Pass
     Conducted and radiated Spurious Emission                       15.205/15.209                    Pass
     Remark:
     Pass: Meet the requirement. N/A: Not Applicable for Non-adaptive equipment.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 4 of 38


c c I s                                                                        Report No: CCISE180111101

5           General Information
5.1 Client Information
            Applicant:                   Chengdu Ebyte Electronic Technology Co., Ltd.
            Address:                     innovation Center D347, 4#XI—XIN road, High—tech district(west),
                                         Chengdu, Sichuan, China
            Manufacturer/Factory:        Chengdu Ebyte Electronic Technology Co., Ltd.
            Address:                     innovation Center D347,4#XI—XIN road, High—tech district(west),
                                         Chengdu, Sichuan, China


5.2 General Description of E.U.T.
            Product Name:                 Wireless transceiver module
            Madel No.:                    E19
            Operation Frequency:          903—927 MHz
            Channel numbers:              25
            Channel separation:           1 MHz
            Modulation technology:        Lora
            Antenna Type:                 External Antenna
            Antenna gain:                 2 cBi
            Power supply:                 DC 5V



    Operation Frequency each of channel
    Channel              Frequency     Channel             Frequency        Channel             Frequency
        0                903MHz            10               913MHz             20                923MHz
        1                904MHz            11               914MHz             21                924MHz
        2                905MHz            12               915MHz             22                925MHz
        3                906MHz            13               916MHz             23                926GMHz
        4                907MHz            14               917MHz             24                927MHz
        5                908MHz            15               918MHz
        6                909MHz            16               919MHz
        7                910MHz            17               920MHz
        8                911MHz            18               921MHz
        9                912MHz            19               922MHz
    Note:
    In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the
    middle frequency, and the highest frequency of channel were selected to perform the test. Channel No. 0,
    12 & 24 were selected as Lowest, Middle and Highest channel.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1801111
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 5 of 38


                                                                              Report No: CCISE180111101

5.3 Test environment and test mode
 Operating Environment:
     Temperature:                      24.0 C
     Humidity:                         54 % RH
     Atmospheric Pressure:             1010 mbar
 Test mode:
     Transmitting mode                 Keep the EUT in continuous transmitting with modulation
 The sample was placed 0.8m (below 1GHz)/1.5m (above 1GHz) above the ground plane of 3m chamber.
 Measurements in both horizontal and vertical polarities were performed. During the test, each emission was
 maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3
 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting
 cables, rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertical
 polarizations. The emissions worst-case are shown in Test Results of the following pages. Duty cycle setting
 during the transmission is 100% with maximum power setting for all modulations.

5.4 Description of Support Units
      Manufacturer                Description                 Model               S/N            FCC ID/DoC
       LENOVO                       Laptop                    SL510             2847A65             DoC
        EBYTE                      Test suite                 E25 D1              N/A               N/A
       Sunshiny                     Adapter               XS-1201000SCN           N/A               N/A

5.5 Measurement Uncertainty
                    Parameters                                            Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                    ±2.22 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                    ±2.76 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                   ±4.28 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                     ±5.72 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                    ±2.88 dB (k=2)

5.6 Laboratory Facility
       The test facility is recognized, certified, or accredited by the following organizations:
        FCC - Registration No.: 727551
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
       (Federal Communications Commission). The Registration No. is 727551.
        IC - Registration No.: 10106A-1
       The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
       with Registration No.: 10106A-1.
        CNAS - Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.
        A2LA - Registration No.: 4346.01
       This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
       17025:2005 General requirements for the competence of testing and calibration laboratories. The test
       scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 6 of 38


                                                                                   Report No: CCISE180111101

5.7 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bao’an District, Shenzhen, Guangdong, China
        Tel: +86-755-23118282, Fax: +86-755-23116366
        Email: info@ccis-cb.com, Website: http://www.ccis-cb.com

5.8 Test Instruments list
 Radiated Emission:
                                                                                         Cal. Date    Cal. Due date
    Test Equipment             Manufacturer            Model No.          Serial No.
                                                                                        (mm-dd-yy)     (mm-dd-yy)
        3m SAC                   SAEMC                9m*6m*6m              966         07-22-2017    07-21-2020
  BiConiLog Antenna         SCHWARZBECK                VULB9163             497         03-16-2018    03-15-2019
     Horn Antenna           SCHWARZBECK               BBHA9120D             916         03-16-2018    03-15-2019
   EMI Test Software             AUDIX                     E3             6.110919b         N/A          N/A
      Pre-amplifier                HP                    8447D           2944A09358     03-07-2018    03-06-2019
      Pre-amplifier                CD                  PAP-1G18            11804        03-07-2018    03-06-2019
   Spectrum analyzer        Rohde & Schwarz              FSP30             101454       03-07-2018    03-06-2019
   EMI Test Receiver        Rohde & Schwarz             ESRP7              101070       03-07-2018    03-06-2019
   Simulated Station             Anritsu               MT8820C           6201026545     03-07-2018    03-06-2019
         Cable                   ZDECL              Z108-NJ-NJ-81         1608458       03-07-2018    03-06-2019
         Cable                MICRO-COAX              MFR64639            K10742-5      03-07-2018    03-06-2019
         Cable                  SUHNER              SUCOFLEX100          58193/4PE      03-07-2018    03-06-2019



 Conducted Emission:
                                                                                         Cal. Date    Cal. Due date
    Test Equipment            Manufacturer             Model No.          Serial No.
                                                                                        (mm-dd-yy)     (mm-dd-yy)
   EMI Test Receiver        Rohde & Schwarz              ESCI              101189       03-07-2018    03-06-2019
     Pulse Limiter          SCHWARZBECK              OSRAM 2306             9731        03-07-2018    03-06-2019
         LISN                    CHASE                 MN2050D              1447        03-19-2018    03-18-2019
         LISN               Rohde & Schwarz            ESH3-Z5           8438621/010    07-21-2017    07-20-2018
         Cable                     HP                   10503A              N/A         03-07-2018    03-06-2019
   EMI Test Software             AUDIX                     E3             6.110919b        N/A            N/A




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 7 of 38


                                                                          Report No: CCISE180111101

6      Test results and Measurement Data
6.1 Antenna requirement:
        Standard requirement:          FCC Part 15 C Section 15.203 /247(c)
        15.203 requirement:
        An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
        responsible party shall be used with the device. The use of a permanently attached antenna or of an
        antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
        so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
        electrical connector is prohibited.
        15.247(c) (1)(i) requirement:
        (i) Systems operating in the 2400-2483.5 MHz band that is used exclusively for fixed. Point-to-point
        operations may employ transmitting antennas with directional gain greater than 6dBi provided the
        maximum conducted output power of the intentional radiator is reduced by 1 dB for every 3 dB that the
        directional gain of the antenna exceeds 6dBi.
       E.U.T Antenna:
       The antenna is an External antenna which cannot replace by end-user, the best-case gain of the
       antenna is 2 dBi.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                         Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                          Page 8 of 38


                                                                              Report No: CCISE180111101


6.2 Conducted Emission
       Test Requirement:                FCC Part 15 C Section 15.207
       Test Method:                     ANSI C63.10: 2013
       Test Frequency Range:            150 kHz to 30 MHz
       Class / Severity:                Class B                 Class B
       Receiver setup:                  RBW=9kHz, VBW=30kHz
       Limit:                                                                         Limit (dBuV)
                                        Frequency range (MHz)
                                                                        Quasi-peak                  Average
                                                0.15-0.5                  66 to 56*                 56 to 46*
                                                  0.5-5                      56                        46
                                                  5-30                       60                        50
                                        * Decreases with the logarithm of the frequency.
       Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                            line impedance stabilization network (L.I.S.N.), which provides a
                                            50ohm/50uH coupling impedance for the measuring equipment.
                                        2. The peripheral devices are also connected to the main power through
                                            a LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                            termination. (Please refer to the block diagram of the test setup and
                                            photographs).
                                        3. Both sides of A.C. line are checked for maximum conducted
                                            interference. In order to find the maximum emission, the relative
                                            positions of equipment and all of the interface cables must be changed
                                            according to ANSI C63.4: 2014 on conducted measurement.
       Test setup:




       Test Instruments:                Refer to section 5.8 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 9 of 38


                                                                            Report No: CCISE180111101

Measurement Data:
Test Phase: Neutral




Notes:
1. An initial pre-scan was performed on the live and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 10 of 38


                                                                             Report No: CCISE180111101


Test Phase: Line




Notes:
1. An initial pre-scan was performed on the live and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 11 of 38


                                                                                Report No: CCISE180111101

6.3 Conducted Output Power
        Test Requirement:                FCC Part 15 C Section 15.247 (b)(3)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           30dBm
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data:
                                Maximum Conducted Output Power
          Test CH                                                              Limit(dBm)              Result
                                           (dBm)
           Lowest                                 14.02
           Middle                                 12.58                          30.00                  Pass
          Highest                                 11.81




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 12 of 38


                                                                                                                                                  Report No: CCISE180111101

Test plot as follows:
                                                              * RBW   1 MHz   Marker 1 [T1 ]                                                                       * RBW   1 MHz   Marker 1 [T1 ]
                                                              * VBW   3 MHz              14.02 dBm                                                                 * VBW   3 MHz              12.58 dBm
               Ref    27 dBm              * Att   30 dB        SWT 2.5 ms        903.140000000 MHz                  Ref    27 dBm              * Att   30 dB        SWT 2.5 ms        914.920000000 MHz

                     Offset    7 dB                                                                                       Offset    7 dB

               20                                                                                                   20
                                                              1                                      A                                                                                                    A
                                                                                                                                                               1

      1 RM *                                                                                               1 RM *
               10                                                                                                   10
      MAXH                                                                                                 MAXH
                                                                                                     LVL                                                                                                  LVL

               0                                                                                                    0



               -10                                                                                                  -10



               -20                                                                                                  -20



               -30                                                                                   3DB            -30                                                                                   3DB
                                                                                                     AC                                                                                                   AC



               -40                                                                                                  -40



               -50                                                                                                  -50



               -60                                                                                                  -60



               -70                                                                                                  -70

               Center 903 MHz                         500 kHz/                          Span 5 MHz                  Center 915 MHz                         500 kHz/                          Span 5 MHz




      Date: 23.MAY.2018               14:43:55                                                             Date: 23.MAY.2018               15:18:42




                                              Lowest channel                                                                                       Middle channel


                                                              * RBW   1 MHz   Marker 1 [T1 ]
                                                              * VBW   3 MHz              11.81 dBm
               Ref    27 dBm              * Att   30 dB        SWT 2.5 ms        926.840000000 MHz

                     Offset    7 dB

               20
                                                                                                     A
                                                          1
      1 RM *
               10
      MAXH
                                                                                                     LVL

               0



               -10



               -20



               -30                                                                                   3DB




               -40



               -50



               -60



               -70

               Center 927 MHz                         500 kHz/                          Span 5 MHz




      Date: 23.MAY.2018               15:48:18




                                             Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                                                                   Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                                                                 Page 13 of 38


                                                                                Report No: CCISE180111101

6.4 Occupy Bandwidth
        Test Requirement:                FCC Part 15 C Section 15.247 (a)(2)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           >500kHz
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data:
         Test CH               6dB Emission Bandwidth (MHz)                 Limit(kHz)            Result
          Lowest                              0.780
          Middle                              0.772                           >500                 Pass
         Highest                              0.772

         Test CH               99% Occupy Bandwidth (MHz)                   Limit(kHz)            Result
          Lowest                              0.792
          Middle                              0.808                            N/A                  N/A
         Highest                              0.796




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 14 of 38


CCIS                                                                                 Report No: CCISE180111101

Test plot as follows:
                                   6dB EBW                                                  99% OBW

     ®n-e    «+m




     deses rseecoons risnne                                              noacres uusies

                             Lowest channel                                           Lowest channel




     dees reseecoons. iscuoice                                           mesnres isauie

                                 Middle channel                                           Middle channel




     dees reseecoons. iscanise                                           ie oo iscescoe

                             Highest channel                                          Highest channel


Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                       Project No.: CCISE1801111
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                      Page 15 of 38


                                                                               Report No: CCISE180111101

6.5 Power Spectral Density
        Test Requirement:                FCC Part 15 C Section 15.247 (e)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           8 dBm
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data:
           Test CH                 Power Spectral Density (dBm)             Limit(dBm)             Result
            Lowest                                5.44
            Middle                                3.85                        8.00                 Pass
           Highest                                2.79




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 16 of 38


CCIS                                                                                 Report No: CCISE180111101

Test plots as follow:

     @ m




     daces aneecoons vesascon                                            rsanres isaren

                            Lowest channel                                                Middle channel




     orces rssecons. isnn

                            Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                       Project No.: CCISE1801111
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                      Page 17 of 38


                                                                               Report No: CCISE180111101

6.6 Band Edge
6.6.1 Conducted Emission Method
        Test Requirement:                FCC Part 15 C Section 15.247 (d)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           In any 100 kHz bandwidth outside the frequency band in which the
                                         spread spectrum intentional radiator is operating, the radio frequency
                                         power that is produced by the intentional radiator shall be at least 20 dB
                                         below that in the 100 kHz bandwidth within the band that contains the
                                         highest level of the desired power, based on either an RF conducted or a
                                         radiated measurement.
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 18 of 38


c c I s                                                                                 Report No: CCISE180111101

Test plots as follow:


     ®n-e   «o




     dace: rn nsm iss                                               daces rsercoos isconis


                      Lowest channel                                                     Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1801111
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 19 of 38


                                                                               Report No: CCISE180111101

6.6.2     Radiated Emission Method
      Test Requirement:                FCC Part15 C Section 15.209 and 15.205
      Test Method:                     ANSI C63.10: 2013 and KDB 558074
      Test Frequency Range:            960MHz to 1.240GHz
      Test site:                       Measurement Distance: 3m
      Receiver setup:                     Frequency           Detector         RBW         VBW            Remark
                                        960MHz-1GHz         Quasi-peak        120kHz      300kHz    Quasi-peak Value
                                                               Peak            1MHz        3MHz        Peak Value
                                         Above 1GHz
                                                               RMS             1MHz        3MHz       Average Value
      Limit:                                   Frequency              Limit (dBuV/m @3m)              Remark
                                            960MHz-1GHz                        54.00             Quasi-peak Value
                                                                               54.00               Average Value
                                              Above 1GHz
                                                                               74.00                Peak Value
      Test Procedure:                  1. The EUT was placed on the top of a rotating table 0.8m(below 1GHz)
                                            /1.5m(above 1GHz) above the groundat a 3 meter chamber.The table
                                            was rotated 360 degrees todetermine the position of the highest
                                            radiation.
                                       2. The EUT was set 3 meters away from the interference-receiving
                                            antenna, whichwas mounted on the top of a variable-height antenna
                                            tower.
                                       3. The antenna height is varied from one meter to four meters above the
                                            ground to determine the maximum value of the field strength. Both
                                            horizontal and vertical polarizations of the antenna are set to make the
                                            measurement.
                                       4. For each suspected emission, the EUT was arranged to its worst case
                                            and thenthe antenna was tuned to heights from 1 meter to 4 meters and
                                            the rotatablewas turned from 0 degrees to 360 degrees to find the
                                            maximum reading.
                                       5. The test-receiver system was set to Peak Detect Function and
                                            SpecifiedBandwidth with Maximum Hold Mode.
                                       6. If the emission level of the EUT in peak mode was 10dB lower than the
                                            limitspecified, then testing could be stopped and the peak values of the
                                            EUT wouldbe reported. Otherwise the emissions that did not have 10dB
                                            margin would bere-tested one by one using peak, quasi-peak or
                                            average method as specified andthen reported in a data sheet.
      Test setup:                      Below 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 20 of 38


                                                                          Report No: CCISE180111101

                                       Above 1GHz




      Test Instruments:                Refer to section 5.8 for details
      Test mode:                       Refer to section 5.3 for details
      Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                    Page 21 of 38


                                                                                     Report No: CCISE180111101

Below 1GHz:
Test channel: Highest channel
Test Polarization: Horizontal




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 22 of 38


                                                                                     Report No: CCISE180111101


Test Polarization: Vertical




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 23 of 38


                                                                                     Report No: CCISE180111101

Above 1GHz:
Test channel: Highest channel
Test Polarization: Horizontal




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 24 of 38


                                                                                     Report No: CCISE180111101


Test Polarization: Vertical




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                     Page 25 of 38


                                                                               Report No: CCISE180111101

6.7     Spurious Emission
6.7.1     Conducted Emission Method
        Test Requirement:                FCC Part 15 C Section 15.247 (d)
        Test Method:                     ANSI C63.10:2013 and KDB558074
        Limit:                           In any 100 kHz bandwidth outside the frequency band in which the
                                         spread spectrum intentional radiator is operating, the radio frequency
                                         power that is produced by the intentional radiator shall be at least 20 dB
                                         below that in the 100 kHz bandwidth within the band that contains the
                                         highest level of the desired power, based on either an RF conducted or a
                                         radiated measurement.
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 26 of 38


CCIS                                                                             Report No: CCISE180111101

Test plot as follows:
                       Lowest channel                                                 Middle channel

     ®n-e   «o




     trce rsenoms iscrir                                                 io zns ssm

                       30OMHz~25GHz                                               30OMHz~25GHz


                       Highest channel




     tiee rrsenons. iscc

                       30MHz~25GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                   Project No.: CCISE1801111
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                  Page 27 of 38


                                                                                Report No: CCISE180111101

 6.7.2 Radiated Emission Method
        Test Requirement:                FCC Part 15 C Section 15.209 and 15.205
        Test Method:                     ANSI C63.10:2013
        Test Frequency Range:            9kHz to 25GHz
        Test Distance:                   3m
        Receiver setup:                    Frequency       Detector         RBW        VBW             Remark
                                          30MHz-1GHz      Quasi-peak      120KHz     300KHz       Quasi-peak Value
                                                            Peak           1MHz        3MHz           Peak Value
                                          Above 1GHz
                                                            RMS            1MHz        3MHz         Average Value
        Limit:                                  Frequency           Limit (dBuV/m @3m)              Remark
                                              30MHz-88MHz                    40.0               Quasi-peak Value
                                             88MHz-216MHz                    43.5               Quasi-peak Value
                                            216MHz-960MHz                    46.0               Quasi-peak Value
                                              960MHz-1GHz                    54.0               Quasi-peak Value
                                                                             54.0                Average Value
                                               Above 1GHz
                                                                             74.0                 Peak Value
        Test Procedure:                  1.   The EUT was placed on the top of a rotating table 0.8m(below
                                              1GHz)/1.5m(above 1GHz) above the ground at a 3 meter camber.
                                              The table was rotated 360 degrees to determine the position of the
                                              highest radiation.
                                         2.   The EUT was set 3 meters away from the interference-receiving
                                              antenna, which was mounted on the top of a variable-height antenna
                                              tower.
                                         3.   The antenna height is varied from one meter to four meters above
                                              the ground to determine the maximum value of the field strength.
                                              Both horizontal and vertical polarizations of the antenna are set to
                                              make the measurement.
                                         4.   For each suspected emission, the EUT was arranged to its worst
                                              case and then the antenna was tuned to heights from 1 meter to 4
                                              meters and the rota table was turned from 0 degrees to 360 degrees
                                              to find the maximum reading.
                                         5.   The test-receiver system was set to Peak Detect Function and
                                              Specified Bandwidth with Maximum Hold Mode.
                                         6.   If the emission level of the EUT in peak mode was 10 dB lower than
                                              the limit specified, then testing could be stopped and the peak values
                                              of the EUT would be reported. Otherwise the emissions that did not
                                              have 10 dB margin would be re-tested one by one using peak, quasi-
                                              peak or average method as specified and then reported in a data
                                              sheet.
        Test setup:                      Below 1GHz




                                         Above 1GHz
Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 28 of 38


                                                                            Report No: CCISE180111101




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed
        Remark:                          1. Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and
                                            found the Y-axis is the worst case.
                                         2. 9 kHz to 30MHz is too low, so only shows the data of above 30MHz
                                            in this report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                         Page 29 of 38


                                                                                    Report No: CCISE180111101

Measurement Data (worst case):
Below 1GHz:
Test Polarization: Horizontal




                                                                                     Fundamental wave




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                    Page 30 of 38


                                                                                    Report No: CCISE180111101


Test Polarization: Vertical




                                                                                    Fundamental wave




Remark:
1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                    Page 31 of 38


                                                                                  Report No: CCISE180111101

Above 1GHz:
                                             Test channel: Lowest channel
                                                 Detector: Peak Value
                  Read       Antenna        Cable       Preamp
 Frequency                                                            Level      Limit Line     Over
                  Level       Factor        Loss         Factor                                            Polarization
   (MHz)                                                            (dBuV/m)     (dBuV/m)     Limit (dB)
                 (dBuV)       (dB/m)         (dB)         (dB)
  1806.00         61.01        25.05         4.13        41.25           48.94     74.00       -25.06        Vertical
  2709.00         52.35        26.35         5.07        41.74           42.03     74.00       -31.97        Vertical
  3612.00         48.43        27.72         5.92        41.58           40.49     74.00       -33.51        Vertical
  4515.00         45.31        29.47         6.84        42.08           39.54     74.00       -34.46        Vertical
  5418.00         48.90        30.54         7.16        41.85           44.75     74.00       -29.25        Vertical



  1806.00         63.57        25.10         4.12        41.21           51.58     74.00       -22.42      Horizontal
  2709.00         58.62        26.35         5.07        41.74           48.30     74.00       -25.70      Horizontal
  3612.00         55.76        27.72         5.92        41.58           47.82     74.00       -26.18      Horizontal
  4515.00         45.06        29.47         6.84        42.08           39.29     74.00       -34.71      Horizontal
  5418.00         49.49        30.54         7.18        41.85           45.36     74.00       -28.64      Horizontal




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                  Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                  Page 32 of 38


                                                                                  Report No: CCISE180111101

                                              Test channel: Middle channel
                                                  Detector: Peak Value
                  Read       Antenna        Cable     Preamp
 Frequency                                                          Level        Limit Line     Over
                  Level       Factor        Loss       Factor                                              Polarization
   (MHz)                                                          (dBuV/m)       (dBuV/m)     Limit (dB)
                 (dBuV)       (dB/m)         (dB)       (dB)
  1830.00         61.01        25.05        4.13       41.25        48.94          74.00       -25.06        Vertical
  2745.00         52.35        26.35        5.07       41.74        42.03          74.00       -31.97        Vertical
  3660.00         48.43        27.72        5.92       41.58        40.49          74.00       -33.51        Vertical
  4575.00         45.31        29.47        6.84       42.08        39.54          74.00       -34.46        Vertical
  5490.00         48.90        30.54        7.16       41.85        44.75          74.00       -29.25        Vertical



  1830.00         62.39        25.10         4.12        41.21           50.40     74.00       -23.60      Horizontal
  2745.00         60.81        26.35         5.07        41.74           50.49     74.00       -23.51      Horizontal
  3660.00         49.11        27.72         5.92        41.58           41.17     74.00       -32.83      Horizontal
  4575.00         45.83        29.47         6.84        42.08           40.06     74.00       -33.94      Horizontal
  5490.00         48.71        30.54         7.18        41.85           44.58     74.00       -29.42      Horizontal




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                  Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                  Page 33 of 38


                                                                                    Report No: CCISE180111101

                                             Test channel: Highest channel
                                                  Detector: Peak Value
                  Read       Antenna        Cable     Preamp
 Frequency                                                         Level          Limit Line      Over
                  Level       Factor        Loss       Factor                                                Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)      Limit (dB)
                 (dBuV)       (dB/m)         (dB)       (dB)
  1854.00         53.64        24.95        4.17       41.31       41.45            74.00         -32.55       Vertical
  2781.00         54.40        26.50        5.10       41.70       44.30            74.00         -29.70       Vertical
  3708.00         46.85        27.84        5.98       41.66       39.01            74.00         -34.99       Vertical
  4635.00         45.91        29.90        6.89       42.12       40.58            74.00         -33.42       Vertical
  5562.00         43.79        30.50        7.24       41.81       39.72            74.00         -34.28       Vertical



  1854.00         57.42        24.95         4.17        41.31           45.23      74.00         -28.77     Horizontal
  2781.00         59.78        26.50         5.10        41.70           49.68      74.00         -24.32     Horizontal
  3708.00         56.42        27.84         5.98        41.66           48.58      74.00         -25.42     Horizontal
  4635.00         45.72        29.90         6.89        42.12           40.39      74.00         -33.61     Horizontal
  5562.00         44.71        30.50         7.24        41.81           40.64      74.00         -33.36     Horizontal
 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
 2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE1801111
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                    Page 34 of 38



Document Created: 2018-06-06 23:52:40
Document Modified: 2018-06-06 23:52:40

© 2024 FCC.report