The device has a standalone transmission.
According to KDB 447498 D01 General RF Exposure Guidance v0.5 The 1-g and 10-g SAR test
exclusion thresholds for 100MHz to 6GHz at test separation distances≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)]·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
f(GHz) is the RF channel transmit frequency in GHz
power and distance are rounded to the nearest mW and mm before calcuation
The result is rounded to one decimal place for comparison
Worse case is as below:[2440MHz -6.82dBm(0.21mW) output power]
(0.21mW/5mm) ·[√2.440GHz)]= 0.066<3.0 for 1-g SAR


Then SAR evaluation is not required.