14_ER100202 TestRpt DCD

FCC ID: 2ALCVER100202

Test Report

Download: PDF
FCCID_4432712

                                               TEST REPORT
 Reference No. ...................         :   WTS19S05030990W002

 FCC ID ................................   :   2ALCVER100202

 Applicant ............................    :   Emerson Radio Corp.

 Address ..............................    :   35 Waterview Blvd, Parsippany, New Jersey 07054, United States

 Manufacturer ....................         :   RICH FIELD ELECTRONICS COMPANY LIMITED
                                               No.10, LingXia Road, Tian Tou Jiao Village, Qiaotou Town, Dongguan
 Address ..............................    :   City, Guangdong, China
                                               Smartset Clock Radio 1.4’’ Aqua LED with Bluetooth, Wireless and
 Product...............................    :   USB Charging
 Model(s) .............................    :   ER100202, ER100203, ER100204, S101019, S101020, S101021

 Brand(s) ............................     :   Emerson, Scott

 Standards...........................      :   FCC Part 15 subpart C

 Date of Receipt sample ....               :   2019-05-17

 Date of Test .......................      :   2019-05-17 to 2019-06-05

 Date of Issue ......................      :   2019-06-06

 Test Result .........................     :   Pass


 Remarks:
 The results shown in this test report refer only to the sample(s) tested, this test report cannot be
 reproduced, except in full, without prior written permission of the company. The report would be invalid
 without specific stamp of test institute and the signatures of compiler and approver.

                                                Prepared By:
                                   Waltek Services (Shenzhen) Co., Ltd.
      Address: 1/F., Fukangtai Building, West Baima Road, Songgang Street, Baoan District, Shenzhen,
                                             Guangdong, China
                                           Tel :+86-755-83551033
                                           Fax:+86-755-83552400

         Compiled by:                                                       Approved by:




         Jack Wen / Test Engineer                                           Philo Zhong / Manager




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn                                     Page 1 of 20


Reference No.: WTS19S05030990W002                       Page 2 of 20



1.    Laboratories Introduction
Waltek Services (Shenzhen) Co., Ltd is a professional third-party testing and certification laboratory
with multi-year product testing and certification experience, established strictly in accordance with
ISO/IEC 17025 requirements, and accredited by ILAC (International Laboratory Accreditation Cooperation)
member. A2LA (American Association for Laboratory Accreditation, the certification number is 4243.01) of
USA, CNAS (China National Accreditation Service for Conformity Assessment, the registration number is
L3110) of China.Meanwhile, Waltek has got recognition as registration and accreditation laboratory from
EMSD (Electrical and Mechanical Services Department), and American Energy star, FCC(The Federal
Communications Commission), CEC(California energy efficiency), ISED (Innovation, Science and
Economic Development Canada). It’s the strategic partner and data recognition laboratory of international
authoritative organizations, such as Intertek(ETL-SEMKO), TÜV Rheinland, TÜV SÜD, etc.




Waltek Services (Shenzhen) Co., Ltd is one of the largest and the most comprehensive third party testing
laboratory in China. Our test capability covered four large fields: safety test. ElectroMagnetic
Compatibility(EMC), and energy performance, wireless radio. As a professional, comprehensive, justice
international test organization, we still keep the scientific and rigorous work attitude to help each client
satisfy the international standards and assist their product enter into globe market smoothly.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS19S05030990W002                  Page 3 of 20



1.1 Test Facility
      A. Accreditations for Conformity Assessment (International)
      Country/Region         Scope Covered By             Scope                Note
      USA                                                 FCC ID \ SDOC        1
      Canada                                              IC ID \ VOC          2
      Japan                                               MIC-T \ MIC-R        -
      Europe                                              EMCD \ RED           -
      Taiwan                                              NCC                  -
                             ISO/IEC 17025
      Hong Kong                                           OFCA                 -
      Australia                                           RCM                  -
      India                                               WPC                  -
      Thailand                                            NTC                  -
      Singapore                                           IDA                  -
      Note:
      1.   FCC Designation No.: CN1201. Test Firm Registration No.: 523476.
      2.   ISED CAB identifier: CN0013. Test Firm Registration No.: 7760A.

      B.TCBs and Notify Bodies Recognized Testing Laboratory.


      Recognized Testing Laboratory of …                  Notify body number
      TUV Rheinland
      Intertek
                                                          Optional.
      TUV SUD
      SGS
      Phoenix Testlab GmbH                                0700
      Element Materials Technology Warwick Ltd.           0891
      Timco Engineering, Inc.                             1177
      Eurofins Product Service GmbH                       0681




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


  Reference No.: WTS19S05030990W002               Page 4 of 20



  2.    Revision History
                           Date of
                                                          Date of
   Test report No.         Receipt      Date of Test                 Purpose    Comment   Approved
                                                           Issue
                           sample

                                        2019-05-17 to
WTS19S05030990W002        2019-05-17                    2019-06-06   original      -       Valid
                                         2019-06-05




  Waltek Services (Shenzhen) Co.,Ltd.
  http://www.waltek.com.cn


Reference No.: WTS19S05030990W002       Page 5 of 20



3.    Test Summary
                   Test Items                Test Requirement   Result

              Conducted Emissions                  15.207       PASS

          Radiated Spurious Emissions              15.209       PASS
               Occupied Bandwidth                  15.215       PASS
              Antenna Requirement                  15.203       PASS




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS19S05030990W002                                                  Page 6 of 20



4.     Contents
                                                                                                                                                               Page
      COVER PAGE ...................................................................................................................................... 1

1.    LABORATORIES INTRODUCTION .............................................................................................................. 2
      1.1          TEST FACILITY ....................................................................................................................................... 3
2.    REVISION HISTORY ....................................................................................................................................... 4

3.    TEST SUMMARY ............................................................................................................................................. 5

4.    CONTENTS ....................................................................................................................................................... 6

5.    GENERAL INFORMATION ............................................................................................................................. 7
      5.1          GENERAL DESCRIPTION OF E.U.T ........................................................................................................ 7
      5.2          DETAILS OF EUT ................................................................................................................................... 7
6.    EQUIPMENT USED DURING TEST ............................................................................................................. 8
      6.1          EQUIPMENTS LIST ................................................................................................................................. 8
      6.2          DESCRIPTION OF SUPPORT UNITS ........................................................................................................ 8
      6.3          MEASUREMENT UNCERTAINTY.............................................................................................................. 9
      6.4          TEST EQUIPMENT CALIBRATION ........................................................................................................... 9
7.    CONDUCTED EMISSION ............................................................................................................................. 10
      7.1          E.U.T. OPERATION ............................................................................................................................. 10
      7.2          EUT SETUP ......................................................................................................................................... 10
      7.3          MEASUREMENT DESCRIPTION ............................................................................................................ 10
      7.4          CONDUCTED EMISSION TEST RESULT ................................................................................................ 11
8.    RADIATED SPURIOUS EMISSIONS .......................................................................................................... 13
      8.1          EUT OPERATION ................................................................................................................................. 13
      8.2          TEST SETUP ........................................................................................................................................ 14
      8.3          SPECTRUM ANALYZER SETUP ............................................................................................................ 15
      8.4          TEST PROCEDURE ............................................................................................................................... 15
      8.5          SUMMARY OF TEST RESULTS ............................................................................................................. 16
9.    BANDWIDTH MEASUREMENT................................................................................................................... 17
      9.1          TEST PROCEDURE ............................................................................................................................... 17
      9.2          TEST RESULT PLOT: ........................................................................................................................... 17
10.       ANTENNA REQUIREMENT ..................................................................................................................... 18

11.       PHOTOGRAPHS-TEST SETUP.............................................................................................................. 19
      11.1         RADIATION EMISSION TEST SETUP ..................................................................................................... 19
      11.2         PHOTOGRAPH – CONDUCTED EMISSION TEST SETUP ....................................................................... 20




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS19S05030990W002                Page 7 of 20



5.   General Information

5.1 General Description of E.U.T
      Product:                   Smartset Clock Radio 1.4’’ Aqua LED with Bluetooth, Wireless
                                 and USB Charging
      Model(s):                  ER100202, ER100203, ER100204, S101019, S101020, S101021

      Model descriptions:        Only the model names, Brands, colors of the product and the LED
                                 colors are different, the others are all the same, the model
                                 ER100202 is the tested sample.
      Type of Modulation:         ASK
      Frequency Range:           0.112~0.205MHz

      Antenna installation:       Coil Antenna


5.2 Details of EUT
                                Adapter: Input: 100-240V~ 50/60Hz 1.0A Max
     Ratings:
                                Output: DC 9.0V 3.0A




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn                         Page 7 of 20


       Reference No.: WTS19S05030990W002                    Page 8 of 20



       6.      Equipment Used during Test
       6.1 Equipments List
Conducted Emissions
                                                                                       Last
                                                                                                     Calibration
Item           Equipment          Manufacturer         Model No.     Serial No.     Calibration
                                                                                                      Due Date
                                                                                       Date
  1         EMI Test Receiver         R&S                ESCI          101155       2018-09-15        2019-09-14
  2               LISN           SCHWARZBECK           NSLK 8128      8128-259      2018-09-15        2019-09-14
                                                                    261115-001-
  3              Limiter          CYBERTEK              EM5010                      2018-09-15        2019-09-14
                                                                       0024
  4              Cable              Laplace             RF300               -       2018-07-18        2019-07-17

3m Semi-anechoic Chamber for Radiation(TDK)
                                                                                       Last
                                                                                                     Calibration
Item           Equipment          Manufacturer         Model No.     Serial No.     Calibration
                                                                                                      Due Date
                                                                                       Date
  1           Test Receiver           R&S                ESCI          101296       2019-04-20        2020-04-19
            Trilog Broadband
  2                              SCHWARZBECK           VULB9160      9160-3325      2019-04-20        2020-04-19
                Antenna
  3     Active Loop Antenna Com-Power Corp.             AL-130R       10160007      2019-04-17        2020-04-16
  4             Amplifier          ANRITSU              MH648A         M43381       2019-04-20        2020-04-19
  5              Cable          HUBER+SUHNER             CBL2          525178       2019-04-20        2020-04-19
RF Conducted Testing
                                                                                       Last
                                                                                                     Calibration
Item           Equipment          Manufacturer         Model No.     Serial No.     Calibration
                                                                                                      Due Date
                                                                                       Date
  1         Spectrum Analyzer        Agilent            N9020A      MY49100060      2018-09-21        2019-09-20
            Spectrum Analyzer
  2                                   R&S                FSL6          100959       2018-09-10        2019-09-09
               (9k-6GHz)
  3         Humidity Chamber          GF           GTH-225-40-1P IAA061213          2018-08-12        2019-08-11
            Trilog Broadband
  4                              SCHWARZBECK           VULB9163            336      2019-04-05        2020-04-04
                Antenna
              Coaxial Cable
  5                                   Top             TYPE16(13M)           -       2018-09-10        2019-09-09
              (below 1GHz)

       6.2 Description of Support Units
                     Equipment               Manufacturer              Model No.                  Series No.

                            -                     -                             -                     -




       Waltek Services (Shenzhen) Co.,Ltd.
       http://www.waltek.com.cn


Reference No.: WTS19S05030990W002                 Page 9 of 20



6.3 Measurement Uncertainty

            Test Item                 Frequency Range            Uncertainty          Note

       Conducted Emissions             150kHz~30MHz               3.64dB              (1)
        Radiated Spurious
                                       26KHz~30MHz                3.03dB              (1)
           Emissions
        Radiated Spurious
                                      30MHz~1000MHz               5.03dB              (1)
           Emissions
     (1)This uncertainty represents an expanded uncertainty expressed at approximately the 95%
       confidence level using a coverage factor of k=2.

6.4 Test Equipment Calibration

     All the test equipments used are valid and calibrated by GUANG ZHOU GRG METROLOGY & TES
     T CO., LTD. address is No.163, Pingyun Rd. West of Huangpu Ave,Tianhe District, Guangzhou,
     Guangdong, China.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn                         Page 9 of 20


Reference No.: WTS19S05030990W002                   Page 10 of 20



7.    Conducted Emission

      Test Requirement:               FCC CFR 47 Part 15 Section 15.207
      Test Method:                    ANSI C63.10:2013
      Test Result:                    PASS
      Frequency Range:                150kHz to 30MHz
      Class/Severity:                 Class B
      Limit:                          66-56 dBV between 0.15MHz & 0.5MHz
                                      56 dBV between 0.5MHz & 5MHz
                                      60 dBV between 5MHz & 30MHz
      Detector:                       Peak for pre-scan (9kHz Resolution Bandwidth)

7.1 E.U.T. Operation
     Operating Environment :
     Temperature:                     25.5 C
     Humidity:                        51 % RH
     Atmospheric Pressure:            101.2kPa
     EUT Operation :                  Transmitting mode

     The test was performed in transmitting mode, the test data were shown in the report.

7.2 EUT Setup
      The EUT was placed on the test table in shielding room.



                  0.4m

                             EUT                                    Receiver    PC System

                  0.8m

                                                                                            0.8m

               LISN


                                                                          :50 Terminator


7.3 Measurement Description
     The maximised peak emissions from the EUT was scanned and measured for both the Live and
     Neutral Lines. Quasi-peak & average measurements were performed if peak emissions were within
     6dB of the average limit line.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS19S05030990W002     Page 11 of 20



7.4 Conducted Emission Test Result

      Live line:




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS19S05030990W002     Page 12 of 20




    Neutral line:




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS19S05030990W002                    Page 13 of 20



8.    Radiated Spurious Emissions
      Test Requirement:                 FCC CFR47 Part 15 Section 15.209
      Test Method:                      ANSI C63.10:2013
      Test Result:                      PASS
      Measurement Distance:             3m
      Limit:
      FCC Part15 Paragraph 15.209
                              Field Strength           Field Strength Limit at 3m Measurement Dist
         Frequency
                                          Distance
           (MHz)             uV/m                            uV/m                    dBuV/m
                                               (m)
       0.009 ~ 0.490      2400/F(kHz)        300      10000 * 2400/F(kHz)      20log(2400/F(kHz)) + 80
       0.490 ~ 1.705   24000/F(kHz)            30     100 * 24000/F(kHz)      20log(24000/F(kHz)) + 40
         1.705 ~ 30           30               30           100 * 30              20log(30) + 40
           30 ~ 88           100                3             100                    20log(100)
          88 ~ 216           150                3             150                    20log(150)
         216 ~ 960           200                3             200                    20log(200)
         Above 960           500                3             500                    20log(500)

8.1 EUT Operation

     Operating Environment :
     Temperature:                     23.5 C
     Humidity:                        51.1 % RH
     Atmospheric Pressure:            101.2kPa
     EUT Operation :
     Only the worst case transmitting mode were record in the report.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS19S05030990W002                 Page 14 of 20



8.2 Test Setup
      The radiated emission tests were performed in the 3m Semi- Anechoic Chamber test site, using the
      setup accordance with the ANSI C63.10: 2013.

      The test setup for emission measurement below 30MHz.




              Semi-anechoic 3m Chamber
              Turn Table From 0°to 360°




                                                        3m
                              EUT


                            Turn Table
           0.8m




                                  PC              Spectrum            AMP          Combining
                                System            Analyzer                          Network



      The test setup for emission measurement from 30 MHz to 1 GHz.



              Semi-anechoic 3m Chamber
              Antenna Elevation Varies From 1 to 4 m
              Turn Table From 0°to 360°
                                                        3m


                              EUT


           0.8m             Turn Table




                                 PC              Spectrum             AMP         Combining
                               System            Analyzer                          Network




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS19S05030990W002                            Page 15 of 20


8.3 Spectrum Analyzer Setup

          Below 30MHz
                           Sweep Speed .............................................. Auto
                           IF Bandwidth ................................................ 10kHz
                           Video Bandwidth.......................................... 10kHz
                           Resolution Bandwidth.................................. 10kHz
          30MHz ~ 1GHz
                           Sweep Speed .............................................. Auto
                           Detector ..................................................... PK
                           Resolution Bandwidth .................................. 100kHz
                           Video Bandwidth.......................................... 300kHz
8.4 Test Procedure
      1. The EUT is placed on a turntable, which is 0.8m above ground plane.
      2. The turntable shall be rotated for 360 degrees to determine the position of maximum emission
        level.
      3. EUT is set 3m away from the receiving antenna, which is moved from 1m to 4m to find out the
        maximum emissions. The spectrum was investigated from the lowest radio frequency signal
        generated in the device, without going below 9 kHz, up to the tenth harmonic of the highest
        fundamental frequency or to 40 GHz, whichever is lower.
      4. Maximum procedure was performed on the six highest emissions to ensure EUT compliance.
      5. And also, each emission was to be maximized by changing the polarization of receiving antenna
        both horizontal and vertical.
      6. Repeat above procedures until the measurements for all frequencies are complete.
      7. The radiation measurements are tested under 3-axes(X, Y, Z) position(X denotes lying on the
        table, Y denotes side stand and Z denotes vertical stand). After pre-test, It was found that the
        worse radiation emission was get at the X position. So the data shown was the X position only.




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


    Reference No.: WTS19S05030990W002                      Page 16 of 20



    8.5 Summary of Test Results
            Test Frequency: 9KHz ~ 30MHz, Note: Correct factor = Cable loss + Antenna factor

                                                                     Measurement
                           Measurement                    Correct
                                              Detector                  results         Limits         Margin
            Frequency        results                       factor
                                                                      (calculated)
              (MHz)
                              dBμV                                       dBμV/m         dBμV/m
                                              PK/QP        dB/m                                         dB
                              @3m                                         @3m            @3m

              0.161           41.19             QP        18.55             59.74       103.46         -43.72

              4.607           10.76             QP        23.69             34.45       69.50          -35.05

            Test Frequency: 30MHz ~ 1GHz


               Measurement                                                              Measuremen
                                 Detector                                     Correct                     Limit
Frequency        results                                  Height    Polar                 t results               Margin
                 (dBμV            (PK/QP         Degree                        factor                    (dBμV/
 (MHz)                                                      (m)     (H/V)               (calculated)               (dB)
                   @3m)               /Ave)                                     (dB)                         m)
                                                                                         (dBμV/m)

  35.08            33.56              QP          191       1.5      H         -14.11      19.46             40   -20.54
  35.08            33.18              QP          173       1.3      V         -14.11      19.08             40   -20.92
 220.51            34.71              QP          181       1.4      H         -13.20      21.51          46.5    -24.99
 220.51            36.53              QP             45     1.2      V         -13.20      23.32          46.5    -23.18
 520.28            36.63              QP          240       1.6      H         -5.43       31.19          46.5    -15.31
 520.28            38.10              QP          355       1.8      V         -5.43       32.67          46.5    -13.83




    Waltek Services (Shenzhen) Co.,Ltd.
    http://www.waltek.com.cn


Reference No.: WTS19S05030990W002                   Page 17 of 20



9.    Bandwidth Measurement
      Test Requirement:                               FCC CFR47 Part 15 Section 15.215
9.1 Test Procedure

      1. The transmitter shall be operated at its maximum carrier power measured under normal test
        conditions;
      2. The span of the analyzer shall be set to capture all products of the modulation process,including
        the emission skirts.
      3. The resolution bandwidth (RBW) shall be in the range of 1% to 5% of the occupied bandwidth
        (OBW) and video bandwidth (VBW) shall be approximately 3x RBW.
9.2 Test Result Plot:


                                                                         20dB Bandwidth
                  Test Channel(kHz)         99% Bandwidth(kHz)
                                                                          Emission(KHz)
                          161                      2.220                       2.620



      Test result plot as follows:




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS19S05030990W002                    Page 18 of 20



10. Antenna Requirement
      According to the FCC Part 15 Paragraph 15.203, an intentional radiator shall be designed to ensure
      that no antenna other than that furnished by the responsible party shall be used with the device. The
      use of a permanently attached antenna to the intentional radiator shall be considered sufficient to
      comply with the provisions of this section. This product has a Coil antenna, fulfill the requirement of
      this section.




  ANT




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS19S05030990W002             Page 19 of 20



11. Photographs-Test Setup
11.1   Radiation Emission Test Setup

                                         Below 30MHz




                                      From 30MHz to 1GHz




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn


Reference No.: WTS19S05030990W002                 Page 20 of 20


11.2   Photograph – Conducted Emission Test Setup




                                      ====== End of Report ======




Waltek Services (Shenzhen) Co.,Ltd.
http://www.waltek.com.cn



Document Created: 2019-09-13 14:14:13