18_ER100102 RFExp

FCC ID: 2ALCVER100102

RF Exposure Info

Download: PDF
FCCID_3727073

  FCC ID: 2ALCVER100102




  SAR Evaluation
         Test Requirement:           FCC Part 1.1307
         Evaluation Method:          FCC Part2.1093 & KDB 447498 D01 General RF Exposure Guidance v06
  Requirements
         1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
         ≤50 mm are determined by:
         [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] · [√
         f(GHz)] ≤3.0 for 1-g SAR and ≤7.5 for 10-g extremity SAR where


         1.    f(GHz) is the RF channel transmit frequency in GHz
         2.    Power and distance are rounded to the nearest mW and mm before calculation
         3.    The result is rounded to one decimal place for comparison
         The test exclusions are applicable only when the minimum test separation distance is ≤50 mm and
         for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
         distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion.


  Test result


Conduc                  Source-based          Minimum test
                                                                                     SAR Test
  ted    Conducted      time-averaged      separation distance SAR Test Exclusion
                                                                                     Exclusion
 Peak         Peak        maximum            required for the       Thresholds                      Result
                                                                                    Thresholds
power( power(mW) conducted output exposure conditions           Calculation Value
                                                                                       Limit
 dBm)                    power(mW)                (mm)
 -1.82        0.66            0.66                  5                  0.20             3.0      Compliance
Note: No SAR measurement is required.
  Remark: Max. duty factor is 100%
  Result: Compliance
  No SAR measurement is required.
                                                ======End======




  Waltek Services (Shenzhen) Co.,Ltd.
  http://www.waltek.com.cn



Document Created: 2018-01-17 15:15:30
Document Modified: 2018-01-17 15:15:30

© 2024 FCC.report