RF Exposure

FCC ID: 2ALCFXO-9769

RF Exposure Info

Download: PDF
FCCID_4343218

Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG190327001-00

FCC §15.247 (i) & §1.1310 & §2.1091- MAXIMUM PERMISSIBLE
EXPOSURE (MPE)
Applicable Standard
According to subpart 15.247(i)and subpart §1.1310, systems operating under the provisions of this section
shall be operated in a manner that ensures that the public is not exposed to radio frequency energy level in
excess of the Commission’s guidelines.

Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091)

                          (B) Limits for General Population/Uncontrolled Exposure
Frequency Range         Electric Field       Magnetic Field        Power Density              Averaging Time
      (MHz)            Strength (V/m)        Strength (A/m)           (mW/cm2)                  (minutes)
     0.3–1.34                614                   1.63                 *(100)                      30
     1.34–30                824/f                 2.19/f               *(180/f²)                    30
     30–300                  27.5                 0.073                   0.2                       30
    300–1500                  /                      /                  f/1500                      30
  1500–100,000                /                      /                    1.0                       30

f = frequency in MHz; * = Plane-wave equivalent power density;

According to §1.1310 and §2.1091 RF exposure is calculated.


Calculation formula:

Prediction of power density at the distance of the applicable MPE limit
S = PG/4R² = power density (in appropriate units, e.g. mW/cm2);
P = power input to the antenna (in appropriate units, e.g., mW);
G = power gain of the antenna in the direction of interest relative to an isotropic radiator, the power gain
factor, is normally numeric gain;
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm);


Calculated Data:

                                                     Conducted
                                                    output power     Evaluation       Power       MPE
                Frequency       Antenna Gain
      Mode                                        including Tune-     Distance       Density      Limit
                  (MHz)
                                                    up Tolerance        (cm)        (mW/cm2)    (mW/cm2)
                              (dBi)   (numeric)   (dBm) (mW)
      WLAN       2412-2462     -2.0      0.63       24      251.19      20.00         0.032        1.0

Note: the Max. Target Power including Tolerance was declared by manufacturer.

Result: Compliance, The device meets MPE requirement for Devices Used by the General Public
(Uncontrolled Environment) at distance ≥20 cm.




                                                                                                  Page 11 of 51



Document Created: 2019-07-03 18:30:18
Document Modified: 2019-07-03 18:30:18

© 2024 FCC.report