Test Report

FCC ID: 2ALCFXO-9602

Test Report

Download: PDF
FCCID_3974589

                                      TEST REPORT


                                            FCC ID: 2ALCFXO-9602
                                   Product: Circular Wireless Charger
                                              Model No.: XO-9602
                                         Additional Model: MA-2803
                                                 Trade Mark: N/A
                                        Report No.: TCT180709E001
                                          Issued Date: Jul. 12, 2018



                                                      Issued for:

                       Dongguan Xing Yue Electronic co., Ltd
       #98 LiWu Swan Industrial District, Qiao Tou Town, Dong Guan City, Guang
                                     Dong, China



                                                      Issued By:

                              Shenzhen Tongce Testing Lab.
       1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District,
                              Shenzhen, Guangdong, China
                                   TEL: +86-755-27673339
                                            FAX: +86-755-27673332




Note: This report shall not be reproduced except in full, without the written approval of Shenzhen Tongce Testing Lab.
       This document may be altered or revised by Shenzhen Tongce Testing Lab. personnel only, and shall be noted in
       the revision section of the document. The test results in the report only apply to the tested sample.




   Hotline: 400-6611-140        Tel: 86-755-27673339          Fax: 86-755-27673332          http://www.tct-lab.com


                                                                                                         Report No.: TCT180709E001

                                              TABLE OF CONTENTS

1. Test Certification ...................................................................................... 3
2. Test Result Summary ............................................................................... 4
3. EUT Description ........................................................................................ 5
4. Genera Information ................................................................................... 6
     4.1. Test environment and mode ................................................................................ 6
     4.2. Description of Support Units ............................................................................... 6
5. Facilities and Accreditations ................................................................... 7
     5.1. Facilities ................................................................................................................ 7
     5.2. Location ................................................................................................................. 7
     5.3. Measurement Uncertainty .................................................................................... 7
6. Test Results and Measurement Data....................................................... 8
     6.1. Antenna requirement ............................................................................................ 8
     6.2. Conducted Emission ............................................................................................ 9
     6.3. Radiated Spurious Emission Measurement ..................................................... 13
 Appendix A: Photographs of Test Setup
 Appendix B: Photographs of EUT




                                                                                                                     Page 2 of 28

   Hotline: 400-6611-140           Tel: 86-755-27673339            Fax: 86-755-27673332             http://www.tct-lab.com


                                                                            Report No.: TCT180709E001

1. Test Certification
 Product:          Circular Wireless Charger
 Model No.:        XO-9602
 Additional
                   MA-2803
 Model No.:
 Trade Mark:       N/A
 Applicant:        Dongguan Xing Yue Electronic co., Ltd

                   #98 LiWu Swan Industrial District, Qiao Tou Town, Dong Guan City,
 Address:
                   Guang Dong, China

 Manufacturer: Dongguan Xing Yue Electronic co., Ltd

                   #98 LiWu Swan Industrial District, Qiao Tou Town, Dong Guan City,
 Address:
                   Guang Dong, China

 Date of Test:     Jul. 09, 2018 - Jul. 11, 2018
 Applicable
                   FCC CFR Title 47 Part 15 Subpart C
 Standards:


The above equipment has been tested by Shenzhen Tongce Testing Lab. and found
compliance with the requirements set forth in the technical standards mentioned above. The
results of testing in this report apply only to the product/system, which was tested. Other
similar equipment will not necessarily produce the same results due to production tolerance
and measurement uncertainties.




                                                             Date:       Jul. 11, 2018
              Tested By:

                                  Brews Xu

          Reviewed By:                                       Date:       Jul. 12, 2018

                                 Beryl Zhao

          Approved By:                                       Date:       Jul. 12, 2018

                                   Tomsin




                                                                                     Page 3 of 28

 Hotline: 400-6611-140     Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                                             Report No.: TCT180709E001

2.       Test Result Summary

             Requirement                                   CFR 47 Section                       Result

        Antenna requirement                                     §15.203                         PASS

     AC Power Line Conducted
                                                                §15.207                         PASS
           Emission

         Spurious        Emission                             §15.209(a)(f)                     PASS
 Note:
       1. PASS: Test item meets the requirement.

       2. Fail: Test item does not meet the requirement.

       3. N/A: Test case does not apply to the test object.

       4. The test result judgment is decided by the limit of test standard.




                                                                                                      Page 4 of 28

     Hotline: 400-6611-140         Tel: 86-755-27673339            Fax: 86-755-27673332   http://www.tct-lab.com


                                                                           Report No.: TCT180709E001

3. EUT Description
Product:                        Circular Wireless Charger
Model No.:                      XO-9602
Additional Model No.:           MA-2803
Trade Mark:                     N/A

Hardware Version:               YH0719-1

Software Version:               XO-9602 DataSheet V1.0
Operation Frequency:            110-205KHz
Modulation Technology:          Load modulation
Antenna Type:                   Inductive loop coil Antenna

Power Supply:                   DC 5V via adapter
                                All models above are identical in interior structure, electrical
Remark:                         circuits and components, and just model names are different
                                for the marketing requirement.




                                                                                    Page 5 of 28

  Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                                            Report No.: TCT180709E001

4. Genera Information
4.1. Test environment and mode
  Operating Environment:
     Temperature:                                           25.0 °C
     Humidity:                                              56 % RH
     Atmospheric Pressure:                                  1010 mbar

  Test Mode:
     Engineering mode:                                      Keep the EUT in continuous transmitting
                                                            by select channel and modulations(The
                                                            value of duty cycle is 98.46%) with
                                                            Fully-charged battery.
  The sample was placed (0.1m below 1GHz, 1.5m above 1GHz) above the ground
  plane of 3m chamber. Measurements in both horizontal and vertical polarities were
  performed. During the test, each emission was maximized by: having the EUT
  continuously working, investigated all operating modes, rotated about all 3 axis (X, Y &
  Z) and considered typical configuration to obtain worst position, manipulating
  interconnecting cables, rotating the turntable, varying antenna height from 1m to 4m in
  both horizontal and vertical polarizations. The emissions worst-case are shown in Test
  Results of the following pages.
4.2. Description of Support Units
 The EUT has been tested as an independent unit together with other necessary
 accessories or support units. The following support units or accessories were used to
 form a representative test configuration during the tests.


   Equipment              Model No.               Serial No.               FCC ID              Trade Name

  Mobile Phone              Iphone6          FFQQ8F8AG5MQ BCG-E2816A                               Apple

     Adapter              KZ0502000                     /                       /                      /
 Note:
     1. All the equipment/cables were placed in the worst-case configuration to maximize the emission during the test.
     2. Grounding was established in accordance with the manufacturer’s requirements and conditions for the intended
         use.

     3. For conducted measurements (Output Power, 6dB Emission Bandwidth, Power Spectral Density, Spurious
         Emissions), the antenna of EUT is connected to the test equipment via temporary antenna connector, the
      antenna connector is soldered on the antenna port of EUT, and the temporary antenna connector is listed in the
      Test Instruments.




                                                                                                       Page 6 of 28

  Hotline: 400-6611-140        Tel: 86-755-27673339         Fax: 86-755-27673332        http://www.tct-lab.com


                                                                              Report No.: TCT180709E001

5.       Facilities and Accreditations
5.1. Facilities
 The test facility is recognized, certified, or accredited by the following organizations:
 ● FCC - Registration No.: 645098
   Shenzhen Tongce Testing Lab
   The 3m Semi-anechoic chamber has been registered and fully described in a report
   with the (FCC) Federal Communications Commission. The acceptance letter from the
   FCC is maintained in our files.
 ● IC - Registration No.: 10668A-1
   The 3m Semi-anechoic chamber of Shenzhen TCT Testing Technology Co., Ltd. has
   been registered by Certification and Engineering Bureau of Industry Canada for radio
   equipment testing
5.2. Location
     Shenzhen Tongce Testing Lab
     Address: 1B/F., Building 1, Yibaolai Industrial Park, Qiaotou, Fuyong, Baoan District,
              Shenzhen, Guangdong, China
     TEL: +86-755-27673339
5.3. Measurement Uncertainty
 The reported uncertainty of measurement y ± U, where expended uncertainty U is based
 on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of
 confidence of approximately 95 %.
     No.     Item                                                               MU
     1       Conducted Emission                                                 ±2.56dB
     2       RF power, conducted                                                ±0.12dB
     3       Spurious emissions, conducted                                      ±0.11dB
     4       All emissions, radiated(<1G)                                       ±3.92dB
     5       All emissions, radiated(>1G)                                       ±4.28dB
     6       Temperature                                                        ±0.1°C
     7       Humidity                                                           ±1.0%




                                                                                       Page 7 of 28

     Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                              Report No.: TCT180709E001

6.      Test Results and Measurement Data
6.1. Antenna requirement

     Standard requirement:           FCC Part15 C Section 15.203
     15.203 requirement:
     An intentional radiator shall be designed to ensure that no antenna other than that
     furnished by the responsible party shall be used with the device. The use of a
     permanently attached antenna or of an antenna that uses a unique coupling to the
     intentional radiator, the manufacturer may design the unit so that a broken antenna
     can be replaced by the user, but the use of a standard antenna jack or electrical
     connector is prohibited.
     E.U.T Antenna:
     The antenna is inductive loop coil antenna which permanently attached.




       Antenna




                                                                                       Page 8 of 28

     Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                           Report No.: TCT180709E001


6.2. Conducted Emission
6.2.1. Test Specification

  Test Requirement:               FCC Part15 C Section 15.207
  Test Method:                    ANSI C63.10:2013
  Frequency Range:                150 kHz to 30 MHz
  Receiver setup:                 RBW=9 kHz, VBW=30 kHz, Sweep time=auto

                                     Frequency range                Limit (dBuV)
                                          (MHz)             Quasi-peak        Average
  Limits:                                0.15-0.5            66 to 56*        56 to 46*
                                           0.5-5                56               46
                                           5-30                 60               50




  Test Setup:




  Test Mode:                      Charging + Transmitting Mode
                                  1. The E.U.T is connected to an adapter through a line
                                     impedance stabilization network (L.I.S.N.). This
                                     provides a 50ohm/50uH coupling impedance for the
                                     measuring equipment.
                                  2. The peripheral devices are also connected to the main
                                     power through a LISN that provides a 50ohm/50uH
                                     coupling impedance with 50ohm termination. (Please
  Test Procedure:
                                     refer to the block diagram of the test setup and
                                     photographs).
                                  3. Both sides of A.C. line are checked for maximum
                                     conducted interference. In order to find the maximum
                                     emission, the relative positions of equipment and all of
                                     the interface cables must be changed according to
                                     ANSI C63.10: 2013 on conducted measurement.
  Test Result:                    PASS




                                                                                    Page 9 of 28

  Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                                              Report No.: TCT180709E001

6.2.2. Test Instruments

                      Conducted Emission Shielding Room Test Site (843)
       Equipment                Manufacturer            Model          Serial Number Calibration Due
      Test Receiver                    R&S               ESPI               101401              Sep. 27, 2018
            LISN                 Schwarzbeck         NSLK 8126             8126453              Sep. 27, 2018
       Coax cable
                                       TCT              CE-05                  N/A              Sep. 27, 2018
     (9KHz-30MHz)
                                    Shurple
   EMI Test Software                                   EZ-EMC                  N/A                     N/A
                                  Technology
 Note: The calibration interval of the above test instruments is 12 months and the calibrations are traceable to
         international system unit (SI).




                                                                                                        Page 10 of 28

  Hotline: 400-6611-140         Tel: 86-755-27673339        Fax: 86-755-27673332          http://www.tct-lab.com


                                                                                         Report No.: TCT180709E001

  6.2.3. Test data

                           Please refer to following diagram for individual

Conducted Emission on Line Terminal of the power line (150 kHz to 30MHz)




  Note:
      Freq. = Emission frequency in MHz
      Reading level (dBµV) = Receiver reading
      Corr. Factor (dB) = Antenna factor + Cable loss
      Measurement (dBµV) = Reading level (dBµV) + Corr. Factor (dB)
      Limit (dBµV) = Limit stated in standard
      Margin (dB) = Measurement (dBµV) – Limits (dBµV)
      Q.P. =Quasi-Peak
      AVG =average
      * is meaning the worst frequency has been tested in the frequency range 150 kHz to 30MHz

                                                                                                 Page 11 of 28

  Hotline: 400-6611-140      Tel: 86-755-27673339       Fax: 86-755-27673332         http://www.tct-lab.com


                                                                                         Report No.: TCT180709E001


Conducted Emission on Neutral Terminal of the power line (150 kHz to 30MHz)




  Note1:
      Freq. = Emission frequency in MHz
      Reading level (dBµV) = Receiver reading
      Corr. Factor (dB) = Antenna factor + Cable loss
      Measurement (dBµV) = Reading level (dBµV) + Corr. Factor (dB)
      Limit (dBµV) = Limit stated in standard
      Margin (dB) = Measurement (dBµV) – Limits (dBµV)
      Q.P. =Quasi-Peak      AVG =average
      * is meaning the worst frequency has been tested in the frequency range 150 kHz to 30MHz.




                                                                                                  Page 12 of 28

  Hotline: 400-6611-140      Tel: 86-755-27673339        Fax: 86-755-27673332        http://www.tct-lab.com


                                                                                      Report No.: TCT180709E001


6.3. Radiated Spurious Emission Measurement
6.3.1. Test Specification

  Test Requirement:               FCC Part15 C Section 15.209
  Test Method:                    ANSI C63.10: 2013
  Frequency Range:                9 kHz to 25 GHz
  Measurement Distance:           3m
  Antenna Polarization:           Horizontal & Vertical
  Operation mode:                 Refer to item 4.1
                                    Frequency       Detector        RBW        VBW           Remark
                                   9kHz- 150kHz    Quasi-peak      200Hz       1kHz      Quasi-peak Value
                                     150kHz-       Quasi-peak       9kHz      30kHz      Quasi-peak Value
  Receiver Setup:                     30MHz
                                   30MHz-1GHz      Quasi-peak     100KHz     300KHz      Quasi-peak Value
                                                     Peak          1MHz       3MHz         Peak Value
                                    Above 1GHz
                                                     Peak          1MHz       10Hz        Average Value

                                                                   Field Strength          Measurement
                                         Frequency
                                                                 (microvolts/meter)      Distance (meters)
                                         0.009-0.490                2400/F(KHz)                 300
                                         0.490-1.705               24000/F(KHz)                  30
                                          1.705-30                       30                      30
                                             30-88                      100                       3
                                            88-216                      150                       3
  Limit:                                   216-960                      200                       3
                                         Above 960                      500                       3

                                                                             Measurement
                                                         Field Strength
                                       Frequency                               Distance         Detector
                                                       (microvolts/meter)
                                                                               (meters)
                                                                 500               3            Average
                                      Above 1GHz
                                                                5000               3             Peak

                                  For radiated emissions below 30MHz




  Test setup:




                                  30MHz to 1GHz



                                                                                              Page 13 of 28

  Hotline: 400-6611-140   Tel: 86-755-27673339     Fax: 86-755-27673332         http://www.tct-lab.com


                                                                         Report No.: TCT180709E001




                                Above 1GHz




                                1. For the radiated emission test below 1GHz:
                                    The EUT was placed on a turntable with 0.8 meter
                                    above ground. The EUT was set 3 meters from the
                                    interference receiving antenna, which was mounted
                                    on the top of a variable height antenna tower. The
                                    EUT was arranged to its worst case and then tune
                                    the antenna tower (from 1 m to 4 m) and turntable
                                    (from 0 degree to 360 degrees) to find the maximum
                                    reading. A pre-amp and a high PASS filter are used
                                    for the test in order to get better signal level.
                                    For the radiated emission test above 1GHz:
Test Procedure:                     Place the measurement antenna on a turntable with
                                    1.5 meter above ground, which is away from each
                                    area of the EUT determined to be a source of
                                    emissions at the specified measurement distance,
                                    while keeping the measurement antenna aimed at
                                    the source of emissions at each frequency of
                                    significant emissions, with polarization oriented for
                                    maximum response. The measurement antenna
                                    may have to be higher or lower than the EUT,
                                    depending on the radiation pattern of the emission
                                    and staying aimed at the emission source for
                                    receiving the maximum signal. The final

                                                                                 Page 14 of 28

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT180709E001
                                    measurement antenna elevation shall be that which
                                    maximizes the emissions. The measurement
                                    antenna elevation for maximum emissions shall be
                                    restricted to a range of heights of from 1 m to 4 m
                                    above the ground or reference ground plane.
                                2. Corrected Reading: Antenna Factor + Cable Loss +
                                    Read Level - Preamp Factor = Level
                                3. For measurement below 1GHz, If the emission level
                                    of the EUT measured by the peak detector is 3 dB
                                    lower than the applicable limit, the peak emission
                                    level will be reported. Otherwise, the emission
                                    measurement will be repeated using the quasi-peak
                                    detector and reported.
                                4. Use the following spectrum analyzer settings:
                                   (1) Span shall wide enough to fully capture the
                                        emission being measured;
                                   (2) Set RBW=100 kHz for f < 1 GHz; VBW ≥RBW;
                                        Sweep = auto; Detector function = peak; Trace =
                                        max hold;
                                   (3) Set RBW = 1 MHz, VBW= 3MHz for f  1 GHz
                                        for peak measurement.
                                    For average measurement: VBW = 10 Hz, when
                                    duty cycle is no less than 98 percent. VBW ≥ 1/T,
                                    when duty cycle is less than 98 percent where T is
                                    the minimum transmission duration over which the
                                    transmitter is on and is transmitting at its maximum
                                    power control level for the tested mode of operation.
Test mode:                      Refer to section 4.1 for details
Test results:                   PASS




                                                                                 Page 15 of 28

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                                              Report No.: TCT180709E001

6.3.2. Test Instruments

                                    Radiated Emission Test Site (966)
        Name of                                                                Serial
                                 Manufacturer              Model                               Calibration Due
       Equipment                                                              Number
                               ROHDE&SCHW
      Test Receiver                                        ESVD                100008            Sep. 27, 2018
                                   ARZ
                               ROHDE&SCHW
  Spectrum Analyzer                                         FSQ                200061            Sep. 27, 2018
                                   ARZ
                                EM Electronics
      Pre-amplifier              Corporation             EM30265             07032613            Sep. 27, 2018
                                  CO.,LTD
      Pre-amplifier                        HP              8447D           2727A05017            Sep. 27, 2018

      Loop antenna                   ZHINAN             ZN30900A                12024            Sep. 27, 2018

  Broadband Antenna              Schwarzbeck            VULB9163                 340             Sep. 27, 2018

      Horn Antenna               Schwarzbeck           BBHA 9120D                631             Sep. 27, 2018

      Horn Antenna               Schwarzbeck             BBH 9170                582             Sep. 27, 2018
     Antenna Mast                     Keleto             CC-A-4M                 N/A                    N/A
       Coax cable
                                           TCT          RE-low-01                N/A             Sep. 27, 2018
      (9KHz-1GHz)
       Coax cable
                                           TCT          RE-high-02               N/A             Sep. 27, 2018
     (9KHz-40GHz)
       Coax cable
                                           TCT          RE-low-03                N/A             Sep. 27, 2018
      (9KHz-1GHz)
       Coax cable
                                           TCT          RE-high-04               N/A             Sep. 27, 2018
     (9KHz-40GHz)

                                     Shurple
   EMI Test Software                                      EZ-EMC                 N/A                    N/A
                                   Technology

 Note: The calibration interval of the above test instruments is 12 months and the calibrations are traceable to
         international system unit (SI).




                                                                                                        Page 16 of 28

  Hotline: 400-6611-140         Tel: 86-755-27673339        Fax: 86-755-27673332          http://www.tct-lab.com


                                                                               Report No.: TCT180709E001

6.3.3. Test Data
                            Please refer to following diagram for individual
                                          9KHz-30MHz
9KHz-150KHz:




                                                                                       Page 17 of 28

  Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332      http://www.tct-lab.com


                                                                           Report No.: TCT180709E001


150KHz-30MHz:




                                                                                   Page 18 of 28

  Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                           Report No.: TCT180709E001


                                          30MHz-1GHz
Horizontal:




                                                                                   Page 19 of 28

  Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                                          Report No.: TCT180709E001


Vertical:




Note:
   Emission Level=Peak Reading + Correction Factor; Correction Factor= Antenna Factor + Cable loss – Pre-amplifier




                                                                                                   Page 20 of 28

   Hotline: 400-6611-140      Tel: 86-755-27673339        Fax: 86-755-27673332        http://www.tct-lab.com


                                                                         Report No.: TCT180709E001


                   Appendix A: Photographs of Test Setup
                           Product: Circular Wireless Charger
                                    Model: XO-9602
                                  Radiated Emission




                                                                                 Page 21 of 28

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT180709E001


                                   Conducted Emission




                                                                                 Page 22 of 28

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT180709E001


                        Appendix B: Photographs of EUT
                          Product: Circular Wireless Charger
                                   Model: XO-9602
                                   External Photos




                                                                                 Page 23 of 28

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT180709E001




                                                                                 Page 24 of 28

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT180709E001




                                                                                 Page 25 of 28

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT180709E001


                          Product: Circular Wireless Charger
                                   Model: XO-9602
                                   Internal Photos




                                                                                 Page 26 of 28

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT180709E001




                                                                                 Page 27 of 28

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com


                                                                         Report No.: TCT180709E001




                            *****END OF REPORT*****




                                                                                 Page 28 of 28

Hotline: 400-6611-140   Tel: 86-755-27673339   Fax: 86-755-27673332   http://www.tct-lab.com



Document Created: 2018-08-23 15:08:48
Document Modified: 2018-08-23 15:08:48

© 2024 FCC.report