RF Exposure

FCC ID: 2ALCFXO-9602

RF Exposure Info

Download: PDF
FCCID_3974587

                                          RF Exposure Considerations


1. Measuring Standard
 KDB 680106 D01 RF Exposure Wireless Charging Apps v03
2. Requirements
 According to the item 5.b of KDB 680106 D01v03:

 Inductive wireless power transfer applications with supporting field strength results and meeting all of the following
 requirements are not required to submit a KDB inquiry for devices approved using SDoC or a PAG for equipment
 approved using certification to address RF exposure compliance. However, the responsible party is required to keep
 a copy of the test report in accordance with KDB 865664 D02. A copy of the test report is to be submitted with the
 application if the device is approved using certification.

 (1) Power transfer frequency is less than 1 MHz.

 (2) Output power from each primary coil is less than or equal to 15 watts.

 (3) The transfer system includes only single primary and secondary coils. This includes charging systems that may
 have multiple primary coils and clients that are able to detect and allow coupling only between individual pairs of
 coils.

 (4) Client device is placed directly in contact with the transmitter.

 (5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion).

 (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from all
 simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.


                                   Limits For Maximum Permissible Exposure (MPE)


3. Test Setup




 Note: Measurements should be made from all sides and the top of the primary/client pair, with the 15cm measured
 from the center of the probe(s) to the edge of the device.


4.Test Procedure
 1) The RF exposure test was performed in anechoic chamber.
 2) The measurement probe was placed at 15 cm surrounding the device and 20 cm above the top surface of the
 charger and the geometric center of probe.
 3) The highest emission level was recorded and compared with limit as soon as measurement of each
 points (A, B, C, D, E) were completed.
 4) The EUT was measured according to the dictates of KDB 680106 D01 v03.
 Remark;
 The EUT’s test position A, B, C, D and E is valid for the E and H field measurements.

5. Test Equipment List
            Equipment                  Manufacturer                Model No.             Calibration Due

       Magnetic field meter               NARDA                     ELT-400              Sep. 27, 2018


6. Test Result


       E-Filed Strength 15 cm surrounding the device and 20 cm above the top surface of the EUT (V/m)
            Frequency                                                                Reference
Battery                     Test        Test       Test       Test         Test                      Limits
               Range                                                                   Limits
Power                     Position A Position B Position C Position D Position E                   Test (V/m)
                (KHz)                                                                Test (V/m)

  1%        110~ 205        1.57       1.65        1.63       1.72        1.48          307           614



 50%        110~ 205        1.61       1.63        1.59       1.69        1.51          307           614



 99%        110~ 205        1.63       1.60        1.63       1.68        1.47          307           614



Stand-by    110~ 205        1.66       1.59        1.65       1.74        1.55          307           614




       H-Filed Strength 15 cm surrounding the device and 20 cm above the top surface of the EUT (A/m)
            Frequency                                                               Reference
Battery                     Test        Test       Test       Test        Test                      Limits
               Range                                                                   Limits
Power                     Position A Position B Position C Position D Position E                  Test ((A/m)
                (KHz)                                                               Test (A/m)

  1%        110~ 205       0.201       0.187      0.196       0.198       0.187        0.815         1.63



 50%        110~ 205       0.189       0.182      0.185       0.188       0.180        0.815         1.63



 99%        110~ 205       0.181       0.178      0.180       0.179       0.176        0.815         1.63



Stand-by    110~ 205       0.184       0.189      0.187       0.186       0.209        0.815         1.63


7. Test Set-up Photo



Document Created: 2018-08-23 14:36:54
Document Modified: 2018-08-23 14:36:54