Test Report

FCC ID: 2ALCFXO-9549

Test Report

Download: PDF
FCCID_3825444

                                                                                      Page 1 of 29




                     FCC Test Report

                          Report No.: AGC02724180304FE03




 FCC ID                         : 2ALCFXO-9549

 APPLICATION PURPOSE            : Original Equipment

 PRODUCT DESIGNATION            : Wooden Wireless Charging Pad

 BRAND NAME                     : N/A

 MODEL NAME                     : XO-9549

 CLIENT                         : Dongguan Xing Yue Electronic Co., Ltd

 DATE OF ISSUE                  : Apr. 08, 2018
 STANDARD(S)
                                : FCC Part 15 Rules
 TEST PROCEDURE(S)
 REPORT VERSION                 : V1.0




       Attestation of Global Compliance (Shenzhen) Co., Ltd

CAUTION:
This report shall not be reproduced except in full without the written permission of the test
laboratory and shall not be quoted out of context.


                                                               Report No.: AGC02724180304FE03
                                                                                   Page 2 of 29


                                  REPORT REVISE RECORD


Report Version   Revise Time   Issued Date     Valid Version              Notes

    V1.0              /        Apr. 08, 2018       Valid              Initial Release


                                                                                                               Report No.: AGC02724180304FE03
                                                                                                                                   Page 3 of 29


                                                               TABLE OF CONTENTS

1. VERIFICATION OF CONFORMITY.................................................................................................................. 4

2. GENERAL INFORMATION .............................................................................................................................. 5

   2.1. PRODUCT DESCRIPTION ........................................................................................................................ 5

3. MEASUREMENT UNCERTAINTY ................................................................................................................... 6

4. DESCRIPTION OF TEST MODES ................................................................................................................... 7

5. SYSTEM TEST CONFIGURATION .................................................................................................................. 8

   5.1. CONFIGURATION OF EUT SYSTEM........................................................................................................ 8
   5.2. EQUIPMENT USED IN EUT SYSTEM ....................................................................................................... 8
   5.3. SUMMARY OF TEST RESULTS ................................................................................................................ 8

6. TEST FACILITY ................................................................................................................................................ 9

7. RADIATED EMISSION ................................................................................................................................... 10

   7.1TEST LIMIT ................................................................................................................................................ 10
   7.2. MEASUREMENT PROCEDURE ............................................................................................................. 11
   7.3. TEST SETUP............................................................................................................................................ 12
   7.4. TEST RESULT.......................................................................................................................................... 13

8. 20DB BANDWIDTH ........................................................................................................................................ 16

   8.1. MEASUREMENT PROCEDURE ............................................................................................................. 16
   8.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION) .................................................................... 16
   8.3. MEASUREMENT RESULTS .................................................................................................................... 17

9. FCC LINE CONDUCTED EMISSION TEST .................................................................................................. 18

   9.1. LIMITS OF LINE CONDUCTED EMISSION TEST .................................................................................. 18
   9.2. BLOCK DIAGRAM OF LINE CONDUCTED EMISSION TEST ................................................................ 18
   9.3. PRELIMINARY PROCEDURE OF LINE CONDUCTED EMISSION TEST ............................................. 19
   9.4. FINAL PROCEDURE OF LINE CONDUCTED EMISSION TEST ............................................................ 19
   9.5. TEST RESULT OF LINE CONDUCTED EMISSION TEST ...................................................................... 20

APPENDIX A: PHOTOGRAPHS OF TEST SETUP .......................................................................................... 22

APPENDIX B: PHOTOGRAPHS OF EUT ......................................................................................................... 24


                                                                           Report No.: AGC02724180304FE03
                                                                                               Page 4 of 29


  1. VERIFICATION OF CONFORMITY
Applicant                  Dongguan Xing Yue Electronic Co., Ltd
Address                    #98 LiWu Swan Industrial District, Qiao Tou Town, Dong Guan, Guang Dong, China
Manufacturer               Dongguan Xing Yue Electronic Co., Ltd
Address                    #98 LiWu Swan Industrial District, Qiao Tou Town, Dong Guan, Guang Dong, China
Product Designation        Wooden Wireless Charging Pad
Brand Name                 N/A
Test Model                 XO-9549
Date of test               Mar. 30, 2018 to Apr. 08, 2018
Deviation                  None
Condition of Test Sample Normal
Test Result                Pass
Report Template            AGCRT-US-BR/RF
  We hereby certify that:
  The above equipment was tested by Attestation of Global Compliance (Shenzhen) Co., Ltd. The test data, data
  evaluation, test procedures, and equipment configurations shown in this report were made in accordance with
  the procedures given in ANSI C63.10 (2013) and the energy emitted by the sample EUT tested as described
  in this report is in compliance with Section 15.207, 15.209, 15.203 of the FCC Part 15, Subpart C Rules.
  The results of testing in this report apply to the product/system which was tested only.


                           Tested by

                                               Max Zhang(Zhang Yi)         Apr. 08, 2018


                         Reviewed by


                                                Bart Xie(Xie Xiaobin)      Apr. 08, 2018


                                                                        Report No.: AGC02724180304FE03
                                                                                            Page 5 of 29


2. GENERAL INFORMATION
2.1. PRODUCT DESCRIPTION
A major technical description of EUT is described as following
Operation Frequency                          148.5KHz
Maximum field strength                       50.61dBuV/m(AV)@3m
Modulation                                   FSK
Number of channels                           1
Antenna Gain                                 0dBi
Antenna Designation                          Integrated Antenna (Met 15.203 Antenna requirement)
Hardware Version                             V1.0
Software Version                             V1.0
Power Supply                                 DC 5V


                                                                          Report No.: AGC02724180304FE03
                                                                                              Page 6 of 29


3. MEASUREMENT UNCERTAINTY
The uncertainty is calculated using the methods suggested in the “Guide to the Expression of Uncertainty in
measurement” (GUM) published by CISPR and ANSI.
- Uncertainty of Conducted Emission, Uc = ±3.2 dB
- Uncertainty of Radiated Emission below 1GHz, Uc = ±3.9 dB
- Uncertainty of Radiated Emission above 1GHz, Uc = ±4.8 dB


                                                                           Report No.: AGC02724180304FE03
                                                                                               Page 7 of 29


4. DESCRIPTION OF TEST MODES
NO.                                         TEST MODE DESCRIPTION
 1                                       Wireless charging Mode(Full load)
 2                                       Wireless charging Mode(half load)
 3                                       Wireless charging Mode(Null load)
Note:
1. The mode 1 was the worst case and only the data of the worst case record in this report.


                                                                        Report No.: AGC02724180304FE03
                                                                                            Page 8 of 29


5. SYSTEM TEST CONFIGURATION
5.1. CONFIGURATION OF EUT SYSTEM
Configure :



                EUT                  Accessory




5.2. EQUIPMENT USED IN EUT SYSTEM
Item        Equipment             Model No.             ID or Specification              Remark

         Wooden Wireless
  1                               XO-9549                2ALCFXO-9549                      EUT
          Charging Pad

                                                     100-240V 50/60Hz 0.15A
  2             Adapter        AS050-050-UA100                                           Support
                                                            DC5V 1A

         Wireless electronic
  3                                  --                Maximum power 5W                  Support
               Load


5.3. SUMMARY OF TEST RESULTS

  FCC RULES                          DESCRIPTION OF TEST                                RESULT
      §15.209                             Radiated Emission                             Compliant
      §15.215                              20dB bandwidth                               Compliant
      §15.207                             Conducted Emission                            Compliant


                                                                        Report No.: AGC02724180304FE03
                                                                                            Page 9 of 29


6. TEST FACILITY
     Test Site           Attestation of Global Compliance (Shenzhen) Co., Ltd
                        1-2F., Bldg.2, No.1-4, Chaxi Sanwei Technical Industrial Park, Gushu, Xixiang,
     Location           Bao’an District B112-B113, Bldg.12, Baoan Bldg Materials Center, No.1 of Xixiang
                        Inner Ring Road, Baoan District, Shenzhen 518012
 NVLAP LAB CODE         600153-0
Designation Number      CN5028
  FCC Test Firm
                        682566
Registration Number
                        Attestation of Global Compliance(Shenzhen) Co., Ltd is accredited by National
    Description
                        Voluntary Laboratory Accreditation program, NVLAP Code 600153-0


TEST EQUIPMENT OF RADIATED EMISSION TEST
   Equipment           Manufacturer           Model             S/N             Cal. Date      Cal. Due
TEST RECEIVER              R&S                ESCI             10096        Jun.20, 2017     Jun.19, 2018
   EXA Signal
                          Aglient            N9010A        MY53470504      Dec.08, 2017     Dec.07, 2018
    Analyzer
  preamplifier           ChengYi         EMC184045SE          980508       Sep.15, 2017     Sep.14, 2018
  Loop Antenna        A.H.Systems,Inc       SAS-562B             --        Feb. 27, 2018    Feb. 26, 2020
  Broadband
                   SCHWARZBECK              BBV 9718         9718-205       Jun.20, 2017     Jun.19, 2018
  Preamplifier
   ANTENNA         SCHWARZBECK             VULB9168           D69250       Sep.28, 2017     Sep.27, 2018


TEST EQUIPMENT OF CONDUCTED EMISSION TEST
    Equipment           Manufacturer         Model             S/N              Cal. Date      Cal. Due
 TEST RECEIVER               R&S              ESPI           101206        Jun.20, 2017      Jun.19, 2018
      LISN                   R&S            ESH2-Z5          100086        Aug.21, 2017     Aug.20, 2018


  AG                        °s — x m
                               Attestation of Global Compliance
                                                                                                                         Report No.: AGC02724180304FEO3
                                                                                                                                                             Page 10 of 29


    7. RADIATED EMISSION
    7.A1TEST LIMIT
    Standard FCC 15.209

    Frequency                                Distance                                                                Field Strengths Limit
    (MHz)                                    Meters                                       u V/m                                          dB(pV)/m
    0.009 ~ 0.490                            300                                          2400/F (KHz)
    0.490 ~ 1.705                            30                                           24000/F(kHz)
    1.705 ~ 30                               30                                           30
    30 ~ 88                                  3                                            100                                            40.0
    88 ~ 216                                 3                                            150                                            43.5
    216 ~ 960                                3                                            200                                            46.0
    960 ~ 1000                               3                                            500                                            54.0
    Above        1000                        3                                            Other:74.0 dB(uV)/m (Peak) 54.0 dB(uV)/m (Average)
    Remark:           (1) Emission level dBu V = 20 log Emission level u V/m
                      (2) The smaller limit shall apply at the cross point between two frequency bands.
                      (3) Distance is the distance in meters between the measuring instrument, antenna and the closest
                           point of any part of the device or system.




The results ’m,6tison|
                  o thisfeaost report refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days only. The document
is issued by/A C§€ this docu/m it cannot be reproduced except in full with our prior written permission. The more details and the authenticity of the report will be
confirmed tfittp://www.agc-«& t.com.
             o

Attestatic                   >ginpliance              Tel: +86—755 2908 1955            Fax: +86—755 2600 8484             E—mail: agc@agc—cert.com             @ 400 089 2118
                                                      Add: 2/F. , Building 2, No.1—4, Chaxi Sanwei Technical Industrial Park,Gushu, Xixiang, Bacan District, Shenzhen, Guangdong China


                                                                          Report No.: AGC02724180304FE03
                                                                                             Page 11 of 29


7.2. MEASUREMENT PROCEDURE
  1. The EUT was placed on the top of the turntable 0.8 or 1.5 meter above ground. The phase center of the
     receiving antenna mounted on the top of a height-variable antenna tower was placed 3 meters far away
     from the turntable.
  2. Power on the EUT and all the supporting units. The turntable was rotated by 360 degrees to determine
     the position of the highest radiation.
  3. The height of the broadband receiving antenna was varied between one meter and four meters above
     ground to find the maximum emissions field strength of both horizontal and vertical polarization.
  4. For each suspected emissions, the antenna tower was scan (from 1 M to 4 M) and then the turntable was
     rotated (from 0 degree to 360 degrees) to find the maximum reading.
  5. Set the test-receiver system to Peak or CISPR quasi-peak Detect Function with specified bandwidth
     under Maximum Hold Mode.
  6. In case the emission is lower than 30MHz, loop antenna has to be used for measurement and the
       recorded data should be QP measured by receiver. High - Low scan is not required in this case.



The following table is the setting of spectrum analyzer and receiver.
                Spectrum Parameter                                            Setting
                Start ~Stop Frequency                               9KHz~150KHz/RB 200Hz for QP
                Start ~Stop Frequency                               150KHz~30MHz/RB 9KHz for QP
                Start ~Stop Frequency                             30MHz~1000MHz/RB 120KHz for QP


                Receiver Parameter                                            Setting
                Start ~Stop Frequency                               9KHz~150KHz/RB 200Hz for QP
                Start ~Stop Frequency                               150KHz~30MHz/RB 9KHz for QP
                Start ~Stop Frequency                             30MHz~1000MHz/RB 120KHz for QP


                                                           Report No.: AGC02724180304FE03
                                                                              Page 12 of 29


7.3. TEST SETUP
                  Radiated Emission Test-Setup Frequency Below 30MHz




                   RADIATED EMISSION TEST SETUP 30MHz-1000MHz


                                                                               Report No.: AGC02724180304FE03
                                                                                                  Page 13 of 29


7.4. TEST RESULT
                                     RADIATED EMISSION BELOW 30MHZ

                                                  Factor          Level          Limit
Frequency                        Reading                                                       Margin
               Polarization                        dB           dB(uV/m)       dB(uV/m)                   Pass/Fail
   MHz                           dB(uV)                                                         dB
                                                  (1/m)           Peak         Average
   0.1485          Face           40.21           10.4            50.61         104.17         53.56        Pass
   0.1485          Side           35.34           10.4            45.74         104.17         58.43        Pass
Note: No other emissions found between lowest internal used/generated frequencies to 30MHz. The peak
level of the emission is less than the average limit, so the average level shall be less than the limit without test.
                                                        Face




                                                        Side


                            ®
  A\G                           # 7 H 1 i
                                       F‘q                  *




                                Attestation of Global Compliance
                                                                                                                         Report No.: AGC02724180304FEO3
                                                                                                                                                             Page 14 of 29


                                                         RADIATED EMISSION 30MHz— 1GHZ
    EUT :                           Wooden Wireless Charging Pad                          |Model Name. :                         XO—9549
    Temperature :                   20 °C                                                  Relative Humidtity:                   [48%
    Pressure :                      1010 hPa                                              Test Voltage            :              Normal
    Test Mode         :             Mode 1                                                 Polarization :                        Horizontal
                                [as( 1 v/m)]
                                     100

                                      30

                                      80

                                      T0


                                      60


                                I &
                                C     40


                                      30


                                      20


                                      10


                                       0


                                                                                      Frequency                                                 es


     Fredue"®Y
           Z
               potarization                    RESCDO
                                               dB(uV)
                                                                   Facljcéor
                                                                    (1/m)
                                                                                   dBL(i\\//G}‘Im)
                                                                                        PK
                                                                                                   dBIZLT/I/tm)
                                                                                                       oP
                                                                                                                Malgin
                                                                                                                  dB
                                                                                                                       pageypgi) MCYNt
                                                                                                                                  cm
                                                                                                                                       Angle
                                                                                                                                        deg

       55.220                  H                  8.8               16.7               25.5                40.0             14.5             Pass            100.0         141.8
      133.305                  H                 17.6               16.4               34.0                43.5              9.5             Pass            100.0         357.2
      213.815                  H                 11.2               14.2               25.4                43.5             181              Pass            150.0         3224
      295.295                  H                 10.3               17.5               27.8                46.0             18.2             Pass            100.0          50.2
      437.985                  H                  6.5               21.8               28.3                46.0             17.7             Pass            100.0         164.8
       62.495                  H                  8.6               15.9               24.5                40.0             15.5             Pass            200.0         207.6

    RESULT: PASS




The results ’m,6tison|
                  o thisfea es report refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days only. The document
is issued by/A (§€ this docu/t& it cannot be reproduced except in full with our prior written permission. The more details and the authenticity of the report will be
confirmed t;!?ttp://www.agc-«drS t.com.
            o

                                                       Tel: +86—755 2908 1955           Fax: +86—755 2600 8484             E—mail: agc@age—cert.com             @ 400 089 2118
                                                      Add: 2/F. , Building 2, No.1—4, Chaxi Sanwei Technical Industrial Park,Gushu, Xixiang, Bacan District, Shenzhen, Guangdong China


                            ®
  A\G                           # 7 H 1 i
                                       F‘q                      *




                                Attestation of Global Compliance
                                                                                                                             Report No.: AGC02724180304FEO3
                                                                                                                                                                 Page 15 of 29


    EUT :                          Wooden Wireless Charging Pad                               |Model Name. :                         XO—9549
    Temperature :                  20 C                                                        Relative Humidtity :                  (48%
    Pressure :                     1010 hPa                                                   Test Voltage             :             Normal
    Test Mode         :            Mode 1                                                      Polarization :                        Vertical
                               [as(uv/m)]
                                    100

                                     3

                                     80

                                      70

                                     60

                                I s
                                     40


                                     30

                                     30

                                      10

                                       0
                                        30            50                      100                                              500                  1000
                                                                                          Frequency                                                 [Dt#]
                                                      .               Factor               Level               Limit                   .                             .
     Fredue"°Y Polarization                   Fé%jfl'\’/‘?                dB            dB(uV/im) dB(uv/m) V8Y!" pass/rail HEOht ARC®
                                                                       (1/m)                 PK                 aP                                                                   9
       35.335                  V                 15.4                   16.3               31.7                40.0              8.3             Pass            100.0          31.0
       55.705                  V                 16.9                   16.6               33.5                40.0              6.5             Pass            100.0         304.2
      141.065                  V                 16.7                   16.6               33.3                43.5             10.2             Pass            100.0          38.4
      132.820                  V                 16.6                   16.4               33.0                43.5             10.5             Pass            100.0          86.5
       82.380                  V                 11.6                   12.3               23.9                40.0             16.1             Pass            100.0         279.0
      179.380                  V                 11.2                   14.6               25.8                43.5             17.7             Pass            100.0         310.6


    RESULT: PASS
    Note:

             Factor=Antenna Factor + Cable loss, Margin=Result—Limit.

            The "Factor" value can be calculated automatically by software of measurement system.




The results ’m,6tison|
                  o thisfea es report refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days only. The document
is issued by/A (§€ this docu/t& it cannot be reproduced except in full with our prior written permission. The more details and the authenticity of the report will be
confirmed t;!?ttp://www.agc-«drS t.com.
            o

                                                          Tel: +86—755 2908 1955            Fax: +86—755 2600 8484             E—mail: agc@age—cert.com             @ 400 089 2118
                                                          Add: 2/F. , Building 2, No.1—4, Chaxi Sanwei Technical Industrial Park,Gushu, Xixiang, Bacan District, Shenzhen, Guangdong China


                                                                      Report No.: AGC02724180304FE03
                                                                                         Page 16 of 29


8. 20DB BANDWIDTH
8.1. MEASUREMENT PROCEDURE
 1. The EUT was placed on the top of the turntable 0.8 meter above ground. The phase center of the
    receiving antenna mounted on the top of a height-variable antenna tower was placed 3 meters far away
    from the turntable.
 2, Set the EUT Work on operation frequency.
 3. Set Span = approximately 2 to 5 times the 20 dB bandwidth, centered on a channel
    The nominal IF filter bandwidth (3 dB RBW) shall be in the range of 1% to 5% of the OBW and video
    bandwidth (VBW) shall be approximately three times RBW; Sweep = auto; Detector function = peak
 4. Set SPA Trace 1 Max hold, then View.


8.2. TEST SET-UP (BLOCK DIAGRAM OF CONFIGURATION)


                                                        Report No.: AGC02724180304FE03
                                                                           Page 17 of 29


8.3. MEASUREMENT RESULTS

TEST ITEM                20DB BANDWIDTH

TEST MODULATION          FSK


                        Test Data (Hz)                                 Criteria
             Operate Channel                     848                    PASS


                               TEST PLOT OF BANDWIDTH


                                                                             Report No.: AGC02724180304FE03
                                                                                                Page 18 of 29


9. FCC LINE CONDUCTED EMISSION TEST
9.1. LIMITS OF LINE CONDUCTED EMISSION TEST

                                                               Maximum RF Line Voltage
             Frequency
                                                   Q.P.( dBuV)                         Average( dBuV)
          150kHz~500kHz                                66-56                                 56-46
           500kHz~5MHz                                   56                                   46
           5MHz~30MHz                                    60                                   50
Note:
1. The lower limit shall apply at the transition frequency.
2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50MHz.


9.2. BLOCK DIAGRAM OF LINE CONDUCTED EMISSION TEST



                  EUT & Support
                  Units


                                                                          Report No.: AGC02724180304FE03
                                                                                             Page 19 of 29


9.3. PRELIMINARY PROCEDURE OF LINE CONDUCTED EMISSION TEST
1. The equipment was set up as per the test configuration to simulate typical actual usage per the user’s
   manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is used and is
   placed on the ground plane as per ANSI C63.10 (see Test Facility for the dimensions of the ground plane
   used). When the EUT is a floor-standing equipment, it is placed on the ground plane which has a 3-12
   mm non-conductive covering to insulate the EUT from the ground plane.
2. Support equipment, if needed, was placed as per ANSI C63.10.
3. All I/O cables were positioned to simulate typical actual usage as per ANSI C63.10.
4. All support equipments received AC120V/60Hz power from a LISN, if any.
5. The EUT received charging voltage by adapter which received 120V/60Hzpower by a LISN..
6. The test program was started. Emissions were measured on each current carrying line of the EUT using a
   spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has two monitoring
   points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one with Line 1 connected to
   Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second scan had Line 1 connected to a
   50 ohm load and Line 2 connected to the Analyzer / Receiver.
7. Analyzer / Receiver scanned from 150 kHz to 30MHz for emissions in each of the test modes.
8. During the above scans, the emissions were maximized by cable manipulation.
9. The test mode(s) were scanned during the preliminary test.

Then, the EUT configuration and cable configuration of the above highest emission level were recorded for
reference of final testing.


9.4. FINAL PROCEDURE OF LINE CONDUCTED EMISSION TEST
1.   EUT and support equipment was set up on the test bench as per step 2 of the preliminary test.
2.    A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest emissions.
     Emission frequency and amplitude were recorded into a computer in which correction factors were used
     to calculate the emission level and compare reading to the applicable limit. If EUT emission level was
     less –2dB to the A.V. limit in Peak mode, then the emission signal was re-checked using Q.P and Average
     detector.
3.    The test data of the worst case condition(s) was reported on the Summary Data page.


                                                        Report No.: AGC02724180304FE03
                                                                           Page 20 of 29


9.5. TEST RESULT OF LINE CONDUCTED EMISSION TEST
                           LINE CONDUCTED EMISSION TEST-L




RESULT: PASS


                                            Report No.: AGC02724180304FE03
                                                               Page 21 of 29


               LINE CONDUCTED EMISSION TEST-N




RESULT: PASS


                                    Report No.: AGC02724180304FE03
                                                       Page 22 of 29


APPENDIX A: PHOTOGRAPHS OF TEST SETUP
FCC RADIATED EMISSION TEST SETUP BELOW 1GHZ


                                 Report No.: AGC02724180304FE03
                                                    Page 23 of 29


FCC LINE CONDUCTED EMISSION TEST SETUP


                           Report No.: AGC02724180304FE03
                                              Page 24 of 29


APPENDIX B: PHOTOGRAPHS OF EUT
        ALL VIEW OF EUT


                     Report No.: AGC02724180304FE03
                                        Page 25 of 29


 TOP VIEW OF EUT




BOTTOM VIEW OF EUT


                    Report No.: AGC02724180304FE03
                                       Page 26 of 29


FRONT VIEW OF EUT




BACK VIEW OF EUT


                    Report No.: AGC02724180304FE03
                                       Page 27 of 29


LEFT VIEW OF EUT




RIGHT VIEW OF EUT


                         Report No.: AGC02724180304FE03
                                            Page 28 of 29


  OPEN VIEW OF EUT




INTERNAL VIEW OF EUT-1


                            Report No.: AGC02724180304FE03
                                               Page 29 of 29


INTERNAL VIEW OF EUT-2




                         Antenna




INTERNAL VIEW OF EUT-3




----END OF REPORT---



Document Created: 2018-04-23 13:41:12
Document Modified: 2018-04-23 13:41:12