Bluetooth controllable 2ch 0-10V controller                                                                                            www.casambi.com

Description
CBU-ASR is a Bluetooth controllable, Casambi enabled two channel 0-10V controller for dim-
mable LED loads and luminaires. It is powered by an external 12-24 VDC Class 2 power supply.

CBU-ASR can control two channels making it an ideal partner tunable white (TW) applications.
The two channels can be configured also to operate individually. The device also has a control
port for an external relay and a 0-24 VDC analog input which can be used with different kinds
of sensors.

CBU-ASR is an ideal partner for 24 VDC Class 2 power packs with internal relay. CBU-ASR is
protected against overvoltage, overcurrent and short circuit situations.                                                                                                    Compatible devices:
CBU-PWM4 can be controlled with Casambi app which can be downloaded free of charge                                                                                          iPhone 4S or later
from Apple App Store and Google Play Store.                                                                                                                                 iPad 3 or later
                                                                                                                                                                            iPod Touch 5th gen or later
Different Casambi enabled products can be used from a simple one luminaire direct control to
a complete and full featured light control system where up to 127 units form automatically an                                                                               Android 4.4 or later devices produced
intelligent mesh network.                                                                                                                                                   after 2013 with full BT 4.0 support



Wiring diagram                                                                                                                                 Technical data

                                                                                                                                                 Input
                                                                                                                                                 Voltage range:			                   12-24 VDC, Class 2
                                                                                                                                                 No-load input current:			           40 mA
 12-24 VDC Class 2
 power supply                                                                                                                                    0-10V output
                                                                                                                                                 Output voltage:			                  0-10 VDC, adjustable
                                                                                                 0-10V CH1           0-10V ch 1                  Max. output current:			             5 mA, sinking and sourcing
                                                                      2ch 0-10V controller
                                              INPUT 12-24 VDC




                                                                                                 0-10V CH2           0-10V ch 2
                                                                                       CBU-ASR




                                                                                                  RETURN             Return                      Relay control output
                                                                                                    RELAY            Relay control               Output voltage:			                  12-24 VDC, same as input
                                                                                                  SENSOR             Sensor input                Max. output current:			             200 mA

                                                                                                                                                 Sensor input
                                                                                                                                                 Input voltage range:			             0-24 VDC
                                                                                                                                                 Input resistance:			                81,5 kΩ

Dimensions                                                                                                                                       Radio transceiver
                                                                                                                                                 Operating frequencies:			           2.401-2.483 Ghz
                                                                                                                                                 Maximum output power:			            typ. +0 dBm, +/-3dBm
                                       72.6                                                                    Length 2.2 in                     Operating conditions
                                       64.6                                                                    Width 1.2 in                      Ambient temperature, ta:			  -13...+113°F
                                       56.0                                                                    Heigth 0.7 in                     Max. case temperature, tc:		 +167°F
                                                                                                                                                 Storage temperature:			-13...+167°F
                                                                                                        15.0        30.0
                                                                OUTPUT 12-24 VDC




                                                                                                                                                 Max. relative humidity:			   0...80%, non-cond.
                     INPUT 12-24 VDC




                                                                  Max. 6 A total




    3.5
               Tc*                                                                                                                               Connectors
                                                                                                        15.0                    18.0
                                                                                                                                                 Wire range, solid & stranded:		 0,75 - 1,5 mm2
                                                                                                                                                 				14 - 22 AWG
                                                                                                                                                 Wire strip length:			           6 - 7 mm
    Dimensions are in mm.                                * Tc point is on bottom side                                                            Tightening force:			            0.4 Nm / 2.6 Lb-in

                                                                                                                                                 Mechanical data
                                                                                                                                                 Dimensions:				 2.2 x 1.2 x 0.7 inch
                                                                                                                                                 				            72.6 x 30.0 x 18.0 mm
                                                                                                                                                 Weight:				0.8 oz

                                                                                                                                                 FCC ID:				2ALA3-CBUASR
                                                                                                                                                 IC:				22496-CBUASR




                                                                                                               Lighting control for the Modern World


Installation
Connect a Class 2 power supply with 12-24 VDC output voltage to the input connector of CBU-ASR. Make sure that the cable polarity is correct.

The products has one return line which is shared between the two 0-10V outputs, relay control output and sensor input.

The two 0-10V outputs can be configured for differet functions, such as 2 channel tunable white, or 1-2 jointly and individually dimmable channels. The
standard configuration when delivered is 2 channel TW, but the configuration can be changed by the end user from Casambi App.

CBU-ASR, as any other Casambi product, should not be placed in a metal enclosure, such as metal junction boxes. Metal will effectively block all radio
signals which are crucial to the operation of the product. If the product will have to installed into a junction box, make sure to use a plastic junction box.

CBU-ASR is a UL Listed Open-Type device which means that it will have to be used together with a Class 2 power supply with maximum output power
of 100 VA. Because the maximum voltage is only 24 VDC, the product can be installed outside of junction box. Make sure to comply with National Electric
Code in installation and when selecting installation wires.

Range
The range between two CBU-ASR units or between a CBU-ASR and a smart phone can vary a lot depending on obstacles and surrounding material. In
open air the range between two CBU-ASRs can be in excess of 300 ft, but if the unit is encapsulated into a metal structure, the range can be only few
feet. For this reason, it is very important to make sure that the product is not installed into a metal case. Also thorough testing is high suggested.

Casambi uses mesh network technology so each CBU-ASR acts also as a repeater. When testing the network, it is important to test that each unit can
be controlled from any point of the network covered area.

Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.

Radiation Exposure Statement for FCC
This device complies with FCC radiation exposure limits for an uncontrolled environment. This device shall be installed and operated with a minimum
distance of 0.8” (2cm) between users or bystanders and the device.

Warning
Changes or modifications not expressly approved by Casambi Technologies Oy could void the user’s authority to operate the equipment.

FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of
the following measures:

• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.

Radiation Exposure Statement for Canada
This device complies with Industry Canada’s licence-exempt RSSs. Operation is subject to the following two conditions:

(1) This device may not cause interference
(2) This device must accept any interference, including interference that may cause undesired operation of the device.

This equipment is exempt from the routine RF exposure evaluation requirements of RSS-102. This equipment should be installed and operated with a
minimum distance of 20 cm between the antenna and the user or bystanders.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux
conditions suivantes:

(1) l’appareil ne doit pas produire de brouillage;
(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.

Ce matériel n’est pas sujet à l’évaluation habituelle d’exposition RF selon RSS102. Ce matériel devrait être installé et exploité en gardant une distance
minimale de 20 cm entre l’antenne et l’utilisateur ou les spectateurs.




Information in this document is subject to change.                Casambi Technologies Oy                                       Copyright Casambi Technologies Oy 2017.
CBU-ASR User Guide v1.0 USA and Canada                       Linnoitustie 4, 02600 Espoo, Finland



Document Created: 2018-04-18 17:53:59