MPE Report

FCC ID: 2AL6K-R8188NU3

RF Exposure Info

Download: PDF
FCCID_4170856

    /                                 Shenzhen Global Test Service Co.,Ltd.

@15
                              No.7—101 and 8A¥—104, Building 7 and 8, DCC Cultural and Creative Garden, No.98, Pingxin North Road,
                              Shangmugu Community, Pinghu Street, Longgang District, Shenzhen, Guangdong
     v


                                                                    RF Exposure evaluation

Report Reference No...................... :                              GTSR19010008—WLANO2
76o | » oo :                                                             2ALOK—R8188NU3
Compiled by
( position+printed name+signature)..:                                    File administrators Jimmy Wang

Supervised by
( position+printed name—+signature)..:                                   Test Engineer Aaron Tan


Approved by
( position+printed name+signature)..:                                    Manager Jason Hu


DAte Of ISSUQ@......222222222222rrrrrrrrrrrrrkkkkk, :                    Jan.12, 2019

Representative Laboratory Name .:                                        Shenzhen Global Test Service Co.,Ltd.
                                                                         No.7—101 and 8¥—104, Building 7 and 8, DCC Cultural and Creative
favrelele—r— :                                                           Garden, No.98, Pingxin North Road, Shangmugu Community,
                                                                         Pinghu Street, Longgang District, Shenzhen, Guangdong

Applicant‘s name ............................ :                          Shenzhen Bilian Electronic Co.,Ltd.
AQQUF@SS .....2....2222 000066 e 66e e e e e e e e e e e e e e ks :      Building B1,Zhongxing Industrial Zone,Juling,.Jutang Community,
                                                                         Guanlan street,Longhua New District, Shenzhen, Guangdong,
                                                                         P.R.China
Test specification ........................... :
                                                                         47CFR §1.1310
ojr|qleeir oo :                                                          47CFR §2.1091
                                                                         KDB447498 vO6
TRF OFIGIN@tOF ......22........0000 es :                                 Shenzhen Global Test Service Co.,Ltd.
Master TRF...........026ee en en e e ks :                                Dated 2014—12
Shenzhen Global Test Service Co.,Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non—commercial purposes as long as the
Shenzhen Global Test Service Co.,Ltd. is acknowledged as copyright owner and source of the material.
Shenzhen Global Test Service Co.,Ltd. takes no responsibility for and will not assume liability for damages
resulting from the reader‘s interpretation of the reproduced material due to its placement and context.
Test item description .................... :                             IEEE 802.11b/g/n 1T1R USB WiFi Module
Trad@ M@rK ................000eeer es :                                  LB—LINK
ManufaCturer ................ccle es :                                   Shenzhen Bilian Electronic Co.,Ltd.
Model/Type reference...................... :                             BL—R8188NU3
Listed MOGU@IS ..................ccc es :                                /
Modulation TYD@ ... :                                                    IEEE 802.11b/802.11g/802.11n
Operation Frequency................}. :                                  From 2412 — 2462MHz
Hardware VersIiOn ...............l}, :                                   VO.1
SOftWare VerSsION ..............c.ll k62 :                               V33
Aelulle :                                                                DC 5V from USB port
RE@SUIH. . 22222222000 0000 6e e e rr e e rr e e e e e e e e e e e e :   PASS


Report No.: GTSR19010008-WLAN02                                                                                       Page 2 of 8

                                    TEST REPORT

                                                                                             Jan. 12, 2019
 Test Report No. :             GTSR19010008-WLAN02              ______________________________________________________________________________________________


                                                                                              Date of issue


  Equipment under Test          :      IEEE 802.11b/g/n 1T1R USB WiFi Module


  Model /Type                   :      BL-R8188NU3


  Listed Models                 :      /


  Applicant                     :      Shenzhen Bilian Electronic Co.,Ltd.


                                :      Building B1,Zhongxing Industrial Zone,Juling,Jutang
  Address                              Community, Guanlan street,Longhua New District,
                                       Shenzhen, Guangdong, P.R.China


  Manufacturer                  :      Shenzhen Bilian Electronic Co.,Ltd.


                                :      Building B1,Zhongxing Industrial Zone,Juling,Jutang
  Address                              Community, Guanlan street,Longhua New District,
                                       Shenzhen, Guangdong, P.R.China




          Test Result:                                          PASS


   The test report merely corresponds to the test sample.
   It is not permitted to copy extracts of these test result without the written permission of the test
   laboratory.


 Report No.: GTSR19010008-WLAN02                      Page 3 of 8

                                         Contents

1.     SUMM ARY                                                         4

1.1.   EUT configuration                                            4
1.2.   Product Description                                          4

2.     TEST ENVIRONMENT                                                 5

2.1.   Address of the test laboratory                               5
2.2.   Test Facility                                                5
2.3.   Environmental conditions                                     5
2.4.   Statement of the measurement uncertainty                     5

3.     METHOD OF MEASUREM ENT                                           6

3.1.   Applicable Standard                                          6
3.2.   Requirement                                                  6
3.3.   Limit                                                        6
3.4.   MPE Calculation Method                                       7
3.5.   Antenna Information                                          7

4.     EVALU ATION RESULT                                               8

4.1.   Standalone MPE                                               8
4.2.   Simultaneous transmission MPE Considerations                 8

5.     CONCLUSION                                                       8


 Report No.: GTSR19010008-WLAN02                                                 Page 4 of 8

1. SUMMARY

1.1. EUT configuration
The following peripheral devices and interface cables were connected during the measurement:

● - supplied by the manufacturer

○ - supplied by the lab

○                                        Length (m) :   /
                                         Shield :       /
                                         Detachable :   /


1.2. Product Description

    Name of EUT           IEEE 802.11b/g/n 1T1R USB WiFi Module
    Trade Mark:           /
    Model Number          BL-R8188NU3
    Listed Models         /
    Power Supply          DC 5V from USB port
    WLAN                  Supported 802.11b/802.11g/802.11n
    Modulation Type       IEEE 802.11b: DSSS(CCK,DQPSK,DBPSK)
                          IEEE 802.11g: OFDM(64QAM, 16QAM, QPSK, BPSK)
                          IEEE 802.11n HT20: OFDM (64QAM, 16QAM, QPSK,BPSK)
                          IEEE 802.11n HT40: OFDM (64QAM, 16QAM, QPSK,BPSK)
    Operation frequency   IEEE 802.11b:2412-2462MHz
                          IEEE 802.11g:2412-2462MHz
                          IEEE 802.11n HT20:2412-2462MHz
                          IEEE 802.11n HT40:2422-2452MHz
    Antenna gain          1.31 dbi
    Antenna Type          External antenna


 Report No.: GTSR19010008-WLAN02                                                            Page 5 of 8

2. TEST ENVIRONMENT

2.1. Address of the test laboratory

      Shenzhen Global Test Service Co.,Ltd.
      1F, Building No. 13A, Zhonghaixin Science and Technology City, No.12,6 Road, Ganli Industrial Park,
      Buji Street, Longgang District, Shenzhen, Guangdong


2.2. Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

FCC-Registration No.: 165275
Shenzhen Global Test Service Co.,Ltd EMC Laboratory has been registered and fully described in a report
filed with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is maintained
in our files.


CNAS-Lab Code: L8169
Shenzhen Global Test Service Co.,Ltd. has been assessed and proved to be in compliance with CNAS-
CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC 17025: 2005
General Requirements) for the Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No.: 4758.01

Shenzhen Global Test Service Co.,Ltd. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing.


2.3. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:

  Temperature:                                  15-35 °C

  Humidity:                                      30-60 %

  Atmospheric pressure:                       950-1050mbar


2.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to TR-100028-01” Electromagnetic compatibility
and Radio spectrum Matters (ERM);Uncertainties in the measurement of mobile radio equipment
characteristics; Part 1” and TR-100028-02 “Electromagnetic compatibility and Radio spectrum Matters
(ERM);Uncertainties in the measurement of mobile radio equipment characteristics; Part 2 “ and is
documented in the Shenzhen Global Test Service Co.,Ltd quality system acc. to DIN EN ISO/IEC 17025.
Furthermore, component and process variability of devices similar to that tested may result in additional
deviation. The manufacturer has the sole responsibility of continued compliance of the device.

Hereafter the best measurement capability for Shenzhen GTS laboratory is reported:

                         Test Items                             Measurement Uncertainty        Notes
      Transmitter power conducted                                       0.57 dB                 (1)

          (1) This uncertainty represents an expanded uncertainty expressed at approximately the 95%
               confidence level using a coverage factor of k=2.


 Report No.: GTSR19010008-WLAN02                                                           Page 6 of 8

3. Method of measurement

3.1. Applicable Standard

According to §1.1307(b)(1), systems operating under the provisions of this section shall be operated in a
manner that ensures that the public is not exposed to radio frequency energy level in excess of the
Commission’s guidelines.
According to §1.1310 and §2.1091 RF exposure is calculated.
KDB447498 v06: Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization
Policies


3.2. Requirement

Systems operating under the provisions of FCC 47 CFR section shall be operated in a manner that ensures
that the public is not exposed to radio frequency energy level in excess of the Commission’s guidelines.
 In accordance with 47 CFR FCC Part 2 Subpart J, section 2.1091 this device has been defined as mobile
device whereby a distance of 0.2m normally can be maintained between the user and the device, and below
RF Permissible Exposure limit shall comply with.
In accordance with KDB447498D01 for Simultaneous transmission MPE test exclusion applies when the sum
of the MPE ratios for all simultaneous transmitting antennas incorporated in a host device, based on the
calculated/estimated, numerically modeled or measured field strengths or power density, is ≤ 1.0. The MPE
ratio of each antenna is determined at the minimum test separation distance required by the operating
configurations and exposure conditions of the host device, according to the ratio of field strengths or power
density to MPE limit, at the test frequency. Either the maximum peak or spatially averaged results from
measurements or numerical simulations may be used to determine the MPE ratios. Spatial averaging does not
apply when MPE is estimated using simple calculations based on far-field plane-wave equivalent conditions.
The antenna installation and operating requirements for the host device must meet the minimum test
separation distances required by all antennas, in both standalone and simultaneous transmission operations,
to satisfy compliance.


3.3. Limit
Limits for Maximum Permissible Exposure (MPE)/Controlled Exposure
                                                                                Averaging
  Frequency         Electric Field     Magnetic Field     Power Density
                                                                                  Time
 Range(MHz)         Strength(V/m)      Strength(A/m)        (mW/cm²)
                                                                                 (minute)
                      Limits for Occupational/Controlled Exposure
   0.3 – 3.0
                         614                 1.63              (100) *               6
   3.0 – 30
                        1842/f              4.89/f            (900/f2)*              6
   30 – 300
                         61.4               0.163                1.0                 6
  300 – 1500
                          /                    /                f/300                6
    1500 –
                          /                    /                  5                  6
   100,000

Limits for Maximum Permissible Exposure (MPE)/Uncontrolled Exposure
                                                                   Averaging
  Frequency       Electric Field   Magnetic Field Power Density
                                                                     Time
 Range(MHz)      Strength(V/m)     Strength(A/m)       (mW/cm²)
                                                                    (minute)
                    Limits for Occupational/Controlled Exposure
   0.3 – 3.0
                      614               1.63             (100) *      30
   3.0 – 30
                      824/f            2.19/f           (180/f2)*     30
   30 – 300
                      27.5             0.073               0.2        30
  300 – 1500
                         /                /              f/1500       30
    1500 –
                         /                /                1.0        30
   100,000

F=frequency in MHz
*=Plane-wave equivalent power density


 Report No.: GTSR19010008-WLAN02                                                         Page 7 of 8

3.4. MPE Calculation Method

Predication of MPE limit at a given distance
Equation from page 18 of OET Bulletin 65, Edition 97-01

S=PG/4πR²
Where: S=power density
   P=power input to antenna
   G=power gain of the antenna in the direction of interest relative to an isotropic radiator
   R=distance to the center of radiation of the antenna

As declared by the Applicant, the EUT transmits with the maximum soure-baed Duty Cycle of 100%-see the
User manual, and the EUT is a wireless device used in a mobile application, at least 20 cm from any body part
of the user or nearby persons; from the maximum EUT RF output power, the minimum mobile separation
distance, r =20cm, as well as the gain of the used antenna is 1.06dBi for WLAN, and the power drift from
Turn-up Procedure provide by manufacturer as following states, the RF power density can be obtained..


3.5. Antenna Information
BL-R8812AF1 can only use antennas certificated as follows provided by manufacturer;

                                              Antenna type
   Internal       Antenna Identification                         Operate frequency       Maximum antenna
                                              and antenna
 Identification     in Internal photos                                 band                   gain
                                                number
                                                                  2.4GHz – 2.4835
  Antenna 1              2.4G Wifi          Enternal Antenna           GHz                 1.31dBi(Max.)


 Report No.: GTSR19010008-WLAN02                                                         Page 8 of 8

4. Evaluation Result

4.1. Standalone MPE


                                               Max       Antenna
                              Max tune up
             Target power                     Output      Gain       Power Density
  Modulati                        power                                                  Limit
             W/ tolerance                    power to   (Numeric)     at R=20cm                     Result
  on Type                     tolerance(dB                                             (mW/cm2)
                (dBm)                        antenna                  (mW/cm2)
                                    m)
                                              (mW)
  802.11b        15±1              16         39.81       1.352          0.0107           1.0        Pass
  802.11g        14±1              15          31.62      1.352          0.0085           1.0        Pass
  802.11n
                 13±1              14          25.11      1.352          0.0068           1.0        Pass
   (HT20)
   802.11
                 12±1              13          19.95      1.352          0.0054           1.0        Pass
  n(HT40)



4.2. Simultaneous transmission MPE Considerations

According to KDB447498 :For mobile exposure host platform to qualify for simultaneous transmission MPE
test exclusion, all transmitters and antennas in the host must be either evaluated for MPE compliance, by
measurement or computational modeling, or qualify for the standalone MPE test exclusion in section 7.1.
Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneous
transmitting antennas incorporated in a host device, based on the calculated/estimated, numerically modeled
or measured field strengths or power density, is ≤ 1.0.
This means that:
∑ of MPE ratios ≤ 1.0

The EUT is Not Applicable.


5. Conclusion
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment.

                        .....................End of Report.........................



Document Created: 2019-03-28 05:09:28