Test Report BT LE

FCC ID: 2AL5E-SX

Test Report

Download: PDF
FCCID_4240351

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB




                                                  FCC TEST REPORT

                                                                 For

                                  Shenzhen IVANTE Technolgy co., LTD.
                                                   Bluetooth earphone
                                                       Test Model: S2
               Additional Model No.: S3, S5, S6, S3P, S8P, S2P, S8, S9, SX



 Prepared for                             :    Shenzhen IVANTE Technolgy co., LTD.
 Address                                  :    3/F, NO.18 Chuangye 2 Road, Zhang’er Village, Zhangbei
                                               Community, Longcheng Sub-District, Longgang District, Shenzhen,
                                               China

 Prepared by                              :    Shenzhen LCS Compliance Testing Laboratory Ltd.
                                               1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue, Bao'an
 Address                                  :
                                               District, Shenzhen, Guangdong, China
 Tel                                      :    (+86)755-82591330
 Fax                                      :    (+86)755-82591332
 Web                                      :    www.LCS-cert.com
 Mail                                     :    webmaster@LCS-cert.com

 Date of receipt of test sample           :    December 28, 2018
 Number of tested samples                 :    1
 Serial number                            :    Prototype
 Date of Test                             :    December 28, 2018 ~ March 25, 2019
 Date of Report                           :    March 25, 2019




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 1 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB


                                                  FCC TEST REPORT
                                              FCC CFR 47 PART 15 C(15.247)

 Report Reference No. ................. : LCS181228028AEB

 Date of Issue ................................... : March 25, 2019

 Testing Laboratory Name............. : Shenzhen LCS Compliance Testing Laboratory Ltd.

 Address ........................................... : 1/F., Xingyuan Industrial Park, Tongda Road, Bao'an Avenue,
                                                       Bao'an District, Shenzhen, Guangdong, China
 Testing Location/ Procedure ........... Full application of Harmonised standards ■
                                                     :
                                                       Partial application of Harmonised standards □
                                                       Other standard testing method □
 Applicant’s Name .......................... : Shenzhen IVANTE Technolgy co., LTD.

 Address ........................................... : 3/F, NO.18 Chuangye 2 Road, Zhang’er Village, Zhangbei
                                                       Community, Longcheng Sub-District, Longgang District, Shenzhen,
                                                       China
 Test Specification

 Standard .......................................... : FCC CFR 47 PART 15 C(15.247)

 Test Report Form No. ................... : LCSEMC-1.0

 TRF Originator ................................ : Shenzhen LCS Compliance Testing Laboratory Ltd.

 Master TRF ..................................... : Dated 2011-03
 Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
 This publication may be reproduced in whole or in part for non-commercial purposes as long as the
 Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright owner and source of the
 material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes no responsibility for and will not
 assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
 placement and context.
 EUT Description. ........................... : Bluetooth earphone

 Trade Mark ...................................... : IVANTE

 Model/ Type reference .................... : S2

 Ratings ............................................ : BOX: DC 3.7V by battery(900mAh)
                                                   Recharged by DC 5V/50mA
                                                   EARBUDS: DC 3.7V by battery(45mAh)
 Result ............................................ : Positive

             Compiled by:                                    Supervised by:                               Approved by:




         Lh Li/ Administrators                   Calvin Weng/ Technique principal                    Gavin Liang/ Manager


   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 2 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB


                                                      FCC -- TEST REPORT

                                                                                                March 25, 2019
       Test Report No. :                           LCS181228028AEB                               Date of issue



   Type / Model...........................          : S2

   EUT.........................................     : Bluetooth earphone


   Applicant...............................         : Shenzhen IVANTE Technolgy co., LTD.
   Address..................................        : 3/F, NO.18 Chuangye 2 Road, Zhang’er Village, Zhangbei
                                                      Community, Longcheng Sub-District, Longgang District, Shenzhen,
                                                      China
   Telephone...............................         : /
   Fax..........................................    : /


   Manufacturer........................             : Shenzhen IVANTE Technolgy co., LTD.
   Address...................................       : 3/F, NO.18 Chuangye 2 Road, Zhang’er Village, Zhangbei
                                                      Community, Longcheng Sub-District, Longgang District, Shenzhen,
                                                      China
   Telephone...............................         : /
   Fax..........................................    : /


   Factory...................................       : Shenzhen IVANTE Technolgy co., LTD.
   Address...................................       : 3/F, NO.18 Chuangye 2 Road, Zhang’er Village, Zhangbei
                                                      Community, Longcheng Sub-District, Longgang District, Shenzhen,
                                                      China
   Telephone...............................         : /
   Fax..........................................    : /




                              Test Result                                                        Positive

   The test report merely corresponds to the test sample.
   It is not permitted to copy extracts of these test result without the written permission of the test laboratory.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 3 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB




                                                     Revision History

           Revision                         Issue Date                         Revisions                        Revised By
              000                        March 25, 2019                       Initial Issue                     Gavin Liang




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 4 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                      FCC ID: 2AL5E-SX                        Report No.: LCS181228028AEB




                                                                 TABLE OF CONTENTS

1. GENERAL INFORMATION .................................................................................................................................... 6
   1.1. DESCRIPTION OF DEVICE (EUT) ........................................................................................................................ 6
   1.2 SUPPORT EQUIPMENT LIST .................................................................................................................................. 6
   1.3 EXTERNAL I/O CABLE .......................................................................................................................................... 6
   1.4 DESCRIPTION OF TEST FACILITY ......................................................................................................................... 7
   1.5 STATEMENT OF THE MEASUREMENT UNCERTAINTY ........................................................................................... 7
   1.6 MEASUREMENT UNCERTAINTY ............................................................................................................................ 7
   1.7. DESCRIPTION OF TEST MODES .......................................................................................................................... 7
2. TEST METHODOLOGY ......................................................................................................................................... 9
   2.1. EUT CONFIGURATION ........................................................................................................................................ 9
   2.2. EUT EXERCISE ................................................................................................................................................... 9
   2.3. GENERAL TEST PROCEDURES ........................................................................................................................... 9
3. SYSTEM TEST CONFIGURATION .................................................................................................................... 10
   3.1. JUSTIFICATION .................................................................................................................................................. 10
   3.2. EUT EXERCISE SOFTWARE .............................................................................................................................. 10
   3.3. SPECIAL ACCESSORIES .................................................................................................................................... 10
   3.4. BLOCK DIAGRAM/SCHEMATICS......................................................................................................................... 10
   3.5. EQUIPMENT MODIFICATIONS ............................................................................................................................ 10
   3.6. TEST SETUP ...................................................................................................................................................... 10
4. SUMMARY OF TEST RESULTS ........................................................................................................................ 11
5. TEST RESULT ....................................................................................................................................................... 12
   5.1. ON TIME AND DUTY CYCLE .............................................................................................................................. 12
   5.2. MAXIMUM CONDUCTED OUTPUT POWER MEASUREMENT............................................................................... 13
   5.3. POWER SPECTRAL DENSITY MEASUREMENT .................................................................................................. 14
   5.4. 6 DB SPECTRUM BANDWIDTH MEASUREMENT ................................................................................................ 15
   5.5. RADIATED EMISSIONS MEASUREMENT............................................................................................................. 16
   5.6. CONDUCTED SPURIOUS EMISSIONS AND BAND EDGES TEST ......................................................................... 25
   5.7. AC POWER LINE CONDUCTED EMISSIONS ...................................................................................................... 26
   5.8. RESTRICT-BAND BAND-EDGE MEASUREMENTS ............................................................................................... 28
   5.9. ANTENNA REQUIREMENTS ................................................................................................................................ 30




      This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                     Page 5 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB




   1.                    GENERAL INFORMATION

  1.1. Description of Device (EUT)

     EUT                                     : Bluetooth earphone

     Test Model                              : S2

     Model List No.                          : S2, S3, S5, S6, S3P, S8P, S2P, S8, S9, SX

     Model Declaration                       : PCB board, structure and internal of these model(s) are the same,
                                               So no additional models were tested.

     Power Supply                            : BOX: DC 3.7V by battery(900mAh)
                                               Recharged by DC 5V/50mA
                                               EARBUDS: DC 3.7V by battery(45mAh)

     Hardware version                        : RD-RT-S2-A3
     Software version                        : RD-RT-S2-MS-V5.0

     Bluetooth

     Operation frequency                     : 2402MHz-2480MHz

     Bluetooth Version                       : Bluetooth V5.0(LE&2LE)

     Channel Number                          : 79 channels for Bluetooth V5.0 (BT Classics)
                                               40 channels for Bluetooth V5.0 (BT LE)

     Channel Spacing                         : 1MHz for Bluetooth V5.0 (BT Classics)
                                               2MHz for Bluetooth V5.0 (BT LE)

     Modulation Type                         : GFSK, π/4-DQPSK, 8-DPSK for V5.0 (BT Classics)
                                               GFSK for Bluetooth V5.0 (BT LE)

     Antenna Description                     : Internal Antenna, 2.0dBi


  1.2 Support equipment List

           Manufacturer                Description                  Model              Serial Number            Certificate
               Lenovo                        PC                        B470                    --                   DOC
               Lenovo              AC/DC ADAPTER                ADP-90DDB                      --                   DOC
             SAMSUNG                 Power Adapter             ETA0U42CBC             RT1CC19bS/7-E             FCC sDOC


  1.3 External I/O Cable

                I/O Port Description                          Quantity                                 Cable
                      USB port                                     1                                      --


   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 6 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB

  1.4 Description of Test Facility

    FCC Registration Number. is 254912.
    Industry Canada Registration Number. is 9642A-1.
    ESMD Registration Number. is ARCB0108.
    UL Registration Number. is 100571-492.
    TUV SUD Registration Number. is SCN1081.
    TUV RH Registration Number. is UA 50296516-001.
    NVLAP Registration Code is 600167-0.

    The 3m-Semi anechoic test site fulfils CISPR 16-1-4 according to ANSI C63.10:2013 and CISPR
    16-1-4:2010 SVSWR requirement for radiated emission above 1GHz.

  1.5 Statement of the Measurement Uncertainty

    The data and results referenced in this document are true and accurate. The reader is cautioned that
    there may be errors within the calibration limits of the equipment and facilities. The measurement
    uncertainty was calculated for all measurements listed in this test report acc. To CISPR 16 – 4
    “Specification for radio disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty
    in EMC Measurements” and is documented in the LCS quality system acc. To DIN EN ISO/IEC 17025.
    Furthermore, component and process variability of devices similar to that tested may result in additional
    deviation. The manufacturer has the sole responsibility of continued compliance of the device.

  1.6 Measurement Uncertainty

                     Test Item                       Frequency Range                      Uncertainty                Note
                                                       9KHz~30MHz                            3.10dB                   (1)
                                                     30MHz~200MHz                            2.96dB                   (1)
             Radiation Uncertainty           :      200MHz~1000MHz                           3.10dB                   (1)
                                                      1GHz~26.5GHz                           3.80dB                   (1)
                                                     26.5GHz~40GHz                           3.90dB                   (1)
            Conduction Uncertainty :                  150kHz~30MHz                           1.63dB                   (1)
               Power disturbance             :       30MHz~300MHz                            1.60dB                   (1)

    (1). This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
    level using a coverage factor of k=2.

  1.7. Description of Test Modes


    The EUT has been tested under operating condition.
    This test was performed with EUT in X, Y, Z position and the worst case was found when EUT in X
    position.
    Worst-case mode and channel used for 150 KHz-30 MHz power line conducted emissions was the mode
    and channel with the highest output power, which was determined to be LE mode (Low Channel).
    Worst-case mode and channel used for 9 KHz-1000 MHz radiated emissions was the mode and channel
    with the highest output power, that was determined to be LE mode(Low Channel).
    Worst-Case data rates were utilized from preliminary testing of the Chipset, worst-case data rates used
   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 7 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB

    during the testing are as follows:

    LE: 1 Mbps, GFSK
    2LE: 2 Mbps, GFSK
    Pre-test AC conducted emission at both charge from power adapter and PC mode, recorded worst case.
    Pre-test AC conducted emission at both voltage AC 120V/60Hz and AC 240V/50Hz, recorded worst case.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 8 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB

2. TEST METHODOLOGY

    All measurements contained in this report were conducted with ANSI C63.10-2013, American National
    Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.
    The radiated testing was performed at an antenna-to-EUT distance of 3 meters. All radiated and
    conducted emissions measurement was performed at Shenzhen LCS Compliance Testing Laboratory Ltd.

  2.1. EUT Configuration
    The EUT configuration for testing is installed on RF field strength measurement to meet the Commissions
    requirement and operating in a manner that intends to maximize its emission characteristics in a
    continuous normal application.

  2.2. EUT Exercise
    The EUT was operated in the engineering mode to fix the TX frequency that was for the purpose of the
    measurements.
    According to FCC’s request, Test Procedure KDB558074 D01 DTS Meas. Guidance is required to be
    used for this kind of FCC 15.247 digital modulation device.
    According to its specifications, the EUT must comply with the requirements of the Section 15.203, 15.205,
    15.207, 15.209 and 15.247 under the FCC Rules Part 15 Subpart C.

  2.3. General Test Procedures

   2.3.1 Conducted Emissions

    The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the requirements in
    Section 6.2.1 of ANSI C63.10-2013 Conducted emissions from the EUT measured in the frequency range
    between 0.15 MHz and 30MHz using Quasi-peak and average detector modes.

   2.3.2 Radiated Emissions

    The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable shall rotate 360
    degrees to determine the position of maximum emission level. EUT is set 3m away from the receiving
    antenna, which varied from 1m to 4m to find out the highest emission. And also, each emission was to be
    maximized by changing the polarization of receiving antenna both horizontal and vertical. In order to find
    out the maximum emissions, exploratory radiated emission measurements were made according to the
    requirements in Section 6.3 of ANSI C63.10-2013.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 9 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB

3. SYSTEM TEST CONFIGURATION

  3.1. Justification
    The system was configured for testing in a continuous transmit condition. The duty cycle is 100% and the
    average correction factor is 0.

  3.2. EUT Exercise Software
    The system was configured for testing in a continuous transmits condition and change test channels
    by software (ADB command_v1.0) provided by applicant.

  3.3. Special Accessories

            Manufacturer                Description                 Model            Serial Number            Certificate
                Lenovo                        PC                     B470                    --                   DOC
                Lenovo              AC/DC ADAPTER               ADP-90DDB                    --                   DOC


  3.4. Block Diagram/Schematics
    Please refer to the related document

  3.5. Equipment Modifications
    Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification on the EUT.

  3.6. Test Setup
    Please refer to the test setup photo.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 10 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                             FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB


4. SUMMARY OF TEST RESULTS

                                        Applied Standard: FCC Part 15 Subpart C
          FCC Rules                              Description of Test                             Result                 Remark
                /                            On Time and Duty Cycle                                  /               Appendix B.1
          §15.247(b)                  Maximum Conducted Output Power                           Compliant             Appendix B.2
          §15.247(e)                          Power Spectral Density                           Compliant             Appendix B.3
        §15.247(a)(2)                              6dB Bandwidth                               Compliant             Appendix B.4
                                                                                                                     Appendix B.5
    §15.209, §15.247(d)                 Conducted Spurious Emissions                           Compliant
                                                                                                                     Appendix B.6
    §15.209, §15.247(d)                   Radiated Spurious Emissions                          Compliant                 Note 1
           §15.205                        Emissions at Restricted Band                         Compliant             Appendix B.7
          §15.207(a)                    AC Mains Conducted Emissions                           Compliant                 Note 1
           §15.203                            Antenna Requirements                             Compliant                 Note 1
     §15.247(i)§2.1093                              RF Exposure                                Compliant                 Note 2


Remark:

1. Note 1 – Test results inside test report;
2. Note 2 – Test results in other test report (RF Exposure Evaluation Report);




    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 11 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB

5. TEST RESULT

  5.1. On Time and Duty Cycle

   5.1.1. Standard Applicable

    None; for reporting purpose only.

   5.1.2. Measuring Instruments and Setting

    Please refer to equipment list in this report. The following table is the setting of the spectrum analyzer.

   5.1.3. Test Procedures

    1. Set the center frequency of the spectrum analyzer to the transmitting frequency;
    2. Set the span=0MHz, RBW=8MHz, VBW=50MHz, Sweep time=20.80ms;
    3. Detector = peak;
    4. Trace mode = Single hold.

   5.1.4. Test Setup Layout




   5.1.5. EUT Operation during Test

    The EUT was programmed to be in continuously transmitting mode.

   5.1.6. Test result

    For reporting purpose only.
    Please refer to Appendix B.1




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 12 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                             FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB


   5.2. Maximum Conducted Output Power Measurement

   5.2.1. Standard Applicable

    For systems using digital modulation in the 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz bands:
    1 Watt. As an alternative to a peak power measurement, compliance with the one Watt limit can be based
    on a measurement of the maximum conducted output power. Maximum Conducted Output Power is
    defined as the total transmit power delivered to all antennas and antenna elements averaged across all
    symbols in the signaling alphabet when the transmitter is operating at its maximum power control level.
    Power must be summed across all antennas and antenna elements. The average must not include any
    time intervals during which the transmitter is off or is transmitting at a reduced power level. If multiple
    modes of operation are possible (e.g., alternative modulation methods), the maximum conducted output
    power is the highest total transmit power occurring in any mode.

   5.2.2. Test Procedures

    The transmitter output (antenna port) was connected to the spectrum analyzer.
    According to KDB558074 D01 DTS Measurement Guidance Section 9.1 Maximum peak conducted output
    power 9.1.1.
    This procedure shall be used when the measurement instrument has available a resolution bandwidth that
    is greater than the DTS bandwidth.
    a) Set the RBW ≥ DTS bandwidth.
    b) Set VBW ≥ 3  RBW.
    c) Set span ≥ 3 x RBW
    d) Sweep time = auto couple.
    e) Detector = peak.
    f) Trace mode = max hold.
    g) Allow trace to fully stabilize.
    h) Use peak marker function to determine the peak amplitude level.

   5.2.3. Test Setup Layout




   5.2.4. EUT Operation during Test

    The EUT was programmed to be in continuously transmitting mode.

   5.2.5. Test Result of Maximum Conducted Output Power

    PASS
    Please refer to Appendix B.2

Remark:

1. Test results including cable loss;




    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 13 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                             FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB


   5.3. Power Spectral Density Measurement

   5.3.1. Standard Applicable

    According to §15.247(e): For digitally modulated systems, the power spectral density conducted from the
    intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time
    interval of continuous transmission.

   5.3.2. Measuring Instruments and Setting

    Please refer to equipment list in this report. The following table is the setting of Spectrum Analyzer.

    5.3.3. Test Procedures

    1. Use this procedure when the maximum peak conducted output power in the fundamental emission is
    used to demonstrate compliance.
    2. The power was monitored at the coupler port with a Spectrum Analyzer. The power level was set to the
    maximum level.
    3. Set the RBW = 3 kHz.
    4. Set the VBW ≥ 3*RBW
    5. Set the span to 1.5 times the DTS channel bandwidth.
    6. Detector = peak.
    7. Sweep time = auto couple.
    8. Trace mode = max hold.
    9. Allow trace to fully stabilize.
    10. Use the peak marker function to determine the maximum power level.
    11. If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat.
    12. The resulting peak PSD level must be 8 dBm.

   5.3.4. Test Setup Layout




   5.3.5. EUT Operation during Test

    The EUT was programmed to be in continuously transmitting mode.


   5.3.6. Test Result of Power Spectral Density

    PASS
    Please refer to Appendix B.3

Remark:

1. Test results including cable loss;
    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 14 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                             FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB

   5.4. 6 dB Spectrum Bandwidth Measurement

   5.4.1. Standard Applicable

    According to §15.247(a) (2): For digital modulation systems, the minimum 6 dB bandwidth shall be at least
    500 kHz.

   5.4.2. Measuring Instruments and Setting

    Please refer to equipment list in this report. The following table is the setting of the Spectrum Analyzer.

            Spectrum Parameter                                  Setting
            Attenuation                                         Auto
            RBW                                                 100KHz
            VBW                                                 ≥3*RBW
            Span Frequency                                      > RBW
            Detector                                            Peak
            Trace                                               Max Hold
            Sweep Time                                          1ms

   5.4.3. Test Procedures

    1. The transmitter output (antenna port) was connected to the spectrum analyzer in peak hold mode.
    2. The resolution bandwidth and the video bandwidth were set according to KDB558074.
    3. Measured the spectrum width with power higher than 6dB below carrier.

   5.4.4. Test Setup Layout




   5.4.5. EUT Operation during Test

    The EUT was programmed to be in continuously transmitting mode.

   5.4.6. Test Result of 6dB Spectrum Bandwidth

    PASS
    Please refer to Appendix B.4

Remark:

1. Test results including cable loss;




    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 15 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB

  5.5. Radiated Emissions Measurement

   5.5.1. Standard Applicable

    15.205 (a) Except as shown in paragraph (d) of this section, only spurious emissions are permitted in any
    of the frequency bands listed below:

                   MHz                            MHz                            MHz                     GHz
                0.090-0.110                  16.42-16.423                     399.9-410                4.5-5.15
                \1\ 0.495-0.505              16.69475-16.69525                608-614                  5.35-5.46
                2.1735-2.1905                16.80425-16.80475                960-1240                 7.25-7.75
                4.125-4.128                  25.5-25.67                       1300-1427                8.025-8.5
                4.17725-4.17775              37.5-38.25                       1435-1626.5              9.0-9.2
                4.20725-4.20775              73-74.6                          1645.5-1646.5            9.3-9.5
                6.215-6.218                  74.8-75.2                        1660-1710                10.6-12.7
                6.26775-6.26825              108-121.94                       1718.8-1722.2            13.25-13.4
                6.31175-6.31225              123-138                          2200-2300                14.47-14.5
                8.291-8.294                  149.9-150.05                     2310-2390                15.35-16.2
                8.362-8.366                  156.52475-156.52525              2483.5-2500               17.7-21.4
                8.37625-8.38675              156.7-156.9                      2690-2900                22.01-23.12
                8.41425-8.41475              162.0125-167.17                  3260-3267                23.6-24.0
                12.29-12.293.                167.72-173.2                     3332-3339                31.2-31.8
                12.51975-12.52025            240-285                          3345.8-3358              36.43-36.5
                12.57675-12.57725            322-335.4                        3600-4400                (\2\)
                13.36-13.41
    \1\ Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
    \2\ Above 38.6
    According to §15.247 (d): 20dBc in any 100 kHz bandwidth outside the operating frequency band. In case
    the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) limit in the table
    below has to be followed.

                Frequencies                                Field Strength                        Measurement Distance
                   (MHz)                                 (microvolts/meter)                            (meters)
                0.009~0.490                                 2400/F(KHz)                                  300
                0.490~1.705                                24000/F(KHz)                                   30
                1.705~30.0                                       30                                       30
                   30~88                                        100                                       3
                  88~216                                        150                                       3
                  216~960                                       200                                       3
                 Above 960                                      500                                       3

   5.5.2. Measuring Instruments and Setting

    Please refer to equipment list in this report. The following table is the setting of spectrum analyzer and
    receiver.

     Spectrum Parameter                                       Setting
     Attenuation                                              Auto
     Start Frequency                                          1000 MHz
     Stop Frequency                                           10th carrier harmonic
     RB / VB (Emission in restricted band)                    1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average
     RB / VB (Emission in non-restricted band)                1MHz / 1MHz for Peak, 1 MHz / 1/B kHz for Average

    Receiver Parameter                                           Setting
    Attenuation                                                  Auto
    Start ~ Stop Frequency                                       9kHz~150kHz / RB/VB 200Hz/1KHz for QP/AVG
    Start ~ Stop Frequency                                       150kHz~30MHz / RB/VB 9kHz/30KHz for QP/AVG
    Start ~ Stop Frequency                                       30MHz~1000MHz / RB/VB 120kHz/1MHz for QP

   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 16 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB



   5.5.3. Test Procedures


    1) Sequence of testing 9 kHz to 30 MHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or described by
    manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions.
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0°to 315°using 45°steps.
    --- The antenna height is 0.8 meter.
    --- At each turntable position the analyzer sweeps with peak detection to find the maximum of all
    emissions

    Final measurement:
    --- Identified emissions during the premeasurement the software maximizes by rotating the turntable
    position (0°to 360°) and by rotating the elevation axes (0°to 360°).
    --- The final measurement will be done in the position (turntable and elevation) causing the highest
    emissions with QPK detector.
    --- The final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin to
    the limit and limit will be recorded. Also a plot with the graph of the premeasurement and the limit will be
    stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 17 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB



    2) Sequence of testing 30 MHz to 1 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or described by
    manufacturer.
    --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground plane.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0°to 315°using 45°steps.
    --- The antenna is polarized vertical and horizontal.
    --- The antenna height changes from 1 to 3 meter.
    --- At each turntable position, antenna polarization and height the analyzer sweeps three times in peak to
    find the maximum of all emissions.

    Final measurement:
    --- The final measurement will be performed with minimum the six highest peaks.
    --- According to the maximum antenna and turntable positions of premeasurement the software maximize
    the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4 meter.
    --- The final measurement will be done with QP detector with an EMI receiver.
    --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization, turntable
    angle, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of the
    premeasurement with marked maximum final measurements and the limit will be stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 18 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB



    3) Sequence of testing 1 GHz to 18 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or described by
    manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 3 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The turntable rotates from 0°to 315°using 45°steps.
    --- The antenna is polarized vertical and horizontal.
    --- The antenna height scan range is 1 meter to 2.5 meter.
    --- At each turntable position and antenna polarization the analyzer sweeps with peak detection to find the
    maximum of all emissions.

    Final measurement:
    --- The final measurement will be performed with minimum the six highest peaks.
    --- According to the maximum antenna and turntable positions of premeasurement the software maximize
    the peaks by changing turntable position (± 45°) and antenna movement between 1 and 4 meter. This
    procedure is repeated for both antenna polarizations.
    --- The final measurement will be done in the position (turntable, EUT-table and antenna polarization)
    causing the highest emissions with Peak and Average detector.
    --- The final levels, frequency, measuring time, bandwidth, turntable position, EUT-table position, antenna
    polarization, correction factor, margin to the limit and limit will be recorded. Also a plot with the graph of
    the premeasurement with marked maximum final measurements and the limit will be stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 19 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB



    4) Sequence of testing above 18 GHz

    Setup:
    --- The equipment was set up to simulate a typical usage like described in the user manual or described by
    manufacturer.
    --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
    --- If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
    --- Auxiliary equipment and cables were positioned to simulate normal operation conditions
    --- The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
    --- The measurement distance is 1 meter.
    --- The EUT was set into operation.

    Premeasurement:
    --- The antenna is moved spherical over the EUT in different polarizations of the antenna.

    Final measurement:
    --- The final measurement will be performed at the position and antenna orientation for all detected
    emissions that were found during the premeasurements with Peak and Average detector.
    --- The final levels, frequency, measuring time, bandwidth, correction factor, margin to the limit and limit
    will be recorded. Also a plot with the graph of the premeasurement and the limit will be stored.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 20 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB


   5.5.4. Test Setup Layout




    Above 18 GHz shall be extrapolated to the specified distance using an extrapolation factor of 20
    dB/decade form 3m to 1m.
    Distance extrapolation factor = 20 log (specific distanc [3m] / test distance [1m]) (dB);
    Limit line = specific limits (dBuV) + distance extrapolation factor [6 dB].

   5.5.5. EUT Operation during Test

    The EUT was programmed to be in continuously transmitting mode.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 21 of 33


shENzHEN LCs CoMPLIaNCE TESTING LaBORATORY LTD.                             CC iD: patse—sX             Report No.: LCS181228008AEB

   5.5.6. Results of Radiated Emissions (9 KHz~80MHz)

             Temperature                             23.8°C                   Humidity                       54%
             Test Engineer                         AKING JIN              Configurations                     BT LE

               Freq.                        Level              Over Limit            Over Limit               R         k
              (MHz)                        (dBuv)                 (dB)                  (dBuV)                    eme
                    —                         —                     —                      —                 See Nove

    Note:
    The amplitude of spurious emissions which are attenuated by more than 20 dB below the permissible
    value has no need to be reported.
    Distance extrapolation factor = 40 log {specific distance / test distance) (dB);
    Limit line = spesific limits (dBuV) + distance extrapolation factor.

   5.5.7. Results of Radiated Emissions {30MHz~1G—z)

             Temperature                            23.8°C                   Humidity                        54%
             Test Engineer                         AKING JIN             Configurations                  LE (Low CH)


Test result for LE (Low Channe})

Horizontal
                    q Lovel (atuntim
                 Ton
                 con                                                                                    ¢ec pant thn

                 100
                 son
                 200
                 190
                        "sa          5o                  To            z00                        soo               Todo
                                                              Frequency (itt)
             pors                                  rortzouras
                              rreq   Resding          Cabmos Antfes Measured              hinit Over          Remark
                              rm=          apuv          as     an/a        amuy/m       dmuy/m         am
                          108.57           an.79       a.ee      arae        a7.es        43.50    —i5.es          or
                          eos.s?           ai.os       a.ss     an.as        ea.as       a2.s0     —20.41         or
                          ear.se          20.05        a.se      anlss       az.sa       a6.00     —19.47         or
                          ase.on          rcuas        naz      oaalas       as.os       as.00      —7.92         or
                          a08.30          2i.i4        nar       asea        ar.se       a6.00      —a.486        or
                          261.20           s.52        a.on      eias        a9.02       sa.00°    —24.98         or
                   1. All readings are Qussi—pesk velues.
             2. Measured= Reading + Antenna Pactor + Cable toss
             3. the emission thet ate 20db blow the offficial limit are not reported




   This report shallnot be reproduced except inful, without the writen approval ofShenthen LCS Compliance Testing Laboratory Lid.
                                                              Page2? of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                             FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB

Vertical




Note:
1). Pre-scan all modes and recorded the worst case results in this report (LE (Low Channel)).
2). Emission level (dBuV/m) = 20 log Emission level (uV/m).
3.). Corrected Reading: Antenna Factor + Cable Loss + Read Level - Preamp Factor = Level.




    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 23 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                             FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB

   5.5.8. Results for Radiated Emissions (Above 1GHz)

    LE
    Channel 0 / 2402 MHz
                                 Ant.        Pre.       Cab.
   Freq.         Reading                                            Measured          Limit       Margin
                                 Fac.        Fac.       Loss                                                   Remark           Pol.
   MHz            dBuV                                               dBuV/m          dBuV/m        dB
                                dB/m          dB         dB
  4804.00         59.01         33.06       35.04       3.94          60.97           74.00        -13.03        Peak       Horizontal
  4804.00         41.36         33.06       35.04       3.94          43.32           54.00        -10.68     Average       Horizontal
  4804.00         54.26         33.06       35.04       3.94          56.22           74.00        -17.78        Peak         Vertical
  4804.00         41.05         33.06       35.04       3.94          43.01           54.00        -10.99     Average         Vertical

    Channel 19 / 2440 MHz
                                 Ant.       Pre.       Cab.
    Freq.        Reading                                          Measured          Limit        Margin
                                 Fac.       Fac.       Loss                                                   Remark            Pol.
    MHz           dBuV                                             dBuV/m          dBuV/m         dB
                                dB/m         dB         dB
  4880.00          57.78        33.16      35.15       3.93          59.72          74.00        -14.28         Peak        Horizontal
  4880.00          42.00        33.16      35.15       3.93          43.94          54.00        -10.06       Average       Horizontal
  4880.00          55.82        33.16      35.15       3.93          57.76          74.00        -16.24         Peak          Vertical
  4880.00          42.06        33.16      35.15       3.93          44.00          54.00        -10.00       Average         Vertical

    Channel 39 / 2480 MHz
                                 Ant.       Pre.       Cab.
    Freq.        Reading                                          Measured          Limit        Margin
                                 Fac.       Fac.       Loss                                                   Remark            Pol.
    MHz           dBuV                                             dBuV/m          dBuV/m         dB
                                dB/m         dB         dB
  4960.00          55.71        33.26      35.14       3.98          57.81          74.00        -16.19         Peak        Horizontal
  4960.00          41.40        33.26      35.14       3.98          43.50          54.00        -10.50       Average       Horizontal
  4960.00          56.36        33.26      35.14       3.98          58.46          74.00        -15.54         Peak          Vertical
  4960.00          39.26        33.26      35.14       3.98          41.36          54.00        -12.64       Average         Vertical


Notes:
1). Measuring frequencies from 9 KHz~10th harmonic or 26.5GHz (which is less), No emission found between
lowest internal used/generated frequency to 30MHz.
2). Radiated emissions measured in frequency range from 9 KHz~10th harmonic or 26.5GHz (which is less)
were made with an instrument using Peak detector mode.
3). Data of measurement within this frequency range shown “ --- ” in the table above means the reading of
emissions are attenuated more than 20dB below the permissible limits or the field strength is too small to be
measured.




    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 24 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB

  5.6. Conducted Spurious Emissions and Band Edges Test

   5.6.1. Standard Applicable

    According to §15.247 (d): In any 100 kHz bandwidth outside the frequency band in which the spread
    spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is
    produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the
    band that contains the highest level of the desired power, based on either an RF conducted or a radiated
    measurement. Attenuation below the general limits specified in Section 15.209(a) is not required. In
    addition, radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), must also
    comply with the radiated emission limits specified in Section 15.209(a) (see Section 15.205(c)).

   5.6.2. Measuring Instruments and Setting

    Please refer to equipment list in this report. The following table is the setting of the spectrum analyzer.

     Spectrum Parameter                                                     Setting
     Detector                                                               Peak
     Attenuation                                                            Auto
     RB / VB (Emission in restricted band)                                  100KHz/300KHz
     RB / VB (Emission in non-restricted band)                              100KHz/300KHz


   5.6.3. Test Procedures

    The transmitter output is connected to a spectrum analyzer. The resolution bandwidth is set to 100 kHz.
    The video bandwidth is set to 300 kHz
    The spectrum from 9 kHz to 25.0GHz is investigated with the transmitter set to the lowest, middle, and
    highest channels.

   5.6.4. Test Setup Layout

    This test setup layout is the same as that shown in section 5.4.4.

   5.6.5. EUT Operation during Test

    The EUT was programmed to be in continuously transmitting mode.

   5.6.6. Test Results of Conducted Spurious Emissions

    PASS
    Please refer to Appendix B.5 for conducted spurious emissions;
    Please refer to Appendix B.6 for conducted band edge emission.

    Remark:
    1). Test results including cable loss;
    2). “---“means that the fundamental frequency not for 15.209 limits requirement.
    3). Not recorded emission from 9 KHz to 30 MHz as emission level at least 20dBc lower than emission
    limit.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 25 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB

  5.7. AC Power Line Conducted Emissions

   5.7.1 Standard Applicable

    According to §15.207 (a): For an intentional radiator which is designed to be connected to the public utility
    (AC) power line, the radio frequency voltage that is conducted back onto the AC power line on any
    frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed 250 microvolts (The limit
    decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50 MHz). The limits at
    specific frequency range are listed as follows:

                        Frequency Range                                         Limits (dBμV)
                              (MHz)                                   Quasi-peak                         Average
                           0.15 to 0.50                                66 to 56                          56 to 46
                             0.50 to 5                                   56                                46
                              5 to 30                                    60                                50

              * Decreasing linearly with the logarithm of the frequency

   5.7.2 Block Diagram of Test Setup




   5.7.3 Test Results

    PASS.
    The test data please refer to following page.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 26 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB

AC Conducted Emission of charge from Power Adapter mode @ AC 120V/60Hz @ GFSK (worst case)

Line




Neutral




   ***Note: Pre-scan all modes and recorded the worst case results in this report.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 27 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB

  5.8. Restrict-band Band-edge Measurements

   5.8.1 Standard Applicable
   In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated
   intentional radiator is operating, the radio frequency power that is produced by the intentional radiator shall
   be at least 20 dB below that in the 100 kHz bandwidth within the band that contains the highest level of the
   desired power, based on either an RF conducted or a radiated measurement, provided the transmitter
   demonstrates compliance with the peak conducted power limits. If the transmitter complies with the
   conducted power limits based on the use of RMS averaging over a time interval, as permitted under
   paragraph (b)(3) of this section, the attenuation required under this paragraph shall be 30 dB instead of 20
   dB. Attenuation below the general limits specified in §15.209(a) is not required. In addition, radiated
   emissions which fall in the restricted bands, as defined in §15.205(a), must also comply with the radiated
   emission limits specified in §15.209(a) (see §15.205(c)).

   5.8.2. Test Setup Layout




   5.8.3. Measuring Instruments and Setting
   Please refer to equipment list in this report. The following table is the setting of Spectrum Analyzer.

   5.8.4. Test Procedures

   According to KDB 558074 D01 for Antenna-port conducted measurement. Antenna-port conducted
   measurements may also be used as an alternative to radiated measurements for demonstrating
   compliance in the restricted frequency bands. If conducted measurements are performed, then proper
   impedance matching must be ensured and an additional radiated test for cabinet/case spurious emissions
   is required.
   1). Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
   2). Remove the antenna from the EUT and then connect to a low loss RF cable from the antenna port to an
   EMI test receiver, then turn on the EUT and make it operate in transmitting mode. Then set it to Low
   Channel and High Channel within its operating range, and make sure the instrument is operated in its linear
   range.
   3). Set both RBW and VBW of spectrum analyzer to 100 kHz with a convenient frequency span including
   100kHz bandwidth from band edge, for Radiated emissions restricted band RBW=1MHz, VBW=3MHz for
   peak detector and RBW=1MHz, VBW=1/B for AV detector.
   4). Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the
   graph with marking the highest point and edge frequency.
   5). Repeat above procedures until all measured frequencies were complete.
   6). Measure the conducted output power (in dBm) using the detector specified by the appropriate
   regulatory agency (see 12.2.2, 12.2.3, and 12.2.4 for guidance regarding measurement procedures for
   determining quasi-peak, peak, and average conducted output power, respectively).
   7). Add the maximum transmit antenna gain (in dBi) to the measured output power level to determine the
   EIRP level (see 12.2.5 for guidance on determining the applicable antenna gain)
   8). Add the appropriate maximum ground reflection factor to the EIRP level (6 dB for frequencies ≤ 30 MHz,
   4.7 dB for frequencies between 30 MHz and 1000 MHz, inclusive and 0 dB for frequencies > 1000 MHz).
   9). For devices with multiple antenna-ports, measure the power of each individual chain and sum the EIRP
   of all chains in linear terms (e.g., Watts, mW).
   10). Convert the resultant EIRP level to an equivalent electric field strength using the following relationship:

   E = EIRP – 20log D + 104.77=EIRP+95.23

   Where:
   E = electric field strength in dBμV/m,

   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 28 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                             FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB

   EIRP = equivalent isotropic radiated power in dBm
   D = specified measurement distance in meters.
   11). Since the out-of-band characteristics of the EUT transmit antenna will often be unknown, the use of a
   conservative antenna gain value is necessary. Thus, when determining the EIRP based on the measured
   conducted power, the upper bound on antenna gain for a device with a single RF output shall be selected
   as the maximum in-band gain of the antenna across all operating bands, or 2 dBi, whichever is greater.
   However, for devices that operate in multiple frequency bands while using the same transmit antenna, the
   highest gain of the antenna within the operating band nearest in frequency to the restricted band emission
   being measured may be used in lieu of the overall highest gain when the emission is at a frequency that is
   within 20 percent of the nearest band edge frequency, but in no case shall a value less than 2 dBi be used.
   12). Compare the resultant electric field strength level to the applicable regulatory limit.
   13). Perform radiated spurious emission test duress until all measured frequencies were complete.

   5.8.5 Test Results


     PASS
     Please refer to Appendix B.7

Remark:
1). Test results including cable loss;
2). “---“means that the fundamental frequency not for 15.209 limits requirement;
3). The average measurement was not performed when the peak measured data under the limit of average
detection.
4). Detector AV is setting spectrum/receiver. RBW=1MHz/VBW=10Hz/Sweep time=Auto/Detector=Peak.
5). Since the out-of-band characteristics of the EUT transmit antenna will often be unknown, the use of a
conservative antenna gain value is necessary. Thus, when determining the EIRP based on the measured
conducted power, the upper bound on antenna gain for a device with a single RF output shall be selected as
the maximum in-band gain of the antenna across all operating bands, or 2 dBi, whichever is greater. However,
for devices that operate in multiple frequency bands while using the same transmit antenna, the highest gain of
the antenna within the operating band nearest in frequency to the restricted band emission being measured
may be used in lieu of the overall highest gain when the emission is at a frequency that is within 20 percent of
the nearest band edge frequency, but in no case shall a value less than 2 dBi be used.




    This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                  Page 29 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB

  5.9. Antenna Requirements

   5.9.1 Standard Applicable

    According to antenna requirement of §15.203.
    An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
    responsible party shall be used with the device. The use of a permanently attached antenna or of an
    antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply
    with the provisions of this Section. The manufacturer may design the unit so that a broken antenna can be
    re-placed by the user, but the use of a standard antenna jack or electrical connector is prohibited. This
    requirement does not apply to carrier current devices or to devices operated under the provisions of
    Sections 15.211, 15.213, 15.217, 15.219, or 15.221. Further, this requirement does not apply to
    intentional radiators that must be professionally installed, such as perimeter protection systems and some
    field disturbance sensors, or to other intentional radiators which, in accordance with Section 15.31(d),
    must be measured at the installation site. However, the installer shall be responsible for ensuring that the
    proper antenna is employed so that the limits in this Part are not exceeded.

    And according to §15.247(4)(1), system operating in the 2400-2483.5MHz bands that are used
    exclusively for fixed, point-to-point operations may employ transmitting antennas with directional gain
    greater than 6dBi provided the maximum peak output power of the intentional radiator is reduced by 1 dB
    for every 3 dB that the directional gain of the antenna exceeds 6dBi.

   5.9.2 Antenna Connected Construction
   5.9.2.1. Standard Applicable

    According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
    furnished by the responsible party shall be used with the device.

   5.9.2.2. Antenna Connector Construction

    The gains of antenna used for transmitting is 2.0dBi, and the antenna is an internal antenna touch to PCB
    board and no consideration of replacement. Please see EUT photo for details.

   5.9.2.3. Results: Compliance.

    Measurement
    The antenna gain of the complete system is calculated by the difference of radiated power in EIRP and
    the conducted power of the module.
    Conducted power refers ANSI C63.10:2013 Output power test procedure for DTS devices.
    Radiated power refers to ANSI C63.10:2013 Radiated emissions tests.
    Measurement parameters

                                             Measurement parameter
                               Detector:                                                       Peak
                             Sweep Time:                                                        Auto
                         Resolution bandwidth:                                                 1MHz
                           Video bandwidth:                                                    3MHz
                             Trace-Mode:                                                      Max hold

      Note: The antenna gain of the complete system is calculated by the difference of radiated power in
             EIRP and the conducted power of the module.




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 30 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB

    Limits

                                    FCC                                                         ISED
                                                           Antenna Gain
                                                               6 dBi


                                                   Lowest Channel             Middle Channel            Highest Channel
               Tnom                Vnom
                                                     2402 MHz                   2440 MHz                   2480 MHz
             Conducted power [dBm]
                 Measured with                            0.781                     0.973                       1.228
               GFSK modulation
              Radiated power [dBm]
                 Measured with                            2.771                     2.899                       3.137
               GFSK modulation
              Gain [dBi] Calculated                       1.990                     1.926                       1.909
                        Measurement uncertainty                                  ± 1.6 dB (cond.) / ± 3.8 dB (rad.)




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 31 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                              FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB


6. LIST OF MEASURING EQUIPMENTS

Item   Equipment                   Manufacturer              Model No.               Serial No.           Last Cal.         Next Cal.
1      Power Meter                 R&S                       NRVS                    100444               2018-06-16        2019-06-15
2      Power Sensor                R&S                       NRV-Z81                 100458               2018-06-16        2019-06-15
3      Power Sensor                R&S                       NRV-Z32                 10057                2018-06-16        2019-06-15
       ESA-E SERIES
4                        Agilent                             E4407B                  MY41440754           2018-06-16        2019-06-15
       SPECTRUM ANALYZER
5      MXA Signal Analyzer         Agilent                   N9020A                  MY49100040           2018-06-16        2019-06-15
6      SPECTRUM ANALYZER R&S                                 FSP                     100503               2018-06-16        2019-06-15
       3m Semi Anechoic
7                                  SIDT FRANKONIA            SAC-3M                  03CH03-HY            2018-06-16        2019-06-15
       Chamber
8      Positioning Controller      MF                        MF-7082                 /                    2018-06-16        2019-06-15
9      EMI Test Software           AUDIX                     E3                      N/A                  N/A               N/A
10     EMI Test Receiver           R&S                       ESR 7                   101181               2018-06-16        2019-06-15
11     AMPLIFIER                   QuieTek                   QTK-A2525G              CHM10809065          2018-06-16        2019-06-15
12     Active Loop Antenna         SCHWARZBECK               FMZB 1519B              00005                2018-06-22        2019-06-21
13     By-log Antenna              SCHWARZBECK               VULB9163                9163-470             2018-05-02        2019-05-01
14     Horn Antenna                SCHWARZBECK               BBHA 9120 D             9120D-1925           2018-07-02        2019-07-01
15     Broadband Horn Antenna SCHWARZBECK                    BBHA 9170               791                  2017-09-21        2020-09-20
16     Broadband Preamplifier      SCHWARZBECK               BBV 9719                9719-025             2017-09-21        2020-09-20
17     RF Cable-R03m               Jye Bao                   RG142                   CB021                2018-06-16        2019-06-15
18     RF Cable-HIGH               SUHNER                    SUCOFLEX 106            03CH03-HY            2018-06-16        2019-06-15
19     TEST RECEIVER               R&S                       ESCI                    101142               2018-06-16        2019-06-15
20     RF Cable-CON                UTIFLEX                   3102-26886-4            CB049                2018-06-16        2019-06-15
21     10dB Attenuator             SCHWARZBECK               MTS-IMP136              261115-001-0032 2018-06-16             2019-06-15
22     Artificial Mains            R&S                       ENV216                  101288               2018-06-16        2019-06-15
                                 JS Tonscend
23     RF Control Unit                            JS0806-2          178060073       2018-06-16                              2019-06-15
                                 Corporation
     JS1120-3 BT/WIFI Test JS Tonscend
24                                                JS1120-3          /               N/A                                     N/A
     Software                    Corporation
Note: All equipment is calibrated through GUANGZHOU LISAI CALIBRATION AND TEST CO.,LTD.




     This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                   Page 32 of 33


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID: 2AL5E-SX              Report No.: LCS181228028AEB


7. TEST SETUP PHOTOGRAPHS OF EUT

    Please refer to separated files for Test Setup Photos of the EUT.


8. EXTERIOR PHOTOGRAPHS OF THE EUT

    Please refer to separated files for External Photos of the EUT.


9. INTERIOR PHOTOGRAPHS OF THE EUT

    Please refer to separated files for Internal Photos of the EUT.




                      ----------------THE END OF TEST REPORT---------------




   This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd.
                                                                 Page 33 of 33



Document Created: 2019-04-12 14:05:04
Document Modified: 2019-04-12 14:05:04

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC