RF Exposure Info

FCC ID: 2AL3B-DT-LIGHT

RF Exposure Info

Download: PDF
FCCID_4364062

                                      Shenzhen Huaxia Testing Technology Co., Ltd
                                      1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District,
                                      Shenzhen, China
                                      Telephone:       +86-755-26648640
                                      Fax:             +86-755-26648637                    Report Template Version: V03
                                      Website:         www.cqa-cert.com                    Report Template Revision Date: Mar.1st, 2017



                  RF Exposure Evaluation Report
Report No. :                          CQASZ20190600466E-02
Applicant:                            ShenZhen Doctors of Intelligence & Technology Co.,Ltd.
Address of Applicant:                 4F,Building 2,Science & Technology Industrial Park,Pingshan Xili, Nanshan
                                      District, Shenzhen, China
Equipment Under Test (EUT):
Product:                              Smart Light
Model No.:                            DT-light
Brand Name:                           DoHome

FCC ID:                               2AL3B-DT-LIGHT
Standards:                            47 CFR Part 1.1307
                                      47 CFR Part 1.1310
                                      KDB447498D01 General RF Exposure Guidance v06

Date of Receipt:                      2019-06-13
Date of Test:                         2019-06-13 to 2019-06-16
Date of Issue:                        2019-06-27
Test Result :                         PASS*




Tested By:
                                                      (Daisy Qin)


Reviewed By:
                                                      (Aaron Ma )


Approved By:
                                                        ( Jack Ai)




* In the configuration tested, the EUT complied with the standards specified above.

The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to the sample(s)

tested. Without written approval of CQA, this report can’t be reproduced except in full.


                                    Shenzhen Huaxia Testing Technology Co., Ltd
                                                       Report No.: CQASZ20190600466E-02


1   Version
                            Revision History Of Report

          Report No.          Version        Description            Issue Date
     CQASZ20190600466E-02     Rev.01         Initial report         2019-06-27




                              Page:2 of 6


                                                                                 Shenzhen Huaxia Testing Technology Co., Ltd
                                                                                                                    Report No.: CQASZ20190600466E-02




2         Contents
                                                                                                                                                                         Page
1       VERSION .....................................................................................................................................................................2

2       CONTENTS .................................................................................................................................................................3

3       GENERAL INFORMATION .......................................................................................................................................4
    3.1     CLIENT INFORMATION................................................................................................................................................4
    3.2     GENERAL DESCRIPTION OF EUT ................................................................................................................................4
4       RF EXPOSURE EVALUATION ................................................................................................................................5
    4.1 RF EXPOSURE COMPLIANCE REQUIREMENT ..............................................................................................................5
       4.1.1 Limits ..............................................................................................................................................................5
       4.1.2 Test Procedure ..............................................................................................................................................5
    4.2 1.1.3 EUT RF EXPOSURE EVALUATION ....................................................................................................................6




                                                                     Page:3 of 6


                                                   Shenzhen Huaxia Testing Technology Co., Ltd
                                                                         Report No.: CQASZ20190600466E-02



3     General Information
3.1 Client Information
      Applicant:                   ShenZhen Doctors of Intelligence & Technology Co.,Ltd.
      Address of Applicant:        4F,Building 2,Science & Technology Industrial Park,Pingshan Xili,
                                   Nanshan District, Shenzhen, China
      Manufacturer:                ShenZhen Doctors of Intelligence & Technology Co.,Ltd.
      Address of Manufacturer:     4F,Building 2,Science & Technology Industrial Park,Pingshan Xili,
                                   Nanshan District, Shenzhen, China

3.2 General Description of EUT
Product Name:                    Smart Light
Model No.:                       DT-light
Trade Mark:                      DoHome
Hardware version:                V1.4
Software version:                V1.5
Operation Frequency:             IEEE 802.11b/g/n(HT20): 2412MHz to 2462MHz
Channel Numbers:                 IEEE 802.11b/g, IEEE 802.11n HT20: 11 Channels
Channel Separation:              5MHz
Type of Modulation:              IEEE for 802.11b: DSSS(CCK,DQPSK,DBPSK)
                                 IEEE for 802.11g : OFDM(64QAM, 16QAM, QPSK, BPSK)
                                 IEEE for 802.11n(HT20) : OFDM (64QAM, 16QAM,
                                 QPSK,BPSK)
Transfer Rate:                   IEEE for 802.11b:
                                 1Mbps/2Mbps/5.5Mbps/11Mbps
                                 IEEE for 802.11g :
                                 6Mbps/9Mbps/12Mbps/18Mbps/24Mbps/36Mbps/48Mbps/54Mbps
                                 IEEE for 802.11n(HT20) :
                                 6.5Mbps/13Mbps/19.5Mbps/26Mbps/39Mbps/52Mbps/58.5Mbps/65Mbps
Product Type:                       Mobile         Portable        Fix Location
Test Software of EUT:            RF test (manufacturer declare )
Antenna Type:                    PCB antenna
Antenna Gain:                    0dBi
Power Supply:                    AC120V/60Hz




                                             Page:4 of 6


                                                   Shenzhen Huaxia Testing Technology Co., Ltd
                                                                          Report No.: CQASZ20190600466E-02



4       RF Exposure Evaluation

4.1     RF Exposure Compliance Requirement
4.1.1 Limits
        According to FCC Part1.1310: The criteria listed in the following table shall be used to evaluate the
        environment impact of human exposure to radio frequency (RF) radiation as specified in part1.1307(b)




F= Frequency in MHz
Friis Formula
                                                    2
Friis transmission formula: Pd = (Pout*G)/(4* Pi * R )
Where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416

R = distance between observation point and center of the radiator in cm
Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power input to
the antenna, through the calculation, we will know the distance r where the MPE limit is reached.

4.1.2 Test Procedure
        Software provided by client enabled the EUT to transmit and receive data at lowest, middle and
        highest channel individually.




                                            Page:5 of 6


                                                  Shenzhen Huaxia Testing Technology Co., Ltd
                                                                       Report No.: CQASZ20190600466E-02



4.2 1.1.3 EUT RF Exposure Evaluation

1) For WIFI
ANT1:
Antenna Gain: 0dBi
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.0 in linear scale.
Output Power Into Antenna & RF Exposure Evaluation Distance:


Measurement Data
                                               802.11b mode
                                                          Tune up tolerance        Maximum tune-up Power
        Test channel            Average Output Power
                                       (dBm)                      (dBm)              (dBm)       (mW)

     Lowest(2412MHz)                   12.63                      12.5±1             13.5        22.387
     Middle(2437MHz)                   13.15                      13.0±1             14.0        25.119
     Highest(2462MHz)                  13.46                      13.0±1             14.0        25.119
                                               802.11g mode
                                                          Tune up tolerance        Maximum tune-up Power
        Test channel            Average Output Power
                                       (dBm)                      (dBm)              (dBm)       (mW)

     Lowest(2412MHz)                   12.37                   12.0±1.0              13.0        19.953
     Middle(2437MHz)                   12.56                   12.5±1.0              13.5        22.387
     Highest(2462MHz)                   13.1                   13.0±1.0              14.0        25.119
                                            802.11n(HT20)mode
                                                         Tune up tolerance         Maximum tune-up Power
        Test channel            Average Output Power
                                       (dBm)                      (dBm)                          (mW)
                                                                                     (dBm)
     Lowest(2412MHz)                   12.45                   12.0±1.0              13.0        19.953
     Middle(2437MHz)                   12.79                   12.5±1.0              13.5        22.387
     Highest(2462MHz)                  12.54                   12.5±1.0              13.5        22.387

            The worst case:
               Maximum tune-up          Antenna           Power            Limit   Result
                   Power                  Gain           Density
                       (mW)               (dBi)        at R = 20 cm
                                                                  2
                                                        (mW/cm )
                       25.119               0             0.005             1.0     PASS


Note: 1) Refer to report No. CQASZ20190600466E-01 for EUT test Max Conducted average Output Power
      value.
                                2                          2
     2) Pd = (Pout*G)/(4* Pi * R )=(25.119*1.0)/(4*3.1416*20 )=0.005



                                         Page:6 of 6



Document Created: 2019-07-17 11:12:48
Document Modified: 2019-07-17 11:12:48

© 2024 FCC.report