FCC Part 15, Subpart C, Section 15.247 – DTS                                                                                        Page 29 of 33
Alert Labs RN2903                                                                                                           FCC ID: 2AKXF-ALB010


5.5.      RF EXPOSURE REQUIRMENTS [§§ 15.247(i), 1.1310 & 2.1091]

5.5.1.    Limits
§ 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of human
exposure to radio-frequency (RF) radiation as specified in 1.1307(b).

                                        Limits for Maximum Permissible Exposure (MPE)

 Frequency range            Electric field strength            Magnetic field strength              Power density            Averaging time
      (MHz)                          (V/m)                             (A/m)                          (mW/cm2)                 (minutes)
                                      (A) Limits for Occupational/Controlled Exposures
 0.3-3.0                                              614                                 1.63                  *(100)                       6
                                                                                                                       2
 3.0-30                                            1842/f                               4.89/f                *(900/f )                      6
 30-300                                              61.4                               0.163                        1.0                     6
 300-1500                                                                                                           f/300                    6
 1500-100,000                                                                                                          5                     6
                                 (B) Limits for General Population/Uncontrolled Exposure
 0.3-1.34                                             614                                 1.63                  *(100)                     30
                                                                                                                       2
 1.34-30                                            824/f                               2.19/f                *(180/f )                    30
 30-300                                              27.5                               0.073                        0.2                   30
 300-1500                                                                                                       f/1500                     30
  1500-100,000                                                                                                       1.0                   30
f = frequency in MHz
* = Plane-wave equivalent power density

Note 1: Occupational/controlled limits apply in situations in which persons are exposed as a consequence of their
employment provided those persons are fully aware of the potential for exposure and can exercise control over
their exposure. Limits for occupational/controlled exposure also apply in situations when an individual is transient
through a location where occupational/controlled limits apply provided he or she is made aware of the potential
for exposure.

Note 2: General population/uncontrolled exposures apply in situations in which the general public may be
exposed, or in which persons that are exposed as a consequence of their employment may not be fully aware of
the potential for exposure or can not exercise control over their exposure.




ULTRATECH GROUP OF LABS                                                                                       File #: 17SWIF042_FCC15C247DTS
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                              March 17, 2017
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC Part 15, Subpart C, Section 15.247 – DTS                                                                                         Page 30 of 33
Alert Labs RN2903                                                                                                           FCC ID: 2AKXF-ALB010


5.5.2.     Method of Measurements

Calculation Method of Power Density/RF Safety Distance:

       PG         EIRP
S             
      4  r 2
                 4  r 2

Where,               P: power input to the antenna in mW
                     EIRP: Equivalent (effective) isotropic radiated power.
                     S: power density mW/cm2
                     G: numeric gain of antenna relative to isotropic radiator
                     r: distance to centre of radiation in cm



           PG      EIRP
r               
          4  S   4  S


5.5.3.     RF Evaluation
Separation distance specified by Manufacturer is 31cm, the power density and MPE ratio are calculated
for this distance

Configuration 1: Alert Labs RN2903 radio-Standalone

                                         Maximum
               Equivalent Output                                                               Power              MPE
Frequency                                Antenna          EIRP     EIRP      Distance,                                         Margin     RN2903
               Conducted Power                                                                Density, S          Limit              2
  (MHz)                                  Gain (dBi)      (dBm)     (mW)        r (cm)                 2                 2     (mW/cm )     MPE
                     (mW)                                                                     (mW/cm )          (mW/cm )
                                                                                                                                           Ratio
    903                 81                  2.33         21.41     138.36        31             0.0114              0.602       -0.590      0.019



Configuration 2: Co-location

Pursuant to KDB 447498 D01 General RF Exposure Guidance v06, Section 7.2:

Simultaneous transmission MPE test exclusion applies when the sum of the MPE ratios for all simultaneously
transmitting antennas incorporated in a host device is ≤ 1.0, according to calculated/estimated, numerically
modeled, or measured field strengths or power density.




ULTRATECH GROUP OF LABS                                                                                       File #: 17SWIF042_FCC15C247DTS
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                               March 17, 2017
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC Part 15, Subpart C, Section 15.247 – DTS                                                                                    Page 31 of 33
Alert Labs RN2903                                                                                                      FCC ID: 2AKXF-ALB010


As per the Manufacturer the EUT Alert Labs RN2903, can simultaneously transmit with either the cellular radio
(SARA‐U260) or Wifi radio (Espressif Systems WROOM Module)
.
       Configuration 2.1- EUT (RN2903) co-location with Cellular radio module- SARA‐U260 GSM/UMTS Module
                                               FCC ID: XPYSARAU260
                                                IC: 8595A‐SARAU260
                   Equivalent
                                                                            SARA‐U260                                          SARA‐U260
                    Output           Maximum                      Dista-                      FCC     SARA‐U260 RN2903
   Frequency                                          EIRP                    Power                                            and RN2903
                   Conducted          Antenna                      nce                      MPE Limit   MPE      MPE
     (MHz)                                            (mW)                    Density              2                            MPE Ratio
                     Power           Gain (dBi)                   (cm)               2      (mW/cm )    Ratio    Ratio
                                                                             (mW/cm )                                             Sum
                     (mW)

      848.8          1256.03            3.50         2811.90        31         0.233          0.566         0.411      0.019      0.430

     1850.2          629.51             3.10         1285.29        31         0.106          1.000         0.106      0.019      0.125

      846.6          1258.93            3.50         2818.38        31         0.233          0.564         0.414      0.019      0.433

      846.6          251.19             3.50         562.34         31         0.047          0.564         0.083      0.019      0.102

      836.6          251.19             3.50         562.34         31         0.047          0.558         0.083      0.019      0.102

     1852.4          251.19             3.10         512.86         31         0.042          1.000         0.042      0.019      0.061

     1907.6          251.19             3.10         512.86         31         0.042          1.000         0.042      0.019      0.061

     1880.0          251.19             3.10         512.86         31         0.042          1.000         0.042      0.019      0.061



    Configuration 2.2- EUT(RN2903) co-location with Wifi radio module- Espressif Systems WROOM Wi-Fi Module
                                          FCC ID: 2AC7Z-ESPWROOM02
                                             IC: 21098-ESPWROOM02

                    Equivalent                                                  WROOM                                          WROOM Wi-
                                                                                                            WROOM
                     Output           Maximum                      Dista-         Wi-Fi         FCC                  RN2903        Fi
   Frequency                                           EIRP                                                  Wi-Fi
                    Conducted          Antenna                      nce          Power        MPE Limit               MPE      and RN2903
     (MHz)                                             (mW)                                          2       MPE
                      Power           Gain (dBi)                   (cm)         Density       (mW/cm )                Ratio     MPE Ratio
                                                                                        2                    Ratio
                      (mW)                                                     (mW/cm )                                           Sum

     2412.0             225              2.00          356.45        31          0.030           1.000       0.030    0.019      0.049


* The test data of the radio modules represented in the above tables are the worst-case configuration (maximum MPE ratio) derived from the
original radio modules MPE reports. Refer to these reports for details.




Verdict: The user manual specified distance of 31 cm is sufficient to meet the MPE exposure limits ie, Sum of
MPE ratio <1.




ULTRATECH GROUP OF LABS                                                                                       File #: 17SWIF042_FCC15C247DTS
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                           March 17, 2017
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)



Document Created: 2017-04-19 16:37:24
Document Modified: 2017-04-19 16:37:24