RF exposure info

FCC ID: 2AKXB-METERTH1

RF Exposure Info

Download: PDF
FCCID_4093126

                                      RF Exposure evaluation



According to 447498 D01 General RF Exposure Guidance v05

The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances

≤ 50 mm are determined by:

[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√

f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where

  f(GHz) is the RF channel transmit frequency in GHz

  Power and distance are rounded to the nearest mW and mm before calculation

  The result is rounded to one decimal place for comparison



Worse case is as below: [2442 MHz 1.16dBm(1.31 mW)output power]



(1.31 mW /5mm) ·[√2.442(GHz)]= 0.4 <3.0 for 1-g SAR



Then SAR evaluation is not required



Document Created: 2018-12-02 22:43:09
Document Modified: 2018-12-02 22:43:09