test report

FCC ID: 2AKXB-METERTH1

Test Report

Download: PDF
FCCID_4093125

                         Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                       Report No: CCISE181107601

         1        Cover Page
                                          FCC REPORT
                                                           (BLE)

Applicant:                            WoCao Technology (Shenzhen) Co., Ltd.
                                      Baoanzhigu A510, Yintian Rd, Xixiang, Bao'an, Shenzhen,
Address of Applicant:
                                      Guangdong, China
Equipment Under Test (EUT)

    Product Name:                     SwitchBot Thermometer and Hygrometer
                                      SwitchBot MeterTH S1, SwitchBot MeterTH C1, SwitchBot
    Model No.:                        MeterTH J1, SwitchBot MeterTH K1, SwitchBot MeterTH U1,
                                      SwitchBot MeterTH E1
    Trade mark:                       SwitchBot

FCC ID:                               2AKXB-METERTH1

Applicable standards:                 FCC CFR Title 47 Part 15 Subpart C Section 15.247

Date of sample receipt:               19 Nov., 2018

Date of Test:                         19 Nov., to 27 Nov., 2018

Date of report issued:                28 Nov., 2018

Test Result:                          PASS *

*   In the configuration tested, the EUT complied with the standards specified above.




Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate
to other samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer
should ensure that all products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than
that detailed in the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized
alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted
to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested
and such sample(s) are retained for 90 days only.


                                                                                 Report No: CCISE181107601


2      Version
      Version No.                        Date                                    Description
            00                     28 Nov., 2018                                   Original




    Tested by:                                                           Date:          28 Nov., 2018

                                        Test Engineer


    Reviewed by:                                                         Date:          28 Nov., 2018

                                      Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1811076
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                             Page 2 of 37


                                                                                                                       Report No: CCISE181107601

3         Contents
                                                                                                                                                                         Page
1       COVER PAGE ....................................................................................................................................................... 1
2       VERSION ............................................................................................................................................................... 2
3       CONTENTS ........................................................................................................................................................... 3
4       TEST SUMMARY .................................................................................................................................................. 4
5       GENERAL INFORMATION .................................................................................................................................. 5
    5.1         CLIENT INFORMATION ............................................................................................................................................ 5
    5.2         GENERAL DESCRIPTION OF E.U.T........................................................................................................................ 5
    5.3         TEST ENVIRONMENT AND TEST MODE ................................................................................................................... 6
    5.4         DESCRIPTION OF SUPPORT UNITS ........................................................................................................................ 6
    5.5         MEASUREMENT UNCERTAINTY.............................................................................................................................. 6
    5.6         LABORATORY FACILITY.......................................................................................................................................... 6
    5.7         LABORATORY LOCATION ....................................................................................................................................... 6
    5.8         TEST INSTRUMENTS LIST ....................................................................................................................................... 7
6       TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1     ANTENNA REQUIREMENT: ...................................................................................................................................... 8
    6.2     CONDUCTED OUTPUT POWER .............................................................................................................................. 9
    6.3     OCCUPY BANDWIDTH .......................................................................................................................................... 11
    6.4     POWER SPECTRAL DENSITY ............................................................................................................................... 13
    6.5     BAND EDGE ......................................................................................................................................................... 15
       6.5.1 Conducted Emission Method...................................................................................................................... 15
       6.5.2 Radiated Emission Method ......................................................................................................................... 17
    6.6     SPURIOUS EMISSION ........................................................................................................................................... 22
       6.6.1 Conducted Emission Method...................................................................................................................... 22
       6.6.2 Radiated Emission Method ......................................................................................................................... 24
7       TEST SETUP PHOTO ........................................................................................................................................ 29
8       EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 30




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                             Project No.: CCISE1811076
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                      Page 3 of 37


                                                                               Report No: CCISE181107601

 4      Test Summary
                   Test Items                             Section in CFR 47                Result
             Antenna requirement                                 15.203                     Pass
     AC Power Line Conducted Emission                            15.207                     N/A
        Conducted Peak Output Power                           15.247 (b)(3)                 Pass
           6dB Emission Bandwidth
                                                              15.247 (a)(2)                 Pass
           99% Occupied Bandwidth
            Power Spectral Density                             15.247 (e)                   Pass
                   Band Edge                                   15.247 (d)                   Pass
              Spurious Emission                             15.205 & 15.209                 Pass
     Pass: The EUT complies with the essential requirements in the standard.
     N/A: Not Applicable.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1811076
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                           Page 4 of 37


c c I s                                                                         Report No: CCISE181107601

5           General Information
5.1 Client Information
            Applicant:                     WoCao Technology (Shenzhen) Co., Ltd.
            Address:                       Bacanzhigu A510, Yintian Rd, Xixiang, Bac‘an, Shenzhen, Guangdong,
                                           China
            Manufacturer & Factory:        WoCao Technology (Shenzhen) Co., Ltd
            Address:                       Bacanzhigu A510, Yintian Rd, Xixiang, Bac‘an, Shenzhen, Guangdong,
                                           China


5.2 General Description of E.U.T.
            Product Name:                  SwitchBot Thermometer and Hygrometer
            Model No.:                     SwitchBot MeterTH S1, SwitchBot MeterTH C1, SwitchBot MeterTH J1,
                     C                     SwitchBot MeterTH K1, SwitchBot MeterTH U1, SwitchBot MeterTH E1
            Operation Frequency:           2402—2480 MHz
            Channel numbers:               40
            Channel separation:            2 MHz
            Modulation technology:         GFSK
            Data speed :                   1Mbps
            Antenna Type:                  Ceramic Antenna
            Antenna gain:                  1.0 dBi
            Power supply:                  DC 3.0V
            Remark:                        item No.: SwitchBot MeterTH S1, SwitchBot MeterTH C1, SwitchBot
                                           MeterTH J1, SwitchBot MeterTH K1, SwitchBot MeterTH U1, SwitchBot
                                           MeterTH E1 were identical inside, the electrical circuit design, layout,
                                           components used and internal wiring, with only difference being model
                                           name.
            Test Sample Condition:         The test samples were provided in good working order with no visible
                                           defects.


    Operation Frequency each of channel
     Channel    Frequency    Channel    Frequency               Channel    Frequency      Channel     Frequency
        0              2402MHz        10          2422MHz          20       2442MHz         30         2462MHz
        1              2404MHz        11          2424MHz          21       2444MHz         31         2464MHz
        2              2406MHz        12          2426MHz          22       2446MHz         32         2466MHz
        3              2408MHz        13          2428MHz          23       2448MHz         33         2468MHz
        4              2410MHz        14          2430MHz          24       2450MHz         34         2470MHz
        5              2412MHz        15          2432MHz          25       2452MHz         35         2472MHz
        6              2414MHz        16          2434MHz          26       2454MHz         36         2474MHz
        7              2416MHz        17          2436MHz          27       2456MHz         37         2476MHz
        8              2418MHz        18          2438MHz          28       2458MHz         38         2478MHz
        9              2420MHz        19          2440MHz          29       2460MHz         39         2480MHz
    Note:
    In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the
    middle frequency, and the highest frequency of channel were selected to perform the test. Channel No. 0,
    20 & 39 were selected as Lowest, Middle and Highest channel.



Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1811076
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 5 of 37


                                                                              Report No: CCISE181107601

5.3 Test environment and test mode
 Operating Environment:
    Temperature:                     24.0 C
    Humidity:                        54 % RH
    Atmospheric Pressure:            1010 mbar
 Test mode:
    Transmitting mode Keep the EUT in continuous transmitting with modulation (new battery is used during all test)
 The sample was placed 0.8m (below 1GHz)/1.5m (above 1GHz) above the ground plane of 3m chamber.
 Measurements in both horizontal and vertical polarities were performed. During the test, each emission was
 maximized by: having the EUT continuously working, investigated all operating modes, rotated about all 3
 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating interconnecting
 cables, rotating the turntable, varying antenna height from 1m to 4m in both horizontal and vertical
 polarizations. The emissions worst-case are shown in Test Results of the following pages. Duty cycle setting
 during the transmission is 100% with maximum power setting for all modulations.

5.4 Description of Support Units
        The EUT has been tested as an independent unit.

5.5 Measurement Uncertainty
                    Parameters                                            Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                    ±2.22 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                    ±2.76 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                   ±4.28 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                     ±5.72 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                    ±2.88 dB (k=2)

5.6 Laboratory Facility
        The test facility is recognized, certified, or accredited by the following organizations:
         FCC - Registration No.: 727551
        Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by FCC
        (Federal Communications Commission). The Registration No. is 727551.
         IC - Registration No.: 10106A-1
        The 3m Semi-anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
        Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing
        with Registration No.: 10106A-1.
         CNAS - Registration No.: CNAS L6048
        Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
        Requirements for the Competence of Testing and Calibration laboratories for the competence of
        testing. The Registration No. is CNAS L6048.
         A2LA - Registration No.: 4346.01
        This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
        17025:2005 General requirements for the competence of testing and calibration laboratories. The test
        scope can be found as below link: https://portal.a2la.org/scopepdf/4346-01.pdf

5.7 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bao’an District, Shenzhen, Guangdong, China
        Tel: +86-755-23118282, Fax: +86-755-23116366
        Email: info@ccis-cb.com, Website: http://www.ccis-cb.com


Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1811076
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 6 of 37


                                                                                    Report No: CCISE181107601

5.8 Test Instruments list
 Radiated Emission:
                                                                                          Cal. Date       Cal. Due date
    Test Equipment             Manufacturer            Model No.          Serial No.
                                                                                         (mm-dd-yy)        (mm-dd-yy)
        3m SAC                  SAEMC                  9m*6m*6m              966         07-22-2017        07-21-2020
     Loop Antenna            SCHWARZBECK              FMZB1519B             00044        03-16-2018        03-15-2019
   BiConiLog Antenna         SCHWARZBECK               VULB9163              497         03-16-2018        03-15-2019
     Horn Antenna            SCHWARZBECK              BBHA9120D              916         03-16-2018        03-15-2019
     Horn Antenna            SCHWARZBECK              BBHA9120D              1805        06-22-2017        06-21-2020
                                                                                         11-21-2017        11-20-2018
      Horn Antenna           SCHWARZBECK              BBHA 9170          BBHA9170582
                                                                                         11-21-2018        11-20-2019
   EMI Test Software             AUDIX                    E3                        Version: 6.110919b
     Pre-amplifier                 HP                   8447D            2944A09358     03-07-2018         03-06-2019
     Pre-amplifier                 CD                  PAP-1G18             11804       03-07-2018         03-06-2019
   Spectrum analyzer         Rohde & Schwarz            FSP30              101454       03-07-2018         03-06-2019
                                                                                       11-21-2017          11-20-2018
   Spectrum analyzer         Rohde & Schwarz             FSP40             100363
                                                                                       11-21-2018          11-20-2019
    EMI Test Receiver        Rohde & Schwarz           ESRP7                101070       03-07-2018        03-06-2019
         Cable                   ZDECL              Z108-NJ-NJ-81          1608458       03-07-2018        03-06-2019
         Cable                MICRO-COAX              MFR64639             K10742-5      03-07-2018        03-06-2019
         Cable                  SUHNER              SUCOFLEX100           58193/4PE      03-07-2018        03-06-2019
     RF Switch Unit            MWRFTEST                MW200                  N/A            N/A               N/A
     Test Software             MWRFTEST               MTS8200                          Version: 2.0.0.0


 Conducted Emission:
                                                                                          Cal. Date       Cal. Due date
    Test Equipment            Manufacturer             Model No.          Serial No.
                                                                                        (mm-dd-yy)         (mm-dd-yy)
   EMI Test Receiver        Rohde & Schwarz             ESCI               101189        03-07-2018        03-06-2019
     Pulse Limiter          SCHWARZBECK              OSRAM 2306             9731         03-07-2018        03-06-2019
         LISN                   CHASE                 MN2050D               1447         03-19-2018        03-18-2019
         LISN               Rohde & Schwarz           ESH3-Z5            8438621/010     07-21-2018        07-20-2019
        Cable                     HP                   10503A                N/A         03-07-2018        03-06-2019
   EMI Test Software            AUDIX                    E3                          Version: 6.110919b




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                 Project No.: CCISE1811076
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                   Page 7 of 37


                                                                             Report No: CCISE181107601

6      Test results and Measurement Data
6.1 Antenna requirement:
        Standard requirement:           FCC Part 15 C Section 15.203 /247(c)
        15.203 requirement:
        An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
        responsible party shall be used with the device. The use of a permanently attached antenna or of an
        antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
        so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
        electrical connector is prohibited.
        15.247(c) (4) requirement:
        (4) The conducted output power limit specified in paragraph (b) of this section is based on the use of
        antennas with directional gains that do not exceed 6 dBi. Except as shown in paragraph (c) of this
        section, if transmitting antennas of directional gain greater than 6 dBi are used, the conducted output
        power from the intentional radiator shall be reduced below the stated values in paragraphs (b)(1),
        (b)(2), and (b)(3) of this section, as appropriate, by the amount in dB that the directional gain of the
        antenna exceeds 6 dBi.
       E.U.T Antenna:
       The BLE antenna is an Ceramic Antenna which cannot replace by end-user, the best-case gain of the
       antenna is 1.0 dBi.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1811076
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 8 of 37


                                                                                Report No: CCISE181107601

6.2 Conducted Output Power
        Test Requirement:                FCC Part 15 C Section 15.247 (b)(3)
        Test Method:                     ANSI C63.10:2013 and KDB 558074
        Limit:                           30dBm
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data:
                                Maximum Conducted Output Power
          Test CH                                                              Limit(dBm)              Result
                                           (dBm)
           Lowest                                 0.61
           Middle                                 1.16                           30.00                  Pass
          Highest                                 0.98




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1811076
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                Page 9 of 37


                                                                                                                                     Report No: CCISE181107601

Test plot as follows:
                                                 * RBW   1 MHz   Marker 1 [T1 ]                                                              * RBW   1 MHz   Marker 1 [T1 ]
                                                 * VBW   3 MHz               0.61 dBm                                                        * VBW   3 MHz               1.16 dBm
         Ref    16.5 dBm         * Att   20 dB     SWT 2.5 ms         2.402220000 GHz                Ref    16.5 dBm         * Att   20 dB     SWT 2.5 ms         2.442240000 GHz

               Offset   6.5 dB                                                                             Offset   6.5 dB

         10                                                                                          10
                                                                                        A                                                                                           A
                                                   1                                                                                           1
  1 PK   0                                                                                    1 PK   0
  MAXH                                                                                        MAXH
                                                                                        LVL                                                                                         LVL

         -10                                                                                         -10



         -20                                                                                         -20



         -30                                                                                         -30



         -40                                                                            3DB          -40                                                                            3DB




         -50                                                                                         -50



         -60                                                                                         -60



         -70                                                                                         -70



         -80                                                                                         -80

         Center 2.402 GHz                    500 kHz/                      Span 5 MHz                Center 2.442 GHz                    500 kHz/                      Span 5 MHz




  Date: 22.NOV.2018         22:51:48                                                          Date: 22.NOV.2018         22:52:21


                                         Lowest channel                                                                              Middle channel


                                                 * RBW   1 MHz   Marker 1 [T1 ]
                                                 * VBW   3 MHz               0.98 dBm
         Ref    16.5 dBm         * Att   20 dB     SWT 2.5 ms         2.480170000 GHz

               Offset   6.5 dB

         10
                                                                                        A
                                                  1
  1 PK   0
  MAXH
                                                                                        LVL

         -10



         -20



         -30



         -40                                                                            3DB




         -50



         -60



         -70



         -80

         Center 2.48 GHz                     500 kHz/                      Span 5 MHz




  Date: 22.NOV.2018         22:53:03


                                         Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                                             Project No.: CCISE1811076
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                                                                     Page 10 of 37


                                                                                Report No: CCISE181107601

6.3 Occupy Bandwidth
        Test Requirement:                FCC Part 15 C Section 15.247 (a)(2)
        Test Method:                     ANSI C63.10:2013 and KDB 558074
        Limit:                           >500kHz
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data:
         Test CH                6dB Emission Bandwidth (MHz)                Limit(kHz)            Result
          Lowest                              0.732
          Middle                              0.720                           >500                 Pass
         Highest                              0.714
         Test CH                99% Occupy Bandwidth (MHz)                  Limit(kHz)            Result
          Lowest                              1.512
          Middle                              1.110                            N/A                  N/A
         Highest                              1.056




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1811076
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 11 of 37


CCIS                                                                                       Report No: CCISE181107601

Test plot as follows:
                                   6dB EBW                                                       99% OBW
   ® se     ces e
  BA




   orte: 22 mov.zoe 2zisecse                                      orte: 22 nov zore anisscos

                                 Lowest channel                                                Lowest channel




   orte: 22 mov.zore 2zisec0s                                     orte: 2e nov zoie azisecco

                                 Middle channel                                                Middle channel




   onte: 22 mov.zore   ascncso                                    orte: 2e nov zoie nisacse

                                 Highest channel                                               Highest channel


Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                            Project No.: CCISE1811076
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                           Page 12 of 37


                                                                               Report No: CCISE181107601

6.4 Power Spectral Density
        Test Requirement:                FCC Part 15 C Section 15.247 (e)
        Test Method:                     ANSI C63.10:2013 and KDB 558074
        Limit:                           8 dBm
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed


Measurement Data:
           Test CH                 Power Spectral Density (dBm)             Limit(dBm)             Result
            Lowest                                -0.30
            Middle                                0.24                         8.00                 Pass
           Highest                                0.17




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1811076
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                            Page 13 of 37


CCIS                                                                                  Report No: CCISE181107601

Test plots as follow:

 ® ser   ces wan




 oates 22 nov.20r8. rois ue                                     dare: 22.mev .208 23257

                              Lowest channel                                              Middle channel




 oates 22 nov.20r8 roszczs

                              Highest channel




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                       Project No.: CCISE1811076
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                      Page 14 of 37


                                                                               Report No: CCISE181107601

6.5 Band Edge
6.5.1 Conducted Emission Method
        Test Requirement:                FCC Part 15 C Section 15.247 (d)
        Test Method:                     ANSI C63.10:2013 and KDB 558074
        Limit:                           In any 100 kHz bandwidth outside the frequency band in which the
                                         spread spectrum intentional radiator is operating, the radio frequency
                                         power that is produced by the intentional radiator shall be at least 20 dB
                                         below that in the 100 kHz bandwidth within the band that contains the
                                         highest level of the desired power, based on either an RF conducted or a
                                         radiated measurement.
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1811076
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 15 of 37


CCIS                                                                                          Report No: CCISE181107601

Test plots as follow:
                   ®‘                                             «mem 100 knz    merkes i (ri i
                                                                  «vam 300 knz              ~se.83. can
                        mee   is.s gan        mats   20 as         sur 2.3 ne          2.399802000 onz




                        suare 2.39 ons                       128 muz,                   stop 2.402 onz




                   Date: 22.N0V.2018      23:25:59

                                                         Lowest channel



                   ®                                              «mem 100 knz    mexker i(z a
                                                                  «vam 300. knz            ~33.73. cen
                        mee   as.s can        wars   20 as         sur 2.3 ne         2.408e20000 onz




                        suars 2.a7e ons                  2.2 z/                           stop 2.5 on




                   Date: 22.N0V.2018      23:27:59

                                                        Highest channel


Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                              Project No.: CCISE1811076
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                             Page 16 of 37


                                                                               Report No: CCISE181107601


6.5.2     Radiated Emission Method
        Test Requirement:                FCC Part 15 C Section 15.205 and 15.209
        Test Method:                     ANSI C63.10: 2013 and KDB 558074
        Test Frequency Range:            2.3GHz to 2.5GHz
        Test Distance:                   3m
        Receiver setup:                   Frequency         Detector         RBW           VBW          Remark
                                                             Peak            1MHz          3MHz        Peak Value
                                         Above 1GHz
                                                             RMS             1MHz          3MHz      Average Value
        Limit:                                 Frequency             Limit (dBuV/m @3m)              Remark
                                                                             54.00               Average Value
                                              Above 1GHz
                                                                             74.00                 Peak Value
        Test Procedure:                  1. The EUT was placed on the top of a rotating table 1.5 meters above
                                             the ground at a 3 meter camber. The table was rotated 360 degrees
                                             to determine the position of the highest radiation.
                                         2. The EUT was set 3 meters away from the interference-receiving
                                             antenna, which was mounted on the top of a variable-height antenna
                                             tower.
                                         3. The antenna height is varied from one meter to four meters above
                                             the ground to determine the maximum value of the field strength.
                                             Both horizontal and vertical polarizations of the antenna are set to
                                             make the measurement.
                                         4. For each suspected emission, the EUT was arranged to its worst
                                             case and then the antenna was tuned to heights from 1 meter to 4
                                             meters and the rota table was turned from 0 degrees to 360 degrees
                                             to find the maximum reading.
                                         5. The test-receiver system was set to Peak Detect Function and
                                             Specified Bandwidth with Maximum Hold Mode.
                                         6. If the emission level of the EUT in peak mode was 10 dB lower than
                                             the limit specified, then testing could be stopped and the peak values
                                             of the EUT would be reported. Otherwise the emissions that did not
                                             have 10 dB margin would be re-tested one by one using peak, quasi-
                                             peak or average method as specified and then reported in a data
                                             sheet.
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1811076
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 17 of 37


c c I s                                                                                  Report No: CCISE181107601



Product Name:                a\;vgfijh”?:tte'lr'hermometer and        Product Model:             SwitchBot MeterTH S1

Test By:                     Mike                                    Test mode:                 BLE Tx mode

Test Channel:                Lowest channel                          Polarization:              Vertical
Test Voltage:                DC 3V                                   Environment:               Temp: 24°C    Huni: §7%


           "0Level (dBuVim)


           100


            80                                                                                     FCC PART 15 (Q

            60 mtct
                                                                                                       1       (av)


            40



            20



                 2310     2320                           2350                                                   2404
                                                          Frequency (MHz)


                                     ReadAntenna       Cable Preanp                    Linit    Over
                            Freq    Level Factor        Loss Factor         Level       Line   Linit Remark

                             NHz     dbuvy     dB/m        dB       db dBu¥/m dBu¥/m              dB
                 1      2390.000    27.05    27.37      4.69                59.   11   74. 00 —14. 89 Peak
                 2      2390.000    16.22    27.37      4.69                48.28      54.00   —5.72 Average



Remark:
1. Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1811076
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                        Page 18 of 37


c c I s                                                                                Report No: CCISE181107601



Product Name:              a\;vgfijh”?:tte'lr'hermometer and       Product Model:          SwitchBot MeterTH S1

Test By:                   Mike                                   Test mode:              BLE Tx mode

Test Channel:              Lowest channel                         Polarization:           Horizontal
Test Voltage:              DC 3V                                  Environment:            Temp: 24°C        Huni: 57%


            , 1 pLevel (dBuVim)
            100


             °0                                                                                    FCC PART 15 qQ
                                                                                                        1
             60 MMWWWWWWMNWMAV)


             40



             20



              02310      2320                            2350                                                  2404
                                                          Frequency (MHz)

                                    ReadAntenna        Cable Preamp                 Linit      Over
                           Freq    Level Factor         Loss Factor         Level    Line     Limit Remark

                            NHz      dbu¥y — dB/nm            db _db dBu¥/m dBu¥/m                 dB           CC
                  1   2390.000     29.05     27.37      4.69      0.00      61.11   74.00 —12.89 Peak
                  2   2390.000     19.31     27.37      4.69      0.00      51.37   54.00 —2.63 Average


Remark:
1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1811076
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                       Page 19 of 37


c c I s                                                                                Report No: CCISE181107601



Product Name:               f'\;vgfi]hrsstte'lr'hermometer and         Product Model:           SwitchBot MeterTH S1

Test By:                    Mike                                      Test mode:                BLE Tx mode
Test Channel:               Highest channel                           Polarization:            Vertical

Test Voltage:               DC 3V                                     Environment:             Temp: 24°C      Huni: §7%


            4 mLevaI (dBuV/m}

            100


             80                                                                                   FCC PART 15 (Piy
                  h               'hww

             60                                                                                   Tec PRRT Ts (av)

             o

             20


              D2473                                                                                            2500
                                                          Frequency (MHz)

                                    Read&ntenna       Cable Preamp                  Linmit     Over
                          Freq     Level Factor         Loss Factor         Level    Line     Limit Remark

                           NHz      dbu¥y     db/m         db _     dB dBu¥/m dBu¥/m              dB
              1       2483.500     29.39    27.57       4.81      0.00      61.77   74.00 —12.23 Peak
              2        2483.500    16.52    27.57       4.81      0.00      48.90   54.00 —5.10 Average


Remark:
1.   Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1811076
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                        Page 20 of 37


c c I s                                                                                Report No: CCISE181107601



Product Name:               a\;vgfijh”?:tte'lr'hermometer and        Product Model:        SwitchBot MeterTH S1

Test By:                    Mike                                    Test mode:            BLE Tx mode

Test Channel:               Highest channel                         Polarization:         Horizontal

Test Voltage:               DC 3V                                   Environment:          Temp: 24°C         Huni: 57%


           110Leval (dBuVim)

           100


             80 /\                                                                               FCc paRt 15 PR

             so [                   °Ni                                                          FCC PART 15 (AV)


             40



             20


                  2478                                                                                        2500
                                                          Frequency (MHz)

                                     ReadAntenna        Cable Preanp                Linmit     Over
                            Freq    Level Factor         Loss Factor        Level    Line     Linit Remark

                              NHz     dbu¥y — db/m             dB     dB dBu¥/m dBu¥/m            d6
                  1.     2483.500   29.36     27.57      4. 8 1     0.00    61.74   74.00 —12.26 Peak
                  2      2483.500   17.70     27.57      4.8 1      0.00    50.08   54.00 —3.92 Average


Remark:
1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1811076
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                           Page 21 of 37


                                                                               Report No: CCISE181107601

6.6     Spurious Emission
6.6.1     Conducted Emission Method
        Test Requirement:                FCC Part 15 C Section 15.247 (d)
        Test Method:                     ANSI C63.10:2013 and KDB 558074
        Limit:                           In any 100 kHz bandwidth outside the frequency band in which the
                                         spread spectrum intentional radiator is operating, the radio frequency
                                         power that is produced by the intentional radiator shall be at least 20 dB
                                         below that in the 100 kHz bandwidth within the band that contains the
                                         highest level of the desired power, based on either an RF conducted or a
                                         radiated measurement.
        Test setup:




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1811076
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                              Page 22 of 37


CCIS                                                                                          Report No: CCISE181107601

Test plot as follows:
                              Lowest channel                                                  Middle channel
 ® ser   ces wan




 oates 22 nov 208. ao:szise                                     dare: 22. mev .208 rossnist

                              S0OMHz~25GHz                                                    S0OMHz~25GHz


                              Highest channel




 oates 22 nov.gore. rosian

                              30MHz~25GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                           Project No.: CCISE1811076
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                          Page 23 of 37


                                                                                Report No: CCISE181107601

 6.6.2 Radiated Emission Method
        Test Requirement:                FCC Part 15 C Section 15.205 and 15.209
        Test Method:                     ANSI C63.10:2013
        Test Frequency Range:            9kHz to 25GHz
        Test Distance:                   3m
        Receiver setup:                    Frequency       Detector         RBW        VBW             Remark
                                          30MHz-1GHz      Quasi-peak      120KHz     300KHz       Quasi-peak Value
                                                            Peak           1MHz        3MHz           Peak Value
                                          Above 1GHz
                                                            RMS            1MHz        3MHz         Average Value
        Limit:                                  Frequency           Limit (dBuV/m @3m)              Remark
                                              30MHz-88MHz                    40.0               Quasi-peak Value
                                             88MHz-216MHz                    43.5               Quasi-peak Value
                                            216MHz-960MHz                    46.0               Quasi-peak Value
                                              960MHz-1GHz                    54.0               Quasi-peak Value
                                                                             54.0                Average Value
                                               Above 1GHz
                                                                             74.0                 Peak Value
        Test Procedure:                  1.   The EUT was placed on the top of a rotating table 0.8m(below
                                              1GHz)/1.5m(above 1GHz) above the ground at a 3 meter camber.
                                              The table was rotated 360 degrees to determine the position of the
                                              highest radiation.
                                         2.   The EUT was set 3 meters away from the interference-receiving
                                              antenna, which was mounted on the top of a variable-height antenna
                                              tower.
                                         3.   The antenna height is varied from one meter to four meters above
                                              the ground to determine the maximum value of the field strength.
                                              Both horizontal and vertical polarizations of the antenna are set to
                                              make the measurement.
                                         4.   For each suspected emission, the EUT was arranged to its worst
                                              case and then the antenna was tuned to heights from 1 meter to 4
                                              meters and the rota table was turned from 0 degrees to 360 degrees
                                              to find the maximum reading.
                                         5.   The test-receiver system was set to Peak Detect Function and
                                              Specified Bandwidth with Maximum Hold Mode.
                                         6.   If the emission level of the EUT in peak mode was 10 dB lower than
                                              the limit specified, then testing could be stopped and the peak values
                                              of the EUT would be reported. Otherwise the emissions that did not
                                              have 10 dB margin would be re-tested one by one using peak, quasi-
                                              peak or average method as specified and then reported in a data
                                              sheet.
        Test setup:                      Below 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                               Project No.: CCISE1811076
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                               Page 24 of 37


                                                                            Report No: CCISE181107601

                                         Above 1GHz




        Test Instruments:                Refer to section 5.8 for details
        Test mode:                       Refer to section 5.3 for details
        Test results:                    Passed
        Remark:                          1. Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and
                                            found the Y-axis is the worst case.
                                         2. 9 kHz to 30MHz is too low, so only shows the data of above 30MHz
                                            in this report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1811076
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                         Page 25 of 37


CCIS                                                                                       Report No: CCISE181107601

Measurement Data (worst case):
Below 1GHz:

                                    SwitchBot Thermometer and
Product Name:                                                              Product Model:           SwitchBot MeterTH S1
                                    Hygrometer

Test By:                            Mike                                   Test mode:               BLE Tx mode
Test Frequency:                     30 MHz ~ 1 GHz                         Polarization:            Vertical

Test Voltage:                       DC 3V                                  Environment:             Temp: 24°C         Huni: 57%


           80Level (dBuVim)


           70

           60
                                                                                                         FCC PART 15.247




                    30              50                100                200                       500                 1000
                                                               Frequency (MHz)


                                            ReadAntenna     Cable Preanp                Limit      Over
                                  Freq     Level Factor       Loss Factor      Level     Line     Linit Remark

                                   MHz      dBu¥    dB/nm      dB         dB dBu¥/m dBu¥/m
                                31 .955    36.64   11.05     0.85   29.   97   18.57    40,.00   —21.43     QP
             o on /A Ca ho —




                                99 .180    40.42   11.57     1.95   29.   §3   24.41    43.50    —19.09     QP
                               122 .834    36.59    9.76     2.20   29.   37   19.18    43.50    —24. 32    QP
                               129 .923    38.46    8.71     2.28   29.   33   20.12    43.50    —23. 38    QP
                               189 739     33.20   i1.16     2.79   28.   90   18.25    43.50    —25. 25    QP
                               396 .242    29.72   15.44     3.08   28.   T6   19.48    46.00    —26. 52    QP


Remark:
1.   Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                               Project No.: CCISE1811076
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                              Page 26 of 37


CCIS                                                                                        Report No: CCISE181107601



                                    SwitchBot Thermometer and
Product Name:                                                            Product Model                 SwitchBot MeterTH S1
                                    Hygrometer

Test By:                            Mike                                 Test mode:                    BLE Tx mode
Test Frequency:                     30 MHz ~ 1 GHz                       Polarization:                 Horizontal

Test Voltage:                       DC 3V                                Environment:                  Temp: 24°C            Huni: 57%


                    Level (dBuVim)
            80

            70

            60
                                                                                                           FCC PART 15.247




                    30              50               100               200                           500                1000
                                                              Frequency (MHz)



                                            ReadAntenna     Cable Preamp                 Limit         Over
                                Freq       Level Factor       Loss Factor       Level     L ine       Linit Remark

                                    MHz     dBu¥     dB/m      dB        db dBu¥/m dBu¥/m                  dB

                              30.   531    34.22   10.73     0.178   29.98      15.75    40 .   00   —24. 25    QP
              o on & co ho




                             109.   029    29.61   12.24     2.04    29.46      14.43    43 .   50   —29.07     QP
                             392.   095    29.03   1§.37     3.08    28.15      18.173   46 .   00   —21.21     QP
                             513.   633    28.94   1T.64     3.69    28.99      21.28    46 .   00   —24. 12    QP
                             758.   041    29.26   21.00     4.36    28.43      26.19    46 .   00   —19.81     QP
                             872.   183    28.90   21.75     3.97    217.95     26.67    46 &   00   —19. 33    QP


Remark:
1.   Final Level= Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                 Project No.: CCISE1811076
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                                    Page 27 of 37


                                                                                    Report No: CCISE181107601

Above 1GHz
                                             Test channel: Lowest channel
                                                 Detector: Peak Value
                  Read       Antenna        Cable       Preamp
 Frequency                                                            Level       Limit Line      Over
                  Level       Factor        Loss         Factor                                              Polarization
   (MHz)                                                            (dBuV/m)      (dBuV/m)      Limit (dB)
                 (dBuV)       (dB/m)         (dB)         (dB)
  4804.00         60.97        31.60        6.80       41.81       57.56            74.00         -16.44      Vertical
  4804.00         66.61        31.60        6.80       41.81       63.20            74.00         -10.80     Horizontal
                                                Detector: Average Value
                  Read       Antenna        Cable     Preamp
 Frequency                                                         Level          Limit Line      Over
                  Level       Factor        Loss       Factor                                                Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)      Limit (dB)
                 (dBuV)       (dB/m)         (dB)       (dB)
  4804.00         47.88        31.60        6.80       41.81       44.47            54.00          -9.53      Vertical
  4804.00         51.20        31.60        6.80       41.81       47.79            54.00          -6.21     Horizontal



                                              Test channel: Middle channel
                                                  Detector: Peak Value
                  Read       Antenna        Cable     Preamp
 Frequency                                                          Level         Limit Line      Over
                  Level       Factor        Loss       Factor                                                Polarization
   (MHz)                                                          (dBuV/m)        (dBuV/m)      Limit (dB)
                 (dBuV)       (dB/m)         (dB)       (dB)
  4884.00         60.17        31.72        6.86       41.84        56.91           74.00         -17.09      Vertical
  4884.00         64.82        31.72        6.86       41.84        61.56           74.00         -12.44     Horizontal
                                                Detector: Average Value
                  Read       Antenna        Cable     Preamp
 Frequency                                                          Level         Limit Line      Over
                  Level       Factor        Loss       Factor                                                Polarization
   (MHz)                                                          (dBuV/m)        (dBuV/m)      Limit (dB)
                 (dBuV)       (dB/m)         (dB)       (dB)
  4884.00         48.30        31.72        6.86       41.84        45.04           54.00          -8.96      Vertical
  4884.00         48.20        31.72        6.86       41.84        44.94           54.00          -9.06     Horizontal



                                             Test channel: Highest channel
                                                  Detector: Peak Value
                  Read       Antenna        Cable     Preamp
 Frequency                                                         Level          Limit Line      Over
                  Level       Factor        Loss       Factor                                                Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)      Limit (dB)
                 (dBuV)       (dB/m)         (dB)       (dB)
  4960.00         58.87        31.84        6.91       41.87       55.75            74.00         -18.25      Vertical
  4960.00         58.60        31.84        6.91       41.87       55.48            74.00         -18.52     Horizontal
                                                Detector: Average Value
                  Read       Antenna        Cable     Preamp
 Frequency                                                         Level          Limit Line      Over
                  Level       Factor        Loss       Factor                                                Polarization
   (MHz)                                                         (dBuV/m)         (dBuV/m)      Limit (dB)
                 (dBuV)       (dB/m)         (dB)       (dB)
  4960.00         44.78        31.84        6.91       41.87       41.66            54.00         -12.34      Vertical
  4960.00         44.76        31.84        6.91       41.87       41.64            54.00         -12.36     Horizontal
 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor.
 2. The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE1811076
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 23118282 Fax: +86 (0) 755 23116366                                                    Page 28 of 37



Document Created: 2018-12-02 22:38:44
Document Modified: 2018-12-02 22:38:44

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC