            ORLAB!                                                                                    REPORT No. : SZ16120062E02
            _



                                FCC TEST REPORT


                          APPLICANT                                      Beijing LLVision Technology Co., Itd

                          PRODUCT NAME                                   Smart Glass Host

                          MODEL NAME                                     GLXSS Pro

                          TRADE NAME                                     GLXSS

                          BRAND NAME                                     GLXSS

                          STANDARD(S)                                    47 CFR Part 15 Subpart B

                          TEST DATE                                      2017—01—20 to 2017—02—06

                          ISSUE DATE                                     2017—02—07




             SHENZHEN MORLAB C                                                                       @ECHNOLOGY Co., Ltd.




NOTE: This document is issued by MORLAB, the test report shall not be—reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.


                                          FL1—3, Building A, FeiYang Science Park, No.8 LongChang Road,            Tel: 86—755—36698555    Fax: 86—755—36698525
MORLAB               GROU P               Blocké7, BacAn ‘Distric(, ShenZhen , G,uar;gDong Province, P. R. China   Hittp:/Awww.morlab.cn   E—mail: service@morlab.cn


                                                                                                        REPORT No.:SZ16120062E02



                                                               DIRECTORY

 1. TECHNICAL INFORMATION∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙5


 1.1. APPLICANT INFORMATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙5
 1.2. EQUIPMENT UNDER TEST (EUT) DESCRIPTION∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙5


 2. TEST RESULTS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙6


 2.1. APPLIED REFERENCE DOCUMENTS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙6


 3. TEST CONDITIONS SETTING ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7


 3.1. TEST MODE ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙7
 3.2. TEST SETUP AND EQUIPMENTS LIST∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙8
 3.2.1. CONDUCTED EMISSION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙8
 3.2.2. RADIATED EMISSION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙9


 4. 47 CFR PART 15B REQUIREMENTS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 11


 4.1. CONDUCTED EMISSION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙11
 4.1.1. REQUIREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 11
 4.1.2. TEST DESCRIPTION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 11
 4.1.3. TEST RESULT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 11
 4.2. RADIATED EMISSION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙14
 4.2.1. REQUIREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 14
 4.2.2. TEST DESCRIPTION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 14
 4.2.3. FREQUENCY RANGE OF MEASUREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 15
 4.2.4. TEST RESULT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 15


 ANNEX A TEST SETUP PHOTOS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙18


 1. MAINS TERMINAL DISTURBANCE VOLTAGE MEASUREMENT ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙18


 2. CONDUCTED EMISSION MAIN’S PORT SIDE VIEW ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 18




                                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
M ORLAB GROU P                              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                                 Page 2 0f 21


                                                                                                      REPORT No.:SZ16120062E02


 3. RADIATED EMISSION (30MHZ-1GHZ) ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 19


 4. RADIATED EMISSION (ABOVE 1GHZ) ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 19


 ANNEX B TEST UNCERTAINTY ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙20


 ANNEX C TESTING LABORATORY INFORMATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙ 21


 1.         IDENTIFICATION OF THE RESPONSIBLE TESTING LABORATORY ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙21
 2.         IDENTIFICATION OF THE RESPONSIBLE TESTING LOCATION ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙21
 3.         ACCREDITATION CERTIFICATE ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙21
 4.         TEST ENVIRONMENT CONDITIONS ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙21




                                                               Change History
  Issue                 Date                                                       Reason for change
      1.0          2017-02-07                                                            First edition




                                          FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
M ORLAB GROU P                            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                               Page 3 0f 21


     ORLAB:                                                                              REPORT No. : SZ16120062E02
      wW
                                  Test Report Declaration

   Applicant                    Beijing LLVision Technology Co., Itd
                                Room903, Unit A, The Spaces International Center, No.8
   ApplicantAddress             Dongdagiao Road, Chaoyang District, Beijing, P.R. China
   Manufacturer                 Huizhou BYD Electronic Company Limited
   Mianutactdfer Addrets        filua;fi :l:“(j;iuii,\:;;(I;):ga Bay Economic Development Zone


   Product Name                 Smart Glass Host

   Model Name                   GLXSS Pro

   Brand Name                   GLXSS

   HW Version                   B2

   SW Version                   G20A_V0O3.1201

   Test Standards               47 CFR Part 15 Subpart B

* Test Result                   PasS



                 Tested by              :             M/V\ 21/\?)"/("1\/\/?/*’\
                                                       Wu Zhongwen (Test Engineer)


                 Reviewed by            _:                  Xiao            Xiong
                                                           Xiao Xiong (EM& Manager)


                 Approved by            _:                    M 3’&&\/
                                                                      U
                                                      Andy Yeh (Technology Manager)




M o RLAB       G Ro U P      FL1—3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86—755—36698555    Fax: 86—755—36698525
                             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Hittp:/Awww.morlab.cn   E—mail: service@morlab.cn

                                                                                                                                   Page 4 Of 21


                                                                                          REPORT No.:SZ16120062E02



 1. Technical Information
 Note: Provided by applicant

 1.1. Applicant Information
      Company:      Beijing LLVision Technology Co., ltd
      Address:      Room903, Unit A, The Spaces International Center, No.8 Dongdaqiao Road,
                    Chaoyang District, Beijing, P.R. China

 1.2. Equipment under Test (EUT) Description
                  EUT Type: Smart Glass Host
                  Serial No: (N/A, marked #1 by test site)
         Hardware Version: B2
          Software Version: G20A_V03.1201


             Power supply: Battery
                           Brand Name:                         GLXSS
                               Model No.:                      B18650-2
                               Serial No.:                     (N/A, marked #1 by test site)
                               Capacity:                       5800mAh
                               Normal Voltage:                 3.7V
                               Charge Limit:                   4.35V
       Ancillary Equipment: AC Adapter (Charger for Battery)
                               Brand Name:                     GLXSS
                               Model No.:                      TUUS050200-L00
                               Serial No.:                     (N/A, marked #1 by test site)
                               Rated Input:                         100-240V, 50/60Hz, 500mA
                               Rated Output:                   5.0V 2A

 NOTE:

 1.    The EUT is a Smart Glass Host which supports 5.8G SRD, ISM 2.4GHz Bluetooth band, WIFI

       (802.11a/b/g/n) band and GPS.

 2.    The EUT is equipped with a Type-C port which can be connected to ancillary equipments.

 3.    For a more detailed description, please refer to specification or user’s manual supplied by the

       applicant and/or manufacturer.



                              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
M ORLAB GROU P                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 5 0f 21


                                                                                         REPORT No.:SZ16120062E02



 2. Test Results
 2.1. Applied Reference Documents
 The objective of the report is to perform testing according to 47 CFR Part 15 Subpart B:

         No.    Identity                                           Document Title
         1      47 CFR Part 15                                     Radio Frequency Devices

 Test detailed items/section required by FCC rules and results are as below:

         No.   Section     Description                             Test Date                                        Result
         1     15.107      Conducted Emission                      2017.01.23                                       PASS
         2     15.109      Radiated Emission                       2017.01.23                                       PASS

 NOTE: The tests were performed according to the method of measurements prescribed in ANSI
 C63.4-2014.




                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
M ORLAB GROU P               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page 6 0f 21


                                                                                      REPORT No.:SZ16120062E02



 3.     Test Conditions Setting
 3.1. Test Mode
 1       The first test mode
         The EUT configuration of the emission tests is EUT + Battery + PC.
         During the measurement, the EUT was connected to a PC via the Type-C port and the
         EUT was charged by the PC. During the measurement, the data is transmitting between
         the PC and the EUT.
 2       The second test mode
         The EUT configuration of the emission tests is EUT + Battery + Adapter.
         During the measurement, the EUT was connected with the Adapter via the Type-C port
         and kept charging by the Adapter, meanwhile, it was kept rated output and working
         normally.
 3       The third test mode
         The EUT configuration of the emission tests is EUT + Battery + Smart glasses.
         Before the test, the EUT was charged fully. During the measurement, the EUT was
         connected with the Smart glasses, meanwhile, it was kept rated output and working
         normally.
 Note: All the test modes were performed, only the worst case (the first) was recorded in the
 report.




                          FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
M ORLAB GROU P            Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                               Page 7 0f 21


                                                                                        REPORT No.:SZ16120062E02



 3.2. Test Setup and Equipments List

 3.2.1. Conducted Emission
 A. Test Setup:




 The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor,
 and keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power
 mains through a LISN which provides 50Ω/50µH of coupling impedance for the measuring
 instrument. A Pulse Limiter is used to protect the measuring instrument. The factors of the whole
 test system are calibrated to correct the reading.
 The power strip or extension cord has been investigated to make sure that the LISN integrity in
 maintained with respect to the impedance characteristics as prescribed in ANSI C63.4-2014       at
 Clause 4.3.

 B. Equipments List:

     Description       Manufacturer                    Model                    Serial No.           Cal. Date            Due. Date
       Receiver            Narda                   PMM 9010                   595WX11007            2016.06.02           2017.06.01
         LISN           Schwarzbeck                NSLK 8127                      812744            2016.06.02           2017.06.01
     Pulse Limiter
                           VTSD                       9561D                         9537            2016.07.05           2017.07.04
        (20dB)




                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
M ORLAB GROU P              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                 Page 8 0f 21


                                                                                        REPORT No.:SZ16120062E02



 3.2.2. Radiated Emission

 A. Test Setup:
     1.   For radiated emissions from 30MHz to1GHz




     2.   For radiated emissions above 1GHz




 The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on of


                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
M ORLAB GROU P              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                 Page 9 0f 21


                                                                                         REPORT No.:SZ16120062E02


 the site (factors) is calculated to correct the reading. The EUT is placed on a 0.8m high insulating
 Turn Table, and keeps 3m away from the Test Antenna, which is mounted on a variable-height
 antenna master tower.

 For the test Antenna:

 In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn Test
 Antenna (above 1GHz) are used. Test Antenna is 3m away from the EUT. Test Antenna height is
 varied from 1m to 4m above the ground to determine the maximum value of the field strength. The
 emission levels at both horizontal and vertical polarizations should be tested.

 B. Equipments List:

     Description         Manufacturer                  Model                    Serial No.             Cal. Date            Due. Date
  MXE EMI Receiver          Agilent                   N9038A                  MY54130016              2016.06.03           2017.06.02
    Semi-Anechoic
                          Changning                9m*6m*6m                          N/A              2016.03.25           2017.03.24
       Chamber
 Test Antenna - Bi-Log   Schwarzbeck               VULB 9163                     9163-274             2016.12.09           2017.12.08
  Test Antenna - Horn    Schwarzbeck              BBHA9120C                     9120C-384             2016.07.05           2017.07.04
     18-26.5GHz
                             MA03                    TS-PR18               Rohde&Schwarz              2016.03.02           2017.03.01
     pre-Amplifier
     26.5-40GHz                                  NSP4000-SP
                            C00990                                                  Miteq             2016.03.02           2017.03.01
     pre-Amplifier                                         2




                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
M ORLAB GROU P               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                 Page 10 0f 21


                                                                                          REPORT No.:SZ16120062E02




 4.       47 CFR Part 15B Requirements
 4.1. Conducted Emission

 4.1.1. Requirement

 According to FCC section 15.107, the radio frequency voltage that is conducted back onto the AC
 power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the
 following table, as measured using a 50µH/50Ω line impedance stabilization network (LISN).

      Frequency range                                            Conducted Limit (dBµV)
           (MHz)                              Quasi-peak                                                  Average
         0.15 - 0.50                              66 to 56                                                 56 to 46
          0.50 - 5                                    56                                                        46
           5 - 30                                     60                                                       50
 NOTE:
 a) The limit subjects to the Class B digital device.
 b) The lower limit shall apply at the band edges.
 c)   The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.


 4.1.2. Test Description

 See section 3.2.1 of this report.


 4.1.3. Test Result

 The maximum conducted interference is searched using Peak (PK), Quasi-peak (QP) and
 Average (AV) detectors; the emission levels more than the AV and QP limits, and that have narrow
 margins from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L
 phase and N phase lines of the power mains connected to the EUT are performed. All test modes
 are considered, refer to recorded points and plots below.

 A. Test Plot and Suspicious Points:




                              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
M ORLAB GROU P                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page 11 0f 21


                                                                                       REPORT No.:SZ16120062E02




                                               (Plot A: L Phase)



         Fre.    Emission Level (dBµV)                           Limit (dBµV)
   No.                                                                                           Power-line              Verdict
         (MHz)   Quai-peak           Average            Quai-peak              Average
    1    0.15      51.68               30.48                66.00                56.00                                   PASS
    2    0.265     44.93               32.08                62.71                52.71                                   PASS
    3    0.58      42.94               30.93                56.00                46.00                                   PASS
                                                                                                    Line
    4    1.66      43.96               28.92                56.00                46.00                                   PASS
    5    2.68      40.81               28.55                56.00                46.00                                   PASS
    6    4.525     38.81               27.00                56.00                46.00                                   PASS




                           FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,          Tel: 86-755-36698555   Fax: 86-755-36698525
M ORLAB GROU P             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China    Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                Page 12 0f 21


                                                                                        REPORT No.:SZ16120062E02




                                               (Plot B: N Phase)



          Fre.    Emission Level (dBµV)                         Limit (dBµV)
    No.                                                                                           Power-line               Verdict
          (MHz)   Quai-peak          Average           Quai-peak              Average
     1    0.165     52.07              32.79               65.57                55.57                                      PASS
     2    0.22      45.96              32.53               64.00                54.00                                      PASS
     3    0.60      42.33              31.02               56.00                46.00                                      PASS
                                                                                                   Neutral
     4    1.225     43.01              35.24               56.00                46.00                                      PASS
     5    1.65      44.37              38.16               56.00                46.00                                      PASS
     6    3.02      41.99              33.97               56.00                46.00                                      PASS

 Result: Pass




                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,           Tel: 86-755-36698555    Fax: 86-755-36698525
M ORLAB GROU P              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China     Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                   Page 13 0f 21


                                                                                          REPORT No.:SZ16120062E02



 4.2. Radiated Emission


 4.2.1. Requirement

 According to FCC section 15.109 (a), the field strength of radiated emissions from unintentional
 radiators at a distance of 3 meters shall not exceed the following values:

               Frequency         Field Strength Limitation at 3m Measurement Dist
              range (MHz)                      (µV/m)                                         (dBµV/m)
               30.0 - 88.0                        100                                         20log 100
              88.0 - 216.0                        150                                         20log 150
              216.0 - 960.0                       200                                         20log 200
              Above 960.0                         500                                         20log 500

 As shown in FCC section 15.35 (b), for frequencies above 1000MHz, the field strength limits are
 based on average detector. When average radiated emission measurements are specified in this
 part, including emission measurements below 1000MHz, there also is a limit on the radio
 frequency emissions, as measured using instrumentation with a peak detector function,
 corresponding to 20dB above the maximum permitted average limit for the frequency being
 investigated unless a different peak emission limit is otherwise specified in the rules.

 Note:

 1)   The tighter limit shall apply at the boundary between two frequency range.
 2)   Limitation expressed in dBµV/m is calculated by 20log Emission Level (µV/m).
 3)   If measurement is made at 3m distance, then F.S Limitation at 3m distance is adjusted by
      using the formula of Ld1 = Ld2 * (d2/d1)2.
      Example:
      F.S Limit at 30m distance is 30µV/m, then F.S Limitation at 3m distance is adjusted as
      Ld1 = L1 = 30µV/m * (10)2 = 100 * 30µV/m


 4.2.2. Test Description

 See section 3.2.2 of this report.




                              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
M ORLAB GROU P                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page 14 0f 21


                                                                                         REPORT No.:SZ16120062E02



 4.2.3. Frequency range of measurement

 According to 15.33(b) (1), the frequency range of radiated measurement for the EUT is listed in the
 following table:




 4.2.4. Test Result

 The maximum radiated emission is searched using PK, QP and AV detectors; the emission levels
 more than the limits, and that have narrow margins from the limits will be re-measured with AV and
 QP detectors. Both the vertical and the horizontal polarizations of the Test Antenna are considered
 to perform the tests. All test modes are considered, refer to recorded points and plots below.

 The amplitude of emissions (6GHz-30GHz) which are attenuated more than 20 dB below the
 permissible value need not be reported.

 Note: All radiated emission tests were performed in X, Y, Z axis direction, and only the worst axis
 test condition was recorded in this test report.

 A. Test Plots and Suspicious Points:




                             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
M ORLAB GROU P               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                 Page 15 0f 21


                                                                                        REPORT No.:SZ16120062E02




                     (Plot A: 30MHz – 6GHz, Test Antenna Vertical)


  No.     Fre.       Pk            QP                AV           Limit-PK          Limit-QP      Limit-AV          ANT            Verdict
          MHz      dBµV/m      dBµV/m            dBµV/m           dBµV/m             dBµV/m        dBµV/m
   1     30.970     N.A.         37.69             N.A.              N.A.              40.00         N.A.                V         PASS
   2    172.590     N.A.         24.13             N.A.              N.A.              43.50         N.A.                V         PASS
   3    470.380     N.A.         25.49             N.A.              N.A.              46.00         N.A.                V         PASS
   4    1452.267   40.31          N.A.            34.33             74.00               N.A.        54.00                V         PASS
   5    2838.080   45.28          N.A.            39.07             74.00               N.A.        54.00                V         PASS
   6    5632.320   47.71          N.A.            41.24             74.00               N.A.        54.00                V         PASS




                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555       Fax: 86-755-36698525
M ORLAB GROU P              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn       E-mail: service@morlab.cn

                                                                                                                                    Page 16 0f 21


                                                                                        REPORT No.:SZ16120062E02




                    (Plot B: 30MHz – 6GHz, Test Antenna Horizontal)


  No.     Fre.       Pk             QP                AV           Limit-PK          Limit-QP      Limit-AV          ANT        Verdict
          MHz      dBµV/m       dBµV/m            dBµV/m           dBµV/m             dBµV/m        dBµV/m
   1     49.400     N.A.          19.85             N.A.              N.A.              40.00         N.A.               H      PASS
   2    169.680     N.A.          23.48             N.A.              N.A.              43.50         N.A.               H      PASS
   3    283.170     N.A.          29.14             N.A.              N.A.              46.00         N.A.               H      PASS
   4    1280.000   40.12           N.A.            34.08             74.00              N.A.         54.00               H      PASS
   5    2784.320   45.80           N.A.            39.64             74.00              N.A.         54.00               H      PASS
   6    4539.200   46.56           N.A.            40.15             74.00              N.A.         54.00               H      PASS

 Result: Pass




                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
M ORLAB GROU P              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                Page 17 0f 21


                                                                                   REPORT No.:SZ16120062E02



 Annex A      Test Setup photos
   1. Mains Terminal Disturbance Voltage Measurement




   2. Conducted emission main’s port side view




                       FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
M ORLAB GROU P         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                           Page 18 0f 21


                                                                                  REPORT No.:SZ16120062E02


   3. Radiated emission (30MHz-1GHz)




   4. Radiated emission (Above 1GHz)




                      FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
M ORLAB GROU P        Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                          Page 19 0f 21


                                                                                       REPORT No.:SZ16120062E02



 Annex B         Test Uncertainty
 The uncertainty is calculated using the methods suggested in the "Guide to the Expression of
 Uncertainty in Measurement" (GUM) published by ISO.
 Uncertainty of Conducted Emission:            ±1.8dB
 Uncertainty of Radiated Emission:             ±3.1dB




                           FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
M ORLAB GROU P             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                               Page 20 0f 21


                                                                                        REPORT No.:SZ16120062E02



 Annex C          Testing Laboratory Information

 1. Identification of the Responsible Testing Laboratory
  Company Name:                             Shenzhen Morlab Communications Technology Co., Ltd.
  Department:                               Morlab Laboratory
  Address:                                  FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                            Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                            Province, P. R. China
  Responsible Test Lab Manager:             Mr. Su Feng
  Telephone:                                +86 755 36698555
  Facsimile:                                +86 755 36698525


 2. Identification of the Responsible Testing Location

  Name:                                     Shenzhen Morlab Communications Technology Co., Ltd.
                                            Morlab Laboratory
  Address:                                  FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                            Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                            Province, P. R. China


 3. Accreditation Certificate
  Accredited Testing Laboratory:            The FCC registration number is 695796.
                                            (Shenzhen Morlab Communications Technology Co., Ltd.)


 4. Test Environment Conditions
 During the measurement, the environmental conditions were within the listed ranges:

  Temperature (°C):                              15 - 35
  Relative Humidity (%):                         30 - 60
  Atmospheric Pressure (kPa):                    86 - 106



                                     ***** END OF REPORT *****



                            FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,         Tel: 86-755-36698555   Fax: 86-755-36698525
M ORLAB GROU P              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                Page 21 0f 21



Document Created: 2017-12-25 12:31:34
Document Modified: 2017-12-25 12:31:34

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC