RF Exposure

FCC ID: 2AKJA-S1500W5

RF Exposure Info

Download: PDF
FCCID_3435719

MS Magnet Solutions Ltd.                                                                         FCC ID: 2AKJA-S1500W5


5     FCC §15.247(i) – RF Exposure
5.1    Applicable Standards
According to FCC §15.247(i) and §1.1307(b)(1), systems operating under the provisions of this section shall be
operated in a manner that ensures that the public is not exposed to radio frequency energy level in excess of the
Commission’s guidelines.

                                 Limits for General Population/Uncontrolled Exposure

          Frequency            Electric Field        Magnetic Field
                                                                              Power Density            Averaging Time
            Range                Strength              Strength
                                                                                (mW/cm2)                 (minutes)
            (MHz)                  (V/m)                (A/m)
                                   Limits for General Population/Uncontrolled Exposure
           0.3-1.34                 614                    1.63                   * (100)                    30
                                                                                          2
            1.34-30                824/f                  2.19/f                 * (180/f )                  30
            30-300                  27.5                   0.073                    0.2                      30
           300-1500                   /                      /                    f/1500                     30
         1500-100,000                 /                      /                      1.0                      30

        f = frequency in MHz
        * = Plane-wave equivalent power density
Before equipment certification is granted, the procedure of IC RSS-102 must be followed concerning the
exposure of humans to RF field

5.2    MPE Prediction
Predication of MPE limit at a given distance, Equation from OET Bulletin 65, Edition 97-01

                                                      S = PG/4R²
Where: S = power density
       P = power input to antenna
       G = power gain of the antenna in the direction of interest relative to an isotropic radiator
       R = distance to the center of radiation of the antenna

5.3    MPE Results

                       Maximum peak output power at antenna input terminal (dBm):              18.59
                       Maximum peak output power at antenna input terminal (mW):               72.277
                                                              Prediction distance (cm):        20
                                                         Prediction frequency (MHz):           2412
                                              Maximum Antenna Gain, typical (dBi):             5
                                                  Maximum Antenna Gain (numeric):              3.162
                         Power density of prediction frequency at 20.0 cm (mW/cm2):            0.0455
           FCC MPE limit for uncontrolled exposure at prediction frequency (mW/cm2):           1.0

The device is compliant with the requirement MPE limit for uncontrolled exposure. The maximum power
density at the distance of 20 cm is 0.0455 mW/cm2. Limit is 1.0 mW/cm2, the percentage is 0.0455/1=4.55%.
The total percentage is 76.7% (WWAN) + 4.55% (WLAN) = 81.25%.


Report Number: R16121419-247 DTS (Wi-Fi)                     Page 14 of 55                            FCC Part 15C Test Report



Document Created: 2017-10-22 06:28:29
Document Modified: 2017-10-22 06:28:29

© 2024 FCC.report