MPE report

FCC ID: 2AKIT-AS012

RF Exposure Info

Download: PDF
FCCID_4404919

                     CTC Laboratories, Inc.
1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
Tel: +86-755- 27521059 Fax: +86-755- 27521011 Http://www.sz-ctc.com.cn

                  Maximum Permissible Exposure Evaluation
                                               FCC ID: 2AKIT-AS012

According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment
impact of human exposure to radio frequency (RF) Radiation as specified in §1.1307(b)

EUT Specification
 EUT                                  Door and Window Sensor T1
 Frequency band (Operating)             WLAN: 2.412GHz ~ 2.462GHz
                                        WLAN: 5.18GHz ~ 5.32GHz / 5.50GHz ~ 5.70GHz
                                        WLAN: 5.745GHz ~ 5825GHz
                                        Others (Zigbee 2405MHz ~ 2480MHz)
 Device category                        Portable (<20cm separation)
                                        Mobile (>20cm separation)
                                        fixed (>20cm separation)
                                        Others ___
 Exposure classification                Occupational/Controlled exposure (S = 5mW/cm2)
                                        General Population/Uncontrolled exposure (S=1mW/cm2)
 Antenna diversity                      Single antenna
                                        Multiple antennas
                                        Tx diversity
                                        Rx diversity
                                        Tx/Rx diversity
 Max. output power                    11.06dBm
 Antenna gain (Max)                   2dBi
 Evaluation applied                     MPE Evaluation
                                        SAR Evaluation

Limits for Maximum Permissible Exposure (MPE)
          Frequency             Electric Field   Magnetic Field        Power                                             Average
         Range(MHz)            Strength(V/m)     Strength(A/m)    Density(mW/cm2)                                         Time
                         (A) Limits for Occupational/Control Exposures
          300-1500                    --               --              F/300                                                  6
         1500-100000                  --               --                 5                                                   6
                     (B) Limits for General Population/Uncontrol Exposures
          300-1500                    --               --              F/1500                                                 6
         1500-100000                  --               --                 1                                                  30




                                                      CTC Laboratories, Inc.
                   1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                     For anti-fake verification, please visit the official website of Certification and
                                                     Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn


                                                     Page 2 of 2                              Report No.: GTI20190626F-2


Friis transmission formula: Pd=(Pout*G)\(4*pi*R2)
Where
Pd= Power density in mW/cm2
Pout=output power to antenna in Mw
G= gain of antenna in linear scale
Pi=3.1416
R= distance between observation point and center of the radiator in cm
Pd the limit of MPE 1mW/cm2. If we know the maximum gain of the antenna and total power input to
the antenna, through the calculation, we will know the distance where the MPE limit is reached.
Measurement Result
                Max.                                                                                    Power              Power
 Channel                         Tune up              Max. Tune up                  Antenna
              Measured                                                                                density at          density
frequency                       tolerance               Power                        Gain
               Power                                                                                    20cm               Limits
  (MHz)                           (dBm)                  (dBm)                       (dBi)
               (dBm)                                                                                  (mW/cm2 )          (mW/cm2 )
  2405          11.00               11±1                      12                         2              0.00500                1

  2440          11.06               11±1                      12                         2              0.00500                1

  2480          -0.71               -1±1                       0                         2              0.00032                1

Note
For a more detailed features description, please refer to the RF Test Report.




                          **********************THE END**********************




                                                     CTC Laboratories, Inc.
                  1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                       Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                    For anti-fake verification, please visit the official website of Certification and
                                                    Accreditation Administration of the People’s Republic of China : http://yz.cnca.cn



Document Created: 2019-08-13 09:22:12
Document Modified: 2019-08-13 09:22:12

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC