                  Maximum Permissible Exposure Evaluation
                                                FCC ID: 2AKIT-AR001

According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment
impact of human exposure to radio frequency (RF) Radiation as specified in §1.1307(b)

EUT Specification
 EUT                                   Wireless Button T1
 Frequency band (Operating)              WLAN: 2.412GHz ~ 2.462GHz
                                         WLAN: 5.18GHz ~ 5.32GHz / 5.50GHz ~ 5.70GHz
                                         WLAN: 5.745GHz ~ 5825GHz
                                         Others (Zigbee 2405MHz ~ 2480MHz)
 Device category                         Portable (<20cm separation)
                                         Mobile (>20cm separation)
                                         fixed (>20cm separation)
                                         Others ___
 Exposure classification                 Occupational/Controlled exposure (S = 5mW/cm2)
                                         General Population/Uncontrolled exposure (S=1mW/cm2)
 Antenna diversity                       Single antenna
                                         Multiple antennas
                                         Tx diversity
                                         Rx diversity
                                         Tx/Rx diversity
 Max. output power                     10.35dBm
 Antenna gain (Max)                    2dBi
 Evaluation applied                      MPE Evaluation
                                         SAR Evaluation

Limits for Maximum Permissible Exposure (MPE)
          Frequency             Electric Field    Magnetic Field        Power                                                Average
         Range(MHz)             Strength(V/m)     Strength(A/m)    Density(mW/cm2)                                            Time
                          (A) Limits for Occupational/Control Exposures
           300-1500                    --               --              F/300                                                     6
         1500-100000                   --               --                 5                                                      6
                     (B) Limits for General Population/Uncontrol Exposures
           300-1500                    --               --              F/1500                                                    6
         1500-100000                   --               --                 1                                                     30




                                                        CTC Laboratories, Inc.
                   1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                        Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                     For anti-fake verification, please visit the official website of Certification and
                                                     Accreditation Administration of the People’s Republic of China : yz.cncaic.cn


                                                      Page 2 of 2                                Report No.: GTI20190634F-2


Friis transmission formula: Pd=(Pout*G)\(4*pi*R2)
Where
Pd= Power density in mW/cm2
Pout=output power to antenna in Mw
G= gain of antenna in linear scale
Pi=3.1416
R= distance between observation point and center of the radiator in cm
Pd the limit of MPE 1mW/cm2. If we know the maximum gain of the antenna and total power input to
the antenna, through the calculation, we will know the distance where the MPE limit is reached.
Measurement Result
                Max.                                                                                        Power              Power
 Channel                          Tune up               Max. Tune up                  Antenna
              Measured                                                                                    density at          density
frequency                        tolerance                Power                        Gain
               Power                                                                                        20cm               Limits
  (MHz)                            (dBm)                   (dBm)                       (dBi)
               (dBm)                                                                                      (mW/cm2 )          (mW/cm2 )
  2405          10.49               11±1                        12                         2               0.00500                 1

  2440          10.36               11±1                        12                         2               0.00500                 1

  2480           1.68                2±1                         3                         2               0.00063                 1

Note
For a more detailed features description, please refer to the RF Test Report.




                           **********************THE END**********************




                                                       CTC Laboratories, Inc.
                  1-2/F., Building 2, Jiaquan Building, Guanlan High-Tech Park, Shenzhen, Guangdong, China
                       Tel.: (86)755-27521059        Fax: (86)755-27521011         Http://www.sz-ctc.org.cn
                                                    For anti-fake verification, please visit the official website of Certification and
                                                    Accreditation Administration of the People’s Republic of China : yz.cncaic.cn



Document Created: 2019-08-14 11:57:28
Document Modified: 2019-08-14 11:57:28

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC