RF Exposure Info

FCC ID: 2AKI8-MZX250

RF Exposure Info

Download: PDF
FCCID_4349760

                                  Shenzhen Huaxia Testing Technology Co., Ltd
                                  1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District,
                                  Shenzhen, China
                                  Telephone:     +86-755-26648640
                                  Fax:           +86-755-26648637                 Report Template Version: V03
                                  Website:       www.cqa-cert.com                 Report Template Revision Date: Mar.1st, 2017



                              RF Exposure Evaluation Report

Report No. :                      CQASZ20190600459E-02
Applicant:                        TOPWAY EM ENTERPRISE LTD.
Address of Applicant:             8F BLOCK B BUILDING 6 BAONENG S & T PARK LONG HUA, SHENZHEN
                                  GD, China 518109
Equipment Under Test (EUT):
Product:                          Bluetooth Headphone
All Model No.:                    17LY87, MZX250, MZX250-BLUE, MZX250-PINK, MZX250-APRD, MZX250-
                                  GRPU, MZX250-RSPK, MZX250-BLUB, MZX250-APRD-SAM, MZX250-
                                  GRPU-SAM, MZX250-BLUB-SAM, MZX250-RSPK-SAM
Test Model No.:                   17LY87
Brand Name:                       Altec Lansing
FCC ID:                           2AKI8-MZX250
Standards:                        47 CFR Part 1.1307
                                  47 CFR Part 2.1093
                                  KDB447498D01 General RF Exposure Guidance v06

Date of Test:                     2019-06-11 to 2019-06-25
Date of Issue:                    2019-06-25
Test Result :                     PASS*




Tested By:
                                                (Daisy Qin)


Reviewed By:
                                                (Aaron Ma )


Approved By:
                                                 ( Jack Ai)




* In the configuration tested, the EUT complied with the standards specified above.

The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to

the sample(s) tested. Without written approval of CQA, this report can’t be reproduced except in full.


                                    Shenzhen Huaxia Testing Technology Co., Ltd
                                                      Report No.: CQASZ20190600459E-02


1   Version
                            Revision History Of Report

          Report No.          Version         Description           Issue Date
     CQASZ20190600459E-02      Rev.01        Initial report        2019-06-25




                              Page:2 of 6


                                                                                 Shenzhen Huaxia Testing Technology Co., Ltd
                                                                                                                    Report No.: CQASZ20190600459E-02



2         Contents
                                                                                                                                                                         Page
1       VERSION .....................................................................................................................................................................2

2       CONTENTS .................................................................................................................................................................3

3       GENERAL INFORMATION .......................................................................................................................................4
    3.1     CLIENT INFORMATION................................................................................................................................................4
    3.2     GENERAL DESCRIPTION OF EUT ................................................................................................................................4
4       SAR EVALUATION ....................................................................................................................................................5
    4.1 RF EXPOSURE COMPLIANCE REQUIREMENT ..............................................................................................................5
       4.1.1 Standard Requirement .................................................................................................................................5
       4.1.2 Limits ..............................................................................................................................................................5
       4.1.3 EUT RF Exposure .........................................................................................................................................6




                                                                     Page:3 of 6


                                                    Shenzhen Huaxia Testing Technology Co., Ltd
                                                                      Report No.: CQASZ20190600459E-02



3        General Information
3.1 Client Information
         Applicant:                 TOPWAY EM ENTERPRISE LTD.
         Address of Applicant:      8F BLOCK B BUILDING 6 BAONENG S & T PARK LONG HUA,
                                    SHENZHEN GD, China 518109
         Manufacturer:              SHENZHEN JIA HUA LI DIAN ZI YOU XIAN GONG SI
         Address of Manufacturer:   NO 101,201, BUILDING E, NEW INDUSTRIAL ZONE, SHENZHU ROAD,
                                    LIUYUE SHENKENG VILLAGE, HENGGANG, LONGGANG DISTRICT,
                                    SHENZHEN CHINA

3.2 General Description of EUT
        Product Name:               Bluetooth Headphone
                                    17LY87, MZX250, MZX250-BLUE, MZX250-PINK, MZX250-APRD,
        All Model No.:              MZX250-GRPU, MZX250-RSPK, MZX250-BLUB, MZX250-APRD-SAM,
                                    MZX250-GRPU-SAM, MZX250-BLUB-SAM, MZX250-RSPK-SAM
        Test Model No.:             17LY87
        Trade Mark:                 Altec Lansing
        Hardware Version:           V1.0
        Software Version:           V1.0
        Operation Frequency:        2402MHz~2480MHz
        Bluetooth Version:          V5.0
        Modulation Technique:       Frequency Hopping Spread Spectrum(FHSS)
        Modulation Type:            GFSK, π/4DQPSK
        Transfer Rate:              1Mbps/2Mbps
        Number of Channel:          79
        Hopping Channel Type:       Adaptive Frequency Hopping systems
        Product Type:                    Mobile      Portable     Fix Location
        Test Software of EUT:       FCCAssist 2.4 (manufacturer declare )
        Antenna Type:               PCB antenna
        Antenna Gain:               0dBi
        Power Supply:               lithium battery:DC3.7V, Charge by DC5.0V

Note:
All model: 17LY87, MZX250, MZX250-BLUE, MZX250-PINK, MZX250-APRD, MZX250-GRPU, MZX250-RSPK,
MZX250-BLUB, MZX250-APRD-SAM, MZX250-GRPU-SAM, MZX250-BLUB-SAM, MZX250-RSPK-SAM
Only the model 17LY87 was tested, since the electrical circuit design, layout, components used and internal
wiring were identical for the above models, with difference being color of appearance and model name.




                                             Page:4 of 6


                                                Shenzhen Huaxia Testing Technology Co., Ltd
                                                                     Report No.: CQASZ20190600459E-02



4    SAR Evaluation
4.1 RF Exposure Compliance Requirement
4.1.1 Standard Requirement
     According to KDB447498D01 General RF Exposure Guidance v06
     4.3.1. Standalone SAR test exclusion considerations
            Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head
     or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement
     or numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition,
     listed below, is satisfied.
4.1.2 Limits
     The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
     ≤ 50 mm are determined by:

     [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·
     [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where

        f(GHz) is the RF channel transmit frequency in GHz
        Power and distance are rounded to the nearest mW and mm before calculation17
        The result is rounded to one decimal place for comparison
     The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and
     for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
     distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion




                                         Page:5 of 6


                                                   Shenzhen Huaxia Testing Technology Co., Ltd
                                                                       Report No.: CQASZ20190600459E-02




4.1.3 EUT RF Exposure
Measurement Data
                                                GFSK mode
                                                        Tune up tolerance            Maximum tune-up Power
       Test channel               Peak Output Power
                                       (dBm)                     (dBm)                (dBm)          (mW)

    Lowest(2402MHz)                    -1.880                    -2.5±1                  -1.5        0.708
     Middle(2441MHz)                   -0.890                    -1.5±1                  -0.5        0.891
    Highest(2480MHz)                   -0.490                     -1±1                    0          1.000
                                              π/4DQPSK mode
                                                        Tune up tolerance            Maximum tune-up Power
       Test channel               Peak Output Power
                                       (dBm)                     (dBm)                (dBm)          (mW)

    Lowest(2402MHz)                    -0.900                    -1.5±1                  -0.5        0.891
     Middle(2441MHz)                   0.070                     -0.5±1                  0.5         1.122
    Highest(2480MHz)                   0.360                     -0.5±1                  0.5         1.122

  Worst case: π/4DQPSK
                       Maximum                          Maximum tune-
                         Peak            Tune up            up Power
                                                                            Calculated          Exclusion
     Channel           Conducted         tolerance
                                                                              value             threshold
                      Output Power        (dBm)         (dBm)    (mW)
                         (dBm)
      Lowest
                         -0.900           -1.5±1         -0.5    0.891        0.28
    (2402MHz)
      Middle
                                                                                                   3.0
    (2441MHz)            0.070            -0.5±1         0.5     1.122        0.35

      Highest
    (2480MHz)            0.360            -0.5±1         0.5     1.122        0.35

  Conclusion: the calculated value ≤3.0, SAR is exempted.

Remark: The Max Conducted Peak Output Power data refer to report Report No.: CQASZ20190600459E-01




                                          Page:6 of 6



Document Created: 2019-07-09 23:01:07
Document Modified: 2019-07-09 23:01:07