14_GN-EW002-999 TestRpt

FCC ID: 2AKG3GNEW002999

Test Report

Download: PDF
FCCID_4048350

                                                                                   Page 1 of 22




                          FCC TEST REPORT



                                         Test report
                                        On Behalf of
                         Shenzhen JBT Smart Lighting Co.,LTD
                                             For
                                         LED STRIP
                      Model No.: GN-EW002-999, GNU-EW002-999,
                  GNC-EW002-999, GNC-EW002-999, MI-EW003-999W,
                   GN-EW002-999, MI-EW003-999W, 837004, 837003


                                  FCC ID: 2AKG3GNEW002999




 Prepared for :    Shenzhen JBT Smart Lighting Co.,LTD
                   No.7 Building,No.1 Furong Road,Furong Industrial Park,Shajing Town,Baoan
                   District,Shenzhen City China.




 Prepared By :     Shenzhen HUAK Testing Technology Co., Ltd.
                   1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street,
                   Bao'an District, Shenzhen City, China




Date of Test:      Aug.30, 2018 ~ Sep.03, 2018
Date of Report:    Sep.04, 2018
Report Number:     HUAK180905986E


                                                                                                          Report No.: HUAK180905986E

                                                                                                                                    Page 2 of 22


                                                       TABLE OF CONTENTS
1. VERIFICATION OF CONFORMITY .......................................................................................................3
2. SYSTEM DESCRIPTION .......................................................................................................................4
3. MEASUREMENT UNCERTAINTY .........................................................................................................4
4. PRODUCT INFORMATION ....................................................................................................................5
5. SUPPORT EQUIPMENT ........................................................................................................................6
6. TEST FACILITY .....................................................................................................................................7
7. FCC LINE CONDUCTED EMISSION TEST ..........................................................................................8
   7.1. LIMITS OF LINE CONDUCTED EMISSION TEST...........................................................................8
   7.2. BLOCK DIAGRAM OF TEST SETUP ..............................................................................................8
   7.3. PROCEDURE OF LINE CONDUCTED EMISSION TEST ...............................................................9
   7.4. TEST RESULT OF LINE CONDUCTED EMISSION TEST ............................................................10
8. FCC RADIATED EMISSION TEST ......................................................................................................12
   8.1. LIMITS OF RADIATED EMISSION TEST ......................................................................................12
   8.2. BLOCK DIAGRAM OF TEST SETUP ............................................................................................12
   8.3. PROCEDURE OF RADIATED EMISSION TEST ...........................................................................13
   8.4. TEST RESULT OF RADIATED EMISSION TEST ..........................................................................14
APPENDIX A: PHOTOGRAPHS OF TEST SETUP ................................................................................16
APPENDIX B: PHOTOGRAPHS OF EUT ...............................................................................................17


                                                                         Report No.: HUAK180905986E

                                                                                         Page 3 of 22


1. VERIFICATION OF CONFORMITY
Applicant                  Shenzhen JBT Smart Lighting Co., LTD
                           No.7 Building, No.1 Furong Road, Furong Industrial Park, Shajing Town,
Address
                           Baoan District, Shenzhen City China.
Manufacturer               Shenzhen JBT Smart Lighting Co., LTD
                           No.7 Building, No.1 Furong Road, Furong Industrial Park, Shajing Town,
Address
                           Baoan District, Shenzhen City China.
Product Designation        LED STRIP
Brand Name                 N/A
Test Model                 GN-EW002-999
                           GNU-EW002-999, GNC-EW002-999, GNC-EW002-999, MI-EW003-999W,
Series Models
                           GN-EW002-999, MI-EW003-999W, 837004, 837003
Model Difference           All the same except from the model name.
Measurement Procedure ANSI C63.4: 2014
Date of test               Aug.30, 2018 to Sep.03, 2018
Deviation                  None
Condition of Test
                           Normal
Sample
Test Result                Pass
Report Template            AGCRT-US-IT/AC(2013-03-01)
The above equipment was tested by Shenzhen HUAK Testing Technology Co., Ltd. for compliance with
the requirements set forth in the FCC Rules and Regulations Part 15, the measurement procedure
according to ANSI C63.4:2014. This said equipment in the configuration described in this report shows
the maximum emission levels emanating from equipment are within the compliance requirements.
The test results of this report relate only to the tested sample identified in this report.


                    Testing Engineer      :


                                                          (Gary Qian)

                    Technical Manager     :

                                                           (Eden Hu)


                    Authorized Signatory :


                                                          (Jason Zhou)


                                                                         Report No.: HUAK180905986E

                                                                                          Page 4 of 22


2. SYSTEM DESCRIPTION
                                     TEST MODE DESCRIPTION
NO.                       TEST MODE DESCRIPTION                                      WORST
  1                               Light on mode                                         V
Note:1. V means EMI worst mode.




3. MEASUREMENT UNCERTAINTY
    The uncertainty is calculated using the methods suggested in the “Guide to the Expression of
Uncertainty in measurement” (GUM) published by CISPR and ANSI.
 - Uncertainty of Radiated Conducted Emission, Uc = ±2.56 dB
 - Uncertainty of Radiated Emission Below 1G, Uc = ±3.92 dB
 - Uncertainty of Radiated Emission Above 1G, Uc = ±4.28 dB


                                                                       Report No.: HUAK180905986E

                                                                                      Page 5 of 22


4. PRODUCT INFORMATION
Housing Type                  Plastic and metal
Hardware Version              TYWE3S
Software Version              3.3.1
FCC ID                        2AKG3GNEW002999
Adapter Model                 JK120100-S37USVD
Adapter Input Rating          AC 100-240V 50/60Hz 0.5A
Adapter Output Rating         DC 12V 1000mA




                         I/O Port Information (   Applicable   Not Applicable)

                                             I/O Port of EUT
      I/O Port Type                      Number                Cable Description    Tested With
         DC Input port                       1                 1.50m Unshielded          1
          6 pin port                         1                 0.10m Unshielded          1


                                                                    Report No.: HUAK180905986E

                                                                                   Page 6 of 22


5. SUPPORT EQUIPMENT
   Device Type        Manufacturer        Model Name   Serial No.     Data Cable   Power Cable
         --                  --                 --         --             --            --
Note:
1.“-- “means no any support device during testing.


                                                                            Report No.: HUAK180905986E

                                                                                            Page 7 of 22


6. TEST FACILITY

          Site              Shenzhen HUAK Testing Technology Co., Ltd.
                            1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Fuhai Street,
        Location
                            Bao'an District, Shenzhen City, China
Designation Number          CN1229
     Test Firm
                            616276
Registration Number

                                                                                                    Cal.
 Item        Equipment            Manufacturer      Model No.       Serial No.      Last Cal.
                                                                                                  Interval
               L.I.S.N.
  1.       Artificial Mains            R&S           ENV216         HKE-002       Dec. 28, 2017 1 Year
              Network
  2.             Receiver              R&S           ESCI 7         HKE-010       Dec. 28, 2017 1 Year
           RF automatic
  3.                                 Tonscend       JS0806-2        HKE-060       Dec. 28, 2017 1 Year
            control unit
  4.     Spectrum analyzer             R&S            FSP40         HKE-025       Dec. 28, 2017 1 Year
  5.     Spectrum analyzer            Agilent        N9020A         HKE-048       Dec. 28, 2017 1 Year
  6.        Preamplifier          Schwarzbeck       BBV 9743        HKE-006       Dec. 28, 2017 1 Year
  7.     EMI Test Receiver      Rohde & Schwarz      ESCI 7         HKE-010       Dec. 28, 2017 1 Year
          Bilog Broadband
  8.                              Schwarzbeck       VULB9163        HKE-012       Dec. 28, 2017 1 Year
              Antenna
                                                   FMZB 1519
  9.       Loop Antenna           Schwarzbeck                       HKE-014       Dec. 28, 2017 1 Year
                                                      B
 10.       Horn Antenna          Schewarzbeck         9120D         HKE-013       Dec. 28, 2017 1 Year
                                                   EMC051845
  11.       Pre-amplifier              EMCI                         HKE-015       Dec. 28, 2017 1 Year
                                                      SE
 12.        Pre-amplifier             Agilent        83051A         HKE-016       Dec. 28, 2017 1 Year
         EMI Test Software                          JS1120-B
 13.                                 Tonscend                       HKE-083       Dec. 28, 2017    N/A
             EZ-EMC                                  Version
 14.       Power Sensor               Agilent        E9300A         HKE-086       Dec. 28, 2017 1 Year
 15.     Spectrum analyzer            Agilent        N9020A         HKE-048       Dec. 28, 2017 1 Year
 16.      Signal generator            Agilent        N5182A         HKE-029       Dec. 28, 2017 1 Year
 17.      Signal Generator            Agilent        83630A         HKE-028       Dec. 28, 2017 1 Year
 18.       Shielded room             Shiel Hong       4*3*3         HKE-039       Dec. 28, 2017 3 Year


                                                                             Report No.: HUAK180905986E

                                                                                               Page 8 of 22


7. FCC LINE CONDUCTED EMISSION TEST

7.1. LIMITS OF LINE CONDUCTED EMISSION TEST

                                                           Maximum RF Line Voltage
            Frequency
                                                Q.P.( dBuV)                       Average( dBuV)
          150kHz-500kHz                            66-56                               56-46
          500kHz-5MHz                                56                                  46
           5MHz-30MHz                                60                                  50
Note:
1. The lower limit shall apply at the transition frequency.
2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 MHz to 0.50MHz.
   For unintentional device, according to § 15.107(a) Line Conducted Emission Limits is as following
   For intentional device, according to §15.207(a) Line Conducted Emission Limit is same as above table.
7.2. BLOCK DIAGRAM OF TEST SETUP


                                                                          Report No.: HUAK180905986E

                                                                                           Page 9 of 22


7.3. PROCEDURE OF LINE CONDUCTED EMISSION TEST

(1)   The equipment was set up as per the test configuration to simulate typical actual usage per the
       user’s manual. When the EUT is a tabletop system, a wooden table with a height of 0.8 meters is
       used and is placed on the ground plane as per ANSI C63.4 (see Test Facility for the dimensions of
       the ground plane used). When the EUT is a floor-standing equipment, it is placed on the ground
       plane which has a 3-12 mm non-conductive covering to insulate the EUT from the ground plane.
(2)   Support equipment, if needed, was placed as per ANSI C63.4.
(3)   All I/O cables were positioned to simulate typical actual usage as per ANSI C63.4.
(4)   The EUT received DC12V power from adapter which received AC120V/60Hz power from a LISN.
(5)   The EUT test program was started. Emissions were measured on each current carrying line of the
       EUT using a spectrum Analyzer / Receiver connected to the LISN powering the EUT. The LISN has
       two monitoring points: Line 1 (Hot Side) and Line 2 (Neutral Side). Two scans were taken: one
       with Line 1 connected to Analyzer / Receiver and Line 2 connected to a 50 ohm load; the second
       scan had Line 1 connected to a 50 ohm load and Line 2 connected to the Analyzer / Receiver.
(6)   Analyzer / Receiver scanned from 150 kHz to 30MHz for emissions in each of the test modes.
(7)   During the above scans, the emissions were maximized by cable manipulation.
(8)   A scan was taken on both power lines, Line 1 and Line 2, recording at least the six highest
      emissions.
(9)   Emission frequency and amplitude were recorded into a computer in which correction factors were
       used to calculate the emission level and compare reading to the applicable limit. If EUT emission
       level was less –2dB to the A.V. limit in Peak mode, then the emission signal was re-checked using
       Q.P and Average detector.


                                                         Report No.: HUAK180905986E

                                                                       Page 10 of 22


7.4. TEST RESULT OF LINE CONDUCTED EMISSION TEST

                        LINE CONDUCTED EMISSION TEST-L




RESULT: PASS


                                                Report No.: HUAK180905986E

                                                              Page 11 of 22

               LINE CONDUCTED EMISSION TEST-N




RESULT: PASS


                                                                        Report No.: HUAK180905986E

                                                                                      Page 12 of 22


8. FCC RADIATED EMISSION TEST

8.1. LIMITS OF RADIATED EMISSION TEST
          Frequency                        Distance              Maximum Field Strength Limit
            (MHz)                             (m)                      (dBuV/m/ Q.P.)
             30~88                              3                            40.0
            88~216                              3                            43.5
           216~960                              3                            46.0
          Above 960                             3                            54.0
Note: The lower limit shall apply at the transition frequency.



8.2. BLOCK DIAGRAM OF TEST SETUP

                       System Diagram of Connections between EUT and Simulators


                                                                           Report No.: HUAK180905986E

                                                                                            Page 13 of 22


8.3. PROCEDURE OF RADIATED EMISSION TEST

(1)   The equipment was set up as per the test configuration to simulate typical actual usage per the
      user’s manual. When the EUT is a tabletop system, a wooden turntable with a height of 0.8 meters
      is used which is placed on the ground plane as per ANSI C63.4 (see Test Facility for the
      dimensions of the ground plane used). When the EUT is floor-standing equipment, it is placed on
      the ground plane which has a 3-12 mm non-conductive covering to insulate the EUT from the
      ground plane.
(2)   Support equipment, if needed, was placed as per ANSI C63.4.
(3)   All I/O cables were positioned to simulate typical actual usage as per ANSI C63.4.
(4)   The EUT was turned on. All support equipments received AC120V/60Hz power from socket under
      the turntable, if any.
(5)   The antenna was placed at 3 meter away from the EUT as stated in FCC Part 15. The antenna
      connected to the Analyzer via a cable and at times a pre-amplifier would be used.
(6)   The Analyzer / Receiver quickly scanned from 30MHz to 1000MHz. The EUT test program was
      started. Emissions were scanned and measured rotating the EUT to 360 degrees and positioning
      the antenna 1 to 4 meters above the ground plane, in both the vertical and the horizontal
      polarization, to maximize the emission reading level.
(7)   The test mode(s) were scanned during the test:
(8)   Recorded at least the six highest emissions. Emission frequency, amplitude, antenna position,
        polarization and turntable position were recorded into a computer in which correction factors were
        used to calculate the emission level and compare reading to the applicable limit and Q.P./Peak
        reading is presented.


                                                                   Report No.: HUAK180905986E

                                                                                 Page 14 of 22


8.4. TEST RESULT OF RADIATED EMISSION TEST

                       Radiated Emission Test at 3m Distance-Horizontal




                                 Factor     Level    Limit
Frequency              Reading                              Margin           Height Angle
          Polarization            dB      dB(uV/m) dB(uV/m)        Pass/Fail
   MHz                 dB(uV)                                dB               cm     deg
                                 (1/m)       PK       QP
 45.520        H         6.4     17.3       23.7       40.0      16.3     Pass   150.0    23.9
 61.525        H         7.2     16.0       23.2       40.0      16.8     Pass   150.0    23.9
 149.310       H        11.3     16.6       27.9       43.5      15.6     Pass   150.0   142.3
 185.685       H        13.9     14.0       27.9       43.5      15.6     Pass   150.0   334.8
 256.010       H        12.3     16.0       28.3       46.0      17.7     Pass   150.0    20.6
 364.165       H         9.9     19.5       29.4       46.0      16.6     Pass   150.0    20.6


RESULT: PASS


                                                                       Report No.: HUAK180905986E

                                                                                     Page 15 of 22

                           Radiated Emission Test at 3m Distance-Vertical




                                   Factor     Level    Limit
Frequency              Reading                                Margin           Height Angle
          Polarization              dB      dB(uV/m) dB(uV/m)        Pass/Fail
   MHz                 dB(uV)                                  dB               cm     deg
                                   (1/m)       PK       QP
 36.305          V         11.5     16.6      28.1        40.0      11.9     Pass    100.1   292.1
 54.250          V         8.8      16.8      25.6        40.0      14.4     Pass    100.1   215.9
 67.830          V         12.9     15.0      27.9        40.0      12.1     Pass    100.1   195.1
 148.340         V         17.0     16.6      33.6        43.5      9.9      Pass    100.1   198.3
 186.170         V         11.5     14.0      25.5        43.5      18.0     Pass    100.1   261.0
 254.070         V         12.1     16.0      28.1        46.0      17.9     Pass    100.1   138.9


RESULT: PASS
Note:
Level(dBuV/m)=Reading(dBuV)+Factor(dB/m)
Factor(dB/m)=Antenna Factor(dB/m)+Cable loss(dB)+Attenuation(dB)for Attenuator
Margin= Limit -Level
All Other modes above 1GHz have more than 20db margin, no recording in the report


                                        Report No.: HUAK180905986E

                                                      Page 16 of 22


APPENDIX A: PHOTOGRAPHS OF TEST SETUP
  FCC LINE CONDUCTED EMISSION TEST SETUP




     FCC RADIATED EMISSION TEST SETUP


                            Report No.: HUAK180905986E

                                          Page 17 of 22


APPENDIX B: PHOTOGRAPHS OF EUT
        ALL VIEW OF EUT




        TOP VIEW OF EUT


                     Report No.: HUAK180905986E

                                   Page 18 of 22

BOTTOM VIEW OF EUT




FRONT VIEW OF EUT


                   Report No.: HUAK180905986E

                                 Page 19 of 22

BACK VIEW OF EUT




LEFT VIEW OF EUT


                    Report No.: HUAK180905986E

                                  Page 20 of 22

RIGHT VIEW OF EUT




OPEN VIEW OF EUT


                         Report No.: HUAK180905986E

                                       Page 21 of 22

INTERNAL VIEW OF EUT-1




INTERNAL VIEW OF EUT-2


                         Report No.: HUAK180905986E

                                       Page 22 of 22

INTERNAL VIEW OF EUT-3




----END OF REPORT----



Document Created: 2018-10-18 16:08:13
Document Modified: 2018-10-18 16:08:13

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC