MPE report

FCC ID: 2AKDX-8003ZH

RF Exposure Info

Download: PDF
FCCID_4353119

                                     Shenzhen BCTC Testing Co., Ltd.



                              FCC ID:2AKDX-8003ZH

RF EXPOSURE EVALUATION
1. Introduction
According to FCC 1. 1310: The criteria listed in the following table shall be used to evaluate the
environment impact of human exposure to radio frequency(RF) Radiation as specified in
§1.1307(b), a device is defined as a transmitting device designed to be used in other than fixed
locations and to generally be used in such a way that a separation distance of at least 20 cm is
normally maintained between the transmitting antenna and the body of the user or nearby
persons. In this context, the term “fixed location” means that the device is physically secured at
one location and is not able to be easily moved to another location. Transmitting devices
designed to be used by consumers or workers that can be easily re-located, such as wireless
devic es associated with a personal computer, are considered to be mobile devices if they meet
the 20 cm separation requirement. The limits to be used for MPE evaluation are specified in
§1.1310. All unlicens ed personal communications service (P CS) devices and unlicensed NII
devic es shall be subject to the limits for general population/uncontrolled exposure.

2.RF Radiation Exposure Limits
According to 47 CFR §1.1310, the criteria listed in below table shall be use d to evaluate the
environmental impact of human exposure to RF radiation as specified in §1.1307(b), except in the
case of portable devices which shall be evaluated according to the provisions of §2.1093.




Notes: 1. f = frequency in MHz 2. Occupational/c ont rolled limits apply in situations in which
persons are exposed as a consequenc e of their employment provided those persons are fully
aware of the potential for expos ure and can exercise control over their exposure. Limits for
occupational/controlled exposure also apply in situations when an individual is transient through a
location where occupational/controlled limits apply provided they are made aware of the pot ential
for exposure. 3. General population/uncontrolled exposures apply in situations in whi ch the
general public may be exposed, or in which persons that are exposed as a consequence of their
employment may not be fully aware of the pot ential for ex posure or cannot exercise control over
their exposure.


                                                       Shenzhen BCTC Testing Co., Ltd.


           3.MPE Assessment Method

           Calculations can be made to predict RF field strength and power density levels around typical RF
           sources. For example, in the case of a single radiating antenna, a prediction for power density in
           the far-field of the antenna can be made by use of the general Equations below. This equation is
           generally accurate in the far-field of an ant enna but will over-predict power density in the near
           field, where they could be used for making a "worst case" or conservative prediction.




           Where
           S = Power Density, unit in mW/cm2
           P = Power input to the antenna, unit in mW
           G = Power gain of the antenna in the direction of interest relative to an isotropic radiator
           R = Distance to the center of radiation of the antenna, unit in cm
           EIRP = Effective isotropically radiated power

           4. MPE Calculation for Standalone Operations
           Operation Frequency: 2409. 75-2475 MHz
                                          2
           Power density limited: 1mW/ cm
           Antenna Type: External Ant enna
           Antenna gain: 1dBi,
           R=20cm
           mW=10^(dBm/ 10)

                                                                                                                                           Power
Channel                   conducted   conducted                       Max                 Max             Antenna
                                                     Tune-up                                                        Ev aluation result    density
 Freq.       modulation     power       power                    tune-up power       tune-up power         Gain
                                                   power (dBm)                                                         (mW/cm2 )           Limits
 (MHz)                      (dBm)       (mW)                         (dBm)               (mW)             Numeric
                                                                                                                                         (mW/cm2)

2409.75        GFSK         4.35         2.72          5±1            6                  3.98              1.259       0.000997             1

2442.375       GFSK         5.51         3.56          5±1            6                  3.98              1.259       0.000997             1

 2475          GFSK         4.95         3.13          5±1            6                  3.98              1.259       0.000997             1




           emission

                                      Pow er density Limits       Calculate Evaluation          Pow er density
                                          (mW/cm2 )                      result                     Limits
                                              2.4G                    (mW/cm2 )                   (mW/cm2)

                                           0.000997                       0.000997                    1


           Conclusion:

           For the max res ult : 0.000997≤ 1. 0, compliance with FCC's RF Exposure.
           Summary: Since the ERP (effective radiated power) operated at < 1.5 GHz is less than 1.5 watts
           and > 1.5 GHz is less than 3 watts, the routine environmental evaluation is not required, and the
           MPE result calculated for this device complies with the MPE limit as specified in 47 CFR §1.1310.



Document Created: 2019-07-09 02:46:38
Document Modified: 2019-07-09 02:46:38